Data and Analytics to Inform Energy Retrofit of High Performance Buildings

Buildings consume more than one-third of the world?s primary energy. Reducing energy use in buildings with energy efficient technologies is feasible and also driven by energy policies such as energy benchmarking, disclosure, rating, and labeling in both the developed and developing countries. Current energy retrofits focus on the existing building stocks, especially older buildings, but the growing number of new high performance buildings built around the world raises a question that how these buildings perform and whether there are retrofit opportunities to further reduce their energy use. This is a new and unique problem for the building industry. Traditional energy audit or analysis methods are inadequate to look deep into the energy use of the high performance buildings. This study aims to tackle this problem with a new holistic approach powered by building performance data and analytics. First, three types of measured data are introduced, including the time series energy use, building systems operating conditions, and indoor and outdoor environmental parameters. An energy data model based on the ISO Standard 12655 is used to represent the energy use in buildings in a three-level hierarchy. Secondly, a suite of analytics were proposed to analyze energy use and to identify retrofit measures for high performance buildings. The data-driven analytics are based on monitored data at short time intervals, and cover three levels of analysis ? energy profiling, benchmarking and diagnostics. Thirdly, the analytics were applied to a high performance building in California to analyze its energy use and identify retrofit opportunities, including: (1) analyzing patterns of major energy end-use categories at various time scales, (2) benchmarking the whole building total energy use as well as major end-uses against its peers, (3) benchmarking the power usage effectiveness for the data center, which is the largest electricity consumer in this building, and (4) diagnosing HVAC equipment using detailed time-series operating data. Finally, a few energy efficiency measures were identified for retrofit, and their energy savings were estimated to be 20percent of the whole-building electricity consumption. Based on the analyses, the building manager took a few steps to improve the operation of fans, chillers, and data centers, which will lead to actual energy savings. This study demonstrated that there are energy retrofit opportunities for high performance buildings and detailed measured building performance data and analytics can help identify and estimate energy savings and to inform the decision making during the retrofit process. Challenges of data collection and analytics were also discussed to shape best practice of retrofitting high performance buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the performance of global thermostat adjustment in commercial buildings for load shifting demand response

Abstract Efficiently leveraging new sources of flexibility is critical to mitigating load balancing challenges posed by variable renewable resources. The thermal inertia of commercial buildings allows us to shift their power consumption on minute to hourly timescales to provide demand response to the grid while maintaining occupant comfort. Global thermostat adjustment (GTA) provides a readily available and scalable approach for implementing load shifting demand response using commercial heating, ventilation, and air conditioning (HVAC) systems, since it leverages the inherent sophistication of modern building automation systems. However, there is an incomplete understanding of GTA’s performance for this purpose and its impact on building systems and occupant comfort. In this paper, we explore the performance of GTA by analyzing results from nearly nine hundred experiments on eight university campus buildings in Michigan and North Carolina. Using GTA, we manipulate each building’s thermostat setpoints causing the building to shift its power consumption with respect to its baseline. We quantify the magnitude of HVAC power response, energy use of HVAC subsystems, and impact on occupant comfort. Finally, we connect our experimental results with power system operation using an optimization model that coordinates GTA actions across a large collection of grid-interactive efficient buildings (GEBs) to reduce high ramp rates on the grid and mitigate renewable energy curtailment. Overall, our work finds that the impacts on HVAC subsystems are often complex, and may result in additional energy being consumed by fans and terminal reheat. These effects must be considered when using GTA for load shifting. Additionally, we demonstrate that occupant comfort, as assessed by indoor temperature and humidity, can be maintained during GTA events. From a societal perspective, our modeling work finds that the additional renewable energy that can be integrated through the use of GTA strategies eclipses any additional energy consumed by buildings.

