Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

A Beam-Specific Planning Target Volume (PTV) Design for Proton Therapy to Account for Setup and Range Uncertainties

Purpose: To report a method for explicitly designing a planning target volume (PTV) for treatment planning and evaluation in heterogeneous media for passively scattered proton therapy and scanning beam proton therapy using single-field optimization (SFO). Methods and Materials: A beam-specific PTV (bsPTV) for proton beams was derived by ray-tracing and shifting ray lines to account for tissue misalignment in the presence of setup error or organ motion. Range uncertainties resulting from inaccuracies in computed tomography-based range estimation were calculated for proximal and distal surfaces of the target in the beam direction. The bsPTV was then constructed based on local heterogeneity. The bsPTV thus can be used directly as a planning target as if it were in photon therapy. To test the robustness of the bsPTV, we generated a single-field proton plan in a virtual phantom. Intentional setup and range errors were introduced. Dose coverage to the clinical target volume (CTV) under various simulation conditions was compared between plans designed based on the bsPTV and a conventional PTV. Results: The simulated treatment using the bsPTV design performed significantly better than the plan using the conventional PTV in maintaining dose coverage to the CTV. With conventional PTV plans, the minimum coverage to the CTV dropped from 99% to 67% in the presence of setup error, internal motion, and range uncertainty. However, plans using the bsPTV showed minimal drop of target coverage from 99% to 94%. Conclusions: The conventional geometry-based PTV concept used in photon therapy does not work well for proton therapy. We investigated and validated a beam-specific PTV method for designing and evaluating proton plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An adaptive local reduced basis method for solving PDEs with uncertain inputs and evaluating risk

Many physical systems are modeled using partial differential equations (PDEs) with uncertain or random inputs. For such systems, naively propagating a fixed number of samples of the input probability law (or an approximation thereof) through the PDE is often inadequate to accurately quantify the "risk" associated with critical system responses. In this paper, we develop a goal-oriented, adaptive sampling and local reduced basis approximation for PDEs with random inputs. Our method determines a set of samples and an associated (implicit) Voronoi partition of the parameter domain on which we build local reduced basis approximations of the PDE solution. The samples are selected in an adaptive manner using an a posteriori error indicator. A notable advantage of the proposed approach is that the computational cost of the approximation during the adaptive process remains constant. We provide theoretical error bounds for our approximation and numerically demonstrate the performance of our method when compared to widely used adaptive sparse grid techniques. In addition, we tailor our approach to accurately quantify the risk of quantities of interest that depend on the PDE solution. We demonstrate our method on an advection-diffusion example and a Helmholtz example. Keywords: stochastic partial differential equation, adaptive sampling, reduced basis, a posteriori error estimation, coherent risk measure, conditional value-at-risk.

42 ENGINEERING↗

Development of a Micro-Computed Tomography-Based Image-Guided Conformal Radiotherapy System for Small Animals

Purpose: To report on the physical aspects of a system in which radiotherapy functionality was added to a micro-computed tomography (microCT) scanner, to evaluate the accuracy of this instrument, and to and demonstrate the application of this technology for irradiating tumors growing within the lungs of mice. Methods and Materials: A GE eXplore RS120 microCT scanner was modified by the addition of a two-dimensional subject translation stage and a variable aperture collimator. Quality assurance protocols for these devices, including measurement of translation stage positioning accuracy, collimator aperture accuracy, and collimator alignment with the X-ray beam, were devised. Use of this system for image-guided radiotherapy was assessed by irradiation of a solid water phantom as well as of two mice bearing spontaneous MYC-induced lung tumors. Radiation damage was assessed ex vivo by immunohistochemical detection of {gamma}H2AX foci. Results: The positioning error of the translation stage was found to be <0.05 mm, whereas after alignment of the collimator with the X-ray axis through adjustment of its displacement and rotation, the collimator aperture error was <0.1 mm measured at isocenter. Computed tomography image-guided treatment of a solid water phantom demonstrated target localization accuracy to within 0.1 mm. Gamma-H2AX foci were detected within irradiated lung tumors in mice, with contralateral lung tissue displaying background staining. Conclusions: Addition of radiotherapy functionality to a microCT scanner is an effective means of introducing image-guided radiation treatments into the preclinical setting. This approach has been shown to facilitate small-animal conformal radiotherapy while leveraging existing technology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation and Sensitivity Analysis of a 1-D Lake Model Across Global Lakes

