Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “model benchmarking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Comparing the Predicted Neutron Yields and Radioactivities of Two Accelerators in Taiwan: 235-MeV Proton Cyclotron and 3-GeV Electron Synchrotron - Paper 27

Two major accelerator facilities in Taiwan are about to open. The first proton treatment center equipped with a 235 MeV proton cyclotron and four gantry rooms in Linkou Chang Gung Memorial Hospital is currently under beam commissioning and clinical trials are expected to start soon. In addition, the second light source facility, named Taiwan Photon Source (TPS), in National Synchrotron Radiation Research Center is now approaching its final assembly and will be ready for beam commissioning in this year. These two facilities mark significant milestones in accelerator development and application of Taiwan. Operation of these accelerators could potentially produce intense secondary neutrons and serious material activation. Both issues are crucial and must be carefully evaluated for the purpose of radiation safety, especially in a densely populated hospital or in a crowded user experimental floor. Monte Carlo simulations with evaluated cross sections or benchmarked nuclear models are considered as the most reliable method for accelerator shielding designs or related analyses. This study predicted and compared the magnitudes of potential neutron production and induced radioactivity due to the operation of these two accelerators. For conservative consideration, the primary particle energy and full beam output were assumed to hit a thick target for maximum radiation production. In order to ensure the quality of predictions, much effort has been devoted to associated benchmark calculations, targeting those bombardment experiments involving with the same particle types and similar beam energies and targets. (authors)

43 PARTICLE ACCELERATORS↗

Non-resonant anomaly detection with background extrapolation

Complete anomaly detection strategies that are both signal sensitive and compatible with background estimation have largely focused on resonant signals. Non-resonant new physics scenarios are relatively under-explored and may arise from off-shell effects or final states with significant missing energy. In this paper, we extend a class of weakly supervised anomaly detection strategies developed for resonant physics to the non-resonant case. Machine learning models are trained to reweight, generate, or morph the background, extrapolated from a control region. A classifier is then trained in a signal region to distinguish the estimated background from the data. The new methods are demonstrated using a semi-visible jet signature as a benchmark signal model, and are shown to automatically identify the anomalous events without specifying the signal ahead of time.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-C-BRC-01: A Monte Carlo Study of Out-Of-Field Doses From Cobalt-60 Teletherapy Units Intended for Historical Correlations of Dose to Normal Tissue

Purpose: Innovations in radiotherapy treatments, such as dynamic IMRT, VMAT, and SBRT/SRS, result in larger proportions of low-dose regions where normal tissues are exposed to low doses levels. Low doses of radiation have been linked to secondary cancers and cardiac toxicities. The AAPM TG Committee No.158 entitled, ‘Measurements and Calculations of Doses outside the Treatment Volume from External-Beam Radiation Therapy’, has been formed to review the dosimetry of non-target and out-of-field exposures using experimental and computational approaches. Studies on historical patients can provide comprehensive information about secondary effects from out-of-field doses when combined with long-term patient follow-up, thus providing significant insight into projecting future outcomes of patients undergoing modern-day treatments. Methods: We present a Monte Carlo model of a Theratron-1000 cobalt-60 teletherapy unit, which historically treated patients at the University of Florida, as a means of determining doses located outside the primary beam. Experimental data for a similar Theratron-1000 was obtained at the University of Wisconsin’s ADCL to benchmark the model for out-of-field dosimetry. An Exradin A12 ion chamber and TLD100 chips were used to measure doses in an extended water phantom to 60 cm outside the primary field at 5 and 10 cm depths. Results: Comparison between simulated and experimental measurements of PDDs and lateral profiles show good agreement for in-field and out-of-field doses. At 10 cm away from the edge of a 6×6, 10×10, and 20×20 cm2 field, relative out-of-field doses were measured in the range of 0.5% to 3% of the dose measured at 5 cm depth along the CAX. Conclusion: Out-of-field doses can be as high as 90 to 180 cGy assuming historical prescription doses of 30 to 60 Gy and should be considered when correlating late effects with normal tissue dose.

