Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Feedback-Based Fault-Tolerant and Health-Adaptive Optimal Charging of Batteries

The key technology barriers that hinder the growth of Electric Vehicles (EVs) are long charging time, the shorter life-time of EV batteries, and battery safety. Specifically, EV charging protocols have significant effects on battery lifetime and safety. If not charged properly, the battery could end up with shorter life, and more importantly, improper charging can cause battery faults leading to catastrophic failures. To overcome these barriers, we propose a closed-loop feedback based approach, that enables real-time optimal fast charging protocol adaptation to battery health and possess active diagnostic capabilities in the sense that, during charging, it detects real-time faults and takes corrective action to mitigate such fault effects. We utilize battery electrical-thermal model, explicit battery capacity and power fade aging models, and thermal fault model to capture battery behavior. In conjunction with the models, we adopt linear quadratic optimal control techniques to realize the feedback-based control algorithm. Simulation studies are presented to illustrate the effectiveness of the proposed scheme.

batteries↗

Impact of anisotropy on TRISO fuel performance

Manufacturing of tristructural isotropic (TRISO) particles involves the deposition of pyrolytic carbon (PyC) and silicon carbide (SiC) layers using the fluidized bed chemical vapor deposition (CVD) process. The CVD process is known to generate polycrystalline layers with crystallographic textures, which imparts anisotropic thermophysical properties to the layers. Past studies have shown the risk for particle failure increases with an increase in anisotropy. The limit beyond which the anisotropy of PyC layers becomes unacceptable due to failure risk has been identified as a high-priority knowledge gap. This work presents a first systematic study on the effects of anisotropic thermal and mechanical properties on TRISO fuel performance. This computational study, performed using the fuel performance code BISON, investigates how the anisotropy in elasticity and thermal properties affect the stresses, temperature, and failure of a TRISO particle. The influence of other factors, such as operating temperature and particle geometry on the anisotropy effects, also has been analyzed. The studies utilize the recently published anisotropic elasticity and thermal behavior models for TRISO PyC and SiC layers implemented using tensors with full anisotropic capability. The spherical TRISO particles with anisotropic properties were found to have greater maximum tensile stress and significantly higher failure probability than the spherical particles with isotropic properties. In conclusion, the fuel performance predicted using these recently developed models was found to be comparable with the performance obtained using the historical models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Distribution of blackouts in the power grid and the Motter and Lai model

Carreras, Dobson, and colleagues have studied empirical data on the sizes of the blackouts in real grids and modeled them with computer simulations using the direct current approximation. They have found that the resulting blackout sizes are distributed as a power law and suggested that this is because the grids are driven to the self-organized critical state. In contrast, more recent studies found that the distribution of cascades is bimodal resulting in either a very small blackout or a very large blackout, engulfing a finite fraction of the system. Here we reconcile the two approaches and investigate how the distribution of the blackouts changes with model parameters, including the tolerance criteria and the dynamic rules of failure of the overloaded lines during the cascade. Finally, we study the same problem for the Motter and Lai model and find similar results, suggesting that the physical laws of flow on the network are not as important as network topology, overload conditions, and dynamic rules of failure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Multiphysics Modeling of Environmentally Assisted Brittle Fracture

Brittle materials, such as cement, compose major portions of built infrastructure and are vulnerable to degradation and fracture from chemo-mechanical effects. Currently, methods of modeling infrastructure do not account for the presence of a reactive environment, such as water, on the acceleration of failure. Here, we have developed methodologies and models of concrete and cement fracture that account for varying material properties, such as strength, shrinkage, and fracture toughness due to degradation or hydration. The models have been incorporated into peridynamics, non-local continuum mechanics methodology, that can model intersecting and branching brittle fracture that occurs in multicomponent brittle materials, such as concrete. Through development of new peridynamic capabilities, decalcification of cement and differential shrinkage in clay-cement composites have been evaluated, along with exemplar problems in nuclear waste cannisters and wellbores. We have developed methods to simulate multiphase phenomena in cement and cement-composite materials for energy and infrastructure applications.

