Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “exceptions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Reducing heat load density with asymmetric and inclined double-crystal monochromators: principles and requirements revisited

Asymmetric double-crystal monochromators (aDCMs) and inclined DCMs (iDCMs) can significantly expand the X-ray beam footprint and consequently reduce the heat load density and gradient. Based on rigorous dynamical theory calculations, the major principles and properties of aDCMs and iDCMs are presented to guide their design and development, particularly for fourth-generation synchrotrons. In addition to the large beam footprint, aDCMs have very large bandwidths (up to ∼10 eV) and angular acceptance, but the narrow angular acceptance of the second crystal requires precise control of the relative orientations and strains. Based on Fourier coupled-wave diffraction theory calculations, it is rigorously proved that the iDCM has almost the same properties as the conventional symmetric DCM, including the efficiency, angular acceptance, bandwidth, tuning energy range and sensitivity to misalignment. The exception is that, for the extremely inclined geometry that can achieve very large footprint expansion, the iDCM has (beneficially) a larger bandwidth and wider angular acceptance. Inclined diffraction has the `rho-kick effect' that can be cancelled by the second reflection of the iDCM (even with misalignment), except that inhomogeneous strains may cause non-uniform rho-kick angles. At present, fabrication/mounting-induced strains pose low risk since they can be controlled to <0.5 µrad over large areas. The only uncertain challenge is the thermally induced strains, yet it is estimated that these strains are naturally lowered by the large footprint and may be further mitigated by optimized cryogenic cooling to the 1–2 µrad level. Overall, aDCMs and iDCMs have more stringent requirements than normal DCMs, but they are feasible schemes in practice.

asymmetric monochromator↗

Distributed Workflows for Modeling Experimental Data

Modeling helps explain the fundamental physics hidden behind experimental data. In the case of material modeling, running one simulation rarely results in output that reproduces the experimental data. Often one or more of the force field parameters are not precisely known and must be optimized for the output to match that of the experiment. Since the simulations require high performance computing (HPC) resources and there are usually many simulations to run, a workflow is very useful to prevent errors and assure that the simulations are identical except for the parameters that need to be varied. These workflows are usually distributed because the simulations require HPC, but the optimization and steps to compare the simulation results and experimental data are done on a local workstation. We will present results from force field refinement of data collected at the Spallation Neutron Source using Kepler, Pegasus, and Beam workflows and discuss what we have learned from using these workflows.

Lynch, Vickie E.↗

A Novel State-Constrained Primary Control for Grid-Forming Inverters

The problem of operating an AC microgrid with purely inverter-based generating units is considered, and a novel vector control for the constrained grid-forming (GFM) inverters is proposed. The design aims to achieve the primary control objectives of the GFM inverters: voltage establishment, synchronization, and voltage/frequency regulation. It is novel that the proposed control also ensures all operational variables constrained both real-time and for all the time except for low voltage during the period of grid forming. The constraints include frequency, output AC voltage, input DC power, and active/reactive power injections to the grid. Here, in this paper, outcomes of a detailed simulation are presented to demonstrated that the above design objectives are met and that the overall performance is superior due to its unique ability of simultaneously controlling the whole vectors of the inverter state and output.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using Synchronization as an Indicator of Controllability in a Fleet of Water Heaters

Peak reduction is an important concern that can help reduce the growing stress on distribution grid and allow to defer investments in new capacity. However, the growing concern for customer privacy and comfort may impact the performance of load control for residential devices. Water heaters represent a convenient way of reducing peak due to their ability to store thermal energy for future use. In this paper, we developed a methodology to help utilities gain more insight with respect to the impact of load control efforts for shaving peak with no necessary information about the water heaters except the device status (on/off). To this end, we use a fleet of water heaters in a controlled residential neighborhood in Atlanta, GA. Our findings show that convergence in device status can serve as a proxy for peak shifting during hours of the evening peak.

demand response↗

Effects of cold stress on metabolic regulation in the overwintering larvae of the Chinese white pine beetle, Dendroctonus armandi

