Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Gas chromatographic column for the Viking 1975 molecular analysis experiment

A gas chromatographic column has been developed for use in the remote analysis of the Martian surface. The column, which utilizes a liquid-modified organic adsorbent (Tenax) as the stationary phase, provides efficient transmission and resolution of nanogram quantities of organic materials in the presence of millionfold excesses of water and carbon dioxide.

Novotny, M.↗

HD gas purification for polarized HDice targets production at Jefferson Lab

Solid, frozen-spin targets of molecular HD were rst developed for nuclear physics by a collaboration between Syracuse University and Brookhaven National Lab. They have been successfully used in measurements with photon beams, rst at the Laser-Electron-Gamma-Source [1] and most recently at Je erson Lab during the running of the E06-101 (g14) experiment [2]. Preparations are underway to utilize the targets in future electron experiments after the completion of the 12 GeV JLab upgrade [3]. HD is an attractive target since all of the material is polarizable, of low Z, and requires only modest holding elds. At the same time, the small contributions from the target cell can be subtracted from direct measurements. Reaching the frozen-spin state with both high polarization and a signi cant spin relaxation time requires careful control of H2 and D2 impurities. Commercially available HD contains 0.5 - 2% concentrations of H2 and D2. Low-temperature distillation is required to reduce these concentrations to the 104 level to enable useful target production. This distillation is done using a column lled with heli-pack C [4] to give good separation e ciency. Approximately 12 moles of commercial HD is condensed into the mechanically refrigerated system at the base temperature of 11K. The system is then isolated and the temperature stabilized at 18K producing liquid HD, which is boiled by a resistive heater. The circulation established by the boil-o condensing throughout the column then ltering back down produces a steady-state isotopic separation permitting the extraction of HD gas with very low H2 and D2 content. A residual gas analyzer initially monitors distillation. Once the H2 concentration falls below its useful operating range, samples are periodically collected for analysis using gas chromatography [5] and Raman scattering. Where the measurement techniques overlap, good agreement is obtained. The operation of the distillery and results of gas analysis will be discussed. References [1] Phy. Rev. Lett. 101 (2009) 172002. [2] www.jlab.org/exp_prog/proposals/06/PR-06-101.pdf [3] www.jlab.org/exp_prog/proposals/12/PR12-12-009.pdf, www.jlab.org/exp_prog/proposals/12/PR12-12-010.pdf, and www.jlab.org/exp_prog/proposals/11/PR12-11-111.pdf [4] Nucl. Inst. Meth. 664 (2012) 347, www.wilmad-labglass.com/Products/LG-6730-104/ [5] Rev. Sci. Instrum. 82, 024101 (2011).

Whisnant, Charles↗

The Mineralogical and Chemical Case for Habitability at Yellowknife Bay, Gale Crater, Mars