60 APPLIED LIFE SCIENCES↗

Hover and Forward Flight Performance Modeling of the Ingenuity Mars Helicopter

In 2015, NASA’s Jet Propulsion Laboratory partnered with Ames Research Center, Langley Research Center, and AeroVironment to develop Ingenuity, a small coaxial helicopter capable of flying within Mars’ unique atmospheric conditions. Ingenuity was successfully deployed from its protective shroud on the underside of the Mars 2020 Perseverance Rover and has flown 17 flights on Mars as of December 2021. A number of rotorcraft analysis tools were utilized, and a series of experimental tests were performed to ready Ingenuity for its launch with the Perseverance Rover in July 2020. In this paper, RotCFD, a Reynolds-averaged Navier-Stokes flow solver, is used to model Ingenuity in hover and forward flight for the purposes of validating tools to aid in the development of a future generation of Mars rotorcraft. The results from the RotCFD modeling are benchmarked against results from hover performance tests of the Ingenuity prototype in the 25-Foot Space Simulator at the Jet Propulsion Laboratory and are also compared to hover and forward flight predictions made by CAMRAD II, a well-known comprehensive rotorcraft analysis code. Surrogate performance models are trained to obtain a set of trimmed rotor settings for Ingenuity at different forward flight speeds, which are then used as inputs for the RotCFD forward flight simulations. Additionally, a study of the airframe-rotor interaction and a study of the aerodynamics of the individual airframe components of Ingenuity in forward flight are performed. Finally, to better understand performance predictions by RotCFD and CAMRAD II, a study is conducted on how sectional angles of attack in each code vary with radial station and azimuth.

Hover↗

SU-E-T-555: A Protontherapy Inverse Treatment Planning System Prototype with Linear Energy Transfer (LET) Optimization

Purpose: Develop and benchmark an inverse treatment planning system (TPS) for proton radiotherapy integrating fast analytical dose and LET calculations in patient geometries and a dual objective function with both dose and LET components, enabling us to apply optimization techniques to improve the predicted outcome of treatments based on radiobiological models. Methods: The software package was developed in MATLAB and implements a fluence-dose calculation technique based on a pencil beam model for dose calculations and a 3D LET model based on the extension of the LET in the radial direction as a function of the predicted radiological pathway. Both models were benchmarked against commissioning data from our institution, dose calculations performed with a commercial treatment planning system and Monte Carlo simulations. The optimization is based on the adaptive simulated annealing approach . Results: The dose and LET calculations were tested in a water phantom and several real patient treatments. The pass rate for the gamma index analysis (3%/3mm) test was above 90% for all test cases analyzed, and the calculation time was of the order of seconds. The inverse planning module produced plans with a significantly higher mean LET in the target compared to traditional plans, without any loss of target coverage. The clinical relevance of this improvement is under consideration . Conclusion: The developed treatment planning system is a valuable clinical and research tool that enables us to incorporate LET effects into proton radiotherapy planning in a streamlined fashion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton-Induced Transients and Charge Collection Mechanisms in a LWlR HgCdTe Focal Plane Array

Low noise performance of IR detectors is required, even in the presence of charged particles. Galactic cosmic rays, trapped protons & solar energetic particles. Particle induced transients identified as an important source of noise on ESA's ISO satellite. Also observed on NICMOS Instrument on NASA% Hubble Space Telescope. Tools to analyse particle induced transients have been developed. To date, comparisons of model have been made to flight data for a HgCdTe array exposed to trapped protons, and to a Si array exposed to laboratory protons. We report ground based proton transient measurements in a modem LWlR HgCdTe array operating under cryogenic conditions. Demonstration of charge collection mechanisms. Provide benchmarks for modeling tools.

