Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “intervals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Quantifying the statistical complexity of low-frequency fluctuations in semiconductor lasers with optical feedback

Low-frequency fluctuations (LFFs) represent a dynamical instability that occurs in semiconductor lasers when they are operated near the lasing threshold and subject to moderate optical feedback. LFFs consist of sudden power dropouts followed by gradual, stepwise recoveries. We analyze experimental time series of intensity dropouts and quantify the complexity of the underlying dynamics employing two tools from information theory, namely, Shannon's entropy and the Martin, Plastino, and Rosso statistical complexity measure. These measures are computed using a method based on ordinal patterns, by which the relative length and ordering of consecutive interdropout intervals (i.e., the time intervals between consecutive intensity dropouts) are analyzed, disregarding the precise timing of the dropouts and the absolute durations of the interdropout intervals. We show that this methodology is suitable for quantifying subtle characteristics of the LFFs, and in particular the transition to fully developed chaos that takes place when the laser's pump current is increased. Our method shows that the statistical complexity of the laser does not increase continuously with the pump current, but levels off before reaching the coherence collapse regime. This behavior coincides with that of the first- and second-order correlations of the interdropout intervals, suggesting that these correlations, and not the chaotic behavior, are what determine the level of complexity of the laser's dynamics. These results hold for two different dynamical regimes, namely, sustained LFFs and coexistence between LFFs and steady-state emission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precise measurement of hyperfine structure in the 2P{sub 1/2} state of {sup 7}Li using saturated-absorption spectroscopy

We report a precise measurement of the hyperfine interval in the 2P{sub 1/2} state of {sup 7}Li. The transition from the ground state (D{sub 1} line) is accessed using a diode laser and the technique of saturated-absorption spectroscopy in hot Li vapor. The interval is measured by locking an acousto-optic modulator to the frequency difference between the two hyperfine peaks. The measured interval of 92.040(6) MHz is consistent with an earlier measurement reported by us using an atomic-beam spectrometer [Das and Natarajan, J. Phys. B 41, 035001 (2008)]. The interval yields the magnetic dipole constant in the P{sub 1/2} state as A=46.047(3), which is discrepant from theoretical calculations by >80 kHz.

74 ATOMIC AND MOLECULAR PHYSICS↗

Systematic study of projection biases in the weak lensing analysis of cosmic shear and the combination of galaxy clustering and galaxy-galaxy lensing

This paper presents the results of a systematic study of projection biases in the weak lensing analysis of cosmic shear and the combination of galaxy clustering and galaxy-galaxy lensing using data collected during the first year of running the Dark Energy Survey experiment. The study uses Lambda cold dark matter ( Λ CDM ) as the cosmological model and two-point correlation functions for the weak lensing (WL) analysis. The results in this paper show that, independent of the WL analysis, projection biases of more than 1 σ exist and are a function of the position of the true values of the parameters h , n s , Ω b , and Ω ν h 2 with respect to their prior probabilities. For cosmic shear, and the combination of galaxy clustering and galaxy-galaxy lensing, this study shows that the coverage probability of the 68.27% credible intervals ranges from as high as 93% to as low as 16% and that these credible intervals are inflated, on average, by 29% for cosmic shear and 20% for the combination of galaxy clustering and galaxy-galaxy lensing. The results of the study also show that, in six out of nine tested cases, the reduction in error bars obtained by transforming credible intervals into confidence intervals is equivalent to an increase in the amount of data by a factor of 3.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the CP-violating phase β s J/ψΦ in B s 0 →J/ψΦ decays with the CDF II detector

We present a measurement of the CP-violating parameter β s J/ψΦ using approximately 6500 B 0 s →J/ψΦ decays reconstructed with the CDF II detector in a sample of pp̄ collisions at √s=1.96 TeV corresponding to 5.2 fb⁻¹ integrated luminosity produced by the Tevatron collider at Fermilab. We find the CP-violating phase to be within the range β s J/ψΦ ϵ [0.02,0.52]∪[1.08,1.55] at 68% confidence level where the coverage property of the quoted interval is guaranteed using a frequentist statistical analysis. This result is in agreement with the standard model expectation at the level of about one Gaussian standard deviation. We consider the inclusion of a potential S-wave contribution to the B 0 s →J/ψK⁺K⁻ final state which is found to be negligible over the mass interval 1.009 s J/ψΦ , we find the B 0 s decay width difference to be ΔΓ s =0.075±0.035(stat)±0.006(syst) ps⁻¹. We also present the most precise measurements of the B 0 s mean lifetime τ (B 0 s )=1.529±0.025(stat)±0.012(syst) ps, the polarization fractions |A0(0)|²=0.524±0.013(stat)±0.015(syst) and |A II (0)|²=0.231±0.014(stat)±0.015(syst), as well as the strong phase δ ⊥ =2.95±0.64(stat)±0.07(syst) rad. In addition, we report an alternative Bayesian analysis that gives results consistent with the frequentist approach.

