Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

New primordial-magnetic-field limit from the latest LIGO S5 data

Since the energy momentum tensor of a magnetic field always contains a spin-2 component in its anisotropic stress, stochastic primordial magnetic field (PMF) in the early universe must generate stochastic gravitational-wave (GW) background. This process will greatly affect the relic gravitational wave (RGW), which is one of the major scientific goals of the laser interferometer GW detections. Recently, the fifth science (S5) run of laser interferometer gravitational-wave observatory (LIGO) gave a latest upper limit {Omega}{sub GW}<6.9x10{sup -6} on the RGW background. Utilizing this upper limit, we derive new PMF limits: for a scale of galactic cluster {lambda}=1 Mpc, the amplitude of PMF, that produced by the electroweak phase transition, has to be weaker than B{sub {lambda}{<=}4}x10{sup -7} G; for a scale of supercluster {lambda}=100 Mpc, the amplitude of PMF has to be weaker than B{sub {lambda}{<=}9}x10{sup -11} G. In this manner, GW observation has potential to make interesting contributions to the study of primordial magnetic field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Opto-acoustic interactions in gravitational wave detectors: Comparing flat-top beams with Gaussian beams

To reduce the thermal noise in the future generation of gravitational wave detectors, flat-top beams have been proposed to replace conventional Gaussian beams, so as to obtain better averaging over the Brownian motion of the test masses. Here, we present a detailed investigation of the unwanted opto-acoustic interactions in such interferometers, which can lead to the phenomenon of parametric instability. Our results show that the increased overlap of the Mesa beams with the test masses leads to approximately 3 times as many unstable modes in comparison to a similar interferometer with Gaussian beams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for gravitational waves from compact binary coalescence in LIGO and Virgo data from S5 and VSR1

We report the results of the first search for gravitational waves from compact binary coalescence using data from the Laser Interferometer Gravitational-Wave Observatory and Virgo detectors. Five months of data were collected during the Laser Interferometer Gravitational-Wave Observatory's S5 and Virgo's VSR1 science runs. The search focused on signals from binary mergers with a total mass between 2 and 35M{sub {center_dot}}. No gravitational waves are identified. The cumulative 90%-confidence upper limits on the rate of compact binary coalescence are calculated for nonspinning binary neutron stars, black hole-neutron star systems, and binary black holes to be 8.7x10{sup -3} yr{sup -1} L{sub 10}{sup -1}, 2.2x10{sup -3} yr{sup -1} L{sub 10}{sup -1}, and 4.4x10{sup -4} yr{sup -1} L{sub 10}{sup -1}, respectively, where L{sub 10} is 10{sup 10} times the blue solar luminosity. These upper limits are compared with astrophysical expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Saturation amplitude of the f-mode instability

We investigate strong nonlinear damping effects which occur during high amplitude oscillations of neutron stars, and the gravitational waves they produce. For this, we use a general relativistic nonlinear hydrodynamics code in conjunction with a fixed spacetime (Cowling approximation) and a polytropic equation of state (EOS). Gravitational waves are estimated using the quadrupole formula. Our main interest are l=m=2 f modes subject to the CFS (Chandrasekhar, Friedman, Schutz) instability, but we also investigate axisymmetric and quasiradial modes. We study various models to determine the influence of rotation rate and EOS. We find that axisymmetric oscillations at high amplitudes are predominantly damped by shock formation, while the nonaxisymmetric f modes are mainly damped by wave breaking and, for rapidly rotating models, coupling to nonaxisymmetric inertial modes. From the observed nonlinear damping, we derive upper limits for the saturation amplitude of CFS-unstable f modes. Finally, we estimate that the corresponding gravitational waves for an oscillation amplitude at the upper limit should be detectable with the advanced LIGO (Laser Interferometer Gravitational Wave Observatory) and VIRGO interferometers at distances above 10 Mpc. This strongly depends on the stellar model, in particular, on the mode frequency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detector configuration of DECIGO/BBO and identification of cosmological neutron-star binaries

The primary target for the planned space-borne gravitational wave interferometers DECIGO/BBO (Decihertz Interferometer Gravitational Wave Observatory/Big Bang Observer) is a primordial gravitational wave background. However there exist astrophysical foregrounds, and among them, gravitational waves from neutron-star (NS) binaries are the solid and strong component that must be identified and subtracted. In this paper, we discuss the geometry of detector configurations preferable for identifying the NS/NS binary signals. As a first step, we analytically estimate the minimum signal-to-noise ratios of the binaries for several static detector configurations that are characterized by adjustable geometrical parameters, and determine the optimal values for these parameters. Next we perform numerical simulations to take into account the effect of detector motions, and find reasonable agreements with the analytical results. We show that, with the standard network formed by 4 units of triangle detectors, the proposed BBO sensitivity would be sufficient in receiving gravitational waves from all the NS/NS binaries at z{<=}5 with signal-to-noise ratios higher than 25. We also discuss the minimum sensitivity of DECIGO required for the foreground identification.

