Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laboratory evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Water Sorption/Desorption Characteristics of Eutectic LiCl-KCl Salt-Occluded Zeolites

Molten salt consisting primarily of eutectic LiCl-KCl is currently being used in electrorefiners in the Fuel Conditioning Facility at Idaho National Laboratory. Options are currently being evaluated for storing this salt outside of the argon atmosphere hot cell. The hygroscopic nature of eutectic LiCl-KCl makes is susceptible to deliquescence in air followed by extreme corrosion of metallic cannisters. In this study, the effect of occluding the salt into a zeolite on water sorption/desorption was tested. Two zeolites were investigated: Na-Y and zeolite 4A. Na-Y was ineffective at occluding a high percentage of the salt at either 10 or 20wt% loading. Zeolite-4A was effective at occluding the salt with high efficiency at both loading levels. Weight gain in salt occluded zeolite-4A (SOZ) from water sorption at 20% relative humidity and 40°C was 17wt% for 10% SOZ and 10wt% for 20% SOZ. In both cases, neither deliquescence nor corrosion occurred over a period of 31 days. After hydration, most of the water could be driven off by heating the hydrated salt occluded zeolite to 530°C. However, some HCl forms during dehydration due to salt hydrolysis. Over a wide range of temperatures (320–700°C) and ramp rates (5, 10, and 20°C min -1 ), HCl formation was no more than 0.6% of the Cl - in the original salt.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A study of selected radiation and propagation problems related to antennas and probes in magneto-ionic media

Research consisted of computations toward the solution of the problem of the current distribution on a cylindrical antenna in a magnetoplasma. The case of an antenna parallel to the applied magnetic field was investigated. A systematic method of asymptotic expansion was found which simplifies the solution in the general case by giving the field of a dipole even at relatively short range. Some useful properties of the dispersion surfaces in a lossy medium have also been found. A laboratory experiment was directed toward evaluating nonlinear effects, such as those due to power level, bias voltage and electron heating. The problem of reflection and transmission of waves in an electron heated plasma was treated theoretically. The profile inversion problem has been pursued. Some results are very encouraging, however, the general question of stability of the solution remains unsolved.

Source record↗

Optical module for the integrated real-time contamination monitor

The concept of a real time contamination monitor is studied and the evolution of the optical module component from laboratory model through the engineering evaluation model is reported. Mechanisms employed and problems experienced are described. Current efforts are directed toward a major simplification of design in a unit intended for flight.

Wrench, E. H.↗

A Simulation Model of the Planetary Boundary Layer at Kennedy Space Center

A simulation model which predicts the behavior of the Atmospheric Boundary Layer has been developed and coded. The model is partially evaluated by comparing it with laboratory measurements and the sounding measurements at Kennedy Space Center. The applicability of such an approach should prove quite widespread.

Hwang, B.↗

Transverse vorticity measurements

A technique, involving programmed digital calculations, is proposed for evaluating transverse vorticity in typical laboratory shear flows from an array of four hot-wire probes. The computing scheme successfully recovers the velocity vector information from a wide range of velocity magnitudes and a wide range of pitch angles. It is readily implemented in a batch process mode on a digital computer.

Foss, J. F.↗

Electrostatic protection of the solar power satellite and rectenna. Part 2: Lightning protection of the rectenna

Computer simulations and laboratory tests were used to evaluate the hazard posed by lightning flashes to ground on the Solar Power Satellite rectenna and to make recommendations on a lightning protection system for the rectenna. The distribution of lightning over the lower 48 of the continental United States was determined, as were the interactions of lightning with the rectenna and the modes in which those interactions could damage the rectenna. Lightning protection was both required and feasible. Several systems of lightning protection were considered and evaluated. These included two systems that employed lightning rods of different lengths and placed on top of the rectenna's billboards and a third, distribution companies; it consists of short lightning rods all along the length of each billboard that are connected by a horizontal wire above the billboard. The distributed lightning protection system afforded greater protection than the other systems considered and was easier to integrate into the rectenna's structural design.

Source record↗

Voice control of the space shuttle video system

A pilot voice control system developed at the Jet Propulsion Laboratory (JPL) to test and evaluate the feasibility of controlling the shuttle TV cameras and monitors by voice commands utilizes a commercially available discrete word speech recognizer which can be trained to the individual utterances of each operator. Successful ground tests were conducted using a simulated full-scale space shuttle manipulator. The test configuration involved the berthing, maneuvering and deploying a simulated science payload in the shuttle bay. The handling task typically required 15 to 20 minutes and 60 to 80 commands to 4 TV cameras and 2 TV monitors. The best test runs show 96 to 100 percent voice recognition accuracy.

