Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Conjugate Heat Transfer Analysis of the Supercritical CO2 Based Counter Flow Compact 3D Heat Exchangers

Compact heat exchangers using supercritical fluids such as CO2 are preferred due to their high heat transfer capacity and smaller footprint. Three-dimensional conjugate forced convection heat transfer analysis was performed on several shell-and-tube counter-flow microchannel heat exchangers. Numerical simulations were conducted to test effect of change in mass flow rate, hydraulic diameter and various cross sections on the heat transfer. Increasing mass flow rate improved heat transfer up to a maximum value and then decreased downstream with increasing turbulence. Maximum heat transfer was obtained for the micro channel with the smallest hydraulic diameter. Amongst the cross sections analyzed (circular, square, circular with radial ribs, and square with radial ribs), the most uniform distribution of temperature and maximum heat transfer were obtained for circular cross section with radial ribs. An optimally efficient operation of such a heat exchanger can be attained by considering these factors during multi-objective constrained optimization of geometric parameters and requirements for additive manufacturing of such compact heat exchangers.

Chitale, Janhavi↗

Summary Report: Development of a New ASTM Standard Test Method for Phase Change Materials

An ASTM International task group was formed with representatives from research organizations, PCM and insulation manufacturers, testing laboratories, etc., to develop an ASTM standard test method, using a heat flow meter apparatus (HFMA), to make heat-flow measurements under prescribed dynamic, or non steady-state, conditions. The HFMA is typically used for measuring steady-state thermal transmission properties of materials, following ASTM C518. The new ‘dynamic’ test method is based on a modification of the C518 test method, for measuring volumetric specific heat of regular (i.e. with no PCM) thermal insulation materials. The proposed test method describes the methodology for using a HFMA for measuring thermal storage properties of phase change materials and products. It requires the measurement of non-steady-state heat flow into or out of a flat slab specimen to determine the stored energy (i.e. enthalpy) change as a function of temperature. In particular, this test method is intended to measure the sensible and latent heat storage capacity of products incorporating phase-change materials (PCM). The thermal storage capacity of a PCM is well defined via four parameters: specific heats of both solid and liquid phases, phase change temperature(s) and phase change enthalpy. This report provides brief summaries of the proposed standard test method and the standard development related activities at Oak Ridge National Laboratory (ORNL) during fiscal year 2013 (FY13). The draft standard document is also provided as an appendix.

dynamic testing↗

FeCoSiBNbCu bulk metallic glass with large compressive deformability studied by time-resolved synchrotron X-ray diffraction

By adding 0.5 at. % Cu to the strong but brittle [(Fe{sub 0.5}Co{sub 0.5}){sub 0.75}Si{sub 0.05}B{sub 0.20}]{sub 96}Nb{sub 4} bulk metallic glass, fully amorphous rods with diameters up to 2 mm were obtained. The monolithic samples with 1 mm diameter revealed a fracture strain of 3.80% and a maximum stress of 4143 MPa upon compression, together with a slight work-hardening behavior. SEM micrographs of fractured samples did neither reveal any shear bands on the lateral surface nor the typical vein patterns which characterize ductile fracture. However, some layers appear to have flowed and this phenomenon took place before the brittle final fracture. An estimate of the temperature rise ΔT in the shear plane gives 1039 K, which is large enough to melt a layer of 120 nm. The overall performance and the macroscopic plastic strain depend on the interaction between cleavage-like and viscous flow-like features. Mechanical tests performed in-situ under synchrotron radiation allowed the calculation of the strain tensor components, using the reciprocal-space data and analyzing the shift of the first (the main) and the second broad peak positions in the X-ray diffraction patterns. The results revealed that each atomic shell may have a different stiffness, which may explain the macroscopic compressive plastic deformation. Also, there were no signs of (nano) crystallization induced by the applied stress, but the samples preserve a monolithic amorphous structure until catastrophic failure occurs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of Hydrodynamic Flows in Imploding Fusion Plasmas on the National Ignition Facility [plus supplemental information]

