Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

SU-E-T-483: In Vivo Dosimetry of Conventional and Rotational Intensity Modulated Radiotherapy Using Integral Quality Monitor (IQM)

Purpose: To investigate the accuracy, sensitivity and constancy of integral quality monitor (IQM), a new system for in vivo dosimetry of conventional intensity modulated radiation therapy (IMRT) or rotational volumetric modulated arc therapy (VMAT) Methods: A beta-version IQM system was commissioned on an Elekta Infinity LINAC equipped with 160-MLCs Agility head. The stationary and rotational dosimetric constancy of IQM was evaluated, using five-field IMRT and single-or double-arc VMAT plans for prostate and head-and-neck (H&N) patients. The plans were delivered three times over three days to assess the constancy of IQM response. Picket fence (PF) fields were used to evaluate the sensitivity of detecting MLC leaf errors. A single leaf offset was intentionally introduced during delivery of various PF fields with segment apertures of 3×1, 5×1, 10×1, and 24×1cm2. Both 2mm and 5mm decrease in the field width were used. Results: Repeated IQM measurements of prostate and H&N IMRT deliveries showed 0.4 and 0.5% average standard deviation (SD) for segment-by-segment comparison and 0.1 and 0.2% for cumulative comparison. The corresponding SDs for VMAT deliveries were 6.5, 9.4% and 0.7, 1.3%, respectively. Statistical analysis indicates that the dosimetric differences detected by IQM were significant (p < 0.05) in all PF test deliveries. The largest average IQM signal response of a 2 mm leaf error was found to be 2.1% and 5.1% by a 5mm leaf error for 3×1 cm2 field size. The same error in 24×1 cm2 generates a 0.7% and 1.4% difference in the signal. Conclusion: IQM provides an effective means for real-time dosimetric verification of IMRT/ VMAT treatment delivery. For VMAT delivery, the cumulative dosimetry of IQM needs to be used in clinical practice.

60 APPLIED LIFE SCIENCES↗

Impact of numerics on the predictive capabilities of reacting flow LES

Combustors in modern aerospace propulsion systems are highly optimized devices and further enhancements to their performance will require advanced predictive modeling techniques. The LES approach has potential to be such a technique, but demonstration of its true predictive capability remains a challenge. In this paper, a methodical study is performed to assess the impact of numerical error on the predictive capabilities of LES and to distinguish it from error arising from physical modeling. Four codes are employed to simulate the bluff body stabilized flame experiment of Volvo Flygmotor AB. The physical models (governing equations and sub-grid models) are kept identical between the codes so that the physical modeling error is the same. For the same reason, computational grids are also kept identical since the sub-grid models are grid dependent. Results indicate that all codes produce a very similar solution for the non-reacting flow in terms of large scale unsteady vortex shedding behavior, mean profiles and second order turbulence statistics, on a suitably refined grid. This solution is also very close to the experimentally observed behavior of the flow. In contrast, for the reacting case, solutions from the various codes exhibit significant differences when analyzed under the same metrics and with similar or even finer grid resolution than that used for the non-reacting case. These differences are large enough to change the macroscopic behavior of the flow, e.g. some codes predict symmetric vortex shedding while others predict asymmetric shedding and some codes show strong recirculation zones while others show stagnant regions behind the bluff body. It is also shown that none of the solutions truly predicts the experimentally observed flow. Given that the physical sub-grid models and computational grids are the same in all the simulations, the inconsistency between results points to a significant impact of numerical methods and, hence, numerical error. The need for mitigation of this impact is highlighted, along with the need for metrics detailing how LES should be applied to reacting flows. It is suggested that both of these issues should be the focus of future work.