Keskar, Aditya (ORCID:0000000244617980)↗

Measurement Methods to Determine Air Leakage Between Adjacent Zones

Air leakage between adjacent zones of a building can lead to indoor air quality and energy efficiency concerns, however there is no existing standard for measuring inter-zonal leakage. In this study, synthesized data and field measurements are analyzed in order to explore the uncertainty associated with different methods for collecting and analyzing fan pressurization measurements to calculate interzone leakage.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Acoustic and aerodynamic testing of a scale model variable pitch fan

A fully reversible pitch scale model fan with variable pitch rotor blades was tested to determine its aerodynamic and acoustic characteristics. The single-stage fan has a design tip speed of 1160 ft/sec (353.568 m/sec) at a bypass pressure ratio of 1.5. Three operating lines were investigated. Test results show that the blade pitch for minimum noise also resulted in the highest efficiency for all three operating lines at all thrust levels. The minimum perceived noise on a 200-ft (60.96 m) sideline was obtained with the nominal nozzle. At 44% of takeoff thrust, the PNL reduction between blade pitch and minimum noise blade pitch is 1.8 PNdB for the nominal nozzle and decreases with increasing thrust. The small nozzle (6% undersized) has the highest efficiency at all part thrust conditions for the minimum noise blade pitch setting; although, the noise is about 1.0 PNdB higher for the small nozzle at the minimum noise blade pitch position.

Jutras, R. R.↗

Static, noise, and transition tests of a combined-surface-blowing V/STOL lift/propulsion system

Efficient thrust vectoring and high levels of circulatory lift were obtained in tests of a half model V/STOL airplane by using a type of externally blown jet flap in which the jet exhaust from wing-mounted cruise fans is directed over both upper and lower surfaces of a flapped wing. Approximately 90% thrust recovery with 87 deg of thrust vectoring was achieved under static conditions using 89 deg of trailing edge flap deflection. The approximately 10% loss appears to be associated primarily with pressure losses due to the flap brackets or slot entries. The jet induced lift was shown to be 55% of the theoretical value for a fullspan jet-flapped wing, even though only 27.5% of the wingspan was immersed in the jet. Steady rate of descent capability in excess of 1,000 feet per minute is predicted. The possibility of significant aerodynamic-noise cancelling when blowing over both surfaces at high velocities is indicated.

Schoen, A. H.↗

Study of blade aspect ratio on a compressor front stage aerodynamic and mechanical design report

A single stage compressor was designed with the intent of demonstrating that, for a tip speed and hub-tip ratio typical of an advanced core compressor front stage, the use of low aspect ratio can permit high levels of blade loading to be achieved at an acceptable level of efficiency. The design pressure ratio is 1.8 at an adiabatic efficiency of 88.5 percent. Both rotor and stator have multiple-circular-arc airfoil sections. Variable IGV and stator vanes permit low speed matching adjustments. The design incorporates an inlet duct representative of an engine transition duct between fan and high pressure compressor.

Burger, G. D.↗

Effect of Resonator Axis Skew on Normal Incidence Impedance

High by-pass turbofan engines have fewer fan blades and lower rotation speeds than their predecessors. Consequently, the noise suppression at the low frequency end of the noise spectra has become an increasing concern. This has led to a renewed emphasis on improving noise suppression efficiency of passive, duct liner treatments at the lower frequencies. For a variety of reasons, passive liners are comprised of locally-reacting, resonant absorbers. One reason for this design choice is to satisfy operational and economic requirements. The simplest liner design consists of a single layer of honeycomb core sandwiched between a porous facesheet and an impervious backing plate. These resonant absorbing structures are integrated into the nacelle wall and are very ef- ficient over a limited bandwidth centered on their resonance frequency. Increased noise suppression bandwidth and greater suppression at lower frequencies is typically achieved for conventional liners by increasing the liner depth and incorporating thin porous septa into the honeycomb core. However, constraints on liner depth in modern high by-pass engine nacelles severely limit the suppression bandwidth extension to lower frequencies. Also, current honeycomb core liners may not be suitable for irregular geometric volumes heretofore not considered. It is of interest, therefore, to find ways to circumvent liner depth restrictions and resonator cavity shape constraints. One way to increase effective liner depth is to skew the honeycomb core axis relative to the porous facesheet surface. Other possibilities are to alter resonator cavity shape, e.g. high aspect ratio, narrow channels that possibly include right angle bends, 180. channel fold-backs, and splayed channel walls to conform to irregular geometric constraints. These possibilities constitute the practical motivation for expanding impedance modeling capability to include unconventional resonator orientations and shapes. The work reported in this paper is in the nature of a progress report and is limited to examining the implications of resonator axis skew on the composite normal incidence impedance of an array of resonator channels. Specifically, experimental results are compared with a modified impedance prediction model for highaspect- ratio, rectangular, resonator channels with varying amounts of skew relative to the incident particle velocity. It is shown that for resonator channel widths of 1 to 2 mm, aspect ratios of 25 to 50, and skew angles of zero to sixty degrees, the surface impedance of test models can be predicted with good accuracy. Predicted resistances and reactances are particularly well correlated through the first resonance and first anti-resonance for all six test models investigated. Beyond the first anti-resonance, the impedance prediction model loses the ability to predict details of resistance and reactance but still predicts the mean trends very well.