Abstract The Chinese white pine beetle, Dendroctonus armandi Tsai & Li (Coleoptera: Curculionidae, Scolytinae), is considered the most destructive forest pest in the Qinling and Bashan Mountains of China. In recent years, winter temperature has dropped in these regions, and extremely low temperatures are hard to survive for insects. Cold hardiness becomes a crucial strategy because temperature change often leads to fluctuations in insect abundance, and the metabolism rate is a key index of resistance to cold in overwintering insects. Therefore, we investigated the relationship between the change in respiratory rate and the activity of metabolism‐related mitochondrial enzymes in D. armandi larvae under cold conditions. We found that the respiratory rate decreased, and it was matched with the activity of glutamate dehydrogenase, aconitase, and lipase during overwintering. Among the various test times under cold conditions, the respiratory rate also decreased with decreasing temperature and increased under very low temperatures. At all cold stress periods, glutamate dehydrogenase and lipase showed increased activity at higher temperatures and decreased activity under lower temperatures, but the activity of NAD‐malic enzyme, NADP‐malic enzyme, mitochondrial isocitrate dehydrogenase, and aconitase were contrary. Under all low temperatures, the activity of enzymes – except for NADP‐malic enzyme, glutamate dehydrogenase, and lipase – increased in short‐term cold stress and decreased in long‐term cold stress at 4, 0, −4, −6, −8, and −10 °C. However, at −2 °C, the activity of enzymes showed a decreasing trend in short‐term treatments and an increasing trend in long‐term treatments, except for mitochondrial isocitrate dehydrogenase. The results not only improve our understanding of the metabolic mechanism of cold adaptation in D. armandi , but also provide an important experimental basis for further study and biological pest control.

Fu, Danyang↗

Change in terrestrial ecosystem water‐use efficiency over the last three decades

Abstract Defined as the ratio between gross primary productivity ( GPP ) and evapotranspiration ( ET ), ecosystem‐scale water‐use efficiency ( EWUE ) is an indicator of the adjustment of vegetation photosynthesis to water loss. The processes controlling EWUE are complex and reflect both a slow evolution of plants and plant communities as well as fast adjustments of ecosystem functioning to changes of limiting resources. In this study, we investigated EWUE trends from 1982 to 2008 using data‐driven models derived from satellite observations and process‐oriented carbon cycle models. Our findings suggest positive EWUE trends of 0.0056, 0.0007 and 0.0001 g C m −2 mm −1 yr −1 under the single effect of rising CO 2 (‘ CO 2 ’), climate change (‘ CLIM ’) and nitrogen deposition (‘ NDEP ’), respectively. Global patterns of EWUE trends under different scenarios suggest that (i) EWUE ‐ CO 2 shows global increases, (ii) EWUE ‐ CLIM increases in mainly high latitudes and decreases at middle and low latitudes, (iii) EWUE ‐ NDEP displays slight increasing trends except in west Siberia, eastern Europe, parts of North America and central Amazonia. The data‐driven MTE model, however, shows a slight decline of EWUE during the same period (−0.0005 g C m −2 mm −1 yr −1 ), which differs from process‐model (0.0064 g C m −2 mm −1 yr −1 ) simulations with all drivers taken into account. We attribute this discrepancy to the fact that the nonmodeled physiological effects of elevated CO 2 reducing stomatal conductance and transpiration ( TR ) in the MTE model. Partial correlation analysis between EWUE and climate drivers shows similar responses to climatic variables with the data‐driven model and the process‐oriented models across different ecosystems. Change in water‐use efficiency defined from transpiration‐based WUE t ( GPP / TR ) and inherent water‐use efficiency ( IWUE t , GPP × VPD / TR ) in response to rising CO 2 , climate change, and nitrogen deposition are also discussed. Our analyses will facilitate mechanistic understanding of the carbon–water interactions over terrestrial ecosystems under global change.