Energy & Fuels↗

Understanding Biases in Simulated Cloud Radiative Effects in E3SMv3

This study systematically investigates biases in cloud radiative effects (CREs) within the recently released Energy Exascale Earth System Model version 3 (E3SMv3). Compared to its previous version (E3SMv2), E3SMv3 shows excessively strong shortwave CRE over tropical and subtropical oceans, the Southern Ocean, and the Northern Hemisphere storm tracks, which is primarily caused by an overestimation of optically intermediate low clouds. The model also displays excessive longwave CRE over the Maritime Continent and other tropical deep convection regions, resulting from an overestimation of optically thick high clouds. Implementing the Predicted Particle Properties (P3) scheme for stratiform clouds played the most significant role in these cloud changes. In addition, using a double-moment scheme for convective clouds contributed to the increase in intermediate low clouds and optically thick clouds in tropical deep convection regions. Error metrics for total cloud amount (E TCA ), cloud properties (E ctp-τ ), and cloud properties weighted by their SW and LW radiative impacts (E SW and E LW ) indicate that E3SMv3's ability to reproduce observed cloud radiative effect of low, middle, and high clouds has not been improved compared to E3SMv2. Nevertheless, the performance of E3SMv3 remains well within the spread of CMIP6 models, with E SW and E LW values smaller than those in most CMIP6 models. This study underscores the importance of integrating diverse satellite observations for robust cloud evaluation and using cloud-radiation relationships as consistency check for model errors. It suggests that further model developments focus on improving cloud microphysics and their interactions with radiation.

Environmental sciences↗

SU-E-T-550: Modulation Index for VMAT

Purpose: To present modulation indices (MIs) for volumetric modulated arc therapy (VMAT). Methods: A total of 40 VMAT plans were retrospectively selected. To investigate the delivery accuracy of each VMAT plan, gamma passing rates, differences in modulating parameters between plans and log files, and differences between the original plans and the plans reconstructed with the log files were acquired. A modulation index (MIt) was designed by multiplications of the weighted quantifications of MLC speeds, MLC accelerations, gantry accelerations and dose-rate variations. Textural features including angular second moment, inverse difference moment, contrast, variance, correlation and entropy were calculated from the fluences of each VMAT plan. To test the performance of suggested MIs, Spearman’s rank correlation coefficients (r) with the plan delivery accuracy were calculated. Conventional modulation indices for VMAT including the modulation complexity score for VMAT (MCSv), leaf travel modulation complexity score (LTMCS) and MI by Li & Xing were calculated, and their correlations were also analyzed in the same way. Results: The r values of contrast (particular displacement distance, d = 1), variance (d = 1), MIt, MCSv, LTMCS and MI by Li&Xing to the local gamma passing rates with 2%/2 mm were 0.547 (p < 0.001), 0.519 (p < 0.001), −0.658 (p < 0.001), 0.186 (p = 0.251), 0.312 (p = 0.05) and −0.455 (p = 0.003), respectively. The r values of those to the MLC errors were −0.863, −0.828, 0.917, −0.635, − 0.857 and 0.795, respectively (p < 0.001). For dose-volumetric parameters, MIt showed higher statistically significant correlations than did the conventional modulation indices. Conclusion: The MIt, contrast (d = 1) and variance (d = 1) showed good performance to predict the VMAT delivery accuracy showing higher correlations to the results of various types of verification methods for VMAT. This work was in part supported by the National Research Foundation of Korea (NRF) grant (no. 490-20140029 and no. 490-20130047) funded by the Korea government.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of the effect of noise parameters of a 3D lidar on the error in estimating relief signatures of distant objects from 2D field intensity distributions of reflected radiation

We consider the influence of noise parameters of a 3D lidar and external background radiation on the error in estimating the relief signatures of distant objects from 2D field intensity distributions of the reflected radiation. A physical and mathematical model is developed to analyse the effect of noise. The dependence of the error in estimating the relief signatures at various signal-to-noise ratios is investigated taking into account the parameters of real multi-element photodetectors (MEPDs). The obtained results indicate the possibility of evaluating relief signatures of distant objects with high accuracy based on standard MEPDs simultaneously for a large number of points on the object’s surface with a signal-to-noise ratio of more than 4. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An AFM Dynamic Contact Model with Finite Thickness Correction to Study Micro-Rheology of Biological Cells

One of the major sources of error in Atomic Force Microscopy based Force Spectroscopic studies is bottom substrate effect, which comes due to assumption of infinite sample thickness. In the present work, anew experimentally validated mathematical correction for finite thickness of thesample is incorporated into a dynamic indentation model. This model is an extension of Sneddon’s static indentation contact model developed for conical tip indenters by incorporating the tip geometric effects, correction to hydrodynamic drag, viscoelastic nature of the sample and its finite thickness. The new model is applied to extract the viscoelastic properties of primary mesenchymal stem cells (MSC’s) extracted from human bone marrow and HCT-116 aggressive epithelial colorectal cancer cells. The micro-rheological studies indicated the presence of profound influence of infinite thickness assumption depending upon indentation depth and sample thickness at the point of indentation. The present model nullified this error and provided a better estimate of the rheological properties. The tests were conducted over a wide frequency bandwidth (0.5 to 126 Hz) and frequency dependent material properties were analyzed using power law structural damping model. It was found that MSC’s are stiffer and less viscous in nature compared to cancer cells.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

