Lunar Excavation Experiments in Simulant Soil Test Beds-Revisiting the Surveyor Geotechnical Data

(1) Establishing ISRU technologies on planetary bodies is an important long-term goal of NASA; (2) Excavation is a key component of these ISRU processes; (3) Lack of flight data relevant to lunar excavation; (4) Existing models of the excavation-cutting phenomenon give varying results; (5) The lack of predictive models of the dynamic behavior of soils in excavation implements is a major driver for these studies; and (6) Objective: Need to develop robust models of excavation cutting phenomena that generate predictive capabilities to aid the designer and engineer.

Agui, Juan H.↗

Operation of a Giant Magnetoresistive (GMR) Digital Isolator, Type IL510, Under Extreme Temperatures

A relatively new type of signal isolation based on Giant Magnetoresistive (GMR) technology was investigated for potential use in harsh temperature environments. Operational characteristics of the 2Mbps single channel, IL510-Series commercial-off-the-shelf (COTS) digital isolator chip was obtained under extreme temperature exposure and thermal cycling in the range of -190 C to +120 C. The isolator was evaluated in terms of its output signal delivery and stability, output rise (t(sub r)) and fall times (t(sub f)), and propagation delays at 50% level between input and output during low to high (t(sub PLH)) and high to low (t(sub PHL)) transitions. The device performed very well throughout the entire test temperature range as no significant changes occurred either in its function or in its output signal timing characteristics. The limited thermal cycling, which comprised of 12 cycles between -190 C and +120 C, also had no influence on its performance. In addition, the device packaging underwent no structural damage due to the extreme temperature exposure. These preliminary results indicate that this semiconductor chip has the potential for use in a temperature range that extends beyond its specified regime. Additional and more comprehensive testing, however, is required to establish its operation and reliability and to determine its suitability for long-term use in space exploration missions.

Patterson, Richard↗

Matrix dominated stress/strain behavior in polymeric composites: Effects of hold time, nonlinearity and rate dependency

In order to understand matrix dominated behavior in laminated polymer matrix composites, an elastic/viscoplastic constitutive model was developed and used to predict stress strain behavior of off-axis and angle-ply symmetric laminates under in-plane, tensile axial loading. The model was validated for short duration tests at elevated temperatures. Short term stress relaxation and short term creep, strain rate sensitivity, and material nonlinearity were accounted for. The testing times were extended for longer durations, and periods of creep and stress relaxation were used to investigate the ability of the model to account for long term behavior. The model generally underestimated the total change in strain and stress for both long term creep and long term relaxation respectively.

Gates, Thomas S.↗

Evaluation of Polymer Hermetically Sealed Tantalum Capacitors

Polymer cathode tantalum capacitors have lower ESR (equivalent series resistance) compared to other types of tantalum capacitors and for this reason have gained popularity in the electronics design community. Their use allows improved performance of power supply systems along with substantial reduction of size and weight of the components used. However, these parts have poor thermal stability and can degrade in humid environments. Polymer hermetically sealed (PHS) capacitors avoid problems related to environmental degradation of molded case parts and can potentially replace current wet and solid hermetically sealed capacitors. In this work, PHS capacitors manufactured per DLA LAM DWG#13030 are evaluated for space applications. Several lots of capacitors manufactured over period from 2010 to 2014 were tested for the consistency of performance, electrical and thermal characteristics, highly accelerated life testing, and robustness under reverse bias and random vibration conditions. Special attention was given to analysis of leakage currents and the effect of long-term high temperature storage on capacitors in as is condition and after hermeticity loss. The results show that PHS capacitors might be especially effective for low-temperature applications or for system requiring a cold start-up. Additional screening and qualification testing have been recommended to assure the necessary quality of capacitors for space projects.

ferrite beads↗

Measurements of Humidity in the Atmosphere: Validation Experiments (MOHAVE I and MOHAVE II). Results Overview and Implication for the Long-Term Lidar Monitoring of Water Vapor in the UT/LS

