Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fringe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Influence of substrate quality on structural properties of AlGaN/GaN superlattices grown by molecular beam epitaxy

Short-period AlGaN/GaN superlattices were established as versatile test structures to investigate the structural properties of molecular beam epitaxy (MBE)-grown GaN and AlGaN layers and their dependence on the GaN substrate quality. X-ray diffractometry data of the investigated superlattices allow access to relevant structural parameters such as aluminum mole fraction and layer thicknesses. The occurrence of theoretically predicted intense high-order satellite peaks and pronounced interface fringes in the diffraction pattern reflects abrupt interfaces and perfect 2-dimensional growth resulting in smooth surfaces. The data unambiguously demonstrate that the structural quality of the MBE grown layers is limited by the structural properties of the GaN substrate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of the second-order nonlinear optical properties of Cs{sub 2}TeMo{sub 3}O{sub 12} single crystal

The complete set of second-order nonlinear optical (NLO) coefficients of Cs{sub 2}TeMo{sub 3}O{sub 12} single crystals were obtained using the Maker Fringe techniques. The NLO coefficients d{sub 32} and d{sub 33} were measured to be on the order of 6.8 and 6.5 pm/V, respectively. Irradiated by 1064 nm laser, the crystal is phase-matchable, and its effective nonlinear coefficient is 4.6 pm/V for type I phase matching at θ = 42.7°. The relationship between the second-order nonlinear properties and the crystal structure is also discussed. Considering its wide transmission range, phase matching, and large effective NLO coefficient, Cs{sub 2}TeMo{sub 3}O{sub 12} is a good candidate for IR NLO application.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A simple scheme for injection and extraction in compact rings

There has been great interest in building compact synchrotrons for various applications, for example, inverse Compton scattering X-ray sources. However, the beam injection and extraction in compact rings require careful design for the lack of space. In this paper, we propose a simple combined injection-extraction scheme exploiting the fringe field of existing dipole magnets instead of additional septum magnets. This scheme is illustrated by using the 4.8 m ring proposed for Tsinghua Thomson scattering X-ray source as an example. Particle tracking is applied to demonstrate the validity of this scheme.

43 PARTICLE ACCELERATORS↗

Single beam Fourier transform digital holographic quantitative phase microscopy

Quantitative phase contrast microscopy reveals thickness or height information of a biological or technical micro-object under investigation. The information obtained from this process provides a means to study their dynamics. Digital holographic (DH) microscopy is one of the most used, state of the art single-shot quantitative techniques for three dimensional imaging of living cells. Conventional off axis DH microscopy directly provides phase contrast images of the objects. However, this process requires two separate beams and their ratio adjustment for high contrast interference fringes. Also the use of two separate beams may make the system more vulnerable to vibrations. Single beam techniques can overcome these hurdles while remaining compact as well. Here, we describe the development of a single beam DH microscope providing whole field imaging of micro-objects. A hologram of the magnified object projected on to a diffuser co-located with a pinhole is recorded with the use of a commercially available diode laser and an arrayed sensor. A Fourier transform of the recorded hologram directly yields the complex amplitude at the image plane. The method proposed was investigated using various phase objects. It was also used to image the dynamics of human red blood cells in which sub-micrometer level thickness variation were measurable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diffusion-driven precipitate growth and ripening of oxygen precipitates in boron doped silicon by dynamical x-ray diffraction

X-ray Pendellösung fringes from three silicon single crystals measured at 900 °C are analyzed with respect to density and size of oxygen precipitates within a diffusion-driven growth model and compared with TEM investigations. It appears that boron doped (p+) material shows a higher precipitate density and a higher strain than moderately (p-) boron crystals. In-situ diffraction reveals a diffusion-driven precipitate growth followed by a second growth regime in both materials. An interpretation of the second growth regime in terms of Ostwald ripening yields surface energy values (around 70 erg/cm{sup 2}) similar to published data. Further, an increased nucleation rate by a factor of ∼13 is found in the p+ sample as compared to a p- sample at a nucleation temperature of 450 °C.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lunar occultation observation of μ Sgr: A progress report