MO-FG-303-04: A Smartphone Application for Automated Mechanical Quality Assurance of Medical Accelerators

Purpose: The mechanical quality assurance (QA) of medical accelerators consists of a time consuming series of procedures. Since most of the procedures are done manually – e.g., checking gantry rotation angle with the naked eye using a level attached to the gantry –, it is considered to be a process with high potential for human errors. To remove the possibilities of human errors and reduce the procedure duration, we developed a smartphone application for automated mechanical QA. Methods: The preparation for the automated process was done by attaching a smartphone to the gantry facing upward. For the assessments of gantry and collimator angle indications, motion sensors (gyroscope, accelerator, and magnetic field sensor) embedded in the smartphone were used. For the assessments of jaw position indicator, cross-hair centering, and optical distance indicator (ODI), an optical-image processing module using a picture taken by the high-resolution camera embedded in the smartphone was implemented. The application was developed with the Android software development kit (SDK) and OpenCV library. Results: The system accuracies in terms of angle detection error and length detection error were < 0.1° and < 1 mm, respectively. The mean absolute error for gantry and collimator rotation angles were 0.03° and 0.041°, respectively. The mean absolute error for the measured light field size was 0.067 cm. Conclusion: The automated system we developed can be used for the mechanical QA of medical accelerators with proven accuracy. For more convenient use of this application, the wireless communication module is under development. This system has a strong potential for the automation of the other QA procedures such as light/radiation field coincidence and couch translation/rotations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BXS Re-calibration

Early in the commissioning it was noticed by Cecile Limborg that the calibration of the BXS spectrometer magnet seemed to be different from the strength of the BX01/BX02 magnets. First the BX01/BX02 currents were adjusted to 135 MeV and the beam energy was adjusted to make the horizontal orbit flat. Then BX01/BX02 magnets were switched off and BXS was adjusted to make the horizontal orbit in the spectrometer line flat, without changing the energy of the beam. The result was that about 140-141 MeV were required on the BXS magnet. This measurement was repeated several times by others with the same results. It was not clear what was causing the error: magnet strength or layout. A position error of about 19 mm of the BXS magnet could explain the difference. Because there was a significant misalignment of the vacuum chamber in the BXS line, the alignment of the whole spectrometer line was checked. The vacuum chamber was corrected, but the magnets were found to be in the proper alignment. So we were left with one (or conceivably two) magnet calibration errors. Because BXS is a wedged shaped magnet, the bend angle depends on the horizontal position of the incoming beam. As mentioned, an offset of the beam position of 19 mm would increase or decrease the bend angle roughly by the ratio of 135/141. The figure of 19 mm is special and caused a considerable confusion during the design and measurement of the BXS magnet. This is best illustrated in Figure 1 which was taken out of the BXS Traveler document. The distance between the horizontal midplanes of the poles and the apex of the beam path was chosen to be 19 mm so the beam is close to the good field region throughout its entire path. Thus it seemed possible that there was an error that resulted in the beam not being on this trajectory, or conversely, that the magnetic measurements were done on the wrong trajectory and the magnet was then mis-calibrated. Mechanical measurements of the vacuum chamber made in the tunnel indicated that the vacuum chamber was in fact in the proper position with respect to the magnet - not 19 mm off to one side - so the former possibility was discounted. Review of the Fiducial Report and an interview with Keith Caban convinced me that there was no error in the coordinate system used for magnet measurements. I went and interviewed Andrew Fischer who did the magnetic measurements of BXS. He had extensive records, including photographs of the setups and could quickly answer quite detailed questions about how the measurement was done. Before the interview, I had a suspicion there might have been a sign flip in the x coordinate which because of the wedge would result in the wrong path length and a miscalibration. Andrew was able to pin-point how this could have happened and later confirmed it by looking an measurement data from the BXG magnet done just after BXS and comparing photographs. It turned out that the sign of the horizontal stage travel that drives the measurement wire was opposite that of the x coordinate in the Traveler, and the sign difference wasn't applied to the data. The origin x = 0 was set up correctly, but the wire moved in the opposite direction to what was expected, just as if the arc had been flipped over about the origin. To quantitatively confirm that this was the cause of the observed difference in calibration I used the 'grid data', which was taken with a Hall probe on the BXS magnet originally to measure the FINT (focusing effect) term, and combined it with the Hall probe data taken on the flipped trajectory, and performed the field integral on a path that should give the same result as the design path. This is best illustrated in Figure 2. The integration path is coincident with the desired path from the pivot points (x = 0) outward. Between the pivot points the integration path is a mirror image of the design path, but because the magnet is fairly uniform, for this portion it gives the same result. Most of the calibration error resulted simply from the different path length between the design path and the measured path. The results of the integration on the equivalent path are given in Table 1. The corrected calibration has been used to generate a new polynomial for BXS which was implemented in the control system.