1. MOHAVE+MOHAVE II = very successful. 2. MOHAVE -> Fluorescence was found to be inherent to all three participating lidars. 3. MOHAVE II -> Fluorescence was removed and agreement with CFH was extremely good up to 16-18 km altitude. 4. MOHAVE II -> Calibration tests revealed unsuspected shortfalls of widely used techniques, with important implications for their applicability to longterm measurements. 5. A factor of 5 in future lidar signal-to-noise ratio is reasonably achievable. When this level is achieved water vapor Raman lidar will become a key instrument for the long-term monitoring of water vapor in the UT/LS

MOHAVE II↗

Process Development and Testing for Lunar Habitats

Non-metallic composites are appealing for Lunar habitats due to their low specific weight and contribution to passive radiation shielding. This application of composite materials presents notable challenges, however: flammability risks are higher due to elevated oxygen levels expected in habitat structures and absorbed radiation can cause damage long-term. The Materials and Processes Laboratory at Marshall Space Flight Center awarded funding for an internal research and development study which included fabrication and testing of composite materials for Lunar habitats. Composite layups used carbon fiber or ultra-high molecular weight polyethylene reinforcement and a variety of polymer matrices. Pre-impregnated fabric was autoclave cured; however, novel coatings were incorporated during select layups. Samples from each panel were used for screening-level flammability testing (ASTM D 2863) and combined vacuum ultraviolet and electron irradiation followed by tension testing (ASTM D5766). Two of the tested composite materials exceeded a 37% limiting oxygen index. Material property degradation for a 10 year simulated radiation dose was minimal in most cases.

manufacturing↗

Seventeen Ketogenic steroids excretion in crewmen in a 90-day manned test of an advanced regenerative life support system

Seventeen KGS (17-Ketogenic steroids) and Na/K were determined in 19 urine specimens collected by each of 4 crewmen during the 90-day test. The specimens represented 10% aliquots of 24-hour collections stored frozen onboard the simulator until passthrough. Electrolytes were analyzed immediately after sample passthrough while the steroids were determined post-test on aliquots of the original sample held at 203 K. Steroid data was corrected for body weight and also for analytical variation in the laboratory urine pool control. Long-term nonspecific responses to low-level stress appear to be reflected by the individual and group mean 17-KGS excretion patterns. The first 39 and the last 20 days of the test were significantly different--and presumably more stressful to the crew--than the period from days 39 to 67. Reduction of adrenocortical function during the mid-test phase is attributed to either an adaptation to chronic or intermittent stress or was the result of an actual reduction in the operational demands of the test during this time. Most remarkable of the metabolic findings is the prevalance of high Na/K ratios and an abrupt peak on day 74 for all 4 crewmen.

Myers, D. J.↗

Rodent Studies of Cardiovascular Deconditioning

Changes in blood pressure can occur for two reasons: 1) A decrease in cardiac output resulting from the altered contractility of the heart or through changes in venous filling pressure via the Frank Starling mechanism or; 2) A change in systemic vascular resistance. The observed changes in cardiac output and blood pressure after long term space flight cannot be entirely explained through changes in contractility or heart rate alone. Therefore, alterations in filling pressure mediated through changes in systemic venous capacitance and arterial resistance function may be important determinants of cardiac output and blood pressure after long term space flight. Our laboratory and previous studies have shown the importance of veno-constriction mediated by the carotid sinus baroreceptor reflex system on overall circulatory homeostasis and in the regulation of cardiac output. Our proposed experiments test the overall hypothesis that alterations in venous capacitance function and arterial resistance by the carotid sinus baroreceptor reflex system are an important determinant of the cardiac output and blood pressure response seen in astronauts after returning to earth from long term exposure to microgravity. This hypothesis is important to our overall understanding of circulatory adjustments made during long term space flight. It also provides a framework for investigating counter measures to reduce the incidence of orthostatic hypotension caused by an attenuation of cardiac output. We continue to use hind limb unweighted (HLU) rat model to simulate the patho physiological effects as they relate to cardiovascular deconditioning in microgravity. We have used this model to address the hypothesis that microgravity induced cardiovascular deconditioning results in impaired vascular responses and that these impaired vascular responses result from abnormal alpha-1 AR signaling. The impaired vascular reactivity results in attenuated blood pressure and cardiac output responses to an orthostatic challenge. We have used in vitro vascular reactivity assays to explore abnormalities in vascular responses in vessels from HLU animals and, cardiac output (CO), blood pressure (BP) and heart rate (HR) measurements to characterize changes in hemodynamics following HLU.