Parrott, Tony L.↗

Unidirectional Sidechain Engineering to Construct Dual‐Asymmetric Acceptors for 19.23 % Efficiency Organic Solar Cells with Low Energy Loss and Efficient Charge Transfer

Abstract Achieving both high open‐circuit voltage ( V oc ) and short‐circuit current density ( J sc ) to boost power‐conversion efficiency (PCE) is a major challenge for organic solar cells (OSCs), wherein high energy loss ( E loss ) and inefficient charge transfer usually take place. Here, three new Y‐series acceptors of mono‐asymmetric asy‐YC11 and dual‐asymmetric bi‐asy‐YC9 and bi‐asy‐YC12 are developed. They share the same asymmetric D 1 AD 2 (D 1 =thieno[3,2‐ b ]thiophene and D 2 =selenopheno[3,2‐ b ]thiophene) fused‐core but have different unidirectional sidechain on D 1 side, allowing fine‐tuned molecular properties, such as intermolecular interaction, packing pattern, and crystallinity. Among the binary blends, the PM6 : bi‐asy‐YC12 one has better morphology with appropriate phase separation and higher order packing than the PM6 : asy‐YC9 and PM6 : bi‐asy‐YC11 ones. Therefore, the PM6 : bi‐asy‐YC12‐based OSCs offer a higher PCE of 17.16 % with both high V oc and J sc , due to the reduced E loss and efficient charge transfer properties. Inspired by the high V oc and strong NIR‐absorption, bi‐asy‐YC12 is introduced into efficient binary PM6 : L8‐BO to construct ternary OSCs. Thanks to the broadened absorption, optimized morphology, and furtherly minimized E loss , the PM6 : L8‐BO : bi‐asy‐YC12‐based OSCs achieve a champion PCE of 19.23 %, which is one of the highest efficiencies among these annealing‐free devices. Our developed unidirectional sidechain engineering for constructing bi‐asymmetric Y‐series acceptors provides an approach to boost PCE of OSCs.

Chemistry↗

Quantifying inactive lithium in lithium metal batteries

Lithium metal anodes offer high theoretical capacities (3,860 milliampere-hours per gram)1, but rechargeable batteries built with such anodes suffer from dendrite growth and low Coulombic efficiency (the ratio of charge output to charge input), preventing their commercial adoption. The formation of inactive (‘dead’) lithium— which consists of both (electro)chemically formed Li + compounds in the solid electrolyte interphase and electrically isolated unreacted metallic Li 0 —causes capacity loss and safety hazards. Quantitatively distinguishing between Li + in components of the solid electrolyte interphase and unreacted metallic Li 0 has not been possible, owing to the lack of effective diagnostic tools. Optical microscopy, in situ environmental transmission electron microscopy, X-ray microtomography and magnetic resonance imaging provide a morphological perspective with little chemical information. Nuclear magnetic resonance, X-ray photoelectron spectroscopy and cryogenic transmission electron microscopy can distinguish between Li + in the solid electrolyte interphase and metallic Li 0 , but their detection ranges are limited to surfaces or local regions. Here we establish the analytical method of titration gas chromatography to quantify the contribution of unreacted metallic Li 0 to the total amount of inactive lithium. We identify the unreacted metallic Li 0 , not the (electro)chemically formed Li + in the solid electrolyte interphase, as the dominant source of inactive lithium and capacity loss. By coupling the unreacted metallic Li 0 content to observations of its local microstructure and nanostructure by cryogenic electron microscopy (both scanning and transmission), we also establish the formation mechanism of inactive lithium in different types of electrolytes and determine the underlying cause of low Coulombic efficiency in plating and stripping (the charge and discharge processes, respectively, in a full cell) of lithium metal anodes. Here we propose strategies for making lithium plating and stripping more efficient so that lithium metal anodes can be used for next-generation high-energy batteries.