Lakes have important influence on weather and climate from local to global scales. However, their prediction using numerical models is notoriously difficult because lakes are highly heterogeneous across the globe, but observations are sparse. In this study, we assessed the performance of a 1-D lake model in simulating the thermal structures of 58 lakes with diverse morphometric and geographic characteristics by following the phase 2a local lake protocol of the Inter-sectoral Impact Model Intercomparison Project (ISIMIP2a). After calibration, the root-mean-square errors (RMSE) were below 2 °C for 70% and 75% of the lakes for epilimnion and full-profile temperature simulations, with an average of 1.71 °C and 1.43 °C, respectively. The model performance mainly depended on lake shape rather than location, supporting the possibility of grouping model parameters by lake shape for global applications. Furthermore, through machine-learning based parameter sensitivity tests, we identified turbulent heat fluxes, wind-driven mixing and water transparency as the major processes controlling lake thermal and mixing regimes. Snow density was also important for modeling the ice phenology of high-latitude lakes. The relative influence of the key processes and the corresponding parameters mainly depended on lake latitude and depth. Turbulent heat fluxes showed a decreasing importance in affecting epilimnion temperature with increasing latitude. Wind-driven mixing was less influential to lake stratification for deeper lakes while the impact of light extinction, on the contrary, showed a positive correlation with depth. Our findings may guide improvements in 1-D lake model parameterizations to achieve higher fidelity in simulating global lake thermal dynamics.

54 ENVIRONMENTAL SCIENCES↗

Testing for a pure state with local operations and classical communication

We examine the problem of using local operations and classical communication (LOCC) to distinguish a known pure state from an unknown (possibly mixed) state, bounding the error probability from above and below. We study the asymptotic rate of detecting multiple copies of the pure state and show that, if the overlap of the two states is great enough, then they can be distinguished asymptotically as well with LOCC as with global measurements; otherwise, the maximal Schmidt coefficient of the pure state is sufficient to determine the asymptotic error rate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Perspective: How good is DFT for water?

Kohn-Sham density functional theory (DFT) has become established as an indispensable tool for investigating aqueous systems of all kinds, including those important in chemistry, surface science, biology, and the earth sciences. Nevertheless, many widely used approximations for the exchange-correlation (XC) functional describe the properties of pure water systems with an accuracy that is not fully satisfactory. The explicit inclusion of dispersion interactions generally improves the description, but there remain large disagreements between the predictions of different dispersion-inclusive methods. We present here a review of DFT work on water clusters, ice structures, and liquid water, with the aim of elucidating how the strengths and weaknesses of different XC approximations manifest themselves across this variety of water systems. Our review highlights the crucial role of dispersion in describing the delicate balance between compact and extended structures of many different water systems, including the liquid. By referring to a wide range of published work, we argue that the correct description of exchange-overlap interactions is also extremely important, so that the choice of semi-local or hybrid functional employed in dispersion-inclusive methods is crucial. The origins and consequences of beyond-2-body errors of approximate XC functionals are noted, and we also discuss the substantial differences between different representations of dispersion. We propose a simple numerical scoring system that rates the performance of different XC functionals in describing water systems, and we suggest possible future developments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE COSMOLOGICAL BULK FLOW: CONSISTENCY WITH {Lambda}CDM AND z {approx} 0 CONSTRAINTS ON {sigma}{sub 8} AND {gamma}