Huang, Mengtian↗

Leveraging observed soil heterotrophic respiration fluxes as a novel constraint on global-scale models

Microbially-explicit models may improve understanding and projections of carbon dynamics in response to future climate change, but their fidelity in simulating global-scale soil heterotrophic respiration (RH), a stringent test for soil biogeochemical models, has never been evaluated. We used statistical global RH products, as well as 7,821 daily site-scale RH measurements, to evaluate the spatio-temporal performance of one first-order decay model (CASA-CNP) and two microbially-explicit biogeochemical models (CORPSE and MIMICS) that were forced by two different climate datasets. CORPSE and MIMICS did not provide any measurable performance improvement; instead, the models were highly sensitive to the meteorological input data used to drive them. Spatial RH variability was generally well simulated except in the northern middle latitudes (~50°N) and arid regions; models captured the seasonal variability of RH well, but showed more divergence in tropic and arctic regions. Our results demonstrate that the next generation of biogeochemical models shows promise, but also needs to be improved for realistic spatio-temporal variability of RH. Finally, we emphasize the importance of net primary production, soil moisture, and soil temperature inputs, and that jointly evaluating soil models for their spatial (global scale) and temporal (site scale) performance provides crucial benchmarks for improving biogeochemical models.

Jian, Jinshi↗

Bioenergy crop models: Descriptions, data requirements and future challenges

Field studies that address the production of lignocellulosic biomass as a potential source of renewable energy are making available critical information for the development, validation, and use of bioenergy crop models. A literature survey revealed that 14 models have been developed and validated for herbaceous and woody bioenergy crops, and for Crassulacean acid metabolism (CAM) crops adapted to arid lands. These models simulate field-scale production of biomass for switchgrass (ALMANAC, EPIC, and Agro-BGC), miscanthus (MISCANFOR, MISCANMOD, and WIMOVAC), sugarcane (APSIM, AUSCANE, and CANEGRO), and poplar and willow (SECRETS and 3PG). Two models are adaptations of dynamic global vegetation models and simulate biomass yields of miscanthus and sugarcane as plant function types at regional scales (Agro-IBIS and LPJmL). A model of biomass production in CAM plants has been developed (EPI), but lacks the sophistication of the other models. Except for CAM plants, all the models include representations of leaf area dynamics, radiation interception and utilization, biomass production, and partitioning of biomass to roots and shoots. A few of the models are capable of simulating soil water, nutrient, and carbon cycle processes, making them especially useful for assessing environmental consequences (e.g., erosion and nutrient losses) associated with the field-scale deployment of bioenergy crops. Similar to other process-based models, simulations are challenged by computing and data management issues and an integrated framework for model testing and inter-comparison is needed. Considerable work remains concerning the development of models for unconventional bioenergy crops like CAM plants, generation and distribution of high-quality field data for model development and validation, and development of an integrated framework for efficient execution of large-scale simulations for use in planning regional to global sustainable bioenergy production systems.

Surendran Nair, Sujith↗

Effects of Al:Si and (Al+Na):Si Ratios on the Properties of the International Simple Glass, Part II: Structure

High-alumina containing high-level waste (HLW) will be vitrified at the Waste Treatment Plant at the Hanford Site. The resulting glasses, high in alumina, will have distinct composition-structure-property (C-S-P) relationships compared to previously studied HLW glasses. These C-S-P relationships determine the processability and product durability of glasses and therefore must be understood. The main purpose of this study is to understand the detailed structural changes caused by Al:Si and (Al+Na):Si substitutions in a simplified nuclear waste model glass (ISG, International Simple Glass) by combining experimental structural characterizations and molecular dynamics (MD) simulations. The structures of these two series of glasses were characterized by neutron total scattering and 27Al, 23Na, 29Si, and 11B solid-state nuclear magnetic resonance (NMR) spectroscopy. Additionally, MD simulations were used to generate atomistic structural models of the borosilicate glasses and simulation results were validated by the experimental structural data. Short-range (e.g., bond distance, coordination number, etc.) and medium-range (e.g., oxygen speciation, network connectivity, polyhedral linkages) structural features of the borosilicate glasses were systematically investigated as a function of the degree of substitution. The results show that bond distance and coordination number of the cation-oxygen pairs are relatively insensitive to Al:Si and (Al+Na):Si substitutions with the exception of the B-O pair. Additionally, the Al:Si substitution results in an increase of tri-bridging oxygen species, while (Al+Na):Si substitution creates non-bridging oxygen species. Charge compensator preferences were found for Si-[NBO] (Na+), [3]B-[NBO] (Na+), [4]B (mostly Ca2+), [4]Al (nearly equally split Na+ and Ca2+), and [6]Zr (mostly Ca2+). The network former-BO-network former linkages preferences were also tabulated; Si-O-Al and Al-O-Al were preferred at the expense of lower Si-O-[3]B and [3]B-O-[3]B linkages. These results provide insights on the structural origins of property changes such as glass transition temperature caused by the substitutions, providing a basis for future improvements of theoretical and computer simulation models.

