Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fibers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Axial residual stresses in boron fibers

The axial residual stress distribution as a function of radius was determined from the fiber surface to the core including the average residual stress in the core. Such measurements on boron on tungsten (B/W) fibers show that the residual stresses for 102, 142, 203, and 366 micron diameter fibers were similar, being compressive at the surface and changing monotonically to a region of tensile within the boron. At approximately 25 percent of the original radius, the stress reaches a maximum tensile stress of about 860 mn/sq.m and then decreases to a compressive stress near the tungsten boride core. Data were presented for 203 micron diameter B/W fibers that show annealing above 900 C reduces the residual stresses. A comparison between 102 micron diameter B/W and boron on carbon (b/C) shows that the residual stresses were similar in the outer regions of the fibers, but that large differences near and in the core were observed. The effects of these residual stresses on the fracture of boron fibers were discussed.

Behrendt, D. R.↗

Wide temperature range fiber optic cable: Cable design study

Factors considered in the design and fabrication of a single fiber optic cable intended for spacecraft applications in an environment of temperature extremes from -160 C to 125 C include: abrasion resistance, low temperature flexibility, small size, low weight, and overall temperature stability. Specific requirements were identified for fiber core and overall diameters, fiber loss and NA, and cable tensile load. The single fiber cable will be fabricated by using a chemical vapor step index fiber of .125 mm coated to .3 mm with RTV silicone and then extruded with a jacket of Teflon PFA to a diameter of .5 mm. Six yarns of 1420 denier unimpregnated Kevlar 49 with a helical lay of 1.3 inches will surround the jacketed fiber under an extrusion of PFA. The finished cable diameter will measure 1.8 mm, and the weight of one kilometer length will be approximately 4350grams.

Speed, E. U.↗

Mechanisms of boron fiber strengthening by thermal treatment

The fracture strain for boron on tungsten fibers was studied for improvement by heat treatment under vacuum or argon environments. The mechanical basis for this improvement is thermally-induced axial contraction of the entire fiber, whereby strength-controlling core flaws are compressed and fiber fracture strain increased by the value of the contraction strain. By highly sensitive measurements of fiber density and volume, the physical mechanism responsible for contraction under both environments was identified as boron atom diffusion out of the fiber sheath. The fiber contracts because the average volume of the resulting microvoid was determined to be only 0.26 plus or minus 0.09 the average atomic volume of the removed atom. The basic and practical implications of these results are discussed with particular emphasis on the theory, use, and limitations of heat-induced contraction as a simple cost-effective secondary processing method.

Dicarlo, J. A.↗

Carbon fiber behavior in an enclosed volume

Tests were performed to evaluate the behavior of single carbon fibers existing in an enclosed space such as a room of a building. Three general phenomena were explored: the concentration decay rate of a fiber-charged room, the degree of uniform mixing of fibers within a room, and the effects of fibers being redisseminated off deposition surfaces within a room. The results were required in understanding the ratio of total indoor fiber exposure to total outdoor fiber exposure, a quantity essential to risk analysis. Results indicate that decay rate is predictable within acceptable limits and that homogeneous mixing can always be assumed. Some factors of redissemination are identified and effects discussed.

Harvey, M. C.↗

Mechanisms of boron fiber strengthening by thermal treatment

The fracture strain for boron on tungsten fibers can be improved by heat treatment under vacuum or argon environments. The mechanical basis for this improvement is thermally-induced axial contraction of the entire fiber, whereby strength-controlling core flaws are compressed and fiber fracture strain increased by the value of the contraction strain. By highly sensitive measurements of fiber density and volume, the physical mechanisms responsible for contraction under both environments was identified as boron atom diffusion out of the fiber sheath. The fiber contracts because the average volume of the resulting microvoid was determined to be only 0.26 + or - 0.09 the average atomic volume of the removed atom. The basic and practical implications of these results are discussed with particular emphasis on the theory, use, and limitations of heat-induced contraction as a simple cost-effective secondary processing method.

Dicarlo, J. A.↗

Burning characteristics and fiber retention of graphite/resin matrix composites

Graphite fiber reinforced resin matrix composites were subjected to controlled burning conditions to determine their burning characteristics and fiber retention properties. Small samples were burned with a natural gas fired torch to study the effects of fiber orientation and structural flaws such as holes and slits that were machined into the laminates. Larger laminate samples were burned in a modified heat release rate calorimeter. Unidirectional epoxy/graphite and polyimide/graphite composites and boron powder filled samples of each of the two composite systems were burn tested. The composites were exposed to a thermal radiation of 5.3 Btu/sq ft-sec in air. Samples of each of the unfilled composite were decomposed anaerobically in the calorimeter. Weight loss data were recorded for burning and decomposition times up to thirty-five minutes. The effects of fiber orientation, flaws, and boron filler additives to the resins were evaluated. A high char forming polyimide resin was no more effective in retaining graphite fibers than a low char forming epoxy resin when burned in air. Boron powder additions to both the polyimide and the epoxy resins stabilized the chars and effectively controlled the fiber release.