43 PARTICLE ACCELERATORS↗

Scalable simultaneous multiqubit readout with 99.99% single-shot fidelity

We describe single-shot readout of a trapped-ion multiqubit register using space- and time-resolved camera detection. For a single qubit we measure 0.9(3)x10{sup -4} readout error in 400 {mu}s exposure time, limited by the qubit's decay lifetime. For a four-qubit register (a 'qunybble'), we measure an additional error of only 0.1(1)x10{sup -4} per qubit, despite the presence of 4% optical cross-talk between neighboring qubits. A study of the cross-talk indicates that the method would scale with a negligible loss of fidelity to {approx}10 000 qubits at a density of < or approx. 1 qubit/{mu}m{sup 2}, with a readout time of {approx}1 {mu}s/qubit.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Lyapunov and Sacker–Sell spectral stability theory for one-step methods

Approximation theory for Lyapunov and Sacker–Sell spectra based upon QR techniques is used to analyze the stability of a one-step method solving a time-dependent (nonautonomous) linear ordinary differential equation (ODE) initial value problem in terms of the local error. Integral separation is used to characterize the conditioning of stability spectra calculations. The stability of the numerical solution by a one-step method of a nonautonomous linear ODE using real-valued, scalar, nonautonomous linear test equations is justified. This analysis is used to approximate exponential growth/decay rates on finite and infinite time intervals and establish global error bounds for one-step methods approximating uniformly, exponentially stable trajectories of nonautonomous and nonlinear ODEs. A time-dependent stiffness indicator and a one-step method that switches between explicit and implicit Runge–Kutta methods based upon time-dependent stiffness are developed based upon the theoretical results.

97 MATHEMATICS AND COMPUTING↗

Assessment of Interfraction Patient Setup for Head-and-Neck Cancer Intensity Modulated Radiation Therapy Using Multiple Computed Tomography-Based Image Guidance

Purpose: Various image guidance systems are commonly used in conjunction with intensity modulated radiation therapy (IMRT) in head-and-neck cancer irradiation. The purpose of this study was to assess interfraction patient setup variations for 3 computed tomography (CT)-based on-board image guided radiation therapy (IGRT) modalities. Methods and Materials: A total of 3302 CT scans for 117 patients, including 53 patients receiving megavoltage cone-beam CT (MVCBCT), 29 receiving kilovoltage cone-beam CT (KVCBCT), and 35 receiving megavoltage fan-beam CT (MVFBCT), were retrospectively analyzed. The daily variations in the mediolateral (ML), craniocaudal (CC), and anteroposterior (AP) dimensions were measured. The clinical target volume-to-planned target volume (CTV-to-PTV) margins were calculated using 2.5Σ + 0.7 σ, where Σ and σ were systematic and random positioning errors, respectively. Various patient characteristics for the MVCBCT group, including weight, weight loss, tumor location, and initial body mass index, were analyzed to determine their possible correlation with daily patient setup. Results: The average interfraction displacements (± standard deviation) in the ML, CC, and AP directions were 0.5 ± 1.5, −0.3 ± 2.0, and 0.3 ± 1.7 mm (KVCBCT); 0.2 ± 1.9, −0.2 ± 2.4, and 0.0 ± 1.7 mm (MVFBCT); and 0.0 ± 1.8, 0.5 ± 1.7, and 0.8 ± 3.0 mm (MVCBCT). The day-to-day random errors for KVCBCT, MVFBCT, and MVCBCT were 1.4-1.6, 1.7, and 2.0-2.1 mm. The interobserver variations were 0.8, 1.1, and 0.7 mm (MVCBCT); 0.5, 0.4, and 0.8 mm (MVFBCT); and 0.5, 0.4, and 0.6 mm (KVCBCT) in the ML, CC, and AP directions, respectively. The maximal calculated uniform CTV-to-PTV margins were 5.6, 6.9, and 8.9 mm for KVCBCT, MVFBCT, and MVCBCT, respectively. For the evaluated patient characteristics, the calculated margins for different patient parameters appeared to differ; analysis of variance (ANOVA) and/or t test analysis found no statistically significant setup difference in any direction. Conclusions: Daily random setup errors and CTV-to-PTV margins for treatment of head-and-neck cancer were affected by imaging quality. Our data indicated that larger margins were associated with MVFBCT and MVCBCT, compared with smaller margins for KVCBCT. IGRT modalities with better image quality are encouraged in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A hybrid neural architecture: Online attosecond x-ray characterization