36 MATERIALS SCIENCE↗

Software Development for Data Visualization and Analysis of PN-Diodes & MOSFET Devices

The U.S. Department of Energy has a broad mission to ensure the nation’s security by addressing ongoing environmental challenges, developing novel energy production technologies, and mitigating nuclear security concerns. These efforts benefit from developing more effective semiconductor materials and devices. The research discussed in this report aims to further the development of these new electronics by improving implementations of vertical device structures, which offer theoretically better performance compared to lateral structures. Specifically, it reviews the background and development of a new and easy-to-use program for data processing and analysis from experiments run on vertical gallium nitride power devices. Current vertical structures fall short in critical performance metrics, such as On-Resistance and Breakdown Voltage, due to poor management of the device’s electric field. Junction termination extensions, or JTEs, are a field management technique that increases a device’s resilience to expected failure modes by controlling its surface electric fields. Each JTE design requires significant experimental validation, consisting of hundreds of tested devices, each outputting an enormous set of data points. The new software includes multiple methods of filtering large sets of device testing data to identify and remove flawed devices, automate device analyses, and provide statistical breakdowns for four metrics used to define the effectiveness of the JTE and the current carrying capacity of the device. These results can then be related back to fabrication techniques and device design, and in the future, be combined with processing simulations to further improve our understanding of the JTE mechanisms.

97 MATHEMATICS AND COMPUTING↗

Processed Lab Data for Neural Network-Based Shear Stress Level Prediction

Machine learning can be used to predict fault properties such as shear stress, friction, and time to failure using continuous records of fault zone acoustic emissions. The files are extracted features and labels from lab data (experiment p4679). The features are extracted with a non-overlapping window from the original acoustic data. The first column is the time of the window. The second and third columns are the mean and the variance of the acoustic data in this window, respectively. The 4th-11th column is the the power spectrum density ranging from low to high frequency. And the last column is the corresponding label (shear stress level). The name of the file means which driving velocity the sequence is generated from. Data were generated from laboratory friction experiments conducted with a biaxial shear apparatus. Experiments were conducted in the double direct shear configuration in which two fault zones are sheared between three rigid forcing blocks. Our samples consisted of two 5-mm-thick layers of simulated fault gouge with a nominal contact area of 10 by 10 cm^2. Gouge material consisted of soda-lime glass beads with initial particle size between 105 and 149 micrometers. Prior to shearing, we impose a constant fault normal stress of 2 MPa using a servo-controlled load-feedback mechanism and allow the sample to compact. Once the sample has reached a constant layer thickness, the central block is driven down at constant rate of 10 micrometers per second. In tandem, we collect an AE signal continuously at 4 MHz from a piezoceramic sensor embedded in a steel forcing block about 22 mm from the gouge layer The data from this experiment can be used with the deep learning algorithm to train it for future fault property prediction.

15 GEOTHERMAL ENERGY↗

Thickness threshold study of polyaniline-based lightning strike protection coating for carbon/glass fiber reinforced polymer composites

Different polyaniline (PANI) based lightning strike protection (LSP) coating thicknesses were tested against simulated lightning strike tests to evaluate the threshold thickness of the coating. A series of lightning strike tests were performed on carbon/glass fiber reinforced polymer (CFRP/GFRP) composites subjected to simulated lightning currents ranging from 40 to 100 kA. Five LSP-coated specimens were considered herein: two CFRP and three GFRP composites. A minimum of ~ 345 μm thick PANI-based LSP coating on CFRP and GFRP composites under a 40 kA peak current retained 83 % and 100 % residual strength, respectively. Additionally, GFRP specimens tested against 60 and 100 kA peak currents exhibited 100 % residual strength. Finally, this study proposes that a PANI-based LSP coating is suitable for protecting GFRP composites, while the careful design is necessary for CFRP composites to avoid any catastrophic failure.

36 MATERIALS SCIENCE↗

Status Report on Fast Flux Test Facility Mechanistic Fuel Failure Experiment Analysis with BISON for Post Irradiation Examination Support

The renewed interest in metallic U-Zr nuclear fuel alloy has led to a drive for deeper understanding of the mechanisms driving the phenomena observed under irradiation conditions. The Department of Energy Advanced Fuel Campaign has developed infrastructure to support metallic fuel development, including Post Irradiation Examination (PIE) of legacy Fast Flux Test Facility (FFTF) Mechanistic Fuel Failure (MFF) experiments. The PIE performed on legacy FFTF MFF experiments gives insight on metallic fuel performance and can address the lack of knowledge and scarcity of reliable data identified in several studies over recent years. Unfortunately, PIE efforts can cost significant time and resources which can impede the progress of metallic U-Zr fuel development. Metallic U-Zr fuel performance modeling can be used to inform PIE efforts on regions of interest for relevant investigations and can help understand phenomena observed in PIE. This report demonstrates the current progress of FFTF MFF fuel performance simulations using the BISON fuel performance code and discusses the support provided by simulation to PIE efforts. Progress in temperature, profilometry, fission gas release, plenum pressure, and zirconium redistribution simulation results have been demonstrated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Distributed Automatic Generation Control Considering DPV Using T&D Dynamic Co-Simulation