Inertial confinement fusion implosions designed to have minimal fluid motion at peak compression often show significant linear flows in the laboratory, attributable per simulations to percent-level imbalances in the laser drive illumination symmetry. In this work, we present experimental results which intentionally varied the mode 1 drive imbalance by up to 4% to test hydrodynamic predictions of flows and the resultant imploded core asymmetries and performance, as measured by a combination of DT neutron spectroscopy and high-resolution x-ray core imaging. Neutron yields decrease by up to 50%, and anisotropic neutron Doppler broadening increases by 20%, in agreement with simulations. Furthermore, a tracer jet from the capsule fill-tube perturbation that is entrained by the hot-spot flow confirms the average flow speeds deduced from neutron spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma parameters and electromagnetic forces induced by the magneto hydro dynamic interaction in a hypersonic argon flow experiment

This work proposes an experimental analysis on the magneto hydro dynamic (MHD) interaction induced by a magnetic test body immersed into a hypersonic argon flow. The characteristic plasma parameters are measured. They are related to the voltages arising in the Hall direction and to the variation of the fluid dynamic properties induced by the interaction. The tests have been performed in a hypersonic wind tunnel at Mach 6 and Mach 15. The plasma parameters are measured in the stagnation region in front of the nozzle of the wind tunnel and in the free stream region at the nozzle exit. The test body has a conical shape with the cone axis in the gas flow direction and the cone vertex against the flow. It is placed at the nozzle exit and is equipped with three permanent magnets. In the configuration adopted, the Faraday current flows in a closed loop completely immersed into the plasma of the shock layer. The electric field and the pressure variation due to MHD interaction have been measured on the test body walls. Microwave adsorption measurements have been used for the determination of the electron number density and the electron collision frequency. Continuum recombination radiation and line radiation emissions have been detected. The electron temperature has been determined by means of the spectroscopic data by using different methods. The electron number density has been also determined by means of the Stark broadening of H{sub {alpha}} and the H{sub {beta}} lines. Optical imaging has been utilized to visualize the pattern of the electric current distribution in the shock layer around the test body. The experiments show a considerable effect of the electromagnetic forces produced by the MHD interaction acting on the plasma flow around the test body. A comparison of the experimental data with simulation results shows a good agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deposition Mitigation in Flowing Systems Using Coatings

Abstract In pipelines, solid compounds including gas hydrates and asphaltenes may form/precipitate and accumulate on the pipe surface, leading to a gradual stenosis of the flowline. As a result, production may become increasingly difficult or possibly interrupted if mitigation efforts are not enacted. Typically, injected chemicals will either inhibit nucleation or dissolve already-formed deposits to restore original flow conditions back to the system; however, this can be a costly option. More recently, management strategies have been proposed where solids are handled in a controlled fashion rather than completely avoided. One such proposed management strategy as suggested for wall deposit formation is the use of coatings. Here, coatings can provide a low surface energy layer on the pipe wall, which restricts liquid and solid accumulation, allowing for a stable slurry flow through a system. This study utilized two material formulations within several experimental setups to probe their interactions with water, gas hydrate, asphaltene, and crude oil. The results serve as part of an ongoing investigation into a surface treatment formulation that can be tested on larger-scale, fully flowing systems, which could be ultimately implemented into real-world production scenarios. The first surface treatment is a water-based polymeric surface that displays repellency to both oil and water phases (omniphobic). Testing of this material consisted of water contact angle measurements and static asphaltene/crude oil deposition quantification at atmospheric conditions, as well as visual confirmation of hydrate deposition prevention at high pressures. Additionally, an experimental superomniphobic surface treatment, which displays elevated resiliency to both water and hydrocarbons, was also examined within the asphaltene/crude oil test as a comparison to the omniphobic surface treatment. Static contact angle results showed that the omniphobic surface treatment had reduced surface interaction with water droplets in air, increasing the low contact angles of corroded surfaces (0-31°) to slightly hydrophobic conditions of 91.5°. Additionally, rocking cells tests indicated that these omniphobic surface treatments may prevent gas hydrate deposition under high-pressure, semi-flowing conditions. Multiple tests found that formed hydrate agglomerants did not deposit for at least 48 and 72 hours. Finally, static deposition tests conducted in crude oil with forced asphaltene precipitation suggested that the omniphobic surface treatment displayed a resistance to both asphaltenes and crude oil when compared to untreated and superomniphobic surfaces.