Lu, Xiaonan↗

TiN coated aluminum electrodes for DC high voltage electron guns

Preparing electrodes made of metals like stainless steel, for use inside DC high voltage electron guns, is a labor-intensive and time-consuming process. In this paper, the authors report the exceptional high voltage performance of aluminum electrodes coated with hard titanium nitride (TiN). The aluminum electrodes were comparatively easy to manufacture and required only hours of mechanical polishing using silicon carbide paper, prior to coating with TiN by a commercial vendor. The high voltage performance of three TiN-coated aluminum electrodes, before and after gas conditioning with helium, was compared to that of bare aluminum electrodes, and electrodes manufactured from titanium alloy (Ti-6Al-4V). Following gas conditioning, each TiN-coated aluminum electrode reached −225 kV bias voltage while generating less than 100 pA of field emission (<10 pA) using a 40 mm cathode/anode gap, corresponding to field strength of 13.7 MV/m. Smaller gaps were studied to evaluate electrode performance at higher field strength with the best performing TiN-coated aluminum electrode reaching ∼22.5 MV/m with field emission less than 100 pA. These results were comparable to those obtained from our best-performing electrodes manufactured from stainless steel, titanium alloy and niobium, as reported in references cited below. The TiN coating provided a very smooth surface and with mechanical properties of the coating (hardness and modulus) superior to those of stainless steel, titanium-alloy, and niobium electrodes. These features likely contributed to the improved high voltage performance of the TiN-coated aluminum electrodes.

36 MATERIALS SCIENCE↗

Removing solar artifacts from Geostationary Lightning Mapper data to document lightning extremes

Here, we compare the performance of three different filters that identify solar artifacts in the Geostationary Lightning Mapper (GLM) data. These filters differ in their complexity and intended use. We use the most appropriate filters to document the severity of GLM solar contamination and to compute the frequency of extreme Americas lightning. Solar artifacts occur at an average rate of one every ~8 min. Due to their continuous emissions across a portion of the GLM CCD array, these events disproportionately contribute to the GLM event and group rates. Up to 40% of all events recorded between 10:00 and 12:00 local time during 2018 were solar artifacts. The frequency-domain solar filter also reveals a carrier wave at 50 to 60 Hz in some lightning flashes and solar episodes that appears to be anthropogenic in origin. Removing the relatively frequent solar artifact cases reveals rare cases of extreme lightning flashes. Exceptional flashes on the order of 500+ km in length and 10+ s in duration only occur a few times per year and are produced by storms that are predisposed for exceptional lightning rather than as single random occurrences.

54 ENVIRONMENTAL SCIENCES↗

Multifunctional light beam source for surface slope measuring long trace profilers