Sediments of the Yellowknife Bay formation (Gale crater) include the Sheepbed member, a mudstone cut by light-toned veins. Two drill samples, John Klein and Cumberland, were collected and analyzed by the CheMin XRD/XRF instrument and the Sample Analysis at Mars (SAM) evolved gas and isotopic analysis suite of instruments. Drill cuttings were also analyzed by the Alpha Particle X-ray Spectrometer (APXS) for bulk composition. The CheMin XRD analysis shows that the mudstone contains basaltic minerals (Fe-forsterite, augite, pigeonite, plagioclase), as well as Fe-oxide/hydroxides, Fe-sulfides, amorphous materials, and trioctahedral phyllosilicates. SAM evolved gas analysis of higher-temperature OH matches the CheMin XRD estimate of ~20% clay minerals in the mudstone. The light-toned veins contain Ca-sulfates; anhydrite and bassanite are detected by XRD but gypsum is also indicated from Mastcam spectral mapping. These sulfates appear to be almost entirely restricted to late-diagenetic veins. The sulfate content of the mudstone matrix itself is lower than other sediments analyzed on Mars. The presence of phyllosilicates indicates that the activity of water was high during their formation and/or transport and deposition (should they have been detrital). Lack of chlorite places limits on the maximum temperature of alteration (likely <100 C). The presence of Ca-sulfates rather than Mg- or Fe-sulfates suggests that the pore water pH was near-neutral and of relatively low ionic strength (although x-ray amorphous Mg-and Fe- sulfates could be present and undetectable by CheMin). The presence of Fe and S in both reduced and oxidized states represents chemical disequilibria that could have been utilized by chemolithoautotrophic biota, if present. When compared to the nearby Rocknest sand shadow mineralogy or the normative mineralogy of Martian soil, both John Klein and Cumberland exhibit a near-absence of olivine and a surplus of magnetite (7-9% of the crystalline component). The magnetite is interpreted as an authigenic product formed when olivine was altered to phyllosilicate. Saponitization of olivine (a process analogous to serpentinization) could have produced H2 in situ. Indeed, early diagenetic hollow nodules ("minibowls") present in the Cumberland mudstone are interpreted by some as forming when gas bubbles accumulated in the unconsolidated mudstone. Lastly, all of these early diagenetic features appear to have been preserved with minimal alteration since their formation, as indicated by the ease of drilling (weak lithification, lack of cementing phases), the presence of 20-30% amorphous material, and the late-stage fracturing with emplacement of calcium sulfate veins and minibowl infills, where they were intersected by veins. A rough estimate of the minimum duration of the lacustrine environment is provided by the minimum thickness of the Sheepbed member. Given 1.5 meters, and applying a mean sediment accumulation rate for lacustrine strata of 1 m/1000 yrs yields a duration of 1,500 years. If the aqueous environments represented by overlying strata are considered, such as Gillespie Lake and Shaler, then this duration increases. The Sheepbed mudstone meets all the requirements of a habitable environment: Aqueous deposition at clement conditions of P, T, pH, Eh and ionic strength, plus the availability of sources of chemical energy.

Blake, David Frederick↗

Techno-economic and life cycle analysis of synthetic natural gas production from low-carbon H 2 and point-source or atmospheric CO 2 in the United States

Synthetic natural gas (SNG) is of great interest in reducing fossil energy consumption while maintaining compatibility with existing NG infrastructure and end-use applications equipment. SNG can be produced using clean H 2 generated from renewable or nuclear energy and CO 2 captured from stationary sources or the atmosphere. In this study, we develop an engineering process model of SNG production using Aspen Plus® and production scales reported by the industry. We examine the levelized cost and life cycle greenhouse gas (GHG) emissions of SNG production under various CO 2 supply scenarios. Considering the higher cost of H 2 transportation compared with CO 2 transportation, we assume that CO 2 feedstock is transported via pipeline to the H 2 production location, which is collocated with the SNG plant. We also evaluate the cost of CO 2 captured from the atmosphere, assuming the direct air capture process can occur near the SNG facility. Depending on the CO 2 supply chain, the levelized cost of SNG is estimated to be in the range of $\$45–76$ per million British thermal units (MMBtu) on a higher heating value (HHV) basis. The SNG production cost may be reduced to $\$27–57$/MMBtu-HHV by applying a tax credit available in the United States for low-carbon H 2 production (45V). With a lower electricity price of 3¢/kWh for water electrolysis and accounting for a 45V tax credit, the SNG cost reaches parity with the cost of fossil NG. Depending on the CO 2 supply chain, SNG can reduce life cycle GHG emissions by 52–88% compared with fossil NG.

03 NATURAL GAS↗

Comparison of two gas chromatograph models and analysis of binary data

The overall objective of the gas chromatograph system studies is to generate fundamental design criteria and techniques to be used in the optimum design of the system. The particular tasks currently being undertaken are the comparison of two mathematical models of the chromatograph and the analysis of binary system data. The predictions of two mathematical models, an equilibrium absorption model and a non-equilibrium absorption model exhibit the same weaknesses in their inability to predict chromatogram spreading for certain systems. The analysis of binary data using the equilibrium absorption model confirms that, for the systems considered, superposition of predicted single component behaviors is a first order representation of actual binary data. Composition effects produce non-idealities which limit the rigorous validity of superposition.