Marshall, Paul↗

Defect sink characteristics of specific grain boundary types in 304 stainless steels under high dose neutron environments

Radiation induced segregation (RIS) is a well-studied phenomena which occurs in many structurally relevant nuclear materials including austenitic stainless steels. RIS occurs due to solute atoms preferentially coupling to mobile point defect fluxes that migrate and interact with defect sinks. Here, a 304 stainless steel was neutron irradiated up to 47.1 dpa at 320 °C. Investigations into the RIS response at specific grain boundary types were utilized to determine the sink characteristics of different boundary types as a function of irradiation dose. A rate theory model built on the foundation of the modified inverse Kirkendall (MIK) model is proposed and benchmarked to the experimental results. This model, termed the GiMIK model, includes alterations in the boundary conditions based on grain boundary structure and includes expressions for interstitial binding. This investigation, through experiment and modeling, found specific grain boundary structures exhibit unique defect sink characteristics depending on their local structure. Such interactions were found to be consistent across all doses investigated and had larger global implications including precipitation of Ni-Si clusters near different grain boundary types.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Nuclear Data and Cross Section Testing Using ENDF/B-VIII.0

With the release of the Evaluated Nuclear Data File (ENDF)/B-VIII.0 library, nuclear criticality safety practitioners and engineers have access to the latest cross section sets available for their analyses. However, these cross sections must be rigorously tested and validated to ensure that the nuclear data are responsive to the needs of the individuals responsible for developing, implementing, and maintaining computational tools for criticality safety applications. Thus, the ENDF/B-VIII.0 library is tested and validated with a large collection of experiments that were vetted by the International Criticality Safety Benchmark Evaluation Project and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments. A selection of benchmark experiments for use within the criticality safety community were prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID), which is maintained by the Nuclear Energy and Fuel Cycle Division at Oak Ridge National Laboratory. The performance of the ENDF/B-VIII.0 library is assessed by using VALID models of benchmark experiments with the beta 12 version of SCALE 6.3 KENO V.a and KENO-VI Monte Carlo codes. The performance is compared with the results obtained from with the ENDF/B-VII.1 library. This report considers multigroup (MG) and continuous energy (CE) formats of the ENDF/B-VIII.0 and -VII.1 libraries. The benchmark experiments within VALID that validate the ENDF/B-VIII.0 library cover 15 broad system categories by using a range of fissile materials, uranium enrichments, plutonium isotopic vectors, and mixed uranium/plutonium systems. These forms are represented as metals, solutions, or various arrays of rods or plates that cover a variety of neutron energy spectra: thermal, fast, mixed, and intermediate. Over 600 cases were considered for use with the KENO V.a and KENO-VI codes with the ENDF/B-VIII.0 library. The results of the Monte Carlo comparison of ENDF/B-VIII.0 to ENDF/B-VII.1 with both KENO V.a and KENO-VI indicate that there is a less than 0.53% Δk difference between the bias of calculated k eff from the expected values. The CE ENDF/B-VIII.0 library results in smaller magnitude biases than the ENDF/B-VII.1 data for HEU-MET-FAST, HEU-SOL-THERM, IEU-MET-FAST, LEU-SOL-THERM, PU-SOL-THERM, and U233-MET-FAST systems, while the MG results yielded smaller magnitude biases for HEU-MET-FAST, HEU-SOL-THERM, IEU-MET-FAST, LEU-COMP-THERM, LEU-SOL THERM, MIX-COMP-FAST, and U233-MET-FAST systems. Most notable are the adjustments to the plutonium and 233 U cross section data, which has resulted in noticeably lower biases in the ENDF/B VIII.0 results for the mixed, plutonium, and 233 U systems. Results of the sensitivity data file comparison generated from TSUNAMI-3D for selected VALID cases for the ENDF/B-VIII.0 library indicate a very high level of agreement with correlation coefficients of the effect of nuclear data uncertainty on k eff (the c k integral parameter) all above 0.99. This indicates that cases with the ENDF/B-VIII.0 library would see very similar responses to any nuclear data errors or change as those with the ENDF/B-VII.1 library.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-T-578: MCEBRT, A Monte Carlo Code for External Beam Treatment Plan Verifications