Lunar Occultation (LO) is an event where limb of the Moon passing over a particular heavenly bodies such as stars, asteroids, or planets. In other words, during the event, stars, asteroids and planets are occulted by the Moon. When occulted objects contact the lunar limb, there will be a diffraction fringe(s) which can be measured photometrically, until the signal vanishes into noise. This event will give us a valuable information about binarities (of stars) and/or angular diameters estimation (of stars, planets, asteroids) in milliarcsecond resolution, by fitting with theoretical LO pattern. CCDs are common for LO observation because of its fast read out, and recently are developed for sub-meter class telescope. In this paper, our LO observation attempt of μ Sgr and its progress report are presented. The observation was conducted on July 30{sup th}, 2012 at Bosscha Observatory, Indonesia, using 45cm f/12 GOTO telescope combined with ST-9 XE CCD camera and Bessel B filter. We used drift-scan method to obtain light curve of the star as it was disappearing behind Moon's dark limb. Our goal is to detect binarity (or multiplicity) of this particular object.

79 ASTRONOMY AND ASTROPHYSICS↗

Note: Large area deposition of Rh single and Rh/W/Cu multilayer thin films on stainless steel substrate by pulsed laser deposition technique

Mirror like thin films of single layer Rh and multilayer Rh/W/Cu are deposited on highly polished 50 mm diameter stainless steel substrate by Pulsed Laser Deposition (PLD) technique for first mirror application in fusion reactors. For this, the conventional PLD technique has been modified by incorporating substrate rastering stage for large area deposition via PLD. Process optimization to achieve uniformity of deposition as estimated from fringe visibility and thickness is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photo-induced tunneling currents in MOS structures with various HfO{sub 2}/SiO{sub 2} stacking dielectrics

In this study, the current conduction mechanisms of structures with tandem high-k dielectric in illumination are discussed. Samples of Al/SiO{sub 2}/Si (S), Al/HfO{sub 2}/SiO{sub 2}/Si (H), and Al/3HfO{sub 2}/SiO{sub 2}/Si (3H) were examined. The significant observation of electron traps of sample H compares to sample S is found under the double bias capacitance-voltage (C-V) measurements in illumination. Moreover, the photo absorption sensitivity of sample H is higher than S due to the formation of HfO{sub 2} dielectric layer, which leads to larger numbers of carriers crowded through the sweep of V{sub G} before the domination of tunneling current. Additionally, the HfO{sub 2} dielectric layer would block the electrons passing through oxide from valance band, which would result in less electron-hole (e{sup −}-h{sup +}) pairs recombination effect. Also, it was found that both of the samples S and H show perimeter dependency of positive bias currents due to strong fringing field effect in dark and illumination; while sample 3H shows area dependency of positive bias currents in strong illumination. The non-uniform tunneling current through thin dielectric and through HfO{sub 2} stacking layers are importance to MOS(p) tunneling photo diodes.

36 MATERIALS SCIENCE↗

High-precision instrument for measuring the surface tension, viscosity and surface viscoelasticity of liquids using ripplon surface laser-light scattering with tunable wavelength selection

Here we describe our new high-precision instrument that simultaneously measures the surface tension, viscosity, and surface viscoelasticity of liquids. The instrument works on the ripplon surface-laser light scattering principle and operates with an automatically tunable selection of ripplon wavelength from 4 to 1500 μm, which corresponds to the frequency range of observing surface phenomena from approximately 400 Hz to 3 MHz in the case of water. The heterodyne technique instrument uses a reference laser beam which intersects at an arbitrarily adjustable angle with a vertically directed probing beam. For the determination of the wavelength of selected ripplons we substituted with the interference fringe spacing, measured using a high-resolution beam profiler. To extract reliable surface tension and viscosity data from the experimentally obtained spectrum shape for a selected wavelength of ripplon, we developed an algorithm to calculate the exact solution of the dispersion equation. The uncertainties of surface tension and viscosity measurement were confirmed through the measurement of seven pure Newtonian liquids at 25 °C measured with the selected wavelength of ripplon from 40 μm to 467 μm. To verify the genuine capability of the tunable wavelength selection of ripplon, we measured the surface elasticity of soluble surface molecular layers spread on pentanoic acid solutions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultraviolet laser patterning of porous silicon