Keba, P. S.↗

Comments on “Failure analysis of corroded hydrogen-blended natural gas pipelines based on finite element analysis and genetic algorithm-back propagation neural network” [262 (2025) 111174]

This is a brief commentary paper to highlight and discuss the determination of hydrogen concentration in pipeline steel, effect of hydrogen embrittlement (HE) on the mechanical properties of the material, burst strength of corroded pipelines using finite element analysis (FEA) simulations, and curve-fit models for assessing remaining strength of X80 corroded pipelines for transporting hydrogen blended natural gas. Recently, Xie et al. [1] proposed a methodology to quantify the impact of HE on material properties and numerically determined burst pressure of X80 corroded pipelines. However, their HE quantification overestimated the degradation of tensile strength for hydrogen blending ratios beyond the original data range, and their FEA results of burst pressure are nonconservative. This work thus recharacterized the hydrogen concentration in the steel pipeline and the effect of HE on tensile strength, and then redetermined burst pressures for a set of typical corrosion defect cases considered by Xie et al. [1] based on an experimentally validated FEA modelling method. With the new FEA results, two empirical corrosion models were proposed for X80 corroded pipelines for hydrogen service. At zero hydrogen blending ratio, the novel empirical models predict burst pressures to be consistent with the industry-accepted corrosion models. Furthermore, both the numerical simulation method and the novel corrosion models are significant contributions to the pipeline industry and the hydrogen community. Application of these results will enhance the safety, reliability, and integrity of natural gas pipelines when used to transport hydrogen.

Burst pressure prediction↗

Sensitivity Analysis of the Fission Gas Behavior Model in BISON

This report summarizes the result of a NEAMS project focused on sensitivity analysis of a new model for the fission gas behavior (release and swelling) in the BISON fuel performance code of Idaho National Laboratory. Using the new model in BISON, the sensitivity of the calculated fission gas release and swelling to the involved parameters and the associated uncertainties is investigated. The study results in a quantitative assessment of the role of intrinsic uncertainties in the analysis of fission gas behavior in nuclear fuel.

Swiler, Laura Painton↗

Subminiaturized gas chromatograph gives fast, efficient analysis

Space oriented, lightweight, subminiaturized gas chromatograph analyzes gas samples in a few seconds with a carrier gas flow of one milliliter per second. In extraterrestrial exploration, the system could be used with a mass spectrometer for detection of life-supporting compounds.

Wilhite, W. F.↗

Stress analysis and life prediction of gas turbine blade

A stress analysis procedure is presented for a redesign of the Space Shuttle Main Engine high pressure fuel turbopump turbine blades. The analysis consists of the one-dimensional scoping analysis to support the design layout and the follow-on three-dimensional finite element analysis to confirm the blade design at operating loading conditions. Blade life is evaluated based on high-cycle fatigue and low-cycle fatigue.

Hsiung, H. C.↗

LSENS, a general chemical kinetics and sensitivity analysis code for gas-phase reactions: User's guide

A general chemical kinetics and sensitivity analysis code for complex, homogeneous, gas-phase reactions is described. The main features of the code, LSENS, are its flexibility, efficiency and convenience in treating many different chemical reaction models. The models include static system, steady, one-dimensional, inviscid flow, shock initiated reaction, and a perfectly stirred reactor. In addition, equilibrium computations can be performed for several assigned states. An implicit numerical integration method, which works efficiently for the extremes of very fast and very slow reaction, is used for solving the 'stiff' differential equation systems that arise in chemical kinetics. For static reactions, sensitivity coefficients of all dependent variables and their temporal derivatives with respect to the initial values of dependent variables and/or the rate coefficient parameters can be computed. This paper presents descriptions of the code and its usage, and includes several illustrative example problems.

Radhakrishnan, Krishnan↗

Air Contamination Quantification by FTIR with Gas Cell

Air quality is of utmost importance in environmental studies and has many industrial applications such as aviators grade breathing oxygen (ABO) for pilots and breathing air for fire fighters. Contamination is a major concern for these industries as identified in MIL-PRF-27210, CGA G-4.3, CGA G-7.1, and NFPA 1989. Fourier Transform Infrared Spectroscopy (FTIR) is a powerful tool that when combined with a gas cell has tremendous potential for gas contamination analysis. Current procedures focus mostly on GC-MS for contamination quantification. Introduction of this topic will be done through a comparison of the currently used deterministic methods for gas contamination with those of FTIR gas analysis. Certification of the mentioned standards through the ISOIEC 17065 certifying body A2LA will be addressed followed by an evaluation of quality information such as the determinations of linearity and the limits of detection and quantitation. Major interferences and issues arising from the use of the FTIR for accredited work with ABO and breathing air will be covered.