25 ENERGY STORAGE↗

Hybrid Entanglement Distribution between Remote Microwave Quantum Computers Empowered by Machine Learning

Superconducting microwave circuits with Josephson junctions, the major platform for quantum computing, can only reach the full capability when connected. This requires an efficient protocol to distribute microwave entanglement. While quantum computers typically use discrete-variable (DV) methods for information encoding, the entire continuous-variable (CV) degree of freedom in electromagnetic fields must be utilized to achieve the highest entanglement distribution rate. Here, we propose a hybrid protocol to resolve the incompatibility between DV microwave quantum computers and CV quantum communications. CV microwave entanglement is distributed using optical swapping of optical-microwave entanglement pairs. To interface with DV microwave quantum computers, we further design a hybrid circuit to simultaneously convert and distill high-quality DV entanglement from noisy CV entanglement. The hybrid circuit is trained with machine-learning algorithms, ensuring high entanglement fidelity and generation rate. In conclusion, our work not only provides a practical method to realize efficient quantum links for superconducting microwave quantum computers, but also opens avenues to bridge the gap between DV and CV quantum systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energy Systems Training Programs and Certifications Survey White Paper

Compressed air system, industrial refrigeration system, chilled water system, pump system, fan system, steam system, process heating system, and combined heat and power system are the major industrial energy systems. By helping enhance knowledge and skills of workforce, training and certification programs on these systems are essential to improve energy efficiency of manufacturing facilities. A literature survey of currently available training and certification programs on these systems was conducted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Particle Acceleration during Magnetic Reconnection in a Low-beta Plasma

Magnetic reconnection is a primary mechanism for particle energization in space and astrophysical plasmas. By carrying out two-dimensional (2D) fully kinetic simulations, we study particle acceleration during magnetic reconnection in plasmas with different plasma β (the ratio between the thermal pressure and the magnetic pressure). For the high-β cases, we do not observe significant particle acceleration. In the low-β regime (β<0.1), we find that reconnection is efficient at energizing both electrons and ions. While the distribution of accelerated particles integrated over the whole simulation box appears highly non-thermal, it is actually the superposition of a series of distributions in different sectors of a 2D magnetic island. Each of those distributions has only a small non-thermal component compared with its thermal core. By tracking a large number of particles, we show that particles get energized in X-line regions, contracting magnetic islands, and magnetic island coalescence regions. We obtain the particle energization rate j⋅E by averaging over particle drift motions and find that it agrees well with the particle kinetic energy change. We quantify the contribution of curvature drift, gradient drift, polarization drift, magnetization, non-gyrotropic effect, and parallel electric field in different acceleration regions. We find that the major energization is due to particle curvature drift along the motional electric field. The other particle motions contribute less but may become important in different acceleration regions. The highly efficient particle energization in low-β plasmas may help us understand the strong particle energization in solar flares and accretion disk coronae.

79 ASTRONOMY AND ASTROPHYSICS↗

Cold-air investigation of a 31/2-stage fan-drive turbine with a stage loading factor of 4 designed for an integral lift engine. 2: Performance of 2-, 3- and 3 1/2-stage configurations

The stage work distribution among the three stages was very close to the design value. The specific work output-mass flow characteristics of the three stages were closely matched. The efficiency of the 3 1/2 stage turbine at design specific work output and design speed was within 0.008 of the estimated value, and this agreement was felt to demonstrate the adequacy of the prediction method in the high stage loading factor regime.