Aaltonen, T.↗

Dark matter effective field theory scattering in direct detection experiments

We examine the consequences of the effective field theory (EFT) of dark matter–nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter parameters is discussed. We demonstrate that spectral differences between the standard dark matter model and a general EFT interaction can produce a bias when calculating exclusion limits and when developing signal models for likelihood and machine learning techniques. We also discuss the implications of the EFT for the next-generation (G2) direct detection experiments and point out regions of complementarity in the EFT parameter space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sample variance in weak lensing: How many simulations are required?

Constraining cosmology using weak gravitational lensing consists of comparing a measured feature vector of dimension N b with its simulated counterpart. An accurate estimate of the N b × N b feature covariance matrix C is essential to obtain accurate parameter confidence intervals. When C is measured from a set of simulations, an important question is how large this set should be. To answer this question, we construct different ensembles of N r realizations of the shear field, using a common randomization procedure that recycles the outputs from a smaller number N s ≤ N r of independent ray-tracing N-body simulations. We study parameter confidence intervals as a function of (N s , N r ) in the range 1 ≤ N s ≤ 200 and 1 ≤ N r ≲ 105. Previous work [S. Dodelson and M. D. Schneider, Phys. Rev. D 88, 063537 (2013)] has shown that Gaussian noise in the feature vectors (from which the covariance is estimated) lead, at quadratic order, to an O(1/N r ) degradation of the parameter confidence intervals. Using a variety of lensing features measured in our simulations, including shear-shear power spectra and peak counts, we show that cubic and quartic covariance fluctuations lead to additional O(1/N 2 r ) error degradation that is not negligible when N r is only a factor of few larger than N b . We study the large N r limit, and find that a single, 240 Mpc/h sized 512 3 -particle N-body simulation (N s = 1) can be repeatedly recycled to produce as many as N r = few × 10 4 shear maps whose power spectra and high-significance peak counts can be treated as statistically independent. Lastly, a small number of simulations (N s = 1 or 2) is sufficient to forecast parameter confidence intervals at percent accuracy.

79 ASTRONOMY AND ASTROPHYSICS↗

Midrapidity Antiproton-to-Proton Ratio in pp Collisons at {radical}(s)=0.9 and 7 TeV Measured by the ALICE Experiment

The ratio of the yields of antiprotons to protons in pp collisions has been measured by the ALICE experiment at {radical}(s)=0.9 and 7 TeV during the initial running periods of the Large Hadron Collider. The measurement covers the transverse momentum interval 0.45<p{sub t}<1.05 GeV/c and rapidity |y|<0.5. The ratio is measured to be R{sub |y|<0.5}=0.957{+-}0.006(stat){+-}0.014(syst) at 0.9 TeV and R{sub |y|<0.5}=0.991{+-}0.005(stat){+-}0.014(syst) at 7 TeV and it is independent of both rapidity and transverse momentum. The results are consistent with the conventional model of baryon-number transport and set stringent limits on any additional contributions to baryon-number transfer over very large rapidity intervals in pp collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Scalable Method for Extracting Soiling Rates from PV Production Data

We present a method for analyzing time series production data from photovoltaic systems to extract the rate at which energy yield is affected by the accumulation of dust, dirt, and other forms of soiling. We describe an approach that is based on prevailing methods which consider the change in energy production during dry periods. The method described here builds upon these methods by considering a statistical sample of soiling intervals from each site under consideration. The method enables straightforward application to a large number of sites with minimal parameterization of data-filtering requirements. Furthermore, it enables statistical confidence intervals and comparisons between sites.

