Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nondestructive analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Overview of the latest nondestructive assay technology

Nondestructive Assay (NDA) techniques are an important tool for the safeguarding of nuclear materials. NDA techniques are used by inspectors from both domestic agencies and international agencies such as the International Atomic Energy Agency as well as site level nuclear material management programs to verify that inventories of nuclear materials. This technology has been in development for over 40 years and significant improvements in detector capabilities, electronics processing and data analysis has lead to new detection capabilities and greatly improved quantification of nuclear materials. Many of the improvements over the last decade have resulted from improved computing power. This has lead to the ability to collect and analyze data in ways not possible only years ago. This poster will present some of the improvements of nondestructive assay technologies over the past several years and the implementation of these technologies in nuclear safeguards programs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Methods for diagnosing and quantifying double pulsing in a Uranium Neutron Collar system using shift register logic

Double pulsing in neutron coincidence counters is the result of a pulse processing chain-3He proportional counter timing incompatibility known to nondestructive assay system designers. It is not currently widely acknowledged, or accounted for, in the user community. However, it is gaining attention as list mode data acquisition and analysis becomes more commonly used for system diagnostics, revealing features that have been overlooked by historic timing gate selection using traditional shift register data acquisition methods. Double pulsing increases the apparent number of measured neutron events from a source. Therefore, it may contribute to a falsely increased count rate if present at the operational high voltage used when assaying samples, even with set predelays. The authors have previously studied the effects of double pulsing, using list mode data acquisition and analysis on neutron pulse trains in three common neutron coincidence counting systems used in routine measurements for international safeguards: a Canberra Industries JCC-71 Neutron Coincidence Collar, a variant on the Canberra Industries JCC-51 Active Well Neutron Coincidence Counter (the Large Volume Active Well Neutron Coincidence Counter), and an AnTech Inc. N2071 Neutron Coincidence Collar. We find that this non-ideal behavior was isolated to the Amptek A111 Charge Sensitive Preamplifier & Discriminator chip used in both the Canberra Industries and Antech systems. The double pulsing fraction was calculated in post-analysis for various high voltage settings in these A111-based systems, assuming no predelay settings. In this work, the authors expand upon this identification and analysis to make it more translatable between list mode data acquisition and analysis and shift register-based analysis. By investigating the double pulsing fractions in a JCC-71 Uranium Neutron Collar as a function of predelay settings, as well as describing and performing alternative tests and analyses to diagnose and quantify the double pulsing using shift register logic, this work hopes to complete the picture of double pulsing identification and analysis.

Safeguards↗

Measurement of surface recombination velocity and bulk lifetime in Si wafers by the kinetics of excess thermal emission

A contactless nondestructive technique for measuring recombination parameters (surface recombination velocity and bulk and effective lifetime of free carriers) in Si wafers is proposed. The technique is based on the analysis of the relaxation kinetics of excess thermal emission of a wafer beyond the Si intrinsic absorption edge ({lambda} > 3 {mu}m) after excitation by a short laser pulse with a photon energy higher than the Si band gap. Experimental results for wafers 300 {mu}m and 2 mm thick, excited by laser radiation with wavelengths of 0.96 and 1.06 {mu}m at above-room temperatures are presented. The surface and bulk components of the effective lifetime are separated by extrapolating the final portion of the kinetics of excess thermal emission relaxation to the intersection with the y coordinate axis.

36 MATERIALS SCIENCE↗

Automatic Detection of Defects in High-Reliability Components

Disastrous consequences can result from defects in manufactured parts—particularly the high consequence parts developed at Sandia. Identifying flaws in as-built parts can be done with nondestructive means, such as X-ray Computed Tomography (CT). However, due to artifacts and complex imagery, the task of analyzing the CT images falls to humans. Human analysis is inherently unreproducible, unscalable, and can easily miss subtle flaws. We hypothesized that deep learning methods could improve defect identification, increase the number of parts that can effectively be analyzed, and do it in a reproducible manner. We pursued two methods: 1) generating a defect-free version of a scan and looking for differences (PandaNet), and 2) using pre-trained models to develop a statistical model of normality (Feature-based Anomaly Detection System: FADS). Both PandaNet and FADS provide good results, are scalable, and can identify anomalies in imagery. In particular, FADS enables zero-shot (training-free) identification of defects for minimal computational cost and expert time. It significantly outperforms prior approaches in computational cost while achieving comparable results. FADS’ core concept has also shown utility beyond anomaly detection by providing feature extraction for downstream tasks.

47 OTHER INSTRUMENTATION↗

Corrosion detection and evaluation

Report details comprehensive study of nondestructive methods for detecting and/or evaluating up to six different types of corrosion: general, galvanic filiform, pitting, intergranular, and stress. Studied methods include: visual/optical inspection, radiography, penetrant inspection, analysis by polarized light, electrical conductivity measurements, pH analysis, and ultrasonic inspection.