The emergence of high-repetition-rate x-ray free-electron lasers (XFELs), such as SLAC’s LCLS-II, serves as our canonical example for autonomous controls that necessitate high-throughput diagnostics paired with streaming computational pipelines capable of single-shot analysis with extremely low latency. We present the deterministic characterization with an integrated parallelizable hybrid resolver architecture, a hybrid machine learning framework designed for fast, accurate analysis of XFEL diagnostics using angular streaking-based sinogram images. This architecture integrates convolutional neural networks and bidirectional long short-term memory models to denoise input, identify x-ray sub-spike features, and extract sub-spike relative delays with sub-30 attosecond temporal resolution. Deployed on low-latency hardware, it achieves over 10 kHz throughput with 168.3 μs inference latency, indicating scalability to 14 kHz with field-programmable gate array integration. By transforming regression tasks into classification problems and leveraging optimized error encoding, we achieve high precision with low-latency performance that is critical for real-time streaming event selection and experimental control feedback signals. This represents a key development in real-time control pipelines for next-generation autonomous science, generally, and high repetition-rate x-ray experiments in particular.

Accelerator Physics (physics.acc-ph)↗

TRACING THE PECULIAR DARK MATTER STRUCTURE IN THE GALAXY CLUSTER Cl 0024+17 WITH INTRACLUSTER STARS AND GAS

Intracluster light (ICL) is believed to originate from the stars stripped from cluster galaxies. They are no longer gravitationally bound to individual galaxies, but to the cluster, and their smooth distribution potentially makes them serve as much denser tracers of the cluster dark matter than the sparsely distributed cluster galaxies. We present our study of the ICL in the galaxy cluster Cl 0024+17 using both Advanced Camera for Surveys (ACS) and Subaru data, where we previously reported the discovery of a ring-like dark matter structure with gravitational lensing. The ACS images provide much lower sky levels than ground-based data, and enable us to measure relative variation of surface brightness reliably. This analysis is repeated with the Subaru images to examine if consistent features are recovered despite a different reduction scheme and different instrumental characteristics. We find that the ICL profile clearly resembles the peculiar mass profile, which stops decreasing at r {approx} 50'' ({approx}265 kpc) and slowly increases until it turns over at r {approx} 75'' ({approx}397 kpc). This feature is seen in both ACS and Subaru images for nearly all available passband images while the features are in general stronger in red filters. The consistency across different filters and instruments strongly rules out the possibility that the feature might come from any residual, uncorrected calibration errors. In addition, our re-analysis of the cluster X-ray data shows that the peculiar mass structure is also indicated by a non-negligible (3.7{sigma} in Chandra and 2.4{sigma} in XMM-Newton) bump in the intracluster gas profile when the geometric center of the dark matter ring, not the peak of the X-ray emission, is chosen as the center of the radial bin. The location of the gas ring is closer to the center by {approx}15'' ({approx}80 kpc), raising an interesting possibility that the ring-like structure is expanding and the gas ring is lagging behind perhaps because of the ram pressure if both features in mass and gas share the same dynamical origin.