Bowles, K. J.↗

Effects of carbon/graphite fiber contamination on high voltage electrical insulation

The contamination mechanics and resulting failure modes of high voltage electrical insulation due to carbon/graphite fibers were examined. The high voltage insulation vulnerability to carbon/graphite fiber induced failure was evaluated using a contamination system which consisted of a fiber chopper, dispersal chamber, a contamination chamber, and air ducts and suction blower. Tests were conducted to evaluate the effects of fiber length, weathering, and wetness on the insulator's resistance to carbon/graphite fibers. The ability of nuclear, fossil, and hydro power generating stations to maintain normal power generation when the surrounding environment is contaminated by an accidental carbon fiber release was investigated. The vulnerability assessment included only the power plant generating equipment and its associated controls, instrumentation, and auxiliary and support systems.

Garrity, T.↗

Evaluation of micron size carbon fibers released from burning graphite composites

Quantitative estimates were developed of micron carbon fibers released during the burning of graphite composites. Evidence was found of fibrillated particles which were the predominant source of the micron fiber data obtained from large pool fire tests. The fibrillation phenomena were attributed to fiber oxidation effects caused by the fire environment. Analysis of propane burn test records indicated that wind sources can cause considerable carbon fiber oxidation. Criteria estimates were determined for the number of micron carbon fibers released during an aircraft accident. An extreme case analysis indicated that the upper limit of the micron carbon fiber concentration level was only about half the permissible asbestos ceiling concentration level.

Sussholz, B.↗

Advanced risk assessment of the effects of graphite fibers on electronic and electric equipment

An assessment of the risk associated with accidents involving aircraft with carbon fiber composite structural components is examined. The individual fiber segments cause electrical and electronic equipment to fail under certain operating conditions. A Monte Carlo simulation model was used to computer the risk. Aircraft accidents with fire, release of carbon fiber material, entrainment of carbon fibers in a smoke plume transport of fibers downwind, transfer of some fibers/into the the interior of buildings, failures of electrical and electronic equipment, and economic impact of failures are discussed. Risk profiles were prepared for individual airports and the Nation. The vulnerability of electrical transmission equipment to carbon fiber incursion and aircraft accident total costs is investigated.

Pocinki, L.↗

Experimental and analytical studies for the NASA carbon fiber risk assessment

Various experimental and analytical studies performed for the NASA carbon fiber risk assessment program are described with emphasis on carbon fiber characteristics, sensitivity of electrical equipment and components to shorting or arcing by carbon fibers, attenuation effect of carbon fibers on aircraft landing aids, impact of carbon fibers on industrial facilities. A simple method of estimating damage from airborne carbon fibers is presented.

Source record↗

Risk to the public from carbon fibers released in civil aircraft accidents

Because carbon fibers are strong, stiff, and lightweight, they are attractive for use in composite structures. Because they also have high electrical conductivity, free carbon fibers settling on electrical conductors can cause malfunctions. If released from the composite by burning, the fibers may become a hazard to exposed electrical and electronic equipment. As part of a Federal study of the potential hazard associated with the use of carbon fibers, NASA assessed the public risk associated with crash fire accidents of civil aircraft. The NASA study projected a dramatic increase in the use of carbon composites in civil aircraft and developed technical data to support the risk assessment. Personal injury was found to be extremely unlikely. In 1993, the year chosen as a focus for the study, the expected annual cost of damage caused by released carbon fibers is only $1000. Even the worst-case carbon fiber incident simulated (costing $178,000 once in 34,000 years) was relatively low-cost compared with the usual air transport accident cost. On the basis of these observations, the NASA study concluded that exploitation of composites should continue, that additional protection of avionics is unnecessary, and that development of alternate materials specifically to overcome this problem is not justified.

Source record↗

Carbon fiber modification

The effect of several chemical treatments on the electrical and mechanical properties of carbon fibers was investigated with an optimum goal of increasing the electrical resistivity by a factor of 1000 without appreciably changing the mechanical properties. It was possible to effect resistivity increases from 10 to 50 percent without adversely affecting the tensile strength or Young's modulus for T-300 and C-6000 PAN fibers by treatments with either AlCl3 or nitric acid mixtures. Larger increases in the resistivity were produced with pitch fibers treated with nitric acid mixtures. This treatment also produced a partial decomposition of the pitch fiber and deterioration of the mechanical properties. The rationale behind the approch was to immobilize the conductivity producing pi electrons in the microscopic aromatic structure of the carbon fibers without destroying the strength producing sigma bonds. The investigations indicate that certain chemical treatments can produce such results, but the total reduction in the electrical conductivity which was achieved was not large enough to impact on problems which might arise from the high conductivities of the fibers.