To fully exploit the advantages of fourth-generation synchrotron light sources, diffraction-limited-storage-rings (DLSR) and fully coherent free electron lasers (FELs), beamline mirrors and diffraction grating must be of exceptional quality. To achieve the required mirror and grating quality, the metrology instrumentation and methods used to characterize these challenging optics and, even more so, optical assemblies must also offer exceptional functionality and performance. One of the most widely used slope measuring instruments for characterizing x-ray optics is the long trace profiler (LTP). The easily reconfigurable mechanical design of the LTP allows optimization of the profiler arrangement to the specifics of a particular metrology task. Here, we discuss the optical schematic, design, and performance of an original multifunctional light beam source that provides functional flexibility of the LTP optical sensor. With this source, the LTP can be easily reconfigured for measurements of x-ray mirrors or diffraction gratings that have widely different source coherence requirements. Usage of a source with a low degree of coherence for mirror metrology helps to suppress the LTP systematic errors due to spurious interference effects in the LTP optical elements. A high-coherence narrow-band source is used for groove-density-distribution characterization of x-ray diffraction gratings. The systematic error and spatial resolution of the LTP with the different sources is also measured and analyzed.

Yashchuk, Valeriy V.↗

Large-area low-temperature ultrananocrystaline diamond (UNCD) films and integration with CMOS devices for monolithically integrated diamond MEMD/NEMS-CMOS systems.

Because of exceptional mechanical, chemical, and tribological properties, diamond has a great potential to be used as a material for the development of high-performance MEMS and NEMS such as resonators and switches compatible with harsh environments, which involve mechanical motion and intermittent contact. Integration of such MEMS/NEMS devices with complementary metal oxide semiconductor (CMOS) microelectronics will provide a unique platform for CMOS-driven commercial MEMS/NEMS. The main hurdle to achieve diamond-CMOS integration is the relatively high substrate temperatures (600-800 C) required for depositing conventional diamond thin films, which are well above the CMOS operating thermal budget (400 C). Additionally, a materials integration strategy has to be developed to enable diamond-CMOS integration. Ultrananocrystalline diamond (UNCD), a novel material developed in thin film form at Argonne, is currently the only microwave plasma chemical vapor deposition (MPCVD) grown diamond film that can be grown at 400 C, and still retain exceptional mechanical, chemical, and tribological properties comparable to that of single crystal diamond. We have developed a process based on MPCVD to synthesize UNCD films on up to 200 mm in diameter CMOS wafers, which will open new avenues for the fabrication of monolithically integrated CMOS-driven MEMS/NEMS based on UNCD. UNCD films were grown successfully on individual Si-based CMOS chips and on 200 mm CMOS wafers at 400 C in a MPCVD system, using Ar-rich/CH4 gas mixture. The CMOS devices on the wafers were characterized before and after UNCD deposition. All devices were performing to specifications with very small degradation after UNCD deposition and processing. A threshold voltage degradation in the range of 0.08-0.44V and transconductance degradation in the range of 1.5-9% were observed.

36 MATERIALS SCIENCE↗

Comparison of organ doses for patients undergoing balloon brachytherapy of the breast with HDR {sup 192}Ir or electronic sources using Monte Carlo simulations in a heterogeneous human phantom

Purpose: Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers. The radiation can be delivered using a conventional high-dose rate (HDR) {sup 192}Ir gamma-emitting source or a novel electronic brachytherapy (eBx) source which uses lower energy x rays that do not penetrate as far within the patient. A previous study [A. Dickler, M. C. Kirk, N. Seif, K. Griem, K. Dowlatshahi, D. Francescatti, and R. A. Abrams, ''A dosimetric comparison of MammoSite high-dose-rate brachytherapy and Xoft Axxent electronic brachytherapy,'' Brachytherapy 6, 164-168 (2007)] showed that the target dose is similar for HDR {sup 192}Ir and eBx. This study compares these sources based on the dose received by healthy organs and tissues away from the treatment site. Methods: A virtual patient with left breast cancer was represented by a whole-body, tissue-heterogeneous female voxel phantom. Monte Carlo methods were used to calculate the dose to healthy organs in a virtual patient undergoing balloon brachytherapy of the left breast with HDR {sup 192}Ir or eBx sources. The dose-volume histograms for a few organs which received large doses were also calculated. Additional simulations were performed with all tissues in the phantom defined as water to study the effect of tissue inhomogeneities. Results: For both HDR {sup 192}Ir and eBx, the largest mean organ doses were received by the ribs, thymus gland, left lung, heart, and sternum which were close to the brachytherapy source in the left breast. eBx yielded mean healthy organ doses that were more than a factor of {approx}1.4 smaller than for HDR {sup 192}Ir for all organs considered, except for the three closest ribs. Excluding these ribs, the average and median dose-reduction factors were {approx}28 and {approx}11, respectively. The volume distribution of doses in nearby soft tissue organs that were outside the PTV were also improved with eBx. However, the maximum dose to the closest rib with the eBx source was 5.4 times greater than that of the HDR {sup 192}Ir source. The ratio of tissue-to-water maximum rib dose for the eBx source was {approx}5. Conclusions: The results of this study indicate that eBx may offer lower toxicity to most healthy tissues, except nearby bone. TG-43 methods have a tendency to underestimate dose to bone, especially the ribs. Clinical studies evaluating the negative health effects caused by irradiating healthy organs are needed so that physicians can better understand when HDR {sup 192}Ir or eBx might best benefit a patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of an a-Si EPID in direct detection configuration as a water-equivalent dosimeter for transit dosimetry