The increasing adoption of distributed energy resources (DERs) over the last decade warrants a reconsideration of control of generation resources. This paper proposes a distributed Automatic Generation Control (AGC) using transmission-and-distribution (T&D) dynamic co-simulation framework for the efficient DPV frequency regulation services. The co-simulation framework allows AGC units to exchange the information for distributed AGC, based on their adopted communication network topology. As a result, a cost-effective automatic generation control is achieved with DPV and conventional generators. The proposed distributed AGC is based on the gossip algorithm in which the neighboring AGC units share the relevant local information with each other and updates their share of AGC regulation signal. Distributed photovoltaics (DPV) unit contribute to AGC response based on their headroom capacity via DER aggregators. The algorithm is tested on IEEE-14 bus transmission system under conditions of generation failure and random load variation to observe effective frequency regulations service offered by DPVs and other AGC units. The study shows that DPV can effectively participate in AGC with the proposed distributed control framework.

automatic generation control↗

Lightning Current Propagation in Electrical Conduit

Investigation of lightning strikes to conductors ran through long spans of rigid steel conduit was performed. An overdamped-exponential current waveform with controlled peaks and rise rates was used to inject simulated lightning strikes. The impact of the length of wire, length of conduit, grounding location/s, and load type was investigated. Breakdown of 600 V, 12 AWG, THHN insulated wire (3.23 mm OD, 2 mm conductor diameter) was observed for voltages above 45 kV. The presence of resistive loads (between wire and ground) in excess of 20 ohms, or current rise times in excess of 5 kA/μs were found to consistently produce breakdown between wire and conduit. Practical power circuit elements such as outlets and splices were found to breakdown at voltage levels much below the wire insulation failure threshold.

47 OTHER INSTRUMENTATION↗

Modeling Framework to Analyze Performance and Structural Reliability of Solid Oxide Electrolysis Cells

Solid oxide electrolysis cells (SOEC) have been receiving significant attention recently because of their high energy efficiency and fast hydrogen production. In this study a multi-physics model to simulate the SOEC performance and structural reliability of a state-of-the-art planar SOEC design was developed. The electrochemical reactions, fluid dynamics, species transport, electron transfer, and heat transfer were modeled in the commercial computational fluid dynamics (CFD) software STAR-CCM+. The thermomechanical analysis and the associated structural reliability evaluations were conducted using the commercial finite element analysis software ANSYS. The electrochemistry model was validated by using the experimentally obtained current-voltage (I-V) characteristics of the electrode-supported SOECs. The reliability analysis using a risk-of-rupture approach showed low failure probabilities under standard operating conditions considered in this study. For cells operated at voltages well above a thermoneutral voltage, the reliability evaluations indicated a potential risk of cell failure, but the damage was concentrated locally in specific areas of the cell which typically do not lead to total loss of cell function. The presented approach provides insights for evaluating representative cell and stack performances and structural reliability without intensive testing and for developing optimally performing and structurally reliable SOECs for efficient hydrogen generation.

25 ENERGY STORAGE↗

Artificial Intelligence Thermostat to Detect Faults

Residential air conditioners and heat pumps often experience faults due to inadequate maintenance, which can severely reduce efficiency or even cause system failure. Common issues include dirty or clogged air filters and refrigerant leaks. These problems degrade performance and increase energy use and operating costs. This study presents a smart thermostat with embedded artificial intelligence to detect such faults and alert homeowners when maintenance is needed. The thermostat uses low-cost measurements—including return-air temperature, relative humidity, supply-air temperature, outdoor-air temperature, and condenser subcooling—to identify abnormal operations. Because different faults produce distinct response patterns, tailored algorithms are developed to recognize characteristic fault signatures. The investigation is built on a detailed co-simulation platform that couples EnergyPlus with the DOE/ORNL Heat Pump Design Model (HPDM). EnergyPlus represents the building’s dynamic environment, while HPDM is a high-fidelity, hardware-based model that can simulate fault-free performance as well as a wide range of faults, including gradual degradation such as minor refrigerant leakage. This platform provides a virtual training and testing environment that helps distinguish fault-induced behavior from normal operation and supports development of robust diagnostic algorithms. Using this framework, a Dynamic Bayesian Network was developed to identify two common faults—gradual refrigerant charge loss and indoor airflow blockage—and the AI-embedded thermostat was verified through annual building simulations.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scaling for Nuclear Reactor System: Overview