Thompson, T. E.↗

Benzoic acid degradation of polyacrylonitrile fibers

The reactions of polyacrylonitrile (PAN) fibers in the presence of benzoic acid have been studied. Polyacrylonitrile fibers oxidize more readily in the presence of benzoic acid than in air at temperatures in the range of 170 C. The product decreased in solubility with extent of reaction. Gel permeation chromatography of the soluble fraction showed change in polydispersity. The insoluble product exhibited differences in weight loss as a function of decomposition temperature compared to PAN fibers. Infrared analyses of the fiber product showed absorption peaks similar to air-oxidized PAN. High-energy photoelectron spectral analysis showed a carbon-rich surface which contained oxygen and nitrogen. An air oxidized sample of fiber contained more oxygen at the surface than a fiber treated first with benzoic acid and then air oxidized.

Varma, D. S.↗

Benzoic acid degradation of polyacrylonitrile fibers

The reactions of polyacrylonitrile (PAN) fibers in the presence of benzoic acid have been studied. Polyacrylonitrile fibers oxidize more readily in the presence of benzoic acid than in air at temperatures in the range of 170 C. The product decreased in solubility with extent of reaction. Gel permeation chromatography of the soluble fraction showed change in polydispersity. The insoluble product exhibited differences in weight loss as a function of decomposition temperature compared to PAN fibers. Infrared analyses of the fiber product showed absorption peaks similar to air-oxidized PAN. High-energy photoelectron spectral analysis showed a carbon-rich surface which contained oxygen and nitrogen. An air oxidized sample of fiber contained more oxygen at the surface than a fiber treated first with benzoic acid and then air oxidized.

Varma, D. S.↗

Impact resistance of fiber composites

Stress-strain curves are obtained for a variety of glass fiber and carbon fiber reinforced plastics in dynamic tension, over the stress-strain range of 0.00087-2070/sec. The test method is of the one-bar block-to-bar type, using a rotating disk or a pendulum as the loading apparatus and yielding accurate stress-strain curves up to the breaking strain. In the case of glass fiber reinforced plastic, the tensile strength, strain to peak impact stress, total strain and total absorbed energy all increase significantly as the strain rate increases. By contrast, carbon fiber reinforced plastics show lower rates of increase with strain rate. It is recommended that hybrid composites incorporating the high strength and rigidity of carbon fiber reinforced plastic with the high impact absorption of glass fiber reinforced plastics be developed for use in structures subjected to impact loading.

Chamis, C. C.↗

SixNyCz Fibers for Safer Composites

Silicon nitride/silicon carbide fibers prepared by pyrolysis of polycarbosilazanes proposed substitute for carbon fibers. Silicon nitride/silicon carbide fibers tested pyrolyzed from polycarbosilazanes prepared from tris(N-methylamino) methylsilane. Polycarbosilazane resin drawn into fiber from melt, treated and pyrolyzed. Pyrolyzed fibers are shiny black. Tests show new fibers have physical properties comparable to graphite but with lower conductivity.

Ledbetter, F. E., III↗

Method of carbonizing polyacrylonitrile fibers

This invention relates to a method of carbonizing polyacrylonitrile fibers by exposing the fibers at an elevated temperature to an oxidizing atmosphere; then exposing the oxidized fibers to an atmosphere of an inert gas such as nitrogen containing a carbonaceous material such as acetylene. The fibers are preferably treated with an organic compound, for example benzoic acid, before the exposure to an oxidizing atmosphere. The invention also relates to the resulting fibers. The treated fibers have enhanced tensile strength.

Cagliostro, D. E.↗

Constant Fiber Number During Skeletal Muscle Atrophy and Modified Arachidonate Metabolism During Hypertrophy

A previously documented shift from Type I to IIA predominance of the soleus muscle during rat suspension was further investigated to determine if this shift was by selective reduction of a single fiber type, simultaneous reduction and formation of fibers with different fiber types, or a transformation of fiber type by individual fibers. By partial acid digestion and dissection, average total soleus fiber number was found to be 3022 + or - 80 (SE) and 3008 + or - 64 before and after four-week suspension (n=12). Another area of current research was based on previous studies which indicate that prostaglandins are biosynthesized by skeletal muscle and evoke protein synthesis and degradation.

Templeton, G.↗