Bejczy, A. K.↗

The v = 0 - 0 spectrum of H2

Ground-state rotational parameters for molecular hydrogen are evaluated using a combination of laboratory and observational data. High-accuracy v = 0 - 0 S(0)-S(5) frequencies from infrared laboratory measurements are analyzed simultaneously with available observed frequencies for the S(8), S(9), S(12), S(13), S(14), and S(15) Orion emission lines. The laboratory and Orion measurements are consistent with each other within their measurement errors. The combined data set yields a determination of five v = 0 rotational parameters and an improvement in the high-J calculated line positions. The analysis produces the parameters (in per cm): B(0) = 59.334627(30), D(0) = 0.0456912(30), H(0) = 4.8974(90) x 10 to the -5th, L(0) = -6.320(110) x 10 to the -8th, M(0) = 7.19(30) x 10 to the -11th, where a correction is made for the estimated contribution of sixth and higher orders.

Jennings, D. E.↗

Integrated multi-sensory control of space robot hand

Dexterous manipulation of a robot hand requires the use of multiple sensors integrated into the mechanical hand under distributed microcomputer control. Where space applications such as construction, assembly, servicing and repair tasks are desired of smart robot arms and robot hands, several critical drives influence the design, engineering and integration of such an electromechanical hand. This paper describes a smart robot hand developed at the Jet Propulsion Laboratory for experimental use and evaluation with the Protoflight Manipulator Arm (PFMA) at the Marshall Space Flight Center (MSFC).

Bejczy, A. K.↗

Effects of vibrational enhancement of N2 on the cooling rate of ionospheric thermal electrons

It is shown that the cooling rate of ionospheric thermal electrons by molecular nitrogen may be reduced by more than a factor of 3 as a result of the enhanced vibrational excitation of N2 from a number of chemical sources. Furthermore, under conditions of enhanced F region electron densities (greater than 10 to the 6 per cubic centimeter), N2 may act as a small net source rather than as a sink of electron thermal energy. The object of the study is to use results of the Atmospheric Explorer program and improved laboratory reaction rate measurements to evaluate the impact of N2 vibrational on the transfer of energy between N2 and thermal electrons.

Richards, P. G.↗

Thermal components for 1.8 K space cryogenics

Work of the summer 1986 is summarized in three areas. First, conceptual design of a laboratory system for heat exchanger evaluation in conjunction with the operation of a thermally activated fountain effect pump (FEP) is presented. Second, Knudsen effect evaluation of fine porous media useful for the pressurization plug which forms the main component of the FEP is described. Third, proof-of-principle test of the lab system selected on the basis of the evaluation is summarized.

Chen, W. E. W.↗

Ultrasonic frequency selection for aqueous fine cleaning

A study was conducted to evaluate ultrasonic cleaning systems for precision cleaning effectiveness for oxygen service hardware. This evaluation was specific for Rocketdyne Division of Rockwell Aerospace alloys and machining soils. Machining lubricants and hydraulic fluid were applied as soils to standardized complex test specimens designed to simulate typical hardware. The study consisted of tests which included 20, 25, 30, 40, 50, and 65 kHz ultrasonic cleaning systems. Two size categories of cleaning systems were evaluated, 3- to 10-gal laboratory size tanks and 35- to 320-gal industrial size tanks. The system properties of cavitation, frequency vs. cleaning effectiveness, the two types of transducers, and the power level of the system vs. size of the cleaning tank were investigated. The data obtained from this study was used to select the ultrasonic tanks for the aqueous fine clean facility installed at Rocketdyne.

Becker, Joann F.↗

Performance of residual carrier array-feed combining in correlated noise

An array feed combining system for the recovery of signal-to-noise ratio (SNR) loss due to antenna reflector deformation has been implemented and is currently being evaluated on the Jet Propulsion Laboratory's 34-meter DSS-13 antenna. In this system, the defocused signal field captured by a focal plane array feed is recovered using real-time signal-processing and signal-combining techniques. The current signal-processing and signal-combining algorithms are optimum under the assumption that the white Gaussian noise processes in the received signals from different array elements are mutually uncorrelated. Experimental data at DSS 13 indicate that these noise processes are indeed mutually correlated. The main result of this article is an analytical derivation of the actual SNR performance of the current suboptimal signal-combining algorithm in this correlated-noise environment. The analysis here shows that the combined signal SNR can either be improved or degraded depending on the relation between the array signal and noise correlation coefficient phases. Further performance improvement will require the development of signal-combining methods that take into account the correlated noises.