79 ASTRONOMY AND ASTROPHYSICS↗

Extreme mass-ratio inspirals in the effective-one-body approach: Quasicircular, equatorial orbits around a spinning black hole

We construct effective-one-body waveform models suitable for data analysis with the Laser Interferometer Space Antenna for extreme mass-ratio inspirals in quasicircular, equatorial orbits about a spinning supermassive black hole. The accuracy of our model is established through comparisons against frequency-domain, Teukolsky-based waveforms in the radiative approximation. The calibration of eight high-order post-Newtonian parameters in the energy flux suffices to obtain a phase and fractional amplitude agreement of better than 1 rad and 1%, respectively, over a period between 2 and 6 months depending on the system considered. This agreement translates into matches higher than 97% over a period between 4 and 9 months, depending on the system. Better agreements can be obtained if a larger number of calibration parameters are included. Higher-order mass-ratio terms in the effective-one-body Hamiltonian and radiation reaction introduce phase corrections of at most 30 rad in a 1 yr evolution. These corrections are usually 1 order of magnitude larger than those introduced by the spin of the small object in a 1 yr evolution. These results suggest that the effective-one-body approach for extreme mass-ratio inspirals is a good compromise between accuracy and computational price for Laser Interferometer Space Antenna data-analysis purposes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetar asteroseismology with long-term gravitational waves

Magnetic flares and induced oscillations of magnetars (supermagnetized neutron stars) are promising sources of gravitational waves (GWs). We suggest that the GW emission, if any, would last longer than the observed x-ray quasiperiodic oscillations (X-QPOs), calling for longer-term GW analyses lasting a day to months, compared to current searches' durations. Like the pulsar timing, the oscillation frequency would also evolve with time because of the decay or reconfiguration of the magnetic field, which is crucial for the GW detection. With the observed GW frequency and its time-derivatives, we can probe the interior magnetic field strength of {approx}10{sup 16} G and its evolution to open a new GW asteroseismology with the next generation interferometers like the advanced laser interferometer gravitational wave observatory, the advanced Virgo gravitational wave detector at the European Gravitational Observatory, the Large-scale cryogenic gravitational wave telescope, and the Einstein telescope.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gravitational Waves from Fragmentation of a Primordial Scalar Condensate into Q Balls

A generic consequence of supersymmetry is the formation of a scalar condensate along the flat directions of the potential at the end of cosmological inflation. This condensate is usually unstable, and it can fragment into nontopological solitons, Q balls. The gravitational waves produced by the fragmentation can be detected by the Laser Interferometer Space Antenna, Advanced Laser Interferometer Gravitational-Wave Observatory, and Big Bang Observer, which can open an important window to the early Universe and the physics at some very high energy scales.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of Two-Source Interference in the Photoproduction Reaction AuAu{yields}AuAu{rho}{sup 0}

In ultraperipheral relativistic heavy-ion collisions, a photon from the electromagnetic field of one nucleus can fluctuate to a quark-antiquark pair and scatter from the other nucleus, emerging as a {rho}{sup 0}. The {rho}{sup 0} production occurs in two well-separated (median impact parameters of 20 and 40 F for the cases considered here) nuclei, so the system forms a two-source interferometer. At low transverse momenta, the two amplitudes interfere destructively, suppressing {rho}{sup 0} production. Since the {rho}{sup 0} decays before the production amplitudes from the two sources can overlap, the two-pion system can only be described with an entangled nonlocal wave function, and is thus an example of the Einstein-Podolsky-Rosen paradox. We observe this suppression in 200 GeV per nucleon-pair gold-gold collisions. The interference is 87%{+-}5%(stat.){+-}8%(syst.) of the expected level. This translates into a limit on decoherence due to wave function collapse or other factors of 23% at the 90% confidence level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Large Momentum Beam Splitter Using Bloch Oscillations

The sensitivity of an inertial sensor based on an atomic interferometer is proportional to the velocity separation of atoms in the two arms of the interferometer. In this Letter we describe how Bloch oscillations can be used to increase this separation and to create a large momentum transfer (LMT) beam splitter. We experimentally demonstrate a separation of 10 recoil velocities. Light shifts during the acceleration introduce phase fluctuations which can reduce the fringes contrast. We precisely calculate this effect and demonstrate that it can be significantly reduced by using a suitable combination of LMT pulses. We finally show that this method seems to be very promising to realize a LMT beam splitter with several tens of recoils and a very good efficiency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absolute Geodetic Rotation Measurement Using Atom Interferometry