This work reports on the fabrication of 1D fringed patterns on nanostructured porous silicon (nanoPS) layers (563, 372, and 290 nm thick). The patterns are fabricated by phase-mask laser interference using single pulses of an UV excimer laser (193 nm, 20 ns pulse duration). The method is a single-step and flexible approach to produce a large variety of patterns formed by alternate regions of almost untransformed nanoPS and regions where its surface has melted and transformed into Si nanoparticles (NPs). The role of laser fluence (5–80 mJ cm{sup −2}), and pattern period (6.3–16 μm) on pattern features and surface structuring are discussed. The results show that the diameter of Si NPs increases with fluence up to a saturation value of 75 nm for a fluence ≈40 mJ cm{sup −2}. In addition, the percentage of transformed to non-transformed region normalized to the pattern period follows similar fluence dependence regardless the period and thus becomes an excellent control parameter. This dependence is fitted within a thermal model that allows for predicting the in-depth profile of the pattern. The model assumes that transformation occurs whenever the laser-induced temperature increase reaches the melting temperature of nanoPS that has been found to be 0.7 of that of crystalline silicon for a porosity of around 79%. The role of thermal gradients across the pattern is discussed in the light of the experimental results and the calculated temperature profiles, and shows that the contribution of lateral thermal flow to melting is not significant for pattern periods ≥6.3 μm.

36 MATERIALS SCIENCE↗

Mode imaging and loss evaluation of semiconductor waveguides

An imaging and loss evaluation method for semiconductor waveguides coupled with non-doped quantum wells is presented. Using the internal emission of the wells as a probe light source, the numbers and widths of the modes of waveguides with various ridge sizes were evaluated by CCD imaging, and the obtained values were consistent with effective index method calculation. Waveguide internal losses were obtained from analyses of the Fabry-Pérot fringes of waveguide emission spectra. We quantified the quality of 29 single-mode waveguide samples as an internal loss and variation of 10.2 ± 0.6 cm{sup −1}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The application of Raman laser in gravity measurement and metrology

Atom Interferometry is proved to be a potential method for measuring the acceleration of atoms due to Gravity, we are now building a feasible system of cold atom gravimeter, it is based on the atom interferometry technology by coherently manipulating the cold atoms in a fountain (with a height of 1m) with specific Raman lasers, the cold atom wave packet is splitted, combined, and then re-splitted in the process. Then the atomic wave packet will acquire different phase because of the different evolution path. The precise acceleration can be deduced through the precision measurement of atomic interference fringes phase, and this will be a high precision standard of acceleration. At present, the preparation of Raman laser and the precise control of the laser Frequency have been finished, and they have been proved to meet the requirements of the experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dispersion interferometer using modulation amplitudes on LHD (invited)

Since a dispersion interferometer is insensitive to mechanical vibrations, a vibration compensation system is not necessary. The CO{sub 2} laser dispersion interferometer with phase modulations on the Large Helical Device utilizes the new phase extraction method which uses modulation amplitudes and can improve a disadvantage of the original dispersion interferometer: measurement errors caused by variations of detected intensities. The phase variation within ±2 × 10{sup 17} m{sup −3} is obtained without vibration compensation system. The measured line averaged electron density with the dispersion interferometer shows good agreement with that with the existing far infrared laser interferometer. Fringe jump errors in high density ranging up to 1.5 × 10{sup 20} m{sup −3} can be overcome by a sufficient sampling rate of about 100 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel femtosecond-gated, high-resolution, frequency-shifted shearing interferometry technique for probing pre-plasma expansion in ultra-intense laser experiments

Ultra-intense laser-matter interaction experiments (>10{sup 18} W/cm{sup 2}) with dense targets are highly sensitive to the effect of laser “noise” (in the form of pre-pulses) preceding the main ultra-intense pulse. These system-dependent pre-pulses in the nanosecond and/or picosecond regimes are often intense enough to modify the target significantly by ionizing and forming a plasma layer in front of the target before the arrival of the main pulse. Time resolved interferometry offers a robust way to characterize the expanding plasma during this period. We have developed a novel pump-probe interferometry system for an ultra-intense laser experiment that uses two short-pulse amplifiers synchronized by one ultra-fast seed oscillator to achieve 40-fs time resolution over hundreds of nanoseconds, using a variable delay line and other techniques. The first of these amplifiers acts as the pump and delivers maximal energy to the interaction region. The second amplifier is frequency shifted and then frequency doubled to generate the femtosecond probe pulse. After passing through the laser-target interaction region, the probe pulse is split and recombined in a laterally sheared Michelson interferometer. Importantly, the frequency shift in the probe allows strong plasma self-emission at the second harmonic of the pump to be filtered out, allowing plasma expansion near the critical surface and elsewhere to be clearly visible in the interferograms. To aid in the reconstruction of phase dependent imagery from fringe shifts, three separate 120° phase-shifted (temporally sheared) interferograms are acquired for each probe delay. Three-phase reconstructions of the electron densities are then inferred by Abel inversion. This interferometric system delivers precise measurements of pre-plasma expansion that can identify the condition of the target at the moment that the ultra-intense pulse arrives. Such measurements are indispensable for correlating laser pre-pulse measurements with instantaneous plasma profiles and for enabling realistic Particle-in-Cell simulations of the ultra-intense laser-matter interaction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical system for liquid level measurements