Kammerer, C. C.↗

Analyzing For Light Elements By X-Ray Scattering

Nondestructive method of determining concentrations of low-atomic-number elements in liquids and solids involves measurements of Compton and Rayleigh scattering of x rays. Applied in quantitative analysis of low-atomic-number constituents of alloys, of contaminants and corrosion products on surfaces of alloys, and of fractions of hydrogen in plastics, oils, and solvents.

Ross, H. Richard↗

Analytical Platform To Characterize Dopant Solution Concentrations, Charge Carrier Densities in Films and Interfaces, and Physical Diffusion in Polymers Utilizing Remote Field-Effect Transistors

Characterizing doping effects in a conductive polymer and physical diffusion in a passive polymer were performed using a remote-gate field-effect transistor (RG FET) detection system that was able to measure the electrical potential perturbation of a polymer film coupled to the gate of a silicon FET. Poly(3-hexylthiophene) (P3HT) film doped using various concentrations of 2,3,5,6-tetrafluoro-7,7,8,8-tetracyanoquinodimethane (F4TCNQ) solutions imposed additional positive potentials on the P3HT RG, resulting in a lower threshold voltage ($V_{th}$) on the n-channel silicon FET. Changes in $V_{th}$ were related to the induced hole concentrations and hole mobility in P3HT films by using our $V_{th}$ shifting model for the RG FET. We discovered that the electron-donating P3HT and even inorganic materials, indium tin oxide and gold, showed similar electrical potential perturbations dependent on the concentration of F4TCNQ in overlying solutions as the dopant radical anions maximally covered the surfaces. This suggests that there are limited electroactive sites for F4TCNQ binding on electron donor surfaces which results in a similar number of positive charges in film materials forming dipoles with the F4TCNQ radical counteranions. The effect of electron acceptors such as 7,7,8,8-tetracyanoquinodimethane and tetracyanoethylene was compared with that of F4TCNQ in terms of $V_{th}$ shift using our analytical tool, with differences attributed to acceptor size and reduction potential. Meanwhile, this FET analysis tool offered a means of monitoring the physical diffusion of small molecules, exemplified by F4TCNQ, in the passive polymer polystyrene, driven by concentration gradients. The technique allows for nondestructive, nonspectroscopic, ambient characterization of electron donor-acceptor interactions at surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-throughput single-cell sorting by stimulated Raman-activated cell ejection

Raman-activated cell sorting isolates single cells in a nondestructive and label-free manner, but its throughput is limited by small spontaneous Raman scattering cross section. Coherent Raman scattering integrated with microfluidics enables high-throughput cell analysis, but faces challenges with small cells (<3 μm) and tissue sections. Here, we report stimulated Raman-activated cell ejection (S-RACE) that enables high-throughput single-cell sorting by integrating stimulated Raman imaging, in situ image decomposition, and laser-induced cell ejection. S-RACE allows ejection of live bacteria or fungi guided by their Raman signatures. Furthermore, S-RACE successfully sorted lipid-richRhodotorula glutiniscells from a cell mixture with a throughput of ~13 cells per second, and the sorting results were confirmed by downstream quantitative polymerase chain reaction. Beyond single cells, S-RACE shows high compatibility with tissue sections. Incorporating a closed-loop feedback control circuit further enables real-time SRS imaging-identification-ejection. In summary, S-RACE opens exciting opportunities for diverse single-cell sorting applications.

Science & Technology - Other Topics↗

Study of multiple hologram recording in lithium niobate

The results of a number of theoretical and experimental studies relating to multiple hologram recording in lithium niobate are reported. The analysis of holographic gratings stored in lithium niobate has been extended to cover a more realistic range of physical situations. A new successful dynamic (feedback) theory for describing recording, nondestructive reading, erasure, enhancement, and angular sensitivity has been developed. In addition, the possible architectures of mass data storage systems have been studied.

Gaylord, T. K.↗

Insulation Debond Detection

Load-cell and acoustic responses indicate bonding condition nondestructively. Signal recorded by load cell direct and instantaneous measure of local stiffness of material at point of impact. Separate and distinctly different measurement that sensed by microphone. Spectrum analysis of pulse obtained from debonded point will only show frequencies below 425 Hz because insulation alone does not have stiffness to support energy at higher frequencies.