Freischlag, Jason↗

Techno-Economic Analysis of Greenfield Geothermal Hybrid Power Plants using a Solar or Natural Gas Steam Topping Cycle

The relatively low generation costs associated with wind, solar photovoltaic (PV), and natural-gas power plants make it challenging for geothermal power plants to produce and sell the power that has the reliability and sustainability characteristics that are greatly needed in U.S. power markets. This is especially true for geothermal resources with low-to-medium temperatures, which results in relatively low-thermal efficiency and generation costs that are higher than those for wind, solar PV, and natural gas. This analysis evaluates solar thermal- and natural-gas combustion waste heat recovery-based topping cycle hybridization of geothermal binary power plants. This approach provides several benefits that may allow geothermal power plants to generate power at more competitive costs. First, the addition of solar thermal energy or natural-gas combustion waste heat input to a geothermal power plant provides additional heat input that can be converted to electrical power. Second, the temperature level of the heat obtained from concentrating solar collectors or natural-gas combustion exhaust is higher than that of geothermal heat, which provides opportunities for improving the efficiency of the conversion of thermal energy to electrical power. Third, the ease with which solar thermal systems integrate with energy storage and the flexibility of natural gas means power generation can occur during peak demand periods. The hybrid cycles are compared to equivalently sized, co-located, independent geothermal, concentrating solar, and/or natural-gas power plants. The hybrid cycle tends to produce slightly more power than the standalone plants combined. However, the hybrid plant Levelized Cost of Energy (LCOE) is slightly higher than the LCOE of the combined standalone power plants for each of the case study locations investigated. Using the steam-topping cycle, organic Rankine cycle (ORC)-bottoming cycle hybrid plant design to combine a solar thermal resource and low- temperature geothermal resource (<120 degrees C) leads to a hybrid plant with a lower LCOE than a standalone geothermal-only system. Thus, hybrid plants may enable the economic development of geothermal resources in locations with low geothermal resource temperatures. However, in areas with higher geothermal resource temperatures (>120 degrees C), the geothermal-only plant has a lower LCOE than the hybrid cycle and thus could be developed without the need for solar heat addition. iv A geothermal-natural-gas reciprocating engine hybrid plant was evaluated for an Elk Hills, California case study location. The Elk Hills case study analysis indicates that when the natural-gas engine operates for more than 12 hours per day the hybrid plant can produce power at an LCOE lower than a standalone geothermal plant, and comparable to that of the standalone natural-gas reciprocating engine, while also reducing the carbon intensity of the power generated relative to the standalone natural-gas engine. This may represent a scenario in which the hybrid plant provides an opportunity for the deployment of a low-temperature geothermal resource that otherwise may have an LCOE too high to develop and operate as a standalone resource, while also reducing the carbon intensity of natural-gas generation sources. A "triple-hybrid" plant that combines natural gas, solar thermal, thermal energy storage, and geothermal was also investigated. A natural-gas combustion turbine (NGCT) is added to the geothermal-solar hybrid such that the hot exhaust gas from the gas turbine provides an alternative source of heat to the steam turbine of the hybrid cycle. Analysis results suggest that the triple-hybrid plant has a significantly higher energy generation and revenue than a standalone NGCT or the original geothermal-solar hybrid. The triple-hybrid design benefits most from using a smaller solar field so that the solar energy can be dispatched at the most valuable times available. The triple-hybrid plant also has a lower LCOE than the standalone NGCT. The triple-hybrid plant was evaluated making simple assumptions about the dispatch profile of the gas cycle, and more nuanced and realistic dispatching schedules should be analyzed in future work.