We derive estimates for the cosmological bulk flow from the SFI++ Tully-Fisher (TF) catalog. For a sphere of radius 40 h{sup -1} Mpc centered on the Milky Way, we derive a bulk flow of 333 {+-} 38 km s{sup -1} toward Galactic (l, b) = (276 deg., 14 deg.) within a 3{sup 0} 1{sigma} error. Within a radius of 100h{sup -1} Mpc we get 257 {+-} 44 km s{sup -1} toward (l, b) = (279 deg., 10 deg.) within a 6 deg. error. These directions are at 40 deg. to the Supergalactic plane, close to the apex of the motion of the Local Group of galaxies after the Virgocentric infall correction. Our findings are consistent with the {Lambda}CDM model with the latest Wilkinson Microwave Anisotropy Probe (WMAP) best-fit cosmological parameters, but the bulk flow allows independent constraints. For the WMAP-inferred Hubble parameter h = 0.71 and baryonic mean density parameter {Omega}{sub b} = 0.0449, the constraint from the bulk flow on the matter density, {Omega}{sub m}, the normalization of the density fluctuations, {sigma}{sub 8}, and the growth index, {gamma}, can be expressed as {sigma}{sub 8}{Omega}{sup {gamma}-0.55}{sub m}({Omega}{sub m}/0.266){sup 0.28} = 0.86 {+-} 0.11 (for {Omega}{sub m} {approx} 0.266). Fixing {sigma}{sub 8} = 0.8 and {Omega}{sub m} = 0.266 as favored by WMAP, we get {gamma} = 0.495 {+-} 0.096. The constraint derived here rules out popular Dvali-Gabadadze-Porrati models at more than the 99% confidence level. Our results are based on the All Space Constrained Estimate (ACSE) model which reconstructs the bulk flow from an all space three-dimensional peculiar velocity field constrained to match the TF measurements. At large distances, ASCE generates a robust bulk flow from the SFI++ survey that is insensitive to the assumed prior. For comparison, a standard straightforward maximum likelihood estimate leads to very similar results.

79 ASTRONOMY AND ASTROPHYSICS↗

PHOTOMETRIC REDSHIFT PROBABILITY DISTRIBUTIONS FOR GALAXIES IN THE SDSS DR8

We present redshift probability distributions for galaxies in the Sloan Digital Sky Survey (SDSS) Data Release 8 imaging data. We used the nearest-neighbor weighting algorithm to derive the ensemble redshift distribution N(z), and individual redshift probability distributions P(z) for galaxies with r < 21.8 and u < 29.0. As part of this technique, we calculated weights for a set of training galaxies with known redshifts such that their density distribution in five-dimensional color-magnitude space was proportional to that of the photometry-only sample, producing a nearly fair sample in that space. We estimated the ensemble N(z) of the photometric sample by constructing a weighted histogram of the training-set redshifts. We derived P(z)'s for individual objects by using training-set objects from the local color-magnitude space around each photometric object. Using the P(z) for each galaxy can reduce the statistical error in measurements that depend on the redshifts of individual galaxies. The spectroscopic training sample is substantially larger than that used for the DR7 release. The newly added PRIMUS catalog is now the most important training set used in this analysis by a wide margin. We expect the primary sources of error in the N(z) reconstruction to be sample variance and spectroscopic failures: The training sets are drawn from relatively small volumes of space, and some samples have large incompleteness. Using simulations we estimated the uncertainty in N(z) due to sample variance at a given redshift to be {approx}10%-15%. The uncertainty on calculations incorporating N(z) or P(z) depends on how they are used; we discuss the case of weak lensing measurements. The P(z) catalog is publicly available from the SDSS Web site.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of error fields and error field correction on heat fluxes in SPARC