Purpose: Present a new Monte Carlo code (MCEBRT) for patient-specific dose calculations in external beam radiotherapy. The code MLC model is benchmarked and real patient plans are re-calculated using MCEBRT and compared with commercial TPS. Methods: MCEBRT is based on the GEPTS system (Med. Phys. 29 (2002) 835–846). Phase space data generated for Varian linac photon beams (6 – 15 MV) are used as source term. MCEBRT uses a realistic MLC model (tongue and groove, rounded ends). Patient CT and DICOM RT files are used to generate a 3D patient phantom and simulate the treatment configuration (gantry, collimator and couch angles; jaw positions; MLC sequences; MUs). MCEBRT dose distributions and DVHs are compared with those from TPS in absolute way (Gy). Results: Calculations based on the developed MLC model closely matches transmission measurements (pin-point ionization chamber at selected positions and film for lateral dose profile). See Fig.1. Dose calculations for two clinical cases (whole brain irradiation with opposed beams and lung case with eight fields) are carried out and outcomes are compared with the Eclipse AAA algorithm. Good agreement is observed for the brain case (Figs 2-3) except at the surface where MCEBRT dose can be higher by 20%. This is due to better modeling of electron contamination by MCEBRT. For the lung case an overall good agreement (91% gamma index passing rate with 3%/3mm DTA criterion) is observed (Fig.4) but dose in lung can be over-estimated by up to 10% by AAA (Fig.5). CTV and PTV DVHs from TPS and MCEBRT are nevertheless close (Fig.6). Conclusion: A new Monte Carlo code is developed for plan verification. Contrary to phantombased QA measurements, MCEBRT simulate the exact patient geometry and tissue composition. MCEBRT can be used as extra verification layer for plans where surface dose and tissue heterogeneity are an issue.

60 APPLIED LIFE SCIENCES↗

Computation of Turbulent Recirculating Flow in Channels, and for Impingement Cooling

Fully elliptic forms of the transport equations have been solved numerically for two flow configurations. The first is turbulent flow in a channel with transverse rectangular ribs, and the second is impingement cooling of a plane surface. Both flows are relevant to proposed designs for active cooling of hypersonic vehicles using supercritical hydrogen as the coolant. Flow downstream of an abrupt pipe expansion and of a backward-facing step were also solved with various near-wall turbulence models as benchmark problems. A simple form of periodicity boundary condition was used for the channel flow with transverse rectangular ribs. The effects of various parameters on heat transfer in channel flow with transverse ribs and in impingement cooling were investigated using the Yap modified Jones and Launder low Reynolds number k-epsilon turbulence model. For the channel flow, predictions were in adequate agreement with experiment for constant property flow, with the results for friction superior to those for heat transfer. For impingement cooling, the agreement with experiment was generally good, but the results suggest that improved modelling of the dissipation rate of turbulence kinetic energy is required in order to obtain improved heat transfer prediction, especially near the stagnation point. The k-epsilon turbulence model was used to predict the mean flow and heat transfer for constant and variable property flows. The effect of variable properties for channel flow was investigated using the same turbulence model, but comparison with experiment yielded no clear conclusions. Also, the wall function method was modified for use in the variable properties flow with a non-adiabatic surface, and an empirical model is suggested to correctly account for the behavior of the viscous sublayer with heating.

Chang, Byong Hoon↗

Relative Biological Effectiveness of Carbon Ions in a Rat Prostate Carcinoma In Vivo: Comparison of 1, 2, and 6 Fractions

Purpose: To determine the relative biological effectiveness (RBE) and the effective α/β ratio for local tumor control of a radioresistant rat prostate tumor (Dunning subline R3327-AT1) after 6 fractions of carbon ions and photons. Methods and Materials: A total of 82 animals with tumors in the distal thigh were treated with 6 fractions of either photons or carbon ions, by use of increasing dose levels and a 2-cm spread-out Bragg peak. Endpoints of the study were local control (no tumor recurrence within 300 days) and volumetric changes after irradiation. The resulting values for dose at 50% tumor control probability were used to determine RBE values. Including data for 1 and 2 fractions from a previous study, we estimated α/β ratios. Results: For 6 fractions, the values for dose at 50% tumor control probability were 116.6 ± 3.0 Gy for photons and 43.7 ± 2.3 Gy for carbon ions and the resulting RBE was 2.67 ± 0.15. The α/β ratio was 84.7 ± 13.8 Gy for photons and 66.0 ± 21.0 Gy for carbon ions. Using these data together with the linear-quadratic model, we estimated the maximum RBE to be 2.88 ± 0.27. Conclusions: The study confirmed the increased effectiveness of carbon ions relative to photons over the whole dose range for a highly radioresistant tumor. The maximum RBE below 3 is in line with other published in vivo data. The RBE values may be used to benchmark RBE models. Hypoxia seems to have a major impact on the radiation response, although this still has to be confirmed by dedicated experiments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-770: Tumor Control in Ion Beam Radiotherapy with Different Ions in Presence of Hypoxia