Tan, H. H.↗

Development of a fiber optic compressor blade sensor

A complete working prototype of the fiber optic blade tip sensor was first tested in the laboratory, followed by a thorough evaluation at NASA W8 Single Compressor Stage Facility in Lewis Research Center. Subsequently, a complete system with three parallel channels was fabricated and delivered to Dr. Kurkov. The final system was tested in the Subsonic Wind Tunnel Facility, in parallel with The General Electric Company's light probe system. The results at all operating speeds were comparable. This report provides a brief description of the system and presents a summary of the experimental results.

Dhadwal, Harbans Singh↗

Ultrasonic frequency selection for aqueous fine cleaning

A study was conducted to evaluate ultrasonic cleaning systems for precision cleaning effectiveness for oxygen service hardware. This evaluation was specific for Rocketdyne Div. of Rockwell Aerospace alloys and machining soils. Machining lubricants and hydraulic fluid were applied as soils to standardized complex test specimens designed to simulate typical hardware. The study consisted of tests which included 20, 25, 30, 40, 50, and 65 kHz ultrasonic cleaning systems. Two size categories of cleaning systems were evaluated, 3- to 10-gal laboratory size tanks and 35- to 320-gal industrial size tanks. The system properties of cavitation; frequency vs. cleaning effectiveness; the two types of transducers; and the power level of the system vs. size of the cleaning tank were investigated. The data obtained from this study was used to select the ultrasonic tanks for the aqueous fine clean facility installed at Rocketdyne.

Becker, Joann F.↗

Optimum combining of residual carrier array signals in correlated noises

An array feed combining system for the recovery of signal-to-noise ratio (SNR) loss due to antenna reflector deformation has been implemented and is currently being evaluated on the Jet Propulsion Laboratory 34-m DSS-13 antenna. The current signal-combining system operates under the assumption that the white Gaussian noise processes in the received signals from different array elements are mutually uncorrelated. However, experimental data at DSS 13 indicate that these noise processes are indeed mutually correlated. The objective of this work is to develop a signal-combining system optimized to account for the mutual correlations between these noise processes. The set of optimum combining weight coefficients that maximizes the combined signal SNR in the correlated noises environment is determined. These optimum weights depend on unknown signal and noise covariance parameters. A maximum-likelihood approach is developed to estimate these unknown parameters to obtain estimates of the optimum weight coefficients based on residual carrier signal samples. The actual combined signal SNR using the estimated weight coefficients is derived and shown to converge to the maximum achievable SNR as the number of signal samples increases. These results are also verified by simulation. A numerical example shows a significant improvement in SNR performance can be obtained, especially when the amount of correlation increases.

Liang, R.↗

Enhanced Raman Monitor Project

Monitoring of gaseous contaminants stems from the need to ensure a healthy and safe environment. NASA/Ames needs sensors that are able to monitor common atmospheric gas concentrations as well as trace amounts of contaminant gases. To provide an accurate assessment of air quality, a monitoring system would need to be continuous and on-line with full spectrum capabilities, allowing simultaneous detection of all gas components in a sample, including both combustible and non-combustible gases. The system demands a high degree of sensitivity to detect low gas concentrations in the low-ppm and sub-ppm regions. For clean and healthy air ('good' category), criteria established by the EPA requires that contaminant concentrations not exceed 4 ppm of carbon monoxide (CO) in an 8 hour period, 60 ppb of ozone(O3) in a one hour period and 30 ppb of sulfur dioxide (SO2) in a 24 hour period. One step below this is the National Ambient Air Quality Standard ('moderate' category) which requires that contaminant concentrations not exceed 9 ppm of carbon monoxide (CO), 120 ppb of ozone (O3) and 140 ppb of sulfur dioxide (SO2) for their respective time periods. Ideally a monitor should be able to detect the concentrations specified in the 'good' category. To benchmark current abilities of Raman technology in gas phase analysis, laboratory experiments were performed to evaluate the RASCAL II anesthetic gas monitor.

Westenskow, Dwayne↗