03 NATURAL GAS↗

Multiscale solute transport upscaling for a three‐dimensional hierarchical porous medium

Abstract A laboratory‐generated hierarchical, fully heterogeneous aquifer model (FHM) provides a reference for developing and testing an upscaling approach that integrates large‐scale connectivity mapping with flow and transport modeling. Based on the FHM, three hydrostratigraphic models (HSMs) that capture lithological (static) connectivity at different resolutions are created, each corresponding to a sedimentary hierarchy. Under increasing system ln K variances (0.1, 1.0, 4.5), flow upscaling is first conducted to calculate equivalent hydraulic conductivity for individual connectivity (or unit) of the HSMs. Given the computed flow fields, an instantaneous, conservative tracer test is simulated by all models. For the HSMs, two upscaling formulations are tested based on the advection‐dispersion equation (ADE), implementing space versus time‐dependent macrodispersivity. Comparing flow and transport predictions of the HSMs against those of the reference model, HSMs capturing connectivity at increasing resolutions are more accurate, although upscaling errors increase with system variance. Results suggest: (1) by explicitly modeling connectivity, an enhanced degree of freedom in representing dispersion can improve the ADE‐based upscaled models by capturing non‐Fickian transport of the FHM; (2) when connectivity is sufficiently resolved, the type of data conditioning used to model transport becomes less critical. Data conditioning, however, is influenced by the prediction goal; (3) when aquifer is weakly‐to‐moderately heterogeneous, the upscaled models adequately capture the transport simulation of the FHM, despite the existence of hierarchical heterogeneity at smaller scales. When aquifer is strongly heterogeneous, the upscaled models become less accurate because lithological connectivity cannot adequately capture preferential flows; (4) three‐dimensional transport connectivities of the hierarchical aquifer differ quantitatively from those analyzed for two‐dimensional systems.

Zhang, Mingkan↗

Development of a Forced-Convection Liquid-Fluoride-Salt Test Loop

A small forced-convection molten-fluoride-salt loop is being constructed at Oak Ridge National Laboratory to examine the heat transfer behavior of FLiNaK salt in a heated pebble bed. Objectives of the experiment include reestablishing infrastructure needed for fluoride-salt loop testing, developing a unique inductive heating technique for performing heat transfer (or other) experiments, measuring heat transfer characteristics in a liquid-fluoride-salt-cooled pebble bed, and demonstrating the use of silicon carbide (SiC) as a structural component for salt systems. The salt loop will consist of an Inconel 600 piping system, a sump-type pump, a SiC test section, and an air-cooled heat exchanger, as well as auxiliary systems needed to pre-heat the loop, transport salt into and out of the loop, and maintain an inert cover gas over the salt. A 30,000 Hz inductive heating system will be used to provide up to 250 kW of power to a 15 cm diameter SiC test section containing a packed bed of 3 cm graphite spheres. A SiC-to-Inconel 600 joint will use a conventional nickel/grafoil spiral wound gasket sandwiched between SiC and Inconel flanges. The loop system can provide up to 4.5 kg/s of salt flow at a head of 0.125 MPa and operate at a pressure just above atmospheric. Pebble Reynolds numbers of up to 2600 are possible with this configuration. A sump system is provided to drain and store the salt when not in use. Instrumentation on the loop will include pressure, temperature, and flow measurements, while the test section will be instrumented to provide pebble and FLiNaK temperatures.

36 MATERIALS SCIENCE↗

A novel target-type low pressure drop bidirectional optoelectronic air flow sensor for infant artificial ventilation: Measurement principle and static calibration