We demonstrate a cold-atom interferometer gyroscope which overcomes accuracy and dynamic range limitations of previous atom interferometer gyroscopes. We show how the instrument can be used for precise determination of latitude, azimuth (true north), and Earth's rotation rate. Spurious noise terms related to multiple-path interferences are suppressed by employing a novel time-skewed pulse sequence. Extended versions of this instrument appear capable of meeting the stringent requirements for inertial navigation, geodetic applications of Earth's rotation rate determination, and tests of general relativity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Realization of Decoherence-Free Subspace in Neutron Interferometry

A decoherence-free subspace (DFS) is an important class of quantum-error-correcting (QEC) codes that have been proposed for fault-tolerant quantum computation. The applications of QEC techniques, however, are not limited to quantum-information processing (QIP). Here we demonstrate how QEC codes may be used to improve experimental designs of quantum devices to achieve noise suppression. In particular, neutron interferometry is used as a test bed to show the potential for adding quantum error correction to quantum measurements. We built a five-blade neutron interferometer that incorporates both a standard Mach-Zender configuration and a configuration based on a DFS. Experiments verify that the DFS interferometer is protected against low-frequency mechanical vibrations. We anticipate these improvements will increase the range of applications for matter-wave interferometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optics and interferometry with atoms and molecules

Interference with atomic and molecular matter waves is a rich branch of atomic physics and quantum optics. It started with atom diffraction from crystal surfaces and the separated oscillatory fields technique used in atomic clocks. Atom interferometry is now reaching maturity as a powerful art with many applications in modern science. In this review the basic tools for coherent atom optics are described including diffraction by nanostructures and laser light, three-grating interferometers, and double wells on atom chips. Scientific advances in a broad range of fields that have resulted from the application of atom interferometers are reviewed. These are grouped in three categories: (i) fundamental quantum science, (ii) precision metrology, and (iii) atomic and molecular physics. Although some experiments with Bose-Einstein condensates are included, the focus of the review is on linear matter wave optics, i.e., phenomena where each single atom interferes with itself.

74 ATOMIC AND MOLECULAR PHYSICS↗

Micro-fluidics and integrated optics glass sensor for in-line micro-probing of nuclear samples

We study the miniaturisation of Thermal Lens Spectrometry (TLS) towards Lab-on-chip integration in order to reduce the volume of fluid assays in nuclear process control. TLS is of great interest in this context since it combines the advantages of optical detection methods with an inherent suitability for small-scale samples. After validating the experimental principle in a classical thermal lens crossed-beam setup, we show the integration of a Young-interferometer with a microcapillary on a glass substrate, reducing the necessary sample size to 400 nl. The interferometer translates the photo-thermally induced refractive index change in the fluid to a phase shift of the fringe pattern, which can then be detected by a camera. Measurements of Co(II) in ethanol yield a detection limit of c = 5 x 10{sup -4} M for the crossed-beam setup and c = 6x10{sup -3} M for the integrated sensor. At an interaction length of 10 {mu}m, it detects a minimum absorbance of AU = 6 x 10{sup -5} in a probed volume of 10 pl. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micro-fluidics and integrated optics glass sensor for in-line micro-probing of nuclear samples

We study the miniaturization of Thermal Lens Spectrometry (TLS) towards Lab-on-chip integration in order to reduce the volume of fluid assays in nuclear process control. TLS is of great interest in this context since it combines the advantages of optical detection methods with an inherent suitability for small-scale samples. After validating the experimental principle in a classical thermal lens crossed-beam setup, we show the integration of a Young-interferometer with a microcapillary on a glass substrate, reducing the necessary sample size to 400 nl. The interferometer translates the photo-thermally induced refractive index change in the fluid to a phase shift of the fringe pattern, which can then be detected by a camera. Measurements of Co(II) in ethanol yield a detection limit of c = 5 x 10{sup -4} M for the crossed-beam setup and c = 6 x 10{sup -3} M for the integrated sensor. At an interaction length of 10 m, it detects a minimum absorbance of K = 1.2 x 10{sup -4} in a probed volume of 14 pl. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-resolution broadband spectroscopy using externally dispersed interferometry at the Hale telescope: Part 2, photon noise theory