14 SOLAR ENERGY↗

Residual analysis of the water resonance signal in breast lesions imaged with high spectral and spatial resolution (HiSS) MRI: A pilot study

Purpose: High spectral and spatial resolution magnetic resonance imaging (HiSS MRI) yields information on the local environment of suspicious lesions. Previous work has demonstrated the advantages of HiSS (complete fat-suppression, improved image contrast, no required contrast agent, etc.), leading to initial investigations of water resonance lineshape for the purpose of breast lesion classification. The purpose of this study is to investigate a quantitative imaging biomarker, which characterizes non-Lorentzian components of the water resonance in HiSS MRI datasets, for computer-aided diagnosis (CADx). Methods: The inhomogeneous broadening and non-Lorentzian or “off-peak” components seen in the water resonance of proton spectra of breast HiSS images are analyzed by subtracting a Lorentzian fit from the water peak spectra and evaluating the difference spectrum or “residual.” The maxima of these residuals (referred to hereafter as “off-peak components”) tend to be larger in magnitude in malignant lesions, indicating increased broadening in malignant lesions. The authors considered only those voxels with the highest magnitude off-peak components in each lesion, with the number of selected voxels dependent on lesion size. Our voxel-based method compared the magnitudes and frequencies of off-peak components of all voxels from all lesions in a database that included 15 malignant and 8 benign lesions (yielding ∼3900 voxels) based on the lesions’ biopsy-confirmed diagnosis. Lesion classification was accomplished by comparing the average off-peak component magnitudes and frequencies in malignant and benign lesions. The area under the ROC curve (AUC) was used as a figure of merit for both the voxel-based and lesion-based methods. Results: In the voxel-based task of distinguishing voxels from malignant and benign lesions, off-peak magnitude yielded an AUC of 0.88 (95% confidence interval [0.84, 0.91]). In the lesion-based task of distinguishing malignant and benign lesions, average off-peak magnitude yielded an AUC 0.83 (95% confidence interval [0.61, 0.98]). Conclusions: These promising AUC values suggest that analysis of the water-resonance in each HiSS image voxel using “residual analysis” could have high diagnostic utility and could be used to enhance current CADx methods and allow detection of breast cancer without the need to inject contrast agents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Online adaptation and verification of VMAT

Purpose: This work presents a method for fast volumetric modulated arc therapy (VMAT) adaptation in response to interfraction anatomical variations. Additionally, plan parameters extracted from the adapted plans are used to verify the quality of these plans. The methods were tested as a prostate class solution and compared to replanning and to their current clinical practice. Methods: The proposed VMAT adaptation is an extension of their previous intensity modulated radiotherapy (IMRT) adaptation. It follows a direct (forward) planning approach: the multileaf collimator (MLC) apertures are corrected in the beam’s eye view (BEV) and the monitor units (MUs) are corrected using point dose calculations. All MLC and MU corrections are driven by the positions of four fiducial points only, without need for a full contour set. Quality assurance (QA) of the adapted plans is performed using plan parameters that can be calculated online and that have a relation to the delivered dose or the plan quality. Five potential parameters are studied for this purpose: the number of MU, the equivalent field size (EqFS), the modulation complexity score (MCS), and the components of the MCS: the aperture area variability (AAV) and the leaf sequence variability (LSV). The full adaptation and its separate steps were evaluated in simulation experiments involving a prostate phantom subjected to various interfraction transformations. The efficacy of the current VMAT adaptation was scored by target mean dose (CTV{sub mean}), conformity (CI{sub 95%}), tumor control probability (TCP), and normal tissue complication probability (NTCP). The impact of the adaptation on the plan parameters (QA) was assessed by comparison with prediction intervals (PI) derived from a statistical model of the typical variation of these parameters in a population of VMAT prostate plans (n = 63). These prediction intervals are the adaptation equivalent of the tolerance tables for couch shifts in the current clinical practice. Results: The proposed adaptation of a two-arc VMAT plan resulted in the intended CTV{sub mean} (Δ ≤ 3%) and TCP (ΔTCP ≤ 0.001). Moreover, the method assures the intended CI{sub 95%} (Δ ≤ 11%) resulting in lowered rectal NTCP for all cases. Compared to replanning, their adaptation is faster (13 s vs 10 min) and more intuitive. Compared to the current clinical practice, it has a better protection of the healthy tissue. Compared to IMRT, VMAT is more robust to anatomical variations, but it is also less sensitive to the different correction steps. The observed variations of the plan parameters in their database included a linear dependence on the date of treatment planning and on the target radius. The MCS is not retained as QA metric due to a contrasting behavior of its components (LSV and AAV). If three out of four plan parameters (MU, EqFS, AAV, and LSV) need to lie inside a 50% prediction interval (3/4—50%PI), all adapted plans will be accepted. In contrast, all replanned plans do not meet this loose criterion, mainly because they have no connection to the initially optimized and verified plan. Conclusions: A direct (forward) VMAT adaptation performs equally well as (inverse) replanning but is faster and can be extended to real-time adaptation. The prediction intervals for the machine parameters are equivalent to the tolerance tables for couch shifts in the current clinical practice. A 3/4—50%PI QA criterion accepts all the adapted plans but rejects all the replanned plans.