Using a single toroidal array of coils to reduce the m,n = 2,1 resonant error field (EF) produced by the misalignment of the axisymmetric coils in SPARC can result in the enhancement of the local divertor heat fluxes. Managing high divertor heat fluxes (q ∥ $\simeq$ 10 GW m -2 ) poses a challenge for compact tokamak devices such as SPARC. The presence of non-axisymmetric magnetic field perturbations adds complexity to the problem by generating intricate 3D edge magnetic topologies that alter the heat flux distributions on the target plates. The aim of this work is to investigate the impact of the EF correction (EFC) on the heat fluxes at the divertor plates in SPARC. The MHD code M3DC1 has been used to simulate the 3D magnetic perturbations generated by the shift and tilt of several axisymmetric coils within specified tolerances, as well as from the array of EFC coils located at the midplane. Using a heuristic model that extends the concept of an axisymmetric heat flux layer to 3D plasmas, the resultant heat flux distributions is derived from magnetic footprints calculated with the MAFOT code. The results show that the EFC could either decrease or further enhance the local heat flux when used to correct the m,n = 2,1 resonant EF to enhance the core plasma performance.

3D fields↗

Neutron and proton electric dipole moments from N f =2+1 domain-wall fermion lattice QCD

We present a lattice calculation of the neutron and proton electric dipole moments (EDM’s) with N f = 2 + 1 flavors of domain-wall fermions. The neutron and proton EDM form factors are extracted from three-point functions at the next-to-leading order in the θ vacuum of QCD. In this computation, we use pion masses 330 and 420 MeV and 2.7 fm 3 lattices with Iwasaki gauge action and a 170 MeV pion and 4.6 fm 3 lattice with I-DSDR gauge action, all generated by the RBC and UKQCD collaborations. The all-mode-averaging technique enables an efficient, high statistics calculation; however the statistical errors on our results are still relatively large, so we investigate a new direction to reduce them, reweighting with the local topological charge density which appears promising. Furthermore, we discuss the chiral behavior and finite size effects of the EDM’s in the context of baryon chiral perturbation theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

WE-AB-BRB-10: Filmless QA of CyberKnife MLC-Collimated and Iris-Collimated Fields

Purpose: Current methods of CK field shape QA is based on the use of radiochromic film. Though accurate results can be attained, these methods are prone to error, time consuming, and expensive. The techniques described herein perform similar QA using the FOIL Detector (Field, Output, and Image Localization). A key feature of this in-house QA solution, and central to this study, is an aSi flat-panel detector which provides the user with the means to perform accurate, immediate, and quantitative field analysis. Methods: The FOIL detector is automatically aligned in the CK beam using fiducial markers implanted within the detector case. Once the system is aligned, a treatment plan is delivered which irradiates the flat-panel imager using the field being tested. The current study tests each of the clinically-used fields shaped using the Iris variable-aperture collimation system using a plan which takes 6 minutes to deliver. The user is immediately provided with field diameter and beam profile, as well as a comparison to baseline values. Additionally, the detector is used to acquire and analyze leaf positions of the InCise multi-leaf collimation system. Results: Using a 6-minute plan consisting of 11 beams of 25MU-per-beam, the FOIL detector provided the user with a quantitative analysis of all clinically-used field shapes. The FOIL detector was also able to clearly resolve field edge junctions in a picket fence test, including slight over-travel of individual leaves as well as inter-leaf leakage. Conclusion: The FOIL system provided comparable field diameter and profile data when compared to methods using film; providing results much faster and with 5% of the MU used for film. When used with the MLC system, the FOIL detector provided the means for immediate quantification of the performance of the system through analysis of leaf positions in a picket fence test field. Author is the President/Owner of Spectrum Medical Physics, LLC, a company which maintains contracts with Siemens Healthcare and Standard Imaging, Inc.

