Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Gold Nanoparticle Microwave Synthesis

At the nanometer scale, numerous compounds display different properties than those found in bulk material that can prove useful in areas such as medicinal chemistry. Gold nanoparticles, for example, display promise in newly developed hyperthermia therapies for cancer treatment. Currently, gold nanoparticle synthesis is performed via the hot injection technique which has large variability in final particle size and a longer reaction time. One underdeveloped area by which these particles could be produced is through microwave synthesis. To initiate heating, microwaves agitate polar molecules creating a vibration that gives off the heat energy needed. Previous studies have used microwaves for gold nanoparticle synthesis; however, polar solvents were used that partially absorbed incident microwaves, leading to partial thermal heating of the sample rather than taking full advantage of the microwave to solely heat the gold nanoparticle precursors in a non-polar solution. Through this project, microwaves were utilized as the sole heat source, and non-polar solvents were used to explore the effects of microwave heating only as pertains to the precursor material. Our findings show that the use of non-polar solvents allows for more rapid heating as compared to polar solvents, and a reduction in reaction time from 10 minutes to 1 minute; this maximizes the efficiency of the reaction, and allows for reproducibility in the size/shape of the fabricated nanoparticles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Huntsville Urban Development II: Utilizing NASA Earth Observations to Map the Urban Heat Island and Evaluate Vulnerability in Huntsville, Alabama

Huntsville, Alabama has seen a boom in growth over recent years. One consequence of this urban expansion is the exacerbation of the Urban Heat Island (UHI) effect across the city. This project identified the areas within Huntsville the greatest potential for heat reduction and community health benefits from tree-planting efforts. The team created maps of land surface temperature (LST), the normalized difference vegetation index (NDVI), and the normalized difference built-up index (NDBI) over June through August from 2019 to 2022 using data from ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station, Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS), Landsat 9 OLI-2 and TIRS-2. The team identified areas with high LST, low NDVI, and high NDBI as areas with the greatest potential for heat reduction via tree-planting. Social factors relating to age, race, income, and self-reported health were adapted from Tree Equity Score to map community need for tree cover. When combining social with environmental factors, the team determined areas with the greatest potential for UHI mitigation: west-central and north downtown Huntsville. The team’s partner organization, the City of Huntsville, can use this priority map to guide their future tree-planting, and weigh the factors assessed according to their preference.

James Karroum↗

Heat rejection development requirements for orbital power systems

Long-term orbital applications in which large amounts of electrical power are generated and utilized will require waste heat rejection beyond the capabilities of existing radiator systems. Therefore, it will be necessary to develop a new concept for large orbital energy systems. This paper presents a discussion of the primary factors to be considered in the design and development of a large orbital power module heat rejection system. Specific design requirements are defined based on these factors, and a review of supporting technology in the advanced space radiator area is presented. A proposed development approach and a candidate baseline heat rejection system are then identified and discussed.

Rankin, J. G.↗

Direct heating surface combustor

The combustor utilizes a non-adiabatic flame to provide low-emission combustion for gas turbines. A fuel-air mixture is directed through a porous wall, the other side of which serves as a combustion surface. A radiant heat sink disposed adjacent to and spaced from the combustion surface controls the combustor flame temperature in order to prevent the formation of oxides of nitrogen. A secondary air flow cools the heat sink. Additionally, up to 100% of secondary air flow is mixed with the combustion products at the direct heating surface combustor to dilute such products thereby reducing exit temperature. However, if less than 100% secondary air is mixed to the combustor, the remainder may be added to the combustion products further downstream.

Beremand, D. G.↗

Experimental Investigation of Entrance-region Heat-transfer Coefficients

Experimental results of tests made at the Langley Memorial Aeronautical Laboratory are presented to show how heat-transfer coefficients can he increased by a method utilizing the high rate of heat transfer known to exist on any heat-transfer surface in the region adjacent to the edge on which the cooling or heating fluid impinges. The results show that, for the same pressure drop, the average surface heat-transfer.coefficient can be increased 50 to 100 percent when a cooling surface having a length of four inches in the direction of fluid flow is cut to form twenty fins with a length of 0.2 inch in the direction of fluid flow and the fins are sharpened and staggered in the air stream. The percentage of increase in the surface heat-transfer coefficient obtained as a result of shortening the length of the cooling surface varies with the pressure drop of the cooling fluid in passing the surface, the increase being largest when small pressure drop is used and smallest when high pressure drop is used.