60 APPLIED LIFE SCIENCES↗

A Limited-Memory Multiple Shooting Method for Weakly Constrained Variational Data Assimilation

Maximum-likelihood-based state estimation for dynamical systems with model error raises computational challenges in memory usage due to the much larger number of free variables when compared to the perfect model case. To address this challenge, we present a limited-memory method for maximum-likelihood-based estimation of state space models. We reduce the memory storage requirements by expressing the optimal states as a function of checkpoints bounding a shooting interval. All states can then be recomputed as needed from a recursion stemming from the optimality conditions. The matching of states at checkpoints is imposed, in a multiple shooting fashion, as constraints on the optimization problem, which is solved with an augmented Lagrangian method. We prove that for nonlinear systems under certain assumptions the condition number of the Hessian matrix of the augmented Lagrangian function is bounded above with respect to the number of shooting intervals. Hence the method is stable for increasing time horizon. The assumptions include satisfying the observability conditions of the linearized system on a shooting interval. We also propose a recursion-based gradient evaluation algorithm for computing the gradient, which in turn allows the algorithm to proceed by storing at any time only the checkpoints and the states on a shooting interval. We demonstrate our findings with simulations in different regimes for Burgers' equation.

Xu, Wanting↗

Measurements of jet vetoes and azimuthal decorrelations in dijet events produced in pp collisions at √s = 7 TeV using the ATLAS detector

In addition jet activity in dijet events is measured using pp collisions at ATLAS at a centre-of-mass energy of 7TeV, for jets reconstructed using the anti-k t algorithm with radius parameter R=0.6. This is done using variables such as the fraction of dijet events without an additional jet in the rapidity interval bounded by the dijet subsystem and correlations between the azimuthal angles of the dijet s. They are presented, both with and without a veto on additional jet activity in the rapidity interval, as a function of the scalar average of the transverse momenta of the dijet s and of the rapidity interval size. The double differential dijet cross section is also measured as a function of the interval size and the azimuthal angle between the dijet s. These variables probe differences in the approach to resummation of large logarithms when performing QCD calculations. The data are compared to POWERHEG , interfaced to the PYTHIA 8 and HERWIG parton shower generators, as well as to HEJ with and without interfacing it to the ARIADNE parton shower generator. None of the theoretical predictions agree with the data across the full phase-space considered; however, POWERHEG + PYTHIA 8 and HEJ + ARIADNE are found to provide the best agreement with the data. These measurements use the full data sample collected with the ATLAS detector in 7TeV pp collisions at the LHC and correspond to integrated luminosities of 36.1pb –1 and 4.5fb –1 for data collected during 2010 and 2011, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data for "Genetics of flooding tolerance in an F2 Miscanthus sacchariflorus ssp. lutarioriparius × M. sinensis population"

This dataset contains all data and supplementary materials from "Genetics of flooding tolerance in an F2 Miscanthus sacchariflorus ssp. lutarioriparius × M. sinensis population". 1. The dataset S1 table contains the raw phenotypic data collected during the experiment. 2. The dataset S2 table contains the LSmean values for the 24 traits studied. 3. The dataset S3 table contains the TASSEL GBSv2 map, marker information, and genotype data used for mapping. 4. The dataset S4 table contains information on candidate genes found in each of the QTL intervals. 5. The dataset S5 table contains the GO annotations and KEGG enrichment analyses for those candidate genes. 6. The dataset S6 table contains information on the sequences used to classify AP2 ERF transcription factors. 7. The dataset S7 table contains information on AP2 ERF orthologs between Miscanthus and rice based on synteny. 8. Supplementary file 1 contains the ANOVA results using the raw phenotypic data collected from protocol "A". 9. Supplementary file 2 contains the ANOVA results using the raw phenotypic data collected from protocol "B". 10. Supplementary file 3 contains notes on the comparison of SNP calling methods. 11. Supplementary file 4 is a script for analyzing candidate genes found in QTL intervals.