Purpose: A major problem associated with amorphous silicon (a-Si) electronic portal imaging devices (EPIDs) for transit dosimetry is the presence of a phosphor layer, which can introduce large deviations from water-equivalent behavior due to energy-dependent response and visible light scattering. In this study, an amorphous silicon EPID was modified to a direct detection configuration by removing the phosphor layer, and the accuracy of using it for transit dosimetry measurements was investigated for 6 and 18 MV treatment beams by comparison to ion-chamber in water measurements. Methods: Solid water and copper were both evaluated as buildup materials. Using the optimum buildup thickness in each case, effects of changes in radiation field size, source to detector distance, and patient/phantom thickness were investigated by comparison to reference measurements made by an ionization chamber on the central axis. The off-axis response of the imager was also investigated by comparison of EPID image profiles to dose profiles obtained by a scanning ionization chamber in a water tank with various thicknesses of slab phantoms, and an anthropomorphic phantom in the beam using Gamma evaluation (3%, 3 mm criteria). The imaging characteristics of the direct EPID were investigated by comparison to a commercial EPID using QC3V phantom, and by taking images of an anthropomorphic pelvic phantom containing fiducial gold markers. Results: Either 30 mm of solid water or 3.3 mm of copper were found to be the most suitable buildup thicknesses with solid water providing more accurate results. Using solid water buildup, the EPID response compared to the reference dosimeter within 2% for all conditions except phantom thicknesses larger than 25 cm in 6 MV beams, which was up to 6.5%. Gamma evaluation results comparing EPID profiles and reference ionization chamber profiles showed that for 6 and 18 MV beams, at least 91.8% and 90.9% of points had a Gamma<1 for all phantoms, respectively. But using copper buildup, the EPID response had more discrepancies from the ionization chamber reference measurements, including: More than 2% difference for small air gaps using 6 MV beams, up to 8% difference for phantom thicknesses larger than 25 cm in 6 MV beams, and large differences (up to 9.3%) for increasing phantom thicknesses in 18 MV beams. The percentage of points with Gamma<1 with copper buildup were at least 96.6% and 99.8% in 6 and 18 MV beams, respectively. Conclusions: The direct EPID performs as an ion-chamber detector for transit dosimetry applications in all geometries studied except for small discrepancies at 6 MV for thick phantoms. This can be ameliorated by the calibration of the EPID to dose at an intermediate phantom thickness. The major current limitation of the direct EPID is poor quality of images compared with the clinical configuration, which could be overcome by a method to interchange between imaging and dosimetry setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo characterization of skin doses in 6 MV transverse field MRI-linac systems: Effect of field size, surface orientation, magnetic field strength, and exit bolus

