Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Neutron Radiography Reactor Reactivity -- Focused Lessons Learned

As part of the Global Threat Reduction Initiative, the Neutron Radiography Reactor (NRAD) at the Idaho National Laboratory (INL) was converted from using highly enriched uranium (HEU) to low enriched uranium (LEU) fuel. After the conversion, NRAD resumed operations and is meeting operational requirements. Radiography image quality and the number of images that can be produced in a given time frame match pre-conversion capabilities. However, following the conversion, NRAD’s excess reactivity with the LEU fuel was less than it had been with the HEU fuel. Although some differences between model predictions and actual performance are to be expected, the lack of flexibility in NRAD’s safety documentation prevented adjusting the reactivity by adding more fuel, until the safety documentation could be modified. To aid future reactor conversions, a reactivity-focused Lessons Learned meeting was held. This report summarizes the findings of the lessons learned meeting and addresses specific questions posed by DOE regarding NRAD’s conversion and reactivity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

UIT support observations archive

We are in the process of archiving the approximately 1.2Tbytes of imaging data acquired in support of UIT observations. The UIT is one of three telescopes comprising the ASTRO spacecraft and is a 38-cm f/9 Ritchey-Chretien telescope with wavelength coverage 1200 A to 3000 A and a 40 arcminute diameter field-of-view at 4 min FWHM resolution. During the ASTRO shuttle mission, there were 65 different pointings (some with multiple targets) of the UIT and hence 65 fields. Our support data of these fields were obtained with the KPNO and CTIO 0.9m telescopes and several of the 2048x2048 CCD's. Our images are typically about 20 acrminutes on a side and contain the entire UV target except for nearby galaxies, for which mosaiced images were created. All good quality images in the broadband and narrow band filters for every target are being archived. Though all of the UIT targets were well studied astronomical objects, these frames are many of the first large field format images of them and, when combined with the soon to be released UV frames, provide a unique dataset. These data were already used to address a wide variety of astronomical questions. Vacuum ultraviolet (VUV) observations were used to study star formation in a sample of nearby galaxies, since integrated VUV - optical colors provide the most sensitive available measure of the formation rate of massive stars. The blue stages later in stellar evolution are also being studied. These data allow more accurate determination of the helium and metallicities of hothorzontal branch stars. These data are being prepared to release to the public in CD-ROM format through the National Space Science Data Center.

Smith, Eric P.↗

Rotary Wing Flight Test Methods Used for the Evaluation of Night Vision Devices

A number of rotary wing flight tests have been conducted by the Army Aeroflightdynamics Directorate in cooperation with NASA which involved the use of night vision devices and simulated devices. The test set up and data analysis have been taken from two perspectives. Some of the flight tests were structured to look at aircraft handling qualities when the pilot's image quality was reduced from normal daylight levels. In this case, aircraft flight path information was given to the pilot as one input into the Handling Qualities Ratings. Other flight tests were structured to look at pilot and workload directly. In this second case, aircraft position was accurately measured and used as pilot performance data. This paper provides an overview of the test methods used, lessons learned, and recommendations for future tam of night vision devices.

Haworth, Loran↗

Broadband Phase Retrieval for Image-Based Wavefront Sensing

A focus-diverse phase-retrieval algorithm has been shown to perform adequately for the purpose of image-based wavefront sensing when (1) broadband light (typically spanning the visible spectrum) is used in forming the images by use of an optical system under test and (2) the assumption of monochromaticity is applied to the broadband image data. Heretofore, it had been assumed that in order to obtain adequate performance, it is necessary to use narrowband or monochromatic light. Some background information, including definitions of terms and a brief description of pertinent aspects of image-based phase retrieval, is prerequisite to a meaningful summary of the present development. Phase retrieval is a general term used in optics to denote estimation of optical imperfections or aberrations of an optical system under test. The term image-based wavefront sensing refers to a general class of algorithms that recover optical phase information, and phase-retrieval algorithms constitute a subset of this class. In phase retrieval, one utilizes the measured response of the optical system under test to produce a phase estimate. The optical response of the system is defined as the image of a point-source object, which could be a star or a laboratory point source. The phase-retrieval problem is characterized as image-based in the sense that a charge-coupled-device camera, preferably of scientific imaging quality, is used to collect image data where the optical system would normally form an image. In a variant of phase retrieval, denoted phase-diverse phase retrieval [which can include focus-diverse phase retrieval (in which various defocus planes are used)], an additional known aberration (or an equivalent diversity function) is superimposed as an aid in estimating unknown aberrations by use of an image-based wavefront-sensing algorithm. Image-based phase-retrieval differs from such other wavefront-sensing methods, such as interferometry, shearing interferometry, curvature wavefront sensing, and Shack-Hartmann sensing, all of which entail disadvantages in comparison with image-based methods. The main disadvantages of these non-image based methods are complexity of test equipment and the need for a wavefront reference.