15 GEOTHERMAL ENERGY↗

A pressure gauge based on gas density measurement from analysis of the thermal noise of an atomic force microscope cantilever

We describe a gas-density gauge based on the analysis of the thermally-driven fluctuations of an atomic force microscope (AFM) cantilever. The fluctuations are modeled as a ring-down of a simple harmonic oscillator, which allows fitting of the resonance frequency and damping of the cantilever, which in turn yields the gas density. The pressure is obtained from the density using the known equation of state. In the range 10-220 kPa, the pressure readings from the cantilever gauge deviate by an average of only about 5% from pressure readings on a commercial gauge. The theoretical description we use to determine the pressure from the cantilever motion is based upon the continuum hypothesis, which sets a minimum pressure for our analysis. It is anticipated that the cantilever gauge could be extended to measure lower pressures given a molecular theoretical description. Alternatively, the gauge could be calibrated for use in the non-continuum range. Our measurement technique is similar to previous AFM cantilever measurements, but the analysis produces improved accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reducing the cost of CO{sub 2} capture from flue gases using pressure swing adsorption

Pressure swing adsorption (PSA) processes have been used extensively for gas separation, especially in the separation of hydrogen from CO{sub 2}, and in air purification. The objective of this paper is to examine the economic feasibility of pressure swing adsorption (PSA) for recovering CO{sub 2} from postcombustion power plant flue gas. The analysis considers both high-pressure feed and vacuum desorption using commercial adsorbent 13X, which has a working capacity of 2.2 mol/kg and CO{sub 2}/N{sub 2} selectivity of 54. The results show that using vacuum desorption reduces the capture cost from US$57 to US$51 per ton of CO{sub 2} avoided and is comparable in cost to CO{sub 2} capture using conventional MEA absorption of US$49 per ton of CO{sub 2} avoided. In this paper, a sensitivity analysis is also presented showing the effect on the capture cost with changes in process cycle; feed pressure and evacuation pressure; improvements the adsorbent characteristics; and selectivity and working capacity. The results show that a hypothetical adsorbent with a working capacity of 4.3 mol/kg and a CO{sub 2}/N{sub 2} selectivity of 150 can reduce the capture cost to US$30 per ton of CO{sub 2} avoided.

01 COAL, LIGNITE, AND PEAT↗

Numerical Analysis of Detonability Assessment in a Natural Gas-Air Fueled Rotating Detonation Engine

Rotating Detonation Engines (RDE) offer an alternative combustion strategy to replace conventional constant pressure combustion with a process that could produce a pressure gain without the use of a mechanical compressor. Recent numerical and experimental publications that consider air as the oxidizer have primarily focused on the ability of these annular combustors to sustain a stable continuous detonation wave when fueled by hydrogen. However, for this to be a viable consideration for the land-based power generation it is necessary to explore the ability to detonate natural gas and air within the confines of the annular geometry of an RDE. Previous studies on confined detonations have expressed the importance of permitting detonation cells to fully form within the combustor in order to achieve stability. This poses a challenge for natural gas–air fueled processes as their detonation cell size can be quite large even at moderate pressures. Despite the practical importance, only a few studies are available on natural gas detonations for air-breathing RDE applications. Moreover, the extreme thermodynamic condition (high temperature inside the combustor) allows limited accessibility inside the combustor for detailed experimental instrumentations, providing mostly single-point data. Recent experimental studies at the National Energy Technology Laboratory (NETL) have reported detonation failure at higher methane concentration in an air-breathing RDE fueled by natural gas-hydrogen fuel blends. This encourages to perform a detailed numerical investigation on the wave characteristics of detonation in a natural gas-air fueled RDE to understand the various aspects of instability associated with the natural gas-air detonation.This study is a numerical consideration of a methane-air fueled RDE with varying operating conditions to ascertain the ability to achieve a stable, continuous detonation wave. The simulations have been performed in a 2D unwrapped RDE geometry using the open-source CFD library “OpenFOAM” employing an unsteady pressure-based compressible reactive flow solver with a <em>k</em>–<em>ε</em> turbulence model in a structured rectangular grid system. Both reduced and detailed chemical kinetic models have been used to assess the effect of the chemistry on the detonation wave characteristics and the underlying flow features. A systematic grid sensitivity study has been conducted with various grid sizes to quantify the weakly stable overdriven detonation on a coarse mesh and oscillating features at fine mesh resolutions.The main focus of the current study is to investigate the effects of operating injection pressure on detonation wave characteristics of an air-breathing Rotating Detonation Engine (RDE) fueled with natural gas-hydrogen fuel blends. Wave speeds, peak pressures and temperatures, and dominant frequencies have been computed from the time histories. The flow structures were then visualized using 2D contours of temperature and species concentration.

Saha, Pankaj↗