Shoukas, Artin A.↗

Large-Scale Spacecraft Fire Safety Tests

An international collaborative program is underway to address open issues in spacecraft fire safety. Because of limited access to long-term low-gravity conditions and the small volume generally allotted for these experiments, there have been relatively few experiments that directly study spacecraft fire safety under low-gravity conditions. Furthermore, none of these experiments have studied sample sizes and environment conditions typical of those expected in a spacecraft fire. The major constraint has been the size of the sample, with prior experiments limited to samples of the order of 10 cm in length and width or smaller. This lack of experimental data forces spacecraft designers to base their designs and safety precautions on 1-g understanding of flame spread, fire detection, and suppression. However, low-gravity combustion research has demonstrated substantial differences in flame behavior in low-gravity. This, combined with the differences caused by the confined spacecraft environment, necessitates practical scale spacecraft fire safety research to mitigate risks for future space missions. To address this issue, a large-scale spacecraft fire experiment is under development by NASA and an international team of investigators. This poster presents the objectives, status, and concept of this collaborative international project (Saffire). The project plan is to conduct fire safety experiments on three sequential flights of an unmanned ISS re-supply spacecraft (the Orbital Cygnus vehicle) after they have completed their delivery of cargo to the ISS and have begun their return journeys to earth. On two flights (Saffire-1 and Saffire-3), the experiment will consist of a flame spread test involving a meter-scale sample ignited in the pressurized volume of the spacecraft and allowed to burn to completion while measurements are made. On one of the flights (Saffire-2), 9 smaller (5 x 30 cm) samples will be tested to evaluate NASAs material flammability screening tests. The first flight (Saffire-1) is scheduled for July 2015 with the other two following at six-month intervals. A computer modeling effort will complement the experimental effort. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. This will facilitate the first examination of fire behavior on a scale that is relevant to spacecraft fire safety and will provide unique data for fire model validation.

Combustion↗

Charging Experiments and Filtration Testing on Facemask Materials: Towards Goals of Full Performance Restoration of Used N95 Masks and Enhancement of Common-Fabric Facemasks

Different techniques have been developed for sanitizing N95 masks while retaining whatever charge remains on them. However, these sanitizing methods do not address the fact that the electrical charge, filtration efficacy, and breathability of such masks may be expected to degrade during long-term use based on mechanisms known in the literature. In this study, approaches to electrically (re)charging facemask filter materials were explored in response to the COVID-19 induced shortage of N95 masks. The effort consisted of charging experiments followed by filtration testing conducted at the coupon level during a month-long period (May 2020). The main focus of the work was to develop a recharging technique which could eventually be adapted and used as part of a broader full-performance restoration process for used N95 masks, e.g., which might employ simple washing by alcohol or soapy water as a preceding step for sanitization and declogging. Most tested coupons were therefore nonwoven meltblown fibrous polypropylene (PP) filter media extracted from decades old N95 masks. Keeping in mind commonly used cloth facemasks, limited trials were also performed with some commercially available fabrics. Charging was done at elevated temperature and was followed by cooling to freeze in the applied charges produced from corona discharges using different electrode configurations and parameter combinations, or from triboelectric rubbing. Charging was also focused on using potentially scalable equipment, e.g., Van de Graaff generators or consumer ionic hair products. Some degree of success was achieved with one of the fabrics and the PP filter media which was first purposefully discharged to have typical filtration efficiency (FE) of ~35%. Numerous attempts at corona charging discharged media resulted in filtration efficiency (FE) ≥ 80 – 85%. Some measure of charge robustness was also established via stable performance during loading testing. However, results where FE ≥ 90% were not reliably repeatable and no results met the FE ≥ 95% goal due to shortcomings of the charging process. The best three trials for PP media statistically met the FE ≥ 90% criteria, amounted to a small percentage of the trials relying on an ionic hair dryer, and are attributed to good embedding of charges via aerodynamic force. Triboelectric charging significantly enhanced the viability of one of the polyester fabrics –measured FE increased from 19% up to 46% while maintaining a reasonably low pressure drop.