Dean, Bruce H.↗

Mask roughness induced LER control and mitigation: aberrations sensitivity study and alternate illumination scheme

Here we conduct a mask-roughness-induced line-edge-roughness (LER) aberrations sensitivity study both as a random distribution amongst the first 16 Fringe Zernikes (for overall aberration levels of 0.25, 0.50, and 0.75nm rms) as well as an individual aberrations sensitivity matrix over the first 37 Fringe Zernikes. Full 2D aerial image modeling for an imaging system with NA = 0.32 was done for both the 22-nm and 16-nm half-pitch nodes on a rough mask with a replicated surface roughness (RSR) of 100 pm and a correlation length of 32 nm at the nominal extreme-ultraviolet lithography (EUVL) wavelength of 13.5nm. As the ideal RSR value for commercialization of EUVL is 50 pm and under, and furthermore as has been shown elsewhere, a correlation length of 32 nm of roughness on the mask sits on the peak LER value for an NA = 0.32 imaging optic, these mask roughness values and consequently the aberration sensitivity study presented here, represent a worst-case scenario. The illumination conditions were chosen based on the possible candidates for the 22-nm and 16-nm half-pitch nodes, respectively. In the 22-nm case, a disk illumination setting of {sigma} = 0.50 was used, and for the 16-nm case, crosspole illumination with {sigma} = 0.10 at an optimum offset of dx = 0 and dy = .67 in sigma space. In examining how to mitigate mask roughness induced LER, we considered an alternate illumination scheme whereby a traditional dipole's angular spectrum is extended in the direction parallel to the line-and-space mask absorber pattern to represent a 'strip'. While this illumination surprisingly provides minimal improvement to the LER as compared to several alternate illumination schemes, the overall imaging quality in terms of image-log-slope (ILS) and contrast is improved.

36 MATERIALS SCIENCE↗

Vessel network detection using contour evolution and color components

Automated retinal screening relies on vasculature segmentation before the identification of other anatomical structures of the retina. Vasculature extraction can also be input to image quality ranking, neovascularization detection and image registration, among other applications. There is an extensive literature related to this problem, often excluding the inherent heterogeneity of ophthalmic clinical images. The contribution of this paper relies on an algorithm using front propagation to segment the vessel network. The algorithm includes a penalty in the wait queue on the fast marching heap to minimize leakage of the evolving interface. The method requires no manual labeling, a minimum number of parameters and it is capable of segmenting color ocular fundus images in real scenarios, where multi-ethnicity and brightness variations are parts of the problem.

59 BASIC BIOLOGICAL SCIENCES↗

System and method for controlling depth of imaging in tissues using fluorescence microscopy under ultraviolet excitation following staining with fluorescing agents

The present disclosure relates to a method for analyzing tissue specimens. In one implementation the method involves obtaining a tissue sample and exposing the sample to one or more fluorophores as contrast agents to enhance contrast of subcellular compartments of the tissue sample. The tissue sample is illuminated by an ultraviolet (UV) light having a wavelength between about 200 nm to about 400 nm, with the wavelength being selected to result in penetration to only a specified depth below a surface of the tissue sample. Inter-image operations between images acquired under different imaging parameters allow for improvement of the image quality via removal of unwanted image components. A microscope may be used to image the tissue sample and provide the image to an image acquisition system that makes use of a camera. The image acquisition system may create a corresponding image that is transmitted to a display system for processing and display.

