Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

SU-E-T-790: Validation of 4D Measurement-Guided Dose Reconstruction (MGDR) with OCTAVIUS 4D System

Purpose: To validate the MGDR of OCTAVIUS 4D system (PTW, Freiburg, Germany) for quality assurance (QA) of volumetric-modulated arc radiotherapy (VMAT). Methods: 4D-MGDR measurements were divided into two parts: 1) square fields from 2×2 to 25×25 cm{sup 2} at 0°, 10° and 45° gantry, and 2) 8 VMAT plans (5 nasopharyngeal and 3 prostate) collapsed to gantry 40° in QA mode in Monaco v5.0 (Elekta, CMS, Maryland Heights, MO) were delivered on the OCTAVIUS 4D phantom with the OCTAVIUS 1500 detector plane perpendicular to either the incident beam to obtain the reconstructed dose (OCTA4D) or the 0° gantry axis to obtain the raw doses (OCTA3D) in Verisoft 6.1 (PTW, Freiburg, Germany). Raw measurements of OCTA3D were limited to < 45° gantry to avoid >0.5% variation of detector angular response with respect to 0° gantry as determined previously. Reconstructed OCTA4D and raw OCTA3D doses for all plans were compared at the same detector plane using γ criteria of 2% (local dose)/2mm and 3%/3mm criteria. Results: At gantry 0° and 10°, the γ results for all OCTA4D on detector plane coinciding with OCTA3D were over 90% at 2%/2mm except for the largest field (25×25 cm{sup 2} ) showing >88%. For square field at 45° gantry, γ passing rate is > 90% for fields smaller than 15x 15cm2 but < 80% for field size of 20 x20 cm{sup 2} upward. For VMAT, γ results showed 94% and 99% passing rate at 2%/2mm and 3%/3mm, respectively. Conclusion: OCTAVIUS 4D system has compromised accuracy in reconstructing dose away from the central beam axis, possibly due to the off-axis softening correction and errors of the percent depth dose data necessary as input for MGDR. Good results in VMAT delivery suggested that the system is relatively reliable for VMAT with small segments.

60 APPLIED LIFE SCIENCES↗

A constraint on the formation timescale of the young open cluster NGC 2264: lithium abundance of pre-main sequence stars

The timescale of cluster formation is an essential parameter in order to understand the formation process of star clusters. Pre-main sequence (PMS) stars in nearby young open clusters reveal a large spread in brightness. If the spread were considered to be a result of a real spread in age, the corresponding cluster formation timescale would be about 5–20 Myr. Hence it could be interpreted that star formation in an open cluster is prolonged for up to a few tens of Myr. However, difficulties in reddening correction, observational errors, and systematic uncertainties introduced by imperfect evolutionary models for PMS stars can result in an artificial age spread. Alternatively, we can utilize Li abundance as a relative age indicator of PMS star to determine the cluster formation timescale. The optical spectra of 134 PMS stars in NGC 2264 have been obtained with MMT/Hectochelle. The equivalent widths have been measured for 86 PMS stars with a detectable Li line (3500<T{sub eff}[K]⩽6500). Li abundance under the condition of local thermodynamic equilibrium (LTE) was derived using the conventional curve of growth method. After correction for non-LTE effects, we find that the initial Li abundance of NGC 2264 is A(Li)=3.2±0.2. From the distribution of the Li abundances, the underlying age spread of the visible PMS stars is estimated to be about 3–4 Myr and this, together with the presence of embedded populations in NGC 2264, suggests that the cluster formed on a timescale shorter than 5 Myr.

79 ASTRONOMY AND ASTROPHYSICS↗

The many-body expansion for aqueous systems revisited: II. Alkali metal and halide ion – water interactions

We present a detailed study of the Many-Body Expansion (MBE) for alkali metal and halide ion-water interactions and quantify the effect of these ions on the strength of the surrounding aqueous hydrogen bonding environment. Building on our previous work on neutral water clusters [J. P. Heindel and S. S. Xantheas, J. Chem. Theor. Comput. 16 (11), 6843–6855 (2020)], we carry out the complete MBE for ion-water clusters, Z+/-(H2O)9, where Z = Li+, K+, Cs+, Cl-, Br-, I- and compare with the results for (H2O)10. The 2-B ion-water (I-W) interaction represents a larger percentage of the total cluster binding energy compared to a pure water cluster of the same size with the total 3-B term being smaller and of opposite sign (repulsive) whereas higher order terms are essentially negligible. The same oscillating behavior around zero for MBE terms higher than the 5-B with basis set that was reported for water clusters is also observed for the ion-water clusters considered with Basis Set Superposition Error (BSSE) corrections amending this like in the water cluster case. A remarkable, linear anti-correlation between the total 2-B ion-water and the total 2-B and 3-B water-water interactions is found, quantifying the effect of the different ions in disrupting and altering (weakening) the neighboring hydrogen bonded water network. Our results suggest a universal behavior of the two different families of ions (alkali metals and halides) for both the correlations of the various components of the total binding energies as well as the estimate of the 2-B BSSE correction which is reported to follow a common profile for ion-water and water-water interactions when cast in terms of reduced distances and energies. We expect our insights into the nature of BSSE will be important for future ab initio based, many-body molecular dynamics studies.

ion-water interactions, water-water interaction, m↗

Fixing the reference frame for PPMXL proper motions using extragalactic sources

In this study, we quantify and correct systematic errors in PPMXL proper motions using extragalactic sources from the first two LAMOST data releases and the Vèron-Cetty & Vèron Catalog of Quasars. Although the majority of the sources are from the Vèron catalog, LAMOST