Purpose: The reduced concentration of oxygen in cells (hypoxia) results in a lower cell death rate after irradiation that can lead to treatment failure. The effect can be expressed by the oxygen enhancement ratio (OER). So far, only few attempts to include OER in treatment planning for ion beam therapy were made, which are based on the dose averaged LET estimates and do not distinguish among ion species and fractionation schemes. To overcome these limitations, we implemented a new OER model and used it to estimate tumor control in clinical cases. Methods: The model, based on the microdosimetric kinetic model, was benchmarked with in-vitro data from different ions irradiation. It was included in the simulation of treatments of a set of clinical cases (glioblastoma) using p, Li, He, C and O ion beams. Tumor Control Probability (TCP) was estimated as a function of oxygen partial pressure, dose per fraction and primary ion type. Results: The modelized OER was found to be strongly dependent on both LET and ion type, and showed a decreasing OER for increasing dose per fraction with a slope that depends on the LET and ion type, in good agreement with the experimental data. In the clinical cases studied, an increase in TCP by increasing ion charge and dose per fraction (more than 30% variation from p to O for moderate hypoxia) was found. Higher OER decrease rates as function of dose per fraction were found for lighter ions (up to 20% varying from 2 to 8 Gy(RBE)). Conclusions: A novel modeling of the OER that explicitly includes the dependence on ion type and dose per fraction was implemented. The model was exploited to evaluate the impact of hypoxia in ion beam radiotherapy, facilitating the identification of the treatment condition optimality, including fractionation scheme and ion type.

60 APPLIED LIFE SCIENCES↗

Phase Field Modeling of Crystallographic Corrosion Pits

The modeling of corrosion to understand and predict corrosion behavior is a topical issue. Here, a 3D phase field model is developed to simulate the pit morphology, primarily focusing on crystallographic pits. A crystallographic function is employed to incorporate different corrosion rates for different crystallographic planes. The model is benchmarked and validated against an analytical solution for a simple case. 3D crystallographic pits in a single crystal are simulated and the effect of substrate orientation on the pit morphology is studied. The crystallographic pit morphology changes significantly with the substrate orientation and these morphologies have a symmetry consistent with the substrate orientation. This first 3D phase field model of crystallographic pits will help in predicting the intricate shapes of pits, thereby, pushing the frontiers of pitting corrosion modeling.