36 MATERIALS SCIENCE↗

SU-E-I-26: The CT Compatibility of a Novel Direction Modulated Brachytherapy (DMBT) Tandem Applicator for Cervical Cancer

Purpose: To examine CT metal image artifact from a novel direction-modulated brachytherapy (DMBT) tandem applicator (95% tungsten) for cervical cancer using a commercially available orthopedic metal artifact reduction (O-MAR) algorithm. Comparison to a conventional stainless steel applicator is also performed. Methods: Each applicator was placed in a water-filled phantom resembling the female pelvis and scanned in a Philips Brilliance 16-slice CT scanner using two pelvis protocols: a typical clinical protocol (120kVp, 16×0.75mm collimation, 0.692 pitch, 1.0s rotation, 350mm field of view (FOV), 600mAs, 1.5mm slices) and a protocol with a higher kVp and mAs setting useful for larger patients (140kVp, 16×0.75mm collimation, 0.688 pitch, 1.5s rotation, 350mm FOV, 870mAs, 1.5mm slices). Images of each tandem were acquired with and without the application of the O-MAR algorithm. Baseline scans of the phantom (no applicator) were also collected. CT numbers were quantified at distances from 5 to 30 mm away from the applicator’s edge (in increments of 5mm) using measurements at eight angles around the applicator, on three consecutive slices. Results: While the presence of both applicators degraded image quality, the DMBT applicator resulted in larger streaking artifacts and dark areas in the image compared to the stainless steel applicator. Application of the O-MAR algorithm improved all acquired images, both visually and quantitatively. The use of low and high kVp and mAs settings (120 kVp/600mAs and 140 kVp/870mAs) in conjunction with the O-MAR algorithm lead to similar CT numbers in the vicinity of the applicator and a similar reduction of the induced metal artifact. Conclusion: This work indicated that metal artifacts induced by the DMBT and the stainless steel applicator are greatly reduced when using the O-MAR algorithm, leading to better quality phantom images. The use of a high dose protocol provided similar improvements in metal artifacts compared to the clinical protocol.

60 APPLIED LIFE SCIENCES↗

Quality metrics for sensor images

Methods are needed for evaluating the quality of augmented visual displays (AVID). Computational quality metrics will help summarize, interpolate, and extrapolate the results of human performance tests with displays. The FLM Vision group at NASA Ames has been developing computational models of visual processing and using them to develop computational metrics for similar problems. For example, display modeling systems use metrics for comparing proposed displays, halftoning optimizing methods use metrics to evaluate the difference between the halftone and the original, and image compression methods minimize the predicted visibility of compression artifacts. The visual discrimination models take as input two arbitrary images A and B and compute an estimate of the probability that a human observer will report that A is different from B. If A is an image that one desires to display and B is the actual displayed image, such an estimate can be regarded as an image quality metric reflecting how well B approximates A. There are additional complexities associated with the problem of evaluating the quality of radar and IR enhanced displays for AVID tasks. One important problem is the question of whether intruding obstacles are detectable in such displays. Although the discrimination model can handle detection situations by making B the original image A plus the intrusion, this detection model makes the inappropriate assumption that the observer knows where the intrusion will be. Effects of signal uncertainty need to be added to our models. A pilot needs to make decisions rapidly. The models need to predict not just the probability of a correct decision, but the probability of a correct decision by the time the decision needs to be made. That is, the models need to predict latency as well as accuracy. Luce and Green have generated models for auditory detection latencies. Similar models are needed for visual detection. Most image quality models are designed for static imagery. Watson has been developing a general spatial-temporal vision model to optimize video compression techniques. These models need to be adapted and calibrated for AVID applications.

Ahumada, AL↗

Magnetic Resonance Imaging Protocol Optimization for Delineation of Gross Tumor Volume in Hypopharyngeal and Laryngeal Tumors