N95↗

The MIST (Minus Integration and Subsystems Test) Laboratory: A testbed for the MIUS (Modular Integrated Utility System) program

The MIUS program develops an economically feasible integrated utility system. The MIUS concept integrates utility services in order to achieve resource, energy and environmental benefits. A testbed integrated utility system, called the MIST laboratory, was completed early in 1974 and has begun a long term program to develop data for MIUS. A description of the MIST is presented and the critical design issues which can only be verified by test, are discussed in detail.

Beckham, W. S., Jr.↗

Simulated Space Environment Effects on the Blocking Force of Silicone Adhesive

The International Space Station (ISS) solar arrays utilize MD-944 diode tape to protect the underlying diodes in the solar array panel circuit and also provide thermal conditioning and mechanical support. The diode tape consists of silicone pressure sensitive adhesive (Dow Coming QC-7725) with a protective Kapton over-layer. On-orbit, the Kapton over-layer will erode under exposure to atomic oxygen (AO) and the underlying exposed silicone adhesive will ultimately convert, under additional AO exposure, to a glass like silicate. The current operational plan is to retract ISS solar array P6 and leave it stored under load for a long duration (6 months or more) during ISS assembly. With the Kapton over-layer eroded away, the exposed silicone adhesive must not cause the solar array to stick to itself or cause the solar array to fail during redeployment. Previous testing by Lockheed-Martin Space Systems (LMSS) characterized silicone blocking following exposure to low energy atomic oxygen (AO) in an asher facility, but this is believed to be conservative. An additional series of tests was performed by the Environmental Effects Group at MSFC under direction from the ISS Program Office Environments Team. This test series included high energy AO (5 eV), near ultraviolet (NUV) radiation and ionizing radiation, singly and in combination. Additional samples were exposed to thermal energy AO (<0.1 ev) for comparison to the LMSS tests. Diode tape samples were exposed to each environment constituent individually, put under preload for seven days and then the resulting blocking force was measured using a tensile machine. Additional samples were exposed to AO, NUV and electrons in series and then put under long term (three to ten months) preload to determine the effect of preload duration on the resulting blocking force of the silicone-to-silicone bond. Test results indicate that high energy AO, ultraviolet radiation and electron ionizing radiation exposure all reduce the blocking force for a silicone-to-silicone bond. AO exposure produces the most significant reduction in blocking force.

Boeder, Paul↗

Proceedings of the Symposium on Long-Life Hardware for Space

Two-volume edition of the papers of the symposium is described. It is divided into six sections - parts, materials, management, system testing, component design, and system test. Material presented focuses attention on problems created by the increased complexity of technology and long-term mission requirements.

Source record↗

Experimental evaluation of a fixed collector employing vee-trough concentrator and vacuum tube receivers

A test bed for experimental evaluation of a fixed solar collector which combines an evacuated glass tube solar receiver with a flat plate/black chrome plated copper absorber and an asymmetric vee-trough concentrator was designed and constructed. Earlier predictions of thermal performance were compared with test data acquired for a bare vacuum tube receiver; and receiver tubes with Alzak aluminum, aluminized FEP Teflon film laminated sheet metal and second surface ordinary mirror reflectors. Test results and system economics as well as objectives of an ongoing program to obtain long-term performance data are discussed.

Selcuk, M. K.↗

Evidence for beaming of Jupiter's decametric radiation - Simultaneous observations from Voyagers and ground-based observatories

Incontrovertible evidence is presented for the beaming of the Jovian decametric radiation, based on simultaneous observations at about 22 MHz from one or both of the Voyager spacecraft and one or the other of two ground-based observatories. The data are used to test the hollow-cone beaming models that have been proposed to account both for the long term statistics of the ground-based observations and for the arc structures discovered in the dynamic spectral plots of Voyager data. It is concluded that occurrences of non-Io-related Source A events are determined by the corotation with the inner Jovian magnetosphere of curved-sheet beams, and those of Io-related Source B storms by a similar type of beam that moves with the northern foot of the Io flux tube. Both types of beam can be approximated by hollow-cone beam sectors.