An optoelectronic target-type volumetric air flow-rate transducer for bidirectional measurements is presented. The sensor is composed of a T-shaped target and two nominally identical LED-photodiode couples which are operated in differential mode. The sensitive surfaces of the photodiodes are differentially shadowed by the deflection of the target, which in turn depends on the gas flow-rate. The principle of operation is described in mathematical terms and the design parameters have been optimized in order to obtain the highest sensitivity along with minimal pressure drop and reduced dimensions. The sensor is placed in a 20 mm diameter hose and was tested with air flow-rate in the typical temperature range of mechanical ventilation between 20 and 40 deg. C. The theoretical model was validated through experiments carried out in the volumetric flow range from -7.0 to +7.0 l min{sup -1}. The nonlinear behavior allows sensitivities equal to 0.6 V l{sup -1} min for flow rates ranging from -2.0 to +2.0 l min{sup -1}, equal to 2.0 V l{sup -1} min for flow rates ranging from -3.0 to -2.0 l min{sup -1} and from +2.0 to +3.0 l min{sup -1}, up to 5.7 V l{sup -1} min at higher flow rates ranging from -7.0 to -3.0 l min{sup -1} and from +3.0 to +7.0 l min{sup -1}. The linear range extends from 3.0 to 7.0 l min{sup -1} with constant sensitivity equal to 5.7 V l{sup -1} min. The sensor is able to detect a flow-rate equal to 1.0 l min{sup -1} with a sensitivity of about 400 mV l{sup -1} min. The differential nature of the output minimizes the influence of the LEDs' power supply variations and allows to obtain a repeatability in the order of 3% of full scale output. The small pressure drop produced by the sensor placed in-line the fluid stream, of about 2.4 Pa at 7 l min{sup -1}, corresponds to a negligible fluid dynamic resistance lower than 0.34 Pa l{sup -1} min.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Permeability Ternary Palladium Alloy Membranes with Improved Sulfur and Halide Tolerances

The project team consisting of Southwest Research Institute{reg_sign} (SwRI{reg_sign}), Georgia Institute of Technology (GT), the Colorado School of Mines (CSM), TDA Research, and IdaTech LLC was focused on developing a robust, poison-tolerant, hydrogen selective free standing membrane to produce clean hydrogen. The project completed on schedule and on budget with SwRI, GT, CSM, TDA and IdaTech all operating independently and concurrently. GT has developed a robust platform for performing extensive DFT calculations for H in bulk palladium (Pd), binary alloys, and ternary alloys of Pd. Binary alloys investigated included Pd96M4 where M = Li, Na, Mg, Al, Si, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Y, Zr, Nb, Mo, Tc, Ru, Rh, Ag, Cd, In, Sn, Sb, Te, Hf, Ta, W, Re, Os, Ir, Pt, Au, Tl, Pb, Bi, Ce, Sm, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu. They have also performed a series of calculations on Pd{sub 70}Cu{sub 26}Ag{sub 4}, Pd{sub 70}Cu{sub 26}Au{sub 4}, Pd{sub 70}Cu{sub 26}Ni{sub 4}, Pd{sub 70}Cu{sub 26}Pt{sub 4}, and Pd{sub 70}Cu{sub 26}Y{sub 4}. SwRI deposited and released over 160 foils of binary and ternary Pd alloys. There was considerable work on characterizing and improving the durability of the deposited foils using new alloy compositions, post annealing and ion bombardment. The 10 and 25 {micro}m thick films were sent to CSM, TDA and IdaTech for characterization and permeation testing. CSM conducted over 60 pure gas permeation tests with SwRI binary and ternary alloy membranes. To date the PdAu and PdAuPt membranes have exhibited the best performance at temperatures in the range of 423-773 C and their performance correlates well with the predictions from GT. TDA completed testing under the Department of Energy (DOE) WGS conditions on over 16 membranes. Of particular interest are the PdAuPt alloys that exhibited only a 20% drop in flux when sulfur was added to the gas mixture and the flux was completely recovered when the sulfur flow was stopped. IdaTech tested binary and ternary membranes on a simulated flue gas stream and experienced significant difficulty in mounting and testing the sputter deposited membranes. IdaTech was able to successfully test PdAu and PdAuPt membranes and saw similar sulfur tolerance to what TDA found. The Program met all the deliverables on schedule and on budget. Over ten presentations at national and international conferences were made, four papers were published (two in progress) in technical journals, and three students (2 at GT and 1 at CSM) completed their doctorates using results generated during the course of the program. The three major findings of program were; (1) the DFT modeling was verified as a predictive tool for the permeability of Pd based ternary alloys, (2) while magnetron sputtering is useful in precisely fabricating binary and ternary alloys, the mechanical durability of membranes fabricated using this technique are inferior compared to cold rolled membranes and this preparation method is currently not ready for industrial environments, (3) based on both modeling and experimental verification in pure gas and mixed gas environments PdAu and PdAuPt alloys were found to have the combination of the highest permeability and tolerance to sulfur.