Purpose: To optimize the use of MRI for delineation of gross tumor volume for radiotherapy treatment planning purposes in hypopharyngeal and laryngeal tumors. Methods and Materials: Magnetic resonance images (T1 weighted and T2 weighted) of a healthy volunteer were acquired using a 1.5 T and 3.0 T MR scanner. Various receiver coils were investigated that were compatible with the immobilization mask needed for reliable coregistration with computed tomography data. For the optimal receiver coil, the influence of resolution, slice thickness, and strength of magnetic field on the signal-to-noise ratio (SNR) was studied. Feasibility of the definitive protocol was tested on patients with hypopharyngeal (n = 19) and laryngeal (n = 42) carcinoma. Results: Large differences in SNR were obtained for the various coils. The SNR values obtained using surface coils that were compatible with the immobilization mask were three times higher than those obtained using a standard head-and-neck coil and five times higher than those obtained using a body coil. High-resolution images (0.4 x 0.4 x 4 mm{sup 3}) showed superior anatomic detail and resulted in a 4-min scan time. Image quality at 3.0 T was not significantly better compared with 1.5 T. In 3 patients the MR study could not be performed; for 5 patients images were severely deteriorated by motion artefacts. High-quality MR images were obtained in 53 patients. Conclusions: High-resolution MR images of the hypopharynx and larynx can be obtained in the majority of patients using surface receiver coils in combination with the radiotherapy mask. These MR images can be successfully used for tumor delineation in radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging Supersonic Aircraft Shock Waves

A schlieren imaging system that uses the sun as a light source was developed it) obtain direct flow-field images of shock waves of aircraft in flight. This system was used to study how shock waves evolve to form sonic booms. The image quality obtained was limited by several optical and mechanical factors. Converting the photographs to digital images and applying digital image-processing techniques greatly improved the final quality of the images and more clearly showed the shock structures.

Weinstein, Leonard M.↗

Iterative image reconstruction for CBCT using edge-preserving prior

On-board cone-beam computed tomography (CBCT) is a new imaging technique for radiation therapy guidance, which provides volumetric information of a patient at treatment position. CBCT improves the setup accuracy and may be used for dose reconstruction. However, there is great concern that the repeated use of CBCT during a treatment course delivers too much of an extra dose to the patient. To reduce the CBCT dose, one needs to lower the total mAs of the x-ray tube current, which usually leads to reduced image quality. Our goal of this work is to develop an effective method that enables one to achieve a clinically acceptable CBCT image with as low as possible mAs without compromising quality. An iterative image reconstruction algorithm based on a penalized weighted least-squares (PWLS) principle was developed for this purpose. To preserve edges in the reconstructed images, we designed an anisotropic penalty term of a quadratic form. The algorithm was evaluated with a CT quality assurance phantom and an anthropomorphic head phantom. Compared with conventional isotropic penalty, the PWLS image reconstruction algorithm with anisotropic penalty shows better resolution preservation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An assessment of the resolution limitation due to radiation-damage in X-ray diffraction microscopy

X-ray diffraction microscopy (XDM) is a new form of x-ray imaging that is being practiced at several third-generation synchrotron-radiation x-ray facilities. Nine years have elapsed since the technique was first introduced and it has made rapid progress in demonstrating high-resolution three-dimensional imaging and promises few-nm resolution with much larger samples than can be imaged in the transmission electron microscope. Both life- and materials-science applications of XDM are intended, and it is expected that the principal limitation to resolution will be radiation damage for life science and the coherent power of available x-ray sources for material science. In this paper we address the question of the role of radiation damage. Here, we use a statistical analysis based on the so-called "dose fractionation theorem" of Hegerl and Hoppe to calculate the dose needed to make an image of a single life-science sample by XDM with a given resolution. We find that for simply-shaped objects the needed dose scales with the inverse fourth power of the resolution and present experimental evidence to support this finding. To determine the maximum tolerable dose we have assembled a number of data taken from the literature plus some measurements of our own which cover ranges of resolution that are not well covered otherwise. The conclusion of this study is that, based on the natural contrast between protein and water and "Rose-criterion" image quality, one should be able to image a frozen-hydrated biological sample using XDM at a resolution of about 10 nm.