Maeda, Koitiro↗

Validation test of advanced technology for IPV nickel-hydrogen flight cells - Update

Individual pressure vessel (IPV) nickel-hydrogen technology was advanced at NASA Lewis and under Lewis contracts with the intention of improving cycle life and performance. One advancement was to use 26 percent potassium hydroxide (KOH) electrolyte to improve cycle life. Another advancement was to modify the state-of-the-art cell design to eliminate identified failure modes. The modified design is referred to as the advanced design. A breakthrough in the LEO cycle life of IPV nickel-hydrogen cells has been previously reported. The cycle life of boiler plate cells containing 26 percent KOH electrolyte was about 40,000 LEO cycles compared to 3,500 cycles for cells containing 31 percent KOH. The boiler plate test results are in the process of being validated using flight hardware and real time LEO testing. The primary function of the advanced cell is to store and deliver energy for long-term, LEO spacecraft missions. The new features of this design are: (1) use of 26 percent rather than 31 percent KOH electrolyte; (2) use of a patented catalyzed wall wick; (3) use of serrated-edge separators to facilitate gaseous oxygen and hydrogen flow within the cell, while still maintaining physical contact with the wall wick for electrolyte management; and (4) use of a floating rather than a fixed stack (state-of-the-art) to accommodate nickel electrode expansion due to charge/discharge cycling. The significant improvements resulting from these innovations are: extended cycle life; enhanced thermal, electrolyte, and oxygen management; and accommodation of nickel electrode expansion.

Smithrick, John J.↗

Effect of Bearing Cleaning on Long Term Bearing Life

For many years chlorofluorocarbon (CFC) based solvents, such as CFC-113 and 1,1,1, trichloroethane (TCA), were used as bearing cleaning solvents for space mechanism bearings. The 1995 ban on the production of ozone depleting chemicals (ODC) such as CFCs caused a change requiring the use of ODC-free cleaners for precision bearing cleaning. With this change the question arises; what effect if any do these new cleaners have on long term bearing life? The purpose of this study was to evaluate this effect. A one year test using 60 small electrical motors (two bearings per motor) was conducted in a high vacuum environment (2.0 x 10(exp -6) torr) at a temperature of 90 C. Prior to testing the bearings were cleaned with one of four cleaners. These cleaners included two aqueous based cleaners, a CFC based cleaner and supercritical carbon dioxide. Three space compatible greases were tested. After testing, the mass of each lubricated bearing was measured both pre and post test. Along with mass loss measurements a profilometer trace of each bearing was taken to measure post test wear of the bearings. In addition, the bearings were visually examined and analyzed using an optical microscope.

Jett, Tim↗

Effect of Bearing Cleaning on Long Term Bearing Life

For many years chlorofluorocarbon (CFC ) based solvents, such as Freon and 1,1,1, Trichloroethane (TCA), were used as bearing cleaning solvents for space mechanisms. The 1995 ban on the production of ozone depleting chemicals (ODC) such as CFCs caused a change to new ODC-free cleaners for the precision bearing cleaning. With this change the question arises what effect if any do these new cleaners have on long term bearing life. The purpose of this study was to evaluate this effect. A one year test using 60 small electrical motors (two bearings per motor) was conducted in a high vacuum environment (2.0* 10(exp -6) torr) at a temperature of 90C. Prior to testing the bearings were cleaned with one of four cleaners. These cleaners included two aqueous based cleaners, a CFC based cleaner and supercritical carbon dioxide. Three space compatible greases were tested. After testing the mass of each lubricated bearing was measured both pre and post test. Along with mass loss measurements a profilometer trace of each bearing was taken to measure post test wear of the bearings. In addition the bearings were visually examined and analyzed using an optical microscope.

Jett, Timothy Raymond↗