08 HYDROGEN↗

Locally adaptive artificial viscosity strategies for Lagrangian hydrodynamics

To accurately model inviscid flow with shock waves using staggered-grid Lagrangian hydrodynamics, artificial viscosity is introduced to convert kinetic energy into internal energy, thereby providing a mechanism to generate the required entropy increase across shocks. In this paper, we propose a new method for constructing an adaptive, artificial viscosity in the context of one-dimensional, staggered-grid Lagrangian hydrodynamics. Our adaptive, artificial viscosity is defined in terms of two parameters that depend on density locally in a neighborhood around a shock, and hence, vary cell-by-cell. Our methodology is based on building a reference set of pre-computed optimal, globally constant artificial viscosity coefficients for a family of isolated shock test problems. For arbitrary flows, the evaluation of the unknown coefficients is automated by first estimating shock intensity locally, and second computing the corresponding adaptive parameter value via interpolation over the data from the pre-computed reference set of optimal, globally constant coefficient values. To illustrate the performance of our new approach, we compare our results against two existing methods. The first method is a limiter-based approach, which relies on estimating velocity gradients of the flow, and the second method is utilized in several commercial codes. Finally, we demonstrate that our new adaptive methodology produces more accurate results for a variety of tests with propagating shock waves, as well as for the aforementioned family of isolated shock problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integral Reactor Containment Condensation Model and Experimental Validation