Purpose: The main focus of this work is to continue investigations into the Monte Carlo predicted skin doses seen in MRI-guided radiotherapy. In particular, the authors aim to characterize the 70 {mu}m skin doses over a larger range of magnetic field strength and x-ray field size than in the current literature. The effect of surface orientation on both the entry and exit sides is also studied. Finally, the use of exit bolus is also investigated for minimizing the negative effects of the electron return effect (ERE) on the exit skin dose. Methods: High resolution GEANT4 Monte Carlo simulations of a water phantom exposed to a 6 MV x-ray beam (Varian 2100C) have been performed. Transverse magnetic fields of strengths between 0 and 3 T have been applied to a 30x30x20 cm{sup 3} phantom. This phantom is also altered to have variable entry and exit surfaces with respect to the beam central axis and they range from -75 deg. to +75 deg. The exit bolus simulated is a 1 cm thick (water equivalent) slab located on the beam exit side. Results: On the entry side, significant skin doses at the beam central axis are reported for large positive surface angles and strong magnetic fields. However, over the entry surface angle range of -30 deg. to -60 deg., the entry skin dose is comparable to or less than the zero magnetic field skin dose, regardless of magnetic field strength and field size. On the exit side, moderate to high central axis skin dose increases are expected except at large positive surface angles. For exit bolus of 1 cm thickness, the central axis exit skin dose becomes an almost consistent value regardless of magnetic field strength or exit surface angle. This is due to the almost complete absorption of the ERE electrons by the bolus. Conclusions: There is an ideal entry angle range of -30 deg. to -60 deg. where entry skin dose is comparable to or less than the zero magnetic field skin dose. Other than this, the entry skin dose increases are significant, especially at higher magnetic fields. On the exit side there is mostly moderate to high skin dose increases for 0.2-3 T with the only exception being large positive angles. Exit bolus of 1 cm thickness will have a significant impact on lowering such exit skin dose increases that occur as a result of the ERE.

60 APPLIED LIFE SCIENCES↗

Use of a realistic breathing lung phantom to evaluate dose delivery errors

Purpose: To compare the effect of respiration-induced motion on delivered dose (the interplay effect) for different treatment techniques under realistic clinical conditions. Methods: A flexible resin tumor model was created using rapid prototyping techniques based on a computed tomography (CT) image of an actual tumor. Twenty micro-MOSFETs were inserted into the tumor model and the tumor model was inserted into an anthropomorphic breathing phantom. Phantom motion was programed using the motion trajectory of an actual patient. A four-dimensional CT image was obtained and several treatment plans were created using different treatment techniques and planning systems: Conformal (Eclipse), step-and-shoot intensity-modulated radiation therapy (IMRT) (Pinnacle), step-and-shoot IMRT (XiO), dynamic IMRT (Eclipse), complex dynamic IMRT (Eclipse), hybrid IMRT [60% conformal, 40% dynamic IMRT (Eclipse)], volume-modulated arc therapy (VMAT) [single-arc (Eclipse)], VMAT [double-arc (Eclipse)], and complex VMAT (Eclipse). The complex plans were created by artificially pushing the optimizer to give complex multileaf collimator sequences. Each IMRT field was irradiated five times and each VMAT field was irradiated ten times, with each irradiation starting at a random point in the respiratory cycle. The effect of fractionation was calculated by randomly summing the measured doses. The maximum deviation for each measurement point per fraction and the probability that 95% of the model tumor had dose deviations less than 2% and 5% were calculated as a function of the number of fractions. Tumor control probabilities for each treatment plan were calculated and compared. Results: After five fractions, measured dose deviations were less than 2% for more than 95% of measurement points within the tumor model for all plans, except the complex dynamic IMRT, step-and-shoot IMRT (XiO), complex VMAT, and single-arc VMAT plans. Reducing the dose rate of the complex IMRT plans from 600 to 200 MU/min reduced the dose deviations to less than 2%. Dose deviations were less than 5% after five fractions for all plans, except the complex single-arc VMAT plan. Conclusions: Rapid prototyping techniques can be used to create realistic tumor models. For most treatment techniques, the dose deviations averaged out after several fractions. Treatments with unusually complicated multileaf collimator sequences had larger dose deviations. For IMRT treat-ments, dose deviations can be reduced by reducing the dose rate. For VMAT treatments, using two arcs instead of one is effective for reducing dose deviations.

60 APPLIED LIFE SCIENCES↗