High-resolution broadband spectroscopy at near-infrared (NIR) wavelengths (950 to 2450 nm) has been performed using externally dispersed interferometry (EDI) at the Hale telescope at Mt. Palomar, with the TEDI interferometer mounted within the central hole of the 200-in. primary mirror in series with the comounted TripleSpec NIR echelle spectrograph. These are the first multidelay EDI demonstrations on starlight. We demonstrated very high (10×) resolution boost and dramatic (20× or more) robustness to point spread function wavelength drifts in the native spectrograph. Data analysis, results, and instrument noise are described in a companion paper (part 1). This part 2 describes theoretical photon limited and readout noise limited behaviors, using simulated spectra and instrument model with noise added at the detector. We show that a single interferometer delay can be used to reduce the high frequency noise at the original resolution (1× boost case), and that except for delays much smaller than the native response peak half width, the fringing and nonfringing noises act uncorrelated and add in quadrature. This is due to the frequency shifting of the noise due to the heterodyning effect. We find a sum rule for the noise variance for multiple delays. The multiple delay EDI using a Gaussian distribution of exposure times has noise-to-signal ratio for photon-limited noise similar to a classical spectrograph with reduced slitwidth and reduced flux, proportional to the square root of resolution boost achieved, but without the focal spot limitation and pixel spacing Nyquist limitations. At low boost (~1×) EDI has ~1.4× smaller noise than conventional, and at >10× boost, EDI has ~1.4× larger noise than conventional. Readout noise is minimized by the use of three or four steps instead of 10 of TEDI. Net noise grows as step phases change from symmetrical arrangement with wavenumber across the band. As a result, for three (or four) steps, we calculate a multiplicative bandwidth of 1.8:1 (2.3:1), sufficient to handle the visible band (400 to 700 nm, 1.8:1) and most of TripleSpec (2.6:1).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MO-AB-BRA-03: Calorimetry-Based Absorbed Dose to Water Measurements Using Interferometry

Purpose: Interferometry-based calorimetry is a novel technique to measure radiation-induced temperature changes allowing the measurement of absorbed dose to water (ADW). There are no mechanical components in the field. This technique also has the possibility of obtaining 2D dose distributions. The goal of this investigation is to calorimetrically-measure doses between 2.5 and 5 Gy over a single projection in a photon beam using interferometry and compare the results with doses calculated using the TG-51 linac calibration. Methods: ADW was determined by measuring radiation-induced phase shifts (PSs) of light passing through water irradiated with a 6 MV photon beam. A 9×9×9 cm{sup 3} glass phantom filled with water and placed in an arm of a Michelson interferometer was irradiated with 300, 400, 500 and 600 monitor units. The whole system was thermally insulated to achieve sufficient passive temperature control. The depth of measurement was 4.5 cm with a field size of 7×7 cm{sup 2}. The intensity of the fringe pattern was monitored with a photodiode and used to calculate the time-dependent PS curve. Data was acquired 60 s before and after the irradiation. The radiation-induced PS was calculated by taking the difference in the pre- and post-irradiation drifts extrapolated to the midpoint of the irradiation. Results were compared to computed doses. Results: Average comparison of calculated ADW values with interferometry-measured values showed an agreement to within 9.5%. k=1 uncertainties were 4.3% for calculations and 14.7% for measurements. The dominant source of uncertainty for the measurements was a temperature drift of about 30 µK/s caused by heat conduction from the interferometer’s surroundings. Conclusion: This work presented the first absolute ADW measurements using interferometry in the dose range of linac-based radiotherapy. Future work to improve measurements’ reproducibility includes the implementation of active thermal control techniques.

60 APPLIED LIFE SCIENCES↗

Spherical grating based x-ray Talbot interferometry

Purpose: Grating interferometry is a state-of-the-art x-ray imaging approach, which can acquire information on x-ray attenuation, phase shift, and small-angle scattering simultaneously. Phase-contrast imaging and dark-field imaging are very sensitive to microstructural variation and offers superior contrast resolution for biological soft tissues. However, a common x-ray tube is a point-like source. As a result, the popular planar grating imaging configuration seriously restricts the flux of photons and decreases the visibility of signals, yielding a limited field of view. The purpose of this study is to extend the planar x-ray grating imaging theory and methods to a spherical grating scheme for a wider range of preclinical and clinical applications. Methods: A spherical grating matches the wave front of a point x-ray source very well, allowing the perpendicular incidence of x-rays on the grating to achieve a higher visibility over a larger field of view than the planer grating counterpart. A theoretical analysis of the Talbot effect for spherical grating imaging is proposed to establish a basic foundation for x-ray spherical gratings interferometry. An efficient method of spherical grating imaging is also presented to extract attenuation, differential phase, and dark-field images in the x-ray spherical grating interferometer. Results: Talbot self-imaging with spherical gratings is analyzed based on the Rayleigh–Sommerfeld diffraction formula, featuring a periodic angular distribution in a polar coordinate system. The Talbot distance is derived to reveal the Talbot self-imaging pattern. Numerical simulation results show the self-imaging phenomenon of a spherical grating interferometer, which is in agreement with the theoretical prediction. Conclusions: X-ray Talbot interferometry with spherical gratings has a significant practical promise. Relative to planar grating imaging, spherical grating based x-ray Talbot interferometry has a larger field of view and improves both signal visibility and dose utilization for pre-clinical and clinical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