A scaling analysis is essential for predicting the behavior of a reactor system under various operating conditions, as well as for ensuring safe and reliable experimentation and adequate dataset generation for supporting the system code model development and assessment in accordance with USNRC guidelines 1.203. Testing and modeling can be carried out at various scales, from small test units to full-scale reactors, to validate the predictions produced by the analysis. However, due to the cost and challenges associated with full-scale testing, the nuclear industry uses scaled test facilities—integral effect test (IET) and separate effect test (SET)—to identify potential design issues and optimize the design to ensure regulatory compliance for safer operation and anticipated accident management. In general, IET facilities are non-nuclear thermal hydraulics test facilities. In contrast, SET facilities can be non-nuclear testing (e.g., steam generator, containment, pump system SETs) and nuclear testing (mostly fuel-material irradiation testing). IETs are used to study the system-level thermal-hydraulic behavior of the reactor coolant system (RCS) under different anticipated operational occurrences (AOOs) and design basis accidents (DBAs) such as loss-of-coolant-accident (LOCA) and loss-of-power (i.e., station blackout) and loss-of-flow (i.e., failure of RCS pump). Several LOCA scenarios could happen in reactor DBAs, such as main steam line break (MSLB), SG tube rapture (SGTR), break in direct vessel injection (DVI), and other small breaks LOCA. Scaling analysis determines the appropriate size and operating conditions for the test facility. This involves analyzing the system's thermal-hydraulic behavior at different scales and identifying the key parameters that affect the thermal-hydraulic behavior of the reactor. These key parameters can be identified so that the scaled facility can replicate the expected conditions in a prototypical setting. The scaled facility can simulate the same flow rates, pressure gradients, heat transfer coefficients, and fluid properties as the prototype. Scaling analysis is used to ensure that the results from these tests can be scaled up to predict the behavior of a full-scale prototype with an acceptable range of scaling distortions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Proof-of-Concept for Sensor Modeling in MOOSE for the Design of Autonomous Nuclear Reactor Control

Autonomous operation is essential for the deployment of microreactors and fission batteries, both in terrestrial and space applications. For this reason, recent studies have investigated autonomous control by using adaptive model predictive control and multi-objective optimization for heat pipe–cooled microreactors under normal and heat pipe failure conditions. However, prototypes of microreactors and fission batteries do not exist yet, and even the design space has not been narrowed down conclusively, making the instrumentation and control system design difficult. For this reason, there is a need for flexible computational capabilities to create a numerical stand-in of potential microreactor and fission battery designs. The latter can be used to design and test control strategies to support autonomous operations. In this poster, we describe the initial implementation of a pluggable sensor system for the easy implementation of realistic sensor models in the multiphysics object-oriented simulation environment (MOOSE) framework. This new capability will enable MOOSE users to create a numerical stand-in of microreactors and fission batteries, ultimately allowing them to easily test new control algorithms, and instrumentation strategies for advanced systems in the design phase.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of thickness on degradation of austenitic 347H steel by direct-fired supercritical CO 2 power cycle environment

Austenitic 347H steel of two thicknesses (2.54 and 0.6 mm) was exposed to a simulated direct-fired supercritical CO 2 (sCO 2 ) power cycle environment at 650°C and 1 atm for 1000 h then tensile stressed at room temperature to study the deformation behavior. The thicker 347H formed a protective chromia scale over most of the surface, which minimized carburization of the underlying steel and resulted in no change in mechanical performance. In stark contrast, the thinner 347H formed non-protective Fe-rich oxides over the entire surface, resulting in extensive carburization of the underlying steel. Finally, this led to increased strength but significantly reduced ductility, resulting in partially brittle failure

36 MATERIALS SCIENCE↗

Molecular insights into the structure-property relationships of 3D printed polyamide reverse-osmosis membrane for desalination