This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). In the three years of investigation duration, following the original proposal, the planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). A film flow model was developed for the scaling analysis, and the results suggest that the 1/3 scaled test facility covers large portion of laminar film flow, leading to a lower average heat transfer coefficient comparing to the prototypic value. Although it is conservative in reactor safety analysis, the significant reduction of heat transfer coefficient (50%) could under estimate the prototypic condensation heat transfer rate, resulting in inaccurate prediction of the decay heat removal capability. Further investigation is thus needed to quantify the scaling distortion for safety analysis code validation. Experimental investigations were performed in the existing MASLWR test facility at OrST with minor modifications. A total of 13 containment condensation tests were conducted for pressure ranging from 4 to 21 bar with three different static inventories of non-condensable gas. Condensation and heat transfer rates were evaluated employing several methods, notably from measured temperature gradients in the HTP as well as measured condensate formation rates. A detailed mass and energy accounting was used to assess the various measurement methods and to support simplifying assumptions required for the analysis. Condensation heat fluxes and heat transfer coefficients are calculated and presented as a function of pressure to satisfy the objectives of this investigation. The major conclusions for those tests are summarized below: (1) In the steam blow-down tests, the initial condensation heat transfer process involves the heating-up of the containment heat transfer plate. An inverse heat conduction model was developed to capture the rapid transient transfer characteristics, and the analysis method is applicable to SMR safety analysis. (2) The average condensation heat transfer coefficients for different pressure conditions and non-condensable gas mass fractions were obtained from the integral test facility, through the measurements of the heat conduction rate across the containment heat transfer plate, and from the water condensation rates measurement based on the total energy balance equation. 15 (3) The test results using the measured HTP wall temperatures are considerably lower than popular condensation models would predict mainly due to the side wall conduction effects in the existing MASLWR integral test facility. The data revealed the detailed heat transfer characteristics of the model containment, important to the SMR safety analysis and the validation of associated evaluation model. However this approach, unlike separate effect tests, cannot isolate the condensation heat transfer coefficient over the containment wall, and therefore is not suitable for the assessment of the condensation heat transfer coefficient against system pressure and noncondensable gas mass fraction. (4) The average condensation heat transfer coefficients measured from the water condensation rates through energy balance analysis are appropriate, however, with considerable uncertainties due to the heat loss and temperature distribution on the containment wall. With the consideration of the side wall conduction effects, the results indicate that the measured heat transfer coefficients in the tests is about 20% lower than the prediction of Dehbi’s correlation, mainly due to the side wall conduction effects. The investigation also indicates an increase in the condensation heat transfer coefficient at high containment pressure conditions, but the uncertainties invoked with this method appear to be substantial. (5) Non-condensable gas in the tests has little effects on the condensation heat transfer at high elevation measurement ports. It does affect the bottom measurements near the water level position. The results suggest that the heavier non-condensable gas is accumulated in the lower portion of the containment due to stratification in the narrow containment space. The overall effects of the non-condensable gas on the heat transfer process should thus be negligible for tall containments of narrow condensation spaces in most SMR designs. Therefore, the previous correlations with noncondensable gas effects are not appropriate to those small SMR containments due to the very poor mixing of steam and non-condensable gas. The MELCOR simulation results agree with the experimental data reasonably well. However, it is observed that the MELCOR overpredicts the heat flux for all analyzed tests. The MELCOR predicts that the heat fluxes for CCT’s approximately range from 30 to 45 kW/m2 whereas the experimental data (averaged) ranges from about 25 to 40 kW/m2. This may be due to the limited availability of liquid film models included in MELCOR. Also, it is believed that due to complex test geometry, measured temperature gradients across the heat transfer plate may have been underestimated and thus the heat flux had been underestimated. The MELCOR model predicts a film thickness on the order of 100 microns, which agrees very well with film flow model developed in this study for scaling analysis. However, the expected differences in film thicknesses for near vacuum and near atmospheric test conditions are not significant. Further study on the behavior of condensate film is expected to refine the simulation results. Possible refinements include but are not limited to, the followings: CFD simulation focusing on the liquid film behavior and benchmarking with experimental analyses for simpler geometries. 16 1 INTRODUCTION This NEUP funded project, NEUP 12-3630, is for experimental, numerical and analytical studies on high-pressure steam condensation phenomena in a steel containment vessel connected to a water cooling tank, carried out at Oregon State University (OrSU) and the University of Wisconsin at Madison (UW-Madison). The experimental results are employed to validate the containment condensation model in reactor containment system safety analysis code for integral SMRs. Such a containment condensation model is important to demonstrate the adequate cooling. In the three years of investigation, following the original proposal, the following planned tasks have been completed: (1) Performed a scaling study for the full pressure test facility applicable to the reference design for the condensation heat transfer process during design basis accidents (DBAs), modified the existing test facility to route the steady-state secondary steam flow into the high pressure containment for controllable condensation tests, and extended the operations at negative gage pressure conditions (OrSU). (2) Conducted a series of DBA and quasi-steady experiments using the full pressure test facility to provide a reliable high pressure condensation database (OrSU). (3) Analyzed experimental data and evaluated condensation model for the experimental conditions, and predicted the prototypic containment performance under accidental conditions (UW-Madison). The results are applicable to integral Small Modular Reactor (SMR) designs, including NuScale, mPower, Westinghouse SMR, Holtec-160 and other integral reactors with small containments of relatively high pressures under accidental conditions. Testing has been conducted at the OrSU laboratory in the existing MASLWR (Multi-Application Small Light Water Reactor) integral test facility sponsored by the US Department of Energy. Its highpressure stainless steel containment model (~2 MPa) is scaled to the NuScale SMR currently under development at NuScale Power, Inc.. Minor modifications to the model containment have been made to control the non-condensable gas fraction and to utilize the secondary loop stable steam flow for condensation testing. UW-Madison has developed a containment condensation model, which leveraged previous validated containment heat transfer work carried out at UW-Madison, and extended the range of applicability of the model to integral SMR designs that utilize containment vessels of high heat transfer efficiencies. In this final report, the research background and literature survey are presented in Chapter 2 and 3, respectively. The test facility description and modifications are summarized in Chapter 4, and the scaling analysis is introduced in Chapter 5. The tests description, procedures, and data analysis are presented in Chapter 6, while the numerical modeling is presented in Chapter 7, followed by a conclusion section in Chapter 8.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Investigation of Thermolytic Hydrogen Generation Rate in Tank 44 Dissolved Saltcake Samples