79 ASTRONOMY AND ASTROPHYSICS↗

Cosmology and astrophysics from relaxed galaxy clusters - IV: Robustly calibrating hydrostatic masses with weak lensing

This is the fourth in a series of papers studying the astrophysics and cosmology of massive, dynamically relaxed galaxy clusters. Here, we use measurements of weak gravitational lensing from the Weighing the Giants project to calibrate Chandra X-ray measurements of total mass that rely on the assumption of hydrostatic equilibrium. This comparison of X-ray and lensing masses measures the combined bias of X-ray hydrostatic masses from both astrophysical and instrumental sources. While we cannot disentangle the two sources of bias, only the combined bias is relevant for calibrating cosmological measurements using relaxed clusters. Assuming a fixed cosmology, and within a characteristic radius (r 2500 ) determined from the X-ray data, we measure a lensing to X-ray mass ratio of 0.96 ± 9% (stat) ± 9% (sys). We find no significant trends of this ratio with mass, redshift or the morphological indicators used to select the sample. Our results imply that any departures from hydrostatic equilibrium at these radii are offset by calibration errors of comparable magnitude, with large departures of tens-of-percent unlikely. In addition, we find a mean concentration of the sample measured from lensing data of c 200 = 3.0 +4.4 –1.8 . In conclusion, anticipated short-term improvements in lensing systematics, and a modest expansion of the relaxed lensing sample, can easily increase the measurement precision by 30–50%, leading to similar improvements in cosmological constraints that employ X-ray hydrostatic mass estimates, such as on Ω m from the cluster gas mass fraction.

79 ASTRONOMY AND ASTROPHYSICS↗

A dendritic strontium river isoscape for fisheries applications in the Sacramento River basin, California, USA

Objective Understanding the origins and movements of fish is fundamental to effective conservation and fisheries management. Strontium isotope ratios ( 87 Sr/ 86 Sr) in otoliths provide a powerful tracer of natal origin and migratory pathways. However, existing 87 Sr/ 86 Sr isoscapes for the Sacramento River basin, an ecosystem that supports ecologically and economically important salmon populations, rely on discrete classification approaches that overlook unsampled habitats and do not incorporate spatial uncertainty. Our objective was to develop a continuous, network-explicit 87 Sr/ 86 Sr isoscape with quantified uncertainty to fill in data gaps and enable probabilistic assignments of fish origin and movement. Methods We used river water 87 Sr/ 86 Sr data from 106 sites (1997–2021) to develop spatial stream network models that use dendritic connectivity and watershed characteristics (lithology, bedrock age, and land cover) to predict river water 87 Sr/ 86 Sr throughout the basin. Models were fitted using maximum and restricted likelihood and were evaluated via Akaike’s information criterion and leave-one-out cross validation. We produced both historical (pre-dam) and present-day (below-dam) isoscapes, delineated uncertainty-informed isotopic ranges using k -means clustering, and applied a proof-of-concept Bayesian assignment to estimate natal origins and early rearing habitats for two endangered winter-run Chinook Salmon Oncorhynchus tshawytscha. Results Cross validation indicated strong performance of the 87 Sr/ 86 Sr model (leave-one-out cross validation: R 2 = 0.91; root mean square error = 0.0005). Uncertainty-informed clustering identified 19 isotopic “suites” (reaches with indistinguishable 87 Sr/ 86 Sr values) in present-day anadromous habitats and 25 suites in the historical network. Example natal and early rearing assignments included predictions that challenged expectations for juvenile salmon migration based on predicted river 87 Sr/ 86 Sr compositions. Conclusions This study developed a continuous, network-explicit 87 Sr/ 86 Sr isoscape that integrates existing river data to predict 87 Sr/ 86 Sr in unsampled reaches and the likely achievable range and resolution of otolith-based origin and life history inference. The resulting river isoscape provides a valuable tool to predict salmon movements and identify habitats supporting their survival and growth that otherwise might remain undetected. Coupling these predictions with complementary approaches that ground-truth juvenile presence (e.g., targeted fish surveys) represents an important step toward science-informed restoration and management of critical habitats throughout the Sacramento River basin.