60 APPLIED LIFE SCIENCES↗

Search for Continuous and Transient Neutrino Emission Associated with IceCube’s Highest-energy Tracks: An 11 yr Analysis

IceCube alert events are neutrinos with a moderate-to-high probability of having astrophysical origin. In this study, we analyze 11 yr of IceCube data and investigate 122 alert events and a selection of high-energy tracks detected between 2009 and the end of 2021. This high-energy event selection (alert events + high-energy tracks) has an average probability of ≥0.5 of being of astrophysical origin. We search for additional continuous and transient neutrino emission within the high-energy events' error regions. We find no evidence for significant continuous neutrino emission from any of the alert event directions. The only locally significant neutrino emission is the transient emission associated with the blazar TXS 0506+056, with a local significance of 3σ, which confirms previous IceCube studies. When correcting for 122 test positions, the global p-value is 0.156 and compatible with the background hypothesis. We constrain the total continuous flux emitted from all 122 test positions at 100 TeV to be below 1.2 × 10 –15 (TeV cm 2 s) –1 at 90% confidence assuming an E –2 spectrum. This corresponds to 4.5% of IceCube's astrophysical diffuse flux. Overall, we find no indication that alert events in general are linked to lower-energetic continuous or transient neutrino emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Tracking Accuracy of a Real-Time Fiducial Tracking System for Patient Positioning and Monitoring in Radiation Therapy

Purpose: In radiation therapy there is a need to accurately know the location of the target in real time. A novel radioactive tracking technology has been developed to answer this need. The technology consists of a radioactive implanted fiducial marker designed to minimize migration and a linac mounted tracking device. This study measured the static and dynamic accuracy of the new tracking technology in a clinical radiation therapy environment. Methods and Materials: The tracking device was installed on the linac gantry. The radioactive marker was located in a tissue equivalent phantom. Marker location was measured simultaneously by the radioactive tracking system and by a Microscribe G2 coordinate measuring machine (certified spatial accuracy of 0.38 mm). Localization consistency throughout a volume and absolute accuracy in the Fixed coordinate system were measured at multiple gantry angles over volumes of at least 10 cm in diameter centered at isocenter. Dynamic accuracy was measured with the marker located inside a breathing phantom. Results: The mean consistency for the static source was 0.58 mm throughout the tested region at all measured gantry angles. The mean absolute position error in the Fixed coordinate system for all gantry angles was 0.97 mm. The mean real-time tracking error for the dynamic source within the breathing phantom was less than 1 mm. Conclusions: This novel radioactive tracking technology has the potential to be useful in accurate target localization and real-time monitoring for radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Directional finite difference method for directly solving 3D gyrokinetic field equations with enhanced accuracy

The gyrokinetic (GK) field equation is a three-dimensional (3D) elliptic equation, but it is often simplified to a set of two-dimensional (2D) equations by assuming that the field does not vary along a specific direction. However, this simplification can introduce inevitable 0th-order numerical errors, as nonlinear mode coupling in toroidal geometry can produce undesirable harmonic modes that violate the assumption. In this work, we propose a novel directional finite difference method (FDM) with a local coordinate transformation to better resolve the target field of interest. The directional FDM can accurately solve 3D GK field equations without simplifications, which can overcome the limitations of conventional methods. The accuracy and efficiency of different FDMs are analyzed in great detail for a variety of geometries, from simple 2D Cartesian coordinates to realistic 3D curvilinear coordinates. The 0th-order numerical errors of simplified 2D GK equations were found to be more problematic for low-harmonic modes and low aspect ratio geometries such as spherical tokamaks. On the other hand, the directional 3D FDM can accurately resolve a much wider range of harmonic modes aligned to the direction of interest, including the low-harmonic modes. In conclusion, we demonstrate that the directional 3D FDM is a highly effective algorithm for solving the 3D GK field equations, achieving accuracy improvements of 10 to 100 times or more, particularly for low-harmonic modes in spherical tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Local bounds preserving stabilization for continuous Galerkin discretization of hyperbolic systems