36 MATERIALS SCIENCE↗

Improvements to the Modeling of the TREAT Reactor and Experiments

This paper summarizes the latest improvements and lessons learned from the modeling and simulation of the transient test reactor at Idaho National Laboratory using the MAM- MOTH reactor physics application. MAMMOTH is a MOOSE-based, Finite Element Method application that specializes in the analysis of the spatial dynamics behavior of nuclear reactors. Since early 2018 several transient tests have been conducted at TREAT, thus providing the opportunity to apply and benchmark modern modeling and simulation tools. MAMMOTH was used to provide predictions of the power coupling factor between the core and the experiment for various experiments. Even though the power coupling factor predictions agree very well with the experimental data, within the bounds of the experimental uncertainty, one shortcoming was the underprediction of the total energy deposited in the core and in the experiment. Determination of the sources for this discrepancy are ongoing, but several key problems have been identified and resolved, thus providing valuable insights for future research. This paper discusses several of these lessons learned. First, the heat capacity data for the TREAT fuel has some significant problems due to limitations of the measurement techniques used circa 1960s. The sensitivity of the peak power and the total energy deposition to various representations of the heat capacity is approximately 5%. Second, the effects of the biological shield and thermal column on the modeling of the core are non-negligible, since they affect the mean generation time and the effective reflection of neutrons back into the core, which is suspected to be important during the core heat up. Matching the reactor period resolves the fact that the reduced spatial domain used in the MAMMOTH model underpredicts the mean generation time. The neutron reflection from these regions is marginally improved with the use of an albedo boundary condition. Third, modeling of the control rod movement with a multi-scheme method is introduced and its current limitations are exposed. Fourth, we explore the effects of using a homogenized model with Superhomogenization equivalence and how that differs from fully heterogeneous simulations. Finally, the energy condensation effects for this graphite core are significant. Solutions with 10 and 26 energy groups show the benefits of using a finer coarse group structure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Multi-Plume Eddy-Diffusivity/Mass-Flux (EDMF) Unified Parameterization: Stratocumulus and the Transition to Cumulus Boundary Layers

The primary objective of this project is to mitigate inaccuracies and biases in subtropical boundary layer clouds, particularly in oceanic upwelling regions. Our approach began with developing a novel unified boundary layer and convection parameterization, utilizing the multi-plume Eddy-Diffusivity/Mass-Flux (EDMF) framework. We evaluated this advanced stochastic multi-plume EDMF parameterization in an independent single-column model (SCM), benchmarking it against Large-Eddy Simulation (LES) reference data and satellite observations. This version of the EDMF is designed to seamlessly represent a continuum of convective processes, from dry and cloudy boundary layer convection to deep moist convection. We progressed by integrating the stochastic multi-plume EDMF scheme into the Simple Cloud-Resolving E3SM (Energy Exascale Earth System Model) Atmosphere model (SCREAM), coupling it with the SHOC (Simplified Higher-Order Closure) turbulence and convection scheme. This combined approach was then evaluated against LES reference data for both maritime and continental shallow convection within the E3SM SCM.

54 ENVIRONMENTAL SCIENCES↗

2018 U.S. Utility-Scale Photovoltaics-Plus-Energy Storage System Costs Benchmark

Market growth for utility-scale photovoltaic (PV) systems has been rapid for several years. Today, with the cost reductions of energy storage technologies, the combining PV and energy storage has become feasible and beneficial, especially for the areas that have only PV standalone systems and need to shift the peak load to meet electricity demand in the evening. Overall, utility-scale PV plus energy storage systems can provide dispatchable energy and reliable capacity. This study details cost factors, including labor costs, material costs, overhead, and permitting costs using a system-level bottom-up cost modeling approach. We use this model to benchmark PV-plus-storage installation system cost and identify the cost difference for AC- and DC-coupled systems and duration variation. Finally, we assess the cost reduction opportunities of colocating PV systems with energy storage systems in order to indicate the possible economic impacts of the PV-plus-storage configuration and help future research and development (R&D) effects in the context of U.S. energy storage policymaking.

14 SOLAR ENERGY↗

2018 U.S. Utility-Scale Photovoltaics-Plus-Energy Storage System Costs Benchmark

Market growth for utility-scale photovoltaic (PV) systems has been rapid for several years. Today, with the cost reductions of energy storage technologies, the combining PV and energy storage has become feasible and beneficial, especially for the areas that have only PV standalone systems and need to shift the peak load to meet electricity demand in the evening. Overall, utility-scale PV plus energy storage systems can provide dispatchable energy and reliable capacity. This study details cost factors, including labor costs, material costs, overhead, and permitting costs using a system-level bottom-up cost modeling approach. We use this model to benchmark PV-plus-storage installation system cost and identify the cost difference for AC- and DC-coupled systems and duration variation. Finally, we assess the cost reduction opportunities of colocating PV systems with energy storage systems in order to indicate the possible economic impacts of the PV-plus-storage configuration and help future research and development (R&D) effects in the context of U.S. energy storage policymaking.

14 SOLAR ENERGY↗