36 MATERIALS SCIENCE↗

Fabrication of high aspect grating using bonded substrate for X-ray refraction imaging by Talbot-Lau interferometer

In order to improve the image quality of X-ray refraction images using a Talbot-Lau interferometer, we have been attempting to fabricate gratings with high aspect ratio. In our attempt, deep grooves of grating structure were channeled on a Si substrate bonded by Au diffusion bonding method, and the grooves were filled with Au where the Au layer used for the bonding Si substrate was acting as a seed layer of Au electroplating. From the results of a visibility measurement and a cross sectional SEM image, it was confirmed that the grooves with a pitch of 5.8 {mu}m and a depth of 100 {mu}m could be successfully filled with Au over a large area of 72 Multiplication-Sign 80 mm{sup 2}. Using this grating, the X-ray refraction images for the cartilage of a knee joint of a livestock pig could be obtained where SPS method was employed for the single-shot image acquisition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Anniversary Paper: History and status of CAD and quantitative image analysis: The role of Medical Physics and AAPM

The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists' goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities that are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists--as opposed to a completely automatic computer interpretation--focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous--from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects--collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more--from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization

Purpose: The authors previously developed the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. The XCAT consisted of highly detailed whole-body models for the standard male and female adult, including the cardiac and respiratory motions. In this work, the authors extend the XCAT beyond these reference anatomies by developing a series of anatomically variable 4D XCAT adult phantoms for imaging research, the first library of 4D computational phantoms. Methods: The initial anatomy of each phantom was based on chest-abdomen-pelvis computed tomography data from normal patients obtained from the Duke University database. The major organs and structures for each phantom were segmented from the corresponding data and defined using nonuniform rational B-spline surfaces. To complete the body, the authors manually added on the head, arms, and legs using the original XCAT adult male and female anatomies. The structures were scaled to best match the age and anatomy of the patient. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from the template XCAT phantom (male or female) to the target patient model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. Each new phantom was refined by checking for anatomical accuracy via inspection of the models. Results: Using these methods, the authors created a series of computerized phantoms with thousands of anatomical structures and modeling cardiac and respiratory motions. The database consists of 58 (35 male and 23 female) anatomically variable phantoms in total. Like the original XCAT, these phantoms can be combined with existing simulation packages to simulate realistic imaging data. Each new phantom contains parameterized models for the anatomy and the cardiac and respiratory motions and can, therefore, serve as a jumping point from which to create an unlimited number of 3D and 4D variations for imaging research. Conclusions: A population of phantoms that includes a range of anatomical variations representative of the public at large is needed to more closely mimic a clinical study or trial. The series of anatomically variable phantoms developed in this work provide a valuable resource for investigating 3D and 4D imaging devices and the effects of anatomy and motion in imaging. Combined with Monte Carlo simulation programs, the phantoms also provide a valuable tool to investigate patient-specific dose and image quality, and optimization for adults undergoing imaging procedures.

60 APPLIED LIFE SCIENCES↗

A novel adaptive discrete cosine transform-domain filter for gap-inpainting of high resolution PET scanners

Purpose: Several positron emission tomography (PET) scanners with special detector block arrangements have been developed in recent years to improve the resolution of PET images. However, the discontinuous detector blocks cause gaps in the sinogram. This study proposes an adaptive discrete cosine transform-based (aDCT) filter for gap-inpainting. Methods: The gap-corrupted sinogram was morphologically closed and subsequently converted to the DCT domain. A certain number of the largest coefficients in the DCT spectrum were identified to determine the low-frequency preservation region. The weighting factors for the remaining coefficients were determined by an exponential weighting function. The aDCT filter was constructed and applied to two digital phantoms and a simulated phantom introduced with various levels of noise. Results: For the Shepp-Logan head phantom, the aDCT filter filled the gaps effectively. For the Jaszczak phantom, no secondary artifacts were induced after aDCT filtering. The percent mean square error and mean structure similarity of the aDCT filter were superior to those of the DCT2 filter at all noise levels. For the simulated striatal dopamine innervation study, the aDCT filter recovered the shape of the striatum and restored the striatum to reference activity ratios to the ideal value. Conclusions: The proposed aDCT filter can recover the missing gap data in the sinogram and improve the image quality and quantitative accuracy of PET images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Applications of the Multi-Beam SEM [Abstract Only]

The Zeiss Multi-Beam Scanning Electron Microscope (MultiSEM) was used to image a wide array samples using non-standard operating conditions. The ability of this new, high-throughput imaging technique to produce high-quality images was assessed during this one year LDRD. In addition to exploring new imaging conditions, sample preparation techniques, coupled with theoretical simulations, were explored to optimize the MultiSEM images. To obtain details about the devices imaged, as well as the experimental details, please refer to the classified report from the project manager, Bradley Gabel, or the Cyber IA lead, Justin Ford.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