3D-printing is an emerging method for manufacturing polyamide (PA) reserve osmosis (RO) membranes for water treatment and desalination, which can precisely control membrane structural properties, such as thickness, roughness, and resolution. However, the synthesis-structure (i.e., degree of cross-linking (DC), m-phenylenediamine/trimesoyl chloride (MPD/TMC) ratio, and membrane thickness) to property (permeability and water-salt selectivity) relationships for these membranes has not been well understood. At the same time, a microscopic understanding of the physical mechanism of water and salt transport is needed to guide the design of high-performance 3D-printed membranes and improve the printing efficiency. Furthermore, the atomic-scale transport features and energetics of water and salt ions are studied at high pressure for the 3D-printed PA RO membranes with the different DCs and MPD/TMC ratios through non-equilibrium molecular dynamics (NEMD) simulations. Factoring in membrane structure properties, rejection ratio of salt ions and pressure-dependent water flux, 3D-printed PA membranes having an MPD/TMC ratio of 3.0:2.0 and a DC between 80%~90% attains ideal performance: high water flux, high rejection of salt ions, and excellent structural integrity. Mechanistically, water permeability for highly cross-linked PA RO membranes depends on the temporary on-and-off channels that allow water molecules to jump from one cavity to another at high pressure. In addition, higher pressures cause rapid compaction of PA membranes’ free volume and membrane thickness. Membrane failure at high pressure is determined by the DC and MPD/TMC ratios-dependent compressive yield strength. In short, these findings provide physical insights for optimizing existing PA membranes and designing next-generation desalination membranes at the molecular level.

3D-printed PA RO membrane↗

MARVEL Reactor Fuel Performance Report (Rev.2)

The Microreactor Applications Research Validation and EvaLuation (MARVEL) project is producing a high temperature liquid metal-cooled nuclear test bed at Idaho National Laboratory (INL) to ultimately improve the integration of microreactors to end-user applications. This ambitious effort seeks to design, authorize, construct, test, and operate the reactor within five years. In order to construct and operate the MARVEL reactor in a timely manner, the system will utilize materials and component designs which have already been used, qualified, or licensed from previous reactors. The MARVEL reactor will be located at the INL Transient Reactor Test (TREAT) facility in the north high-bay equipment pit and will use the existing 304 stainless steel-clad U-ZrH1.6 pin-type fuel system developed by General Atomics and purchased from TRIGA International. This fuel has been previously qualified under the United States Department of Energy’s (US DOE) Reduced Enrichment for Research and Test Reactors (RERTR) Program. Even though the regulator of the MARVEL reactor is the US DOE, the standards and overall approach recommended by the Nuclear Regulatory Commission is well-defined and utilized here. Following NUREG-1537 regulatory guidance, this report documents the authorization case for the MARVEL fuel system’s application to MARVEL and establishes stable and predictable fuel performance during the most thermophysically unfavorable conditions achievable in the MARVEL reactor. To that end, this report provides a comprehensive survey of the known thermophysical properties, performance, and quantitative relationships associated with the MARVEL reactor fuel element and uses this information to determine its mechanical integrity and risk of reaching unacceptable conditions during the most extreme accident scenarios predicted for the reactor using the most conservative assumptions available. The information contained herein is compiled from a combination of historical reports and peer reviewed scientific publication manuscripts. Known mechanisms under which the fuel is susceptible to failure are highlighted and compared to conditions that could exist in the MARVEL reactor during an unanticipated transient or accident scenario. The two scenarios considered for analysis in this report are (1) an unprotected loss of flow accident and (2) a hypothetical unprotected loss of coolant accident during the loss of flow accident. Preliminary 2D steady-state analyses herein indicate that both fuel-cladding chemical interactions and fuel-cladding mechanical interactions are negligible throughout the fuel’s operational cycle under both normal and high temperature accident scenario conditions. Although higher fidelity 3D time-dependent modeling and simulations are planned, the following may be concluded presently. The MARVEL fuel element maintains its geometric stability and structural integrity during the most extreme accident scenarios predicted for the MARVEL reactor. The hoop stress during the unprotected loss of flow accident reaches about -1.27 MPa; this negative stress indicates that it is compressive rather than tensile. The compressive stress is a result of the NaK pressure on the outside of the fuel element, caused by the restricted thermal expansion of the NaK coolant, exceeding the internal pressures generated inside of the fuel element. The hoop stress generated in the cladding during the unprotected loss of coolant accident reaches a maximum of about approximately 10 MPa, which is nearly an order of magnitude less than the predicted yield strength of the cladding under high-temperature accident scenario conditions. Calculations were compared with results from high performance computational simulations using BISON and are in very close agreement. A conservative MARVEL fuel meat peak temperature limit of 900 °C is recommended presently, which is about 180 °C higher than the peak fuel temperature predicted to occur during the most extreme accident. Based on the known properties and behavior of the MARVEL fuel element, the fuel successfully meets its design and safety requirements under normal and most extreme accident conditions with a large safety margin.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