Johnston, G. D.↗

Surface Characterization and Contamination

Nondestructive characterization of surface contamination can play an extremely important role in improving quality in manufacturing processes. This area of interest led to the formation of a Surface Contamination Analysis Team (SCAT) at Marshall Space Flight Center, which is primarily concerned with critical bondlines and has provided the major focus for activities under this grant. In addition, determining minute levels of contamination on emerging aerospace systems fabricated from composites has also been an area of interest for which the methods being presented here can be used. Important considerations for the inspection methodologies are good sensitivity, large area coverage, robustness, portability and ease of use for normal production personnel. In parallel with the evaluation of detection methods, considerable effort has been made to developing good, uniform contamination films to use as calibration standards. This activity within itself has presented unique challenges. The development of NIR methods for detecting and identifying contaminants has been in progress for several years. Cooperative efforts between the University, NASA, and Thiokol Corporation has shown some useful results for implementation in both laboratory and on-line procedures.

Workman, Gary L.↗

Inspection Technology Advancements for Hanford Double Shell Tank Integrity Verification - 16150

The Hanford double-shell tanks (DSTs) were constructed in southeastern Washington State between 1968 and 1986 to store nuclear waste. Most of the tank waste came from the Hanford nuclear weapons program, which has been stopped for more than 25 years. The tanks will be needed for many years to come until suitable vitrification and permanent storage solutions are developed. These tanks are nominally 45 ft. deep from the dome peak to the floor. The inner tank is nominally 75 ft. dia. and the outer tank is nominally 80 ft. dia., leaving a 2.5 ft. annulus between the two side tank walls. The waste management program (under direction of Washington River Protection Solutions, WRPS) manages inspections of these DSTs from the annulus to justify their continued safe service and to avoid the high cost of new replacement tanks. Over time, the Hanford Tank Farm contractors, currently WRPS, have increased their ultrasound inspections of these tanks. Pacific Northwest National Laboratory has worked with the Hanford Tank Farm contractors for more than 15 years to advance applicable tank nondestructive inspection technology for improved performance and cost reduction. Past, present, and planned technology advancements are addressed in this paper, including tank wall ultrasonic testing examination, extreme value statistical analysis, phased array for the tank wall, transmit/receive tandem synthetic aperture focusing technique knuckle examination, and electromagnetic acoustic transducer screening of the tank wall including mill-scale compensation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Monte Carlo based spent fuel analysis safeguards strategy assessment

Safeguarding nuclear material involves the detection of diversions of significant quantities of nuclear materials, and the deterrence of such diversions by the risk of early detection. There are a variety of motivations for quantifying plutonium in spent fuel assemblies by means of nondestructive assay (NDA) including the following: strengthening the capabilities of the International Atomic Energy Agencies ability to safeguards nuclear facilities, shipper/receiver difference, input accountability at reprocessing facilities and burnup credit at repositories. Many NDA techniques exist for measuring signatures from spent fuel; however, no single NDA technique can, in isolation, quantify elemental plutonium and other actinides of interest in spent fuel. A study has been undertaken to determine the best integrated combination of cost effective techniques for quantifying plutonium mass in spent fuel for nuclear safeguards. A standardized assessment process was developed to compare the effective merits and faults of 12 different detection techniques in order to integrate a few techniques and to down-select among the techniques in preparation for experiments. The process involves generating a basis burnup/enrichment/cooling time dependent spent fuel assembly library, creating diversion scenarios, developing detector models and quantifying the capability of each NDA technique. Because hundreds of input and output files must be managed in the couplings of data transitions for the different facets of the assessment process, a graphical user interface (GUI) was development that automates the process. This GUI allows users to visually create diversion scenarios with varied replacement materials, and generate a MCNPX fixed source detector assessment input file. The end result of the assembly library assessment is to select a set of common source terms and diversion scenarios for quantifying the capability of each of the 12 NDA techniques. We present here the generalized assessment process, the techniques employed to automate the coupled facets of the assessment process, and the standard burnup/enrichment/cooling time dependent spent fuel assembly library. We also clearly define the diversion scenarios that will be analyzed during the standardized assessments. Though this study is currently limited to generic PWR assemblies, it is expected that the results of the assessment will yield an adequate spent fuel analysis strategy knowledge that will help the down-select process for other reactor types.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nondestructive Evaluation of Space Shuttle External Tank Foam

During launch of Shuttle Columbia, mission STS-107, a large piece of spray on foam insulation (SOFI) separated from the external tank left bipod ramp area impacting the shuttle orbiter left wing leading edge. "Analysis showed that this large piece of foam struck Columbia on the underside of the left wing after launch. Later, analysis showed that the larger piece struck Columbia on the underside of the left wing, around Reinforced Carbon-Carbon (RCC) panels 5 through 9, at 81.9 seconds after launch. Further photographic analysis revealed that the large foam piece was approximately 21 to 27 inches long and 12 to 18 inches wide and was moving at a relative velocity to the Shuttle stack of 625 to 840 feet per second (416 to 573 miles per hour) at the time of impact." This impact damaged the wing leading edge resulting in loss of orbiter thermal protection. The piece of errant foam was part of a bipod ramp which was designed to meet thermal and aerodynamic requirements in that region of the external tank (ET).