HEAT EXCHANGERS - PRESSURE DROP↗

Replacing Resistance Heating with Mini-Split Heat Pumps: Sharon, Connecticut (Fact Sheet)

Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programs are discussed in detail.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mini-Split Heat Pumps Multifamily Retrofit Feasibility Study

Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programs are discussed in detail.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mini-Split Heat Pumps Multifamily Retrofit Feasibility Study

Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programs are discussed in detail.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Demonstration and Adoption Impacts of an Affordable Thermoelectric Heat Pump

This study presents the design, field validation, and utility impacts of an air source heat pump that uses thermoelectric (TE) technology to provide supplemental heating at outside air temperatures below 17°F. Conventional heat pumps experience reduced heating capacity and COP at low outdoor temperatures due to the temperature difference between the source and demand sides of the vapor compression cycle. Consequently, during colder months, supplemental heating such as electric resistance or natural gas furnace is often needed to provide additional warmth, which increases the overall equipment and energy costs. To address this challenge, a TE subcooler (an array of solid-state, thermoelectric modules that provides heat pumping using non-vapor compression technique) is fabricated and integrated with the vapor compression cycle of a conventional air-source heat pump. In colder ambient conditions, TE subcooler exchanges heat with the refrigerant to provide additional subcooling, thereby enhancing the capacity of the heat pump. The operation of thermoelectric-integrated heat pump was demonstrated in an occupied single-family home in Nashville, TN. The TE subcooler increased the system’s heating capacity at 15°F outdoor temperature by 25–30% and reduced electricity demand by 10%. It also met the heating load in the house without supplemental electric resistance down to 5°F outdoors, delivering the additional heat at nearly 80% greater efficiency compared to electric resistance heating. With a modest first cost increment of 10–15% over conventional single-speed heat pumps, this approach offers a promising, energy-efficient solution to accelerate residential heat pump adoption in the U.S.

KRISHNAMOORTHY, Sreenidhi [Electric Power Research↗

Review of Shape and Topology Optimization for Design of Air-to-Refrigerant Heat Exchangers

Air-to-refrigerant heat exchangers (HXs) have been the topic of exhaustive research as they are fundamental components of HVAC&R systems. It has been well-established that the large airside thermal resistance dominates the HX thermal resistance, and thus significant research efforts have focused on improving the air-side performance of these heat exchangers. As HXs continue to become more compact, thermal resistance reduction is typically realized through the utilization of extended secondary heat transfer surfaces such as fins. However, past research has shown that the thermal-hydraulic trade-offs provided by fins are often not attractive enough to warrant their use, especially for small diameter tubes. Yet, the inadequate primary surface area provided by compact HXs essentially mandate the necessity of fins to meet thermal resistance requirements. In recent years, advancements in computational tools such as Computational Fluid Dynamics (CFD) and optimization algorithms, coupled with the advent of additive manufacturing technologies, have allowed engineers to expand conventional HX design ideologies to include such concepts as shape and topology optimization. This lends itself directly to primary heat transfer surface optimization and even the potential removal of finned surfaces altogether. This paper presents a comprehensive literature review investigating air-to-refrigerant HX shape and topology optimization. The fundamentals of both shape and topology optimization, model development, and experimental validations are all separately discussed. Studies featuring manufactured prototypes and/or experimentally validated optimal designs are treated with additional emphasis. This paper concludes by identifying key research gaps and proposing future research directions for HX shape and topology optimization.

42 ENGINEERING↗

Truck Thermoacoustic Generator and Chiller

This Final Report describes the accomplishments of the US Department of Energy (DOE) cooperative agreement project DE-FC26-04NT42113 - Truck Thermoacoustic Generator and Chiller - whose goal is to design, fabricate and test a thermoacoustic piezoelectric generator and chiller system for use on over-the-road heavy-duty-diesel trucks, driven alternatively by the waste heat of the main diesel engine exhaust or by a burner integrated into the thermoacoustic system. The thermoacoustic system would utilize engine exhaust waste heat to generate electricity and cab air conditioning, and would also function as an auxiliary power unit (APU) for idle reduction. The unit was to be tested in Volvo engine performance and endurance test cells and then integrated onto a Class 8 over-the-road heavy-duty-diesel truck for further testing on the road. The project has been a collaboration of The Pennsylvania State University Applied Research Laboratory, Los Alamos National Laboratory, Clean Power Resources Inc., and Volvo Powertrain (Mack Trucks Inc.). Cost share funding was provided by Applied Research Laboratory, and by Clean Power Resources Inc via its grant from Innovation Works - funding that was derived from the Commonwealth of Pennsylvania. Los Alamos received its funding separately through DOE Field Work Proposal 04EE09.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Energy and Water Recovery Technology from Low Grade Waste Heat