Environmental sciences↗

Applying Infrared Thermography as a Method for Online Monitoring of Turbine Blade Coolant Flow

As gas turbine engine manufacturers strive to implement condition-based operation and maintenance, there is a need for blade monitoring strategies capable of early fault detection and root-cause determination. Given the importance of blade cooling flows to turbine blade health and longevity, there is a distinct lack of methodologies for coolant flowrate monitoring. The present study addresses this identified opportunity by applying an infrared thermography system on an engine-representative research turbine to generate data-driven models for prediction of blade coolant flowrate. Thermal images were used as inputs to a linear regression and regularization algorithm to relate blade surface temperature distribution with blade coolant flowrate. Additionally, this study investigates how coolant flowrate prediction accuracy is influenced by the number and breadth of diagnostic measurements. Here, the results of this study indicate that a source of high-fidelity training data can be used to predict blade coolant flowrate within about six percent error. Furthermore, identification of prioritized sensor placement supports application of this technique across multiple sensor technologies capable of measuring blade surface temperature in operating gas turbine engines, including spatially resolved and point-based measurement techniques.

42 ENGINEERING↗

Phantom-based experimental validation of computational fluid dynamics simulations on cerebral aneurysms

Purpose: Recently, image-based computational fluid dynamics (CFD) simulation has been applied to investigate the hemodynamics inside human cerebral aneurysms. The knowledge of the computed three-dimensional flow fields is used for clinical risk assessment and treatment decision making. However, the reliability of the application specific CFD results has not been thoroughly validated yet. Methods: In this work, by exploiting a phantom aneurysm model, the authors therefore aim to prove the reliability of the CFD results obtained from simulations with sufficiently accurate input boundary conditions. To confirm the correlation between the CFD results and the reality, virtual angiograms are generated by the simulation pipeline and are quantitatively compared to the experimentally acquired angiograms. In addition, a parametric study has been carried out to systematically investigate the influence of the input parameters associated with the current measuring techniques on the flow patterns. Results: Qualitative and quantitative evaluations demonstrate good agreement between the simulated and the real flow dynamics. Discrepancies of less than 15% are found for the relative root mean square errors of time intensity curve comparisons from each selected characteristic position. The investigated input parameters show different influences on the simulation results, indicating the desired accuracy in the measurements. Conclusions: This study provides a comprehensive validation method of CFD simulation for reproducing the real flow field in the cerebral aneurysm phantom under well controlled conditions. The reliability of the CFD is well confirmed. Through the parametric study, it is possible to assess the degree of validity of the associated CFD model based on the parameter values and their estimated accuracy range.

42 ENGINEERING↗

SU-E-J-92: On-Line Cone Beam CT Based Planning for Emergency and Palliative Radiation Therapy

Purpose: To evaluate and develop the feasibility of on-line cone beam CT based planning for emergency and palliative radiotherapy treatments. Methods: Subsequent to phantom studies, a case library of 28 clinical megavoltage cone beam CT (MVCBCT) was built to assess dose-planning accuracies on MVCBCT for all anatomical sites. A simple emergency treatment plan was created on the MVCBCT and copied to its reference CT. The agreement between the dose distributions of each image pair was evaluated by the mean dose difference of the dose volume and the gamma index of the central 2D axial plane. An array of popular urgent and palliative cases was also evaluated for imaging component clearance and field-of-view. Results: The treatment cases were categorized into four groups (head and neck, thorax/spine, pelvis and extremities). Dose distributions for head and neck treatments were predicted accurately in all cases with a gamma index of >95% for 2% and 2 mm criteria. Thoracic spine treatments had a gamma index as low as 60% indicating a need for better uniformity correction and tissue density calibration. Small anatomy changes between CT and MVCBCT could contribute to local errors. Pelvis and sacral spine treatment cases had a gamma index between 90% and 98% for 3%/3 mm criteria. The limited FOV became an issue for large pelvis patients. Imaging clearance was difficult for cases where the tumor was positioned far off midline. Conclusion: The MVCBCT based dose planning and delivery approach is feasible in many treatment cases. Dose distributions for head and neck patients are unrestrictedly predictable. Some FOV restrictions apply to other treatment sites. Lung tissue is most challenging for accurate dose calculations given the current imaging filters and corrections. Additional clinical cases for extremities need to be included in the study to assess the full range of site-specific planning accuracies. This work is supported by Siemens.

60 APPLIED LIFE SCIENCES↗