Thom, Robert L.↗

High-Throughput Microfluidics Platform for Intracellular Delivery and Sampling of Biomolecules from Live Cells

Nondestructive cell membrane permeabilization systems enable the intracellular delivery of exogenous biomolecules for cell engineering tasks as well as the temporal sampling of cytosolic contents from live cells for the analysis of dynamic processes. Here, in this paper, we report a microwell array format live-cell analysis device (LCAD) that can perform localized-electroporation induced membrane permeabilization, for cellular delivery or sampling, and directly interfaces with surface-based biosensors for analyzing the extracted contents. We demonstrate the capabilities of the LCAD via an automated high-throughput workflow for multimodal analysis of live-cell dynamics, consisting of quantitative measurements of enzyme activity using self-assembled monolayers for MALDI mass spectrometry (SAMDI) and deep-learning enhanced imaging and analysis. By combining a fabrication protocol that enables robust assembly and operation of multilayer devices with embedded gold electrodes and an automated imaging workflow, we successfully deliver functional molecules (plasmid and siRNA) into live cells at multiple time-points and track their effect on gene expression and cell morphology temporally. Furthermore, we report sampling performance enhancements, achieving saturation levels of protein tyrosine phosphatase activity measured from as few as 60 cells, and demonstrate control over the amount of sampled contents by optimization of electroporation parameters using a lumped model. Lastly, we investigate the implications of cell morphology on electroporation-induced sampling of fluorescent molecules using a deep-learning enhanced image analysis workflow.

59 BASIC BIOLOGICAL SCIENCES↗

Nondestructive Testing As a Tool in the Space Shuttle Columbia Accident Investigation

Nondestructive testing (NDT) played a crucial role in determining the Columbia tragedy's cause. Over 84,000 pieces of debris were recovered; hundreds were subsequently subjected to NDT and materials analysis. Visual NDT of the debris revealed localized areas of damage such as erosion, excessive heating, knife edging and mechanical damage. Three-dimensional reconstructions were made of the left wing leading edge, utilizing a tripod-mounted laser scanning head and focused laser beam, and an advanced topometric optical scanner (ATOS) with digital white light to scan complex-shaped debris, producing monochrome 3-D models. Texture mapping provided a means to capture true colors of the debris and superimpose them on the scanned images. Uniform deposits were found over large portions of debris, obscuring underlying materials. To determine what was beneath, inverse radiography was enlisted. The radiographs guided investigators to where samples should be taken. To ascertain compositions, these samples were subjected to analytical testing, including energy dispersive X-ray spectroscopy and electron microprobe analysis. This combination of visual evidence, radiography, virtual reconstruction, and materials analysis allowed the forensic scientists to verify that a breach occurred in the leading edge of the left wing, the path the plasma followed, and the sequence of events that led to the loss.

McDanels, Steve↗

Hot Cell Examination of Weapons-Grade MOX Fuel

The U.S. Department of Energy has decided to dispose of a portion of the nation s surplus weapons-grade plutonium by reconstituting it into mixed oxide (MOX) fuel and irradiating it in commercial power reactors. Four lead assemblies were manufactured with weapons-grade MOX and irradiated to a maximum fuel rod burnup of 47.3 MWd/kg. As part of the fuel qualification process, five fuel rods with varying burnups and plutonium contents were selected from one of the assemblies and shipped to Oak Ridge National Laboratory for hot cell examination. This is the first hot cell examination of weapons-grade MOX fuel. The rods have been examined nondestructively with the ADEPT apparatus and are currently being destructively examined. Examinations completed to date include length measurements, visual examination, gamma scanning, profilometry, eddy-current testing, gas measurement and analysis, and optical metallography. Representative results of these examinations are reviewed and found to be consistent with predictions and with prior experience with reactor-grade MOX fuel. The results will be used to support licensing of weapons-grade MOX for batch use in commercial power reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scalable method for micro-CT analysis enables large scale quantitative characterization of brain lesions and implants

Anatomic evaluation is an important aspect of many studies in neuroscience; however, it often lacks information about the three-dimensional structure of the brain. Micro-CT imaging provides an excellent, nondestructive, method for the evaluation of brain structure, but current applications to neurophysiological or lesion studies require removal of the skull as well as hazardous chemicals, dehydration, or embedding, limiting their scalability and utility. Here we present a protocol using eosin in combination with bone decalcification to enhance contrast in the tissue and then employ monochromatic and propagation phase-contrast micro-CT imaging to enable the imaging of brain structure with the preservation of the surrounding skull. Instead of relying on descriptive, time-consuming, or subjective methods, we develop simple quantitative analyses to map the locations of recording electrodes and to characterize the presence and extent of hippocampal brain lesions.

3-D reconstruction↗