Saltcake core samples collected from Tank 44 in 2006 were dissolved to provide material for HGR measurements applicable to F-Area dissolved saltcake material. Additionally, characterization was performed on the Tank 44 saltcake material. The following are key results from the Tank 44 saltcake characterization. The Tank 44 Upper Saltcake Composite, corresponding to the 171 to 285 inch tank level, contained by mass approximately 69% sodium nitrate, 11% sodium carbonate, 8% sodium nitrite, smaller amounts of other salts and components, and 9% unquantified (which includes water, water of hydration, oxygen/hydrogen content of oxides and hydroxides, and uncertainty). The Tank 44 Lower Saltcake Composite, corresponding to the 76 to 114 inch tank level, contained by mass approximately 49% sodium carbonate, 18% sodium nitrate, smaller amounts of other salts, at least 8% sludge, and 9% unquantified (see above). The dissolved saltcake contained free hydroxide less than quantifiable (<0.01 M) due to the limited quantity of material that could be removed from the Shielded Cells based on the sample radioactivity. Measurement by pH paper provided an approximate pH of 12. The following are key results from the Tank 44 HGR testing. During boiling at 106.7 °C, HGR for Tank 44 dissolved saltcake without added glycolate was 7.2×10 -8 ft 3 h -1 ga l-1 . During boiling at 106.9 °C, HGR for Tank 44 dissolved saltcake with 1000 mg/L of added glycolate was 8.2×10 -8 ft 3 h -1 gal -1 . ∙ For the test without added glycolate, the first several HGR measurements at 70, 85, and 100 °C gave indication of the release of dissolved hydrogen and should not be used to represent the sustained thermolytic HGR for those temperatures. The measurements at boiling are the best representation of thermolysis in this testing. Carbon dioxide was observed at concentrations up to 6 vol% in the flow-system offgas for the test at boiling. ∙ Methane generation was observed at 100 °C and boiling. Methane concentration in the total gas generated during testing remained well below the lower flammability limit for methane in air. The addition of 1000 mg/L of glycolate did not have a significant impact on the hydrogen generation rates measured during this testing. The low hydroxide concentration in the Tank 44 dissolved saltcake likely influenced the relatively low thermolytic HGR and high carbon dioxide release observations in this testing. Based on the observation that methane was generated or released upon heating SRS radioactive Tank 44 waste samples to 100 °C and above, we recommend gaining a greater understanding of the cause and mechanism of its generation. First, the applicable literature should be reviewed to reveal the thermolytic methane generation mechanisms of possible methane generating species in the SRS CSTF. If warranted, a plan should be developed for simulant tests with methylated siloxanes and other applicable compounds in order to gain a better mechanistic understanding of methane generation in the SRS CSTF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of Thermolytic Hydrogen Generation Rate in Tank 44 Dissolved Saltcake Samples

Saltcake core samples collected from Tank 44 in 2006 were dissolved to provide material for HGR measurements applicable to F-Area dissolved saltcake material. Additionally, characterization was performed on the Tank 44 saltcake material. The following are key results from the Tank 44 saltcake characterization. The Tank 44 Upper Saltcake Composite, corresponding to the 171 to 285 inch tank level, contained by mass approximately 69% sodium nitrate, 11% sodium carbonate, 8% sodium nitrite, smaller amounts of other salts and components, and 9% unquantified (which includes water, water of hydration, oxygen/hydrogen content of oxides and hydroxides, and uncertainty). The Tank 44 Lower Saltcake Composite, corresponding to the 76 to 114 inch tank level, contained by mass approximately 49% sodium carbonate, 18% sodium nitrate, smaller amounts of other salts, at least 8% sludge, and 9% unquantified (see above). The dissolved saltcake contained free hydroxide less than quantifiable (<0.01 M) due to the limited quantity of material that could be removed from the Shielded Cells based on the sample radioactivity. Measurement by pH paper provided an approximate pH of 12. The following are key results from the Tank 44 HGR testing. During boiling at 106.7 °C, HGR for Tank 44 dissolved saltcake without added glycolate was 7.2×10 -8 ft 3 h -1 gal -1 . During boiling at 106.9 °C, HGR for Tank 44 dissolved saltcake with 1000 mg/L of added glycolate was 8.2×10 -8 ft 3 h -1 gal -1 . For the test without added glycolate, the first several HGR measurements at 70, 85, and 100 °C gave indication of the release of dissolved hydrogen and should not be used to represent the sustained thermolytic HGR for those temperatures. The measurements at boiling are the best representation of thermolysis in this testing. Carbon dioxide was observed at concentrations up to 6 vol% in the flow-system offgas for the test at boiling. Methane generation was observed at 100 °C and boiling. Methane concentration in the total gas generated during testing remained well below the lower flammability limit for methane in air. The addition of 1000 mg/L of glycolate did not have a significant impact on the hydrogen generation rates measured during this testing. The low hydroxide concentration in the Tank 44 dissolved saltcake likely influenced the relatively low thermolytic HGR and high carbon dioxide release observations in this testing. Based on the observation that methane was generated or released upon heating SRS radioactive Tank 44 waste samples to 100 °C and above, we recommend gaining a greater understanding of the cause and mechanism of its generation. First, the applicable literature should be reviewed to reveal the thermolytic methane generation mechanisms of possible methane generating species in the SRS CSTF. If warranted, a plan should be developed for simulant tests with methylated siloxanes and other applicable compounds in order to gain a better mechanistic understanding of methane generation in the SRS CSTF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Review of the Serrated-Flow Phenomenon and Its Role in the Deformation Behavior of High-Entropy Alloys