This work describes the development of a novel laser instrument for non-contact liquid level measurements. The physical principle of operation is based on the self-mixing effect induced in the laser diode by modulating the laser wavelength. The frequency main tone of the resulting fringes is proportional to the absolute target distance. A high speed FPGA (Field Programmable Gate Array) electronic performs the data acquisition and elaboration. The high elaboration/acquisition speed improves the chance of acquiring good signal also on a moving liquid target. The optical characteristics of the liquid surface have been studied in order to identify the optimal optical configuration when the surface is flat as well as when the surface is rippled. The final low-cost instrument works in real time and is able to track a filling process with 2.5 cm/s of speed, with resolution better than 1 mm for distances up to 50 cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-direct-driven quasi-isentropic experiments on aluminum

Laser-direct-driven ramp compression experiments were performed on long temporally shaped laser pulses based on an analytical isentropic compression model. Upper pressure limits, the ablation pressure scaling law, and stress-density curves were studied. The validity of the analytical model used, the ablation pressure scaling law, and the phenomena of missing line-imaging velocity interferometer (VISAR) fringes in the experimental results are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structurally inhomogeneous nanoparticulate catalysts in cobalt-catalyzed carbon nanotube growth

The structure of nanoparticulate catalysts involved in cobalt-catalyzed chemical vapor deposition growth of carbon nanotubes (CNTs) was investigated by in situ environmental transmission electron microscopy (ETEM). In contrast to previous studies, the analyses of ETEM images showed that the nanoparticulate catalysts were structurally inhomogeneous during CNT growth in the source gas of acetylene at a rate of pressure increase of about 3 Pa/h and at 550 °C. The lattice fringes observed in the nanoparticulate catalysts can be accounted for by not a single crystalline structure but by several possible pairs of structures including pure Co and cobalt carbides. The inhomogeneous structures were unstable with time. The possible origin of the inhomogeneous structures is discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Field effect in the quantum Hall regime of a high mobility graphene wire

In graphene-based electronic devices like in transistors, the field effect applied thanks to a gate electrode allows tuning the charge density in the graphene layer and passing continuously from the electron to the hole doped regime across the Dirac point. Homogeneous doping is crucial to understand electrical measurements and for the operation of future graphene-based electronic devices. However, recently theoretical and experimental studies highlighted the role of the electrostatic edge due to fringing electrostatic field lines at the graphene edges [P. Silvestrov and K. Efetov, Phys. Rev. B 77, 155436 (2008); F. T. Vasko and I. V. Zozoulenko, Appl. Phys. Lett. 97, 092115 (2010)]. This effect originates from the particular geometric design of the samples. A direct consequence is a charge accumulation at the graphene edges giving a value for the density, which deviates from the simple picture of a plate capacitor and also varies along the width of the graphene sample. Entering the quantum Hall regime would, in principle, allow probing this accumulation thanks to the extreme sensitivity of this quantum effect to charge density and the charge distribution. Moreover, the presence of an additional and counter-propagating edge channel has been predicted [P. Silvestrov and K. Efetov, Phys. Rev. B 77, 155436 (2008)] giving a fundamental aspect to this technological issue. In this article, we investigate this effect by tuning a high mobility graphene wire into the quantum Hall regime in which charge carriers probe the electrostatic potential at high magnetic field close to the edges. We observe a slight deviation to the linear shift of the quantum Hall plateaus with magnetic field and we study its evolution for different filling factors, which correspond to different probed regions in real space. We discuss the possible origins of this effect including an increase of the charge density towards the edges.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