The objective of this paper is to present a local bounds preserving stabilized finite element scheme for hyperbolic systems on unstructured meshes based on continuous Galerkin (CG) discretization in space. A CG semi-discrete scheme with low order artificial dissipation that satisfies the local extremum diminishing (LED) condition for systems is used to discretize a system of conservation equations in space. The low order artificial diffusion is based on approximate Riemann solvers for hyperbolic conservation laws. In this case we consider both Rusanov and Roe artificial diffusion operators. In the Rusanov case, two designs are considered, a nodal based diffusion operator and a local projection stabilization operator. The result is a discretization that is LED and has first order convergence behavior. To achieve high resolution, limited antidiffusion is added back to the semi-discrete form where the limiter is constructed from a linearity preserving local projection stabilization operator. The procedure follows the algebraic flux correction procedure usually used in flux corrected transport algorithms. To further deal with phase errors (or terracing) common in FCT type methods, high order background dissipation is added to the antidiffusive correction. The resulting stabilized semi-discrete scheme can be discretized in time using a wide variety of time integrators. Numerical examples involving nonlinear scalar Burgers equation, and several shock hydrodynamics simulations for the Euler system are considered to demonstrate the performance of the method. In conclusion, for time discretization, Crank–Nicolson scheme and backward Euler scheme are utilized.

97 MATHEMATICS AND COMPUTING↗

Vertical detachment energies of ammonia cluster anions using self-interaction-corrected methods

Systems with weakly bound extra electrons impose great challenges to semilocal density functional approximations (DFAs), which suffer from self-interaction errors. Small ammonia clusters are one such example of weakly bound anions where the extra electron is weakly bound. We applied two self-interaction correction (SIC) schemes, viz., the well-known Perdew–Zunger and the recently developed locally scaled SIC (LSIC) with the local spin density approximation (LSDA), Perdew–Burke–Ernzerhof (PBE) generalized gradient approximation (GGA), and the SCAN meta-GGA functionals to calculate the vertical detachment energies (VDEs) of small ammonia cluster anions (NH3)n–. Our results show that the LSIC significantly reduces the errors in calculations of VDE with LSDA and PBE-GGA functionals leading to better agreement with the reference values calculated with coupled cluster singles and doubles with perturbative triples [CCSD(T)]. Accurate prediction of VDE as an absolute of the highest occupied molecular orbital (HOMO) is challenging for DFAs. Our results show that VDEs estimated from the negative of HOMO eigenvalues with the LSIC-LSDA and Perdew–Zunger SIC-PBE are within 11 meV of the reference CCSD(T) results. Here, the LSIC method performs consistently well for the VDE estimates, from both the total energy differences and the absolute HOMO eigenvalues.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gyrokinetic neoclassical study of the bootstrap current in the tokamak edge pedestal with fully non-linear Coulomb collisions

As a follow-up on the drift-kinetic study of the non-local bootstrap current in the steep edge pedestal of tokamak plasma by Koh et al. [Phys. Plasmas 19, 072505 (2012)], a gyrokinetic neoclassical study is performed with gyrokinetic ions and drift-kinetic electrons. Besides the gyrokinetic improvement of ion physics from the drift-kinetic treatment, a fully non-linear Fokker-Planck collision operator—that conserves mass, momentum, and energy—is used instead of Koh et al.'s linearized collision operator in consideration of the possibility that the ion distribution function is non-Maxwellian in the steep pedestal. An inaccuracy in Koh et al.'s result is found in the steep edge pedestal that originated from a small error in the collisional momentum conservation. The present study concludes that (1) the bootstrap current in the steep edge pedestal is generally smaller than what has been predicted from the small banana-width (local) approximation [e.g., Sauter et al., Phys. Plasmas 6, 2834 (1999) and Belli et al., Plasma Phys. Controlled Fusion 50, 095010 (2008)], (2) the plasma flow evaluated from the local approximation can significantly deviate from the non-local results, and (3) the bootstrap current in the edge pedestal, where the passing particle region is small, can be dominantly carried by the trapped particles in a broad trapped boundary layer. A new analytic formula based on numerous gyrokinetic simulations using various magnetic equilibria and plasma profiles with self-consistent Grad-Shafranov solutions is constructed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