High-entropy alloys (HEAs) are a novel class of alloys that have many desirable properties. The serrated flow that occurs in high-entropy alloys during mechanical deformation is an important phenomenon since it can lead to significant changes in the microstructure of the alloy. In this article, we review the recent findings on the serration behavior in a variety of high-entropy alloys. Relationships among the serrated flow behavior, composition, microstructure, and testing condition are explored. Importantly, the mechanical-testing type (compression/tension), testing temperature, applied strain rate, and serration type for certain high-entropy alloys are summarized. The literature reveals that the serrated flow can be affected by experimental conditions such as the strain rate and test temperature. Furthermore, this type of phenomenon has been successfully modeled and analyzed, using several different types of analytical methods, including the mean-field theory formalism and the complexity-analysis technique. Importantly, the results of the analyses show that the serrated flow in HEAs consists of complex dynamical behavior. It is anticipated that this review will provide some useful and clarifying information regarding the serrated-flow mechanisms in this material system. Finally, suggestions for future research directions in this field are proposed, such as the effects of irradiation, additives (such as C and Al), the presence of nanoparticles, and twinning on the serrated flow behavior in HEAs.

36 MATERIALS SCIENCE↗

Experimental and Computational Validation of a Novel Particle Flow Control Valve for CSP Systems

Particle-based Concentrated Solar Power (CSP) systems most often utilize the state-of-the art slide gate mechanism for particle flow control. The slide-gate was found to have a sensitivity of 0.354 g/s-mm, a measure of mass flow rate over actuation position [1]. Particle-based CSP developers have noted that the slide gate is conducive to particle lodging, leaking, and difficulty actuating under particle pressure as well as differential expansion of the gate from thermal cycling. The goal of this work is to design, develop and test a novel particle flow control device that can operate without any hindrance from these shortcomings.

14 SOLAR ENERGY↗

Continental Scale Hydrostratigraphy: Basin‐Scale Testing of Alternative Data‐Driven Approaches

Abstract Integrated hydrological modeling is an effective method for understanding interactions between parts of the hydrologic cycle, quantifying water resources, and furthering knowledge of hydrologic processes. However, these models are dependent on robust and accurate datasets that physically represent spatial characteristics as model inputs. This study evaluates multiple data‐driven approaches for estimating hydraulic conductivity and subsurface properties at the continental‐scale, constructed from existing subsurface dataset components. Each subsurface configuration represents upper (unconfined) hydrogeology, lower (confined) hydrogeology, and the presence of a vertical flow barrier. Configurations are tested in two large‐scale U.S. watersheds using an integrated model. Model results are compared to observed streamflow and steady state water table depth (WTD). We provide model results for a range of configurations and show that both WTD and surface water partitioning are important indicators of performance. We also show that geology data source, total subsurface depth, anisotropy, and inclusion of a vertical flow barrier are the most important considerations for subsurface configurations. While a range of configurations proved viable, we provide a recommended Selected National Configuration 1 km resolution subsurface dataset for use in distributed large‐and continental‐scale hydrologic modeling.

54 ENVIRONMENTAL SCIENCES↗