Whitney, W. J.↗

Comparison of Elekta VMAT with helical tomotherapy and fixed field IMRT: Plan quality, delivery efficiency and accuracy

Purpose: Helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT) are arc-based approaches to IMRT delivery. The objective of this study is to compare VMAT to both HT and fixed field IMRT in terms of plan quality, delivery efficiency, and accuracy. Methods: Eighteen cases including six prostate, six head-and-neck, and six lung cases were selected for this study. IMRT plans were developed using direct machine parameter optimization in the Pinnacle{sup 3} treatment planning system. HT plans were developed using a Hi-Art II planning station. VMAT plans were generated using both the Pinnacle{sup 3} SmartArc IMRT module and a home-grown arc sequencing algorithm. VMAT and HT plans were delivered using Elekta's PreciseBeam VMAT linac control system (Elekta AB, Stockholm, Sweden) and a TomoTherapy Hi-Art II system (TomoTherapy Inc., Madison, WI), respectively. Treatment plan quality assurance (QA) for VMAT was performed using the IBA MatriXX system while an ion chamber and films were used for HT plan QA. Results: The results demonstrate that both VMAT and HT are capable of providing more uniform target doses and improved normal tissue sparing as compared with fixed field IMRT. In terms of delivery efficiency, VMAT plan deliveries on average took 2.2 min for prostate and lung cases and 4.6 min for head-and-neck cases. These values increased to 4.7 and 7.0 min for HT plans. Conclusions: Both VMAT and HT plans can be delivered accurately based on their own QA standards. Overall, VMAT was able to provide approximately a 40% reduction in treatment time while maintaining comparable plan quality to that of HT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A long-pulse repetitive operation magnetically insulated transmission line oscillator

The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact Testing and Analysis of Composites for Aircraft Engine Fan Cases

The fan case in a jet engine is a heavy structure because of its size and because of the requirement that it contain a blade released during engine operation. Composite materials offer the potential for reducing the weight of the case. Efficient design, test, and analysis methods are needed to efficiently evaluate the large number of potential composite materials and design concepts. The type of damage expected in a composite case under blade-out conditions was evaluated using a subscale test in which a glass/epoxy composite half-ring target was impacted with a wedge-shaped titanium projectile. Fiber shearing occurred near points of contact between the projectile and target. Delamination and tearing occurred on a larger scale. These damage modes were reproduced in a simpler test in which flat glass/epoxy composites were impacted with a blunt cylindrical projectile. A surface layer of ceramic eliminated fiber shear fracture but did not reduce delamination. Tests on 3D woven carbon/epoxy composites indicated that transverse reinforcement is effective in reducing delamination. A 91 cm (36 in.) diameter full-ring sub-component was proposed for larger scale testing of these and other composite concepts. Explicit, transient, finite element analyses indicated that a full-ring test is needed to simulate complete impact dynamics, but simpler tests using smaller ring sections are adequate when evaluation of initial impact damage is the primary concern.

Roberts, Gary D.↗

Quiet Cruise Efficient Short Take-off and Landing Subsonic Transport System

This NASA funded study conceived a revolutionary airplane concept to enable future traffic growth by using regional air space. This requires a very quiet airplane with STOL capability. Starting with a Blended Wing Body that is cruise efficient with inherent low noise characteristics from forward noise shielding and void of aft downward noise reflections, integration of embedded distributed propulsion enables incorporation of the revolutionary concept for jet noise shielding. Embedded distributed propulsion also enables incorporation of a fan bleed internally blown flap for quiet powered lift. The powered lift provides STOL capability for operation at regional airports with rapid take-off and descent to further reduce flyover noise. This study focused on configuring the total engine noise shielding STOL concept with a BWB airplane using the Boeing Phantom Works WingMOD multidisciplinary optimization code to define a planform that is pitch controllable. The configuration was then sized and mission data developed to enable NASA to assess the flyover and sideline noise. The foundational technologies needed are identified including military dual use benefits.

Kawai, Ron↗