The project has developed a nanoporous membrane based water vapor separation technology that can be used for recovering energy and water from low-temperature industrial waste gas streams with high moisture contents. This kind of exhaust stream is widely present in many industrial processes including the forest products and paper industry, food industry, chemical industry, cement industry, metal industry, and petroleum industry. The technology can recover not only the sensible heat but also high-purity water along with its considerable latent heat. Waste heats from such streams are considered very difficult to recover by conventional technology because of poor heat transfer performance of heat-exchanger type equipment at low temperature and moisture-related corrosion issues. During the one-year Concept Definition stage of the project, the goal was to prove the concept and technology in the laboratory and identify any issues that need to be addressed in future development of this technology. In this project, computational modeling and simulation have been conducted to investigate the performance of a nanoporous material based technology, transport membrane condenser (TMC), for waste heat and water recovery from low grade industrial flue gases. A series of theoretical and computational analyses have provided insight and support in advanced TMC design and experiments. Experimental study revealed condensation and convection through the porous membrane bundle was greatly improved over an impermeable tube bundle, because of the membrane capillary condensation mechanism and the continuous evacuation of the condensate film or droplets through the membrane pores. Convection Nusselt number in flue gas side for the porous membrane tube bundle is 50% to 80% higher than those for the impermeable stainless steel tube bundle. The condensation rates for the porous membrane tube bundle also increase 60% to 80%. Parametric study for the porous membrane tube bundle heat transfer performance was also done, which shows this heat transfer enhancement approach works well in a wide parameters range for typical flue gas conditions. Better understanding of condensing heat transfer mechanism for porous membrane heat transfer surfaces, shows higher condensation and heat transfer rates than non-permeable tubes, due to existence of the porous membrane walls. Laboratory testing has documented increased TMC performance with increased exhaust gas moisture content levels, which has exponentially increased potential markets for the product. The TMC technology can uniquely enhance waste heat recovery in tandem with water vapor recovery for many other industrial processes such as drying, wet and dry scrubber exhaust gases, dewatering, and water chilling. A new metallic substrate membrane tube development and molded TMC part fabrication method, provides an economical way to expand this technology for scaled up applications with less than 3 year payback expectation. A detailed market study shows a broad application area for this advanced waste heat and water recovery technology. A commercialization partner has been lined up to expand this technology to this big market. This research work led to new findings on the TMC working mechanism to improve its performance, better scale up design approaches, and economical part fabrication methods. Field evaluation work needs to be done to verify the TMC real world performance, and get acceptance from the industry, and pave the way for our commercial partner to put it into a much larger waste heat and waste water recovery market. This project is addressing the priority areas specified for DOE Industrial Technologies Program's (ITP's): Energy Intensive Processes (EIP) Portfolio - Waste Heat Minimization and Recovery platform.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Saving Melting and Revert Reduction (E-SMARRT): Optimization of Heat Treatments on Stainless Steel Castings for Improved Corrosion Resistance and Mechanical Properties

It is commonly believed that high alloy steel castings have inferior corrosion resistance to their wrought counterparts as a result of the increased amount of microsegregation remaining in the as-cast structure. Homogenization and dissolution heat treatments are often utilized to reduce or eliminate the residual microsegregation and dissolve the secondary phases. Detailed electron probe microanalysis (EPMA) and light optical microscopy (LOM) were utilized to correlate the amount of homogenization and dissolution present after various thermal treatments with calculated values and with the resultant corrosion resistance of the alloys.The influence of heat treatment time and temperature on the homogenization and dissolution kinetics were investigated using stainless steel alloys CN3MN and CK3MCuN. The influence of heat treatment time and temperature on the impact toughness and corrosion reistance of cast stainless steel alloys CF-3, CF-3M, CF-8, and CF-8M was also investigated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measuring Titanium Heat Pipe Thermal Conductivity for CO2 Adsorption Systems

Current models of the Air-Cooled Temperature Swing Adsorption Compressor (AC-TSAC) being developed for long duration space exploration utilize cooling chambers and heat plates to adsorb and desorb contaminants -13 . To reduce resources required and lower the equivalent system mass (ESM), the study focuses on determining the applications of titanium heat pipe systems to operate both phases, allowing for future research into the development of a heat pipe chamber to hold the zeolite formulations.

multifunctional sorbent↗