Miscanthus, flood, partial submergence, complete s↗

Automated Algorithm for J-Tpeak and Tpeak-Tend Assessment of Drug-Induced Proarrhythmia Risk

Prolongation of the heart rate corrected QT (QTc) interval is a sensitive marker of torsade de pointes risk; however it is not specific as QTc prolonging drugs that block inward currents are often not associated with torsade. Recent work demonstrated that separate analysis of the heart rate corrected J-T peak c (J-T peak c) and T peak -T end intervals can identify QTc prolonging drugs with inward current block and is being proposed as a part of a new cardiac safety paradigm for new drugs (the “CiPA” initiative). In this work, we describe an automated measurement methodology for assessment of the J-T peak c and T peak -T end intervals using the vector magnitude lead. The automated measurement methodology was developed using data from one clinical trial and was evaluated using independent data from a second clinical trial. Comparison between the automated and the prior semi-automated measurements shows that the automated algorithm reproduces the semi-automated measurements with a mean difference of single-deltas <1 ms and no difference in intra-time point variability (p for all > 0.39). In addition, the time-profile of the baseline and placebo-adjusted changes are within 1 ms for 63% of the time-points (86% within 2 ms). Importantly, the automated results lead to the same conclusions about the electrophysiological mechanisms of the studied drugs. We have developed an automated algorithm for assessment of J-T peak c and T peak -T end intervals that can be applied in clinical drug trials. Under the CiPA initiative this ECG assessment would determine if there are unexpected ion channel effects in humans compared to preclinical studies. In conclusion, the algorithm is being released as open-source software.

60 APPLIED LIFE SCIENCES↗

University of Illinois Campus Deep Direct-Use Feasibility Study - Bedrock Geology ArcGIS Layers

Bedrock Geology of Champaign County, Illinois, map layers (shapefiles). Layers included: 1) Champaign County bedrock units. 2) Champaign County bedrock surface contours. Contour interval of 25 feet. 3) Colchester coal surface contours. Contour interval of 50 feet. 4) Kimmswick Limestone top contours, in the Mahomet dome area. Contour interval of 20 feet. 5) New Albany shale base contour. Contour interval of 100 feet.

15 GEOTHERMAL ENERGY↗

Boat-Dragged Riverbed and Mid-Column Water Quality along the Hanford Reach in the Columbia River Shorelines

This dataset contains water quality measurements used to identify sites of hydrologic exchange (i.e.hydrologic exchange flows; HEFs) in the Columbia River near Richland, WA by looking for anomalies in temperature and electrical conductivity (EC) along the bed of the river in February, June, July, August, and November 2017. These are ultimately the ‘ends’ of HEFs as they are locations of subsurface inflow to the river. This dataset contains dissolved oxygen (DO) measurements at 1-min intervals; temperature, EC, depth, and GPS coordinates at 1-second intervals; and N-NO3 at 2-min intervals along the river bed and mid-column water. DO measurements are included in this dataset for completeness but were not used in the analysis of HEFs due to the relatively long time interval of collection.

54 ENVIRONMENTAL SCIENCES↗

Measurements of jet vetoes and azimuthal decorrelations in dijet events produced in p p collisions at s = 7 TeV using the ATLAS detector

CERN-LHC. Additional jet activity in dijet events is measured using pp collisions at ATLAS at a centre-of-mass energy of 7 TeV, for jets reconstructed using the anti-kt algorithm with radius parameter R=0.6. This is done using variables such as the fraction of dijet events without an additional jet in the rapidity interval bounded by the dijet subsystem and correlations between the azimuthal angles of the dijets. They are presented, both with and without a veto on additional jet activity in the rapidity interval, as a function of the mean transverse momentum of the dijets and of the rapidity interval size. The double differential dijet cross section is also measured as a function of the interval size and the azimuthal angle between the dijets. These variables probe differences in the approach to resummation of large logarithms when performing QCD calculations. The data are compared to POWHEG, interfaced to the PYTHIA 8 and HERWIG parton shower generators, as well as to HEJ with and without interfacing it to the ARIADNE parton shower generator. None of the theoretical predictions agree with the data across the full phase-space considered; however, POWHEG+PYTHIA 8 and HEJ+ARIADNE are found to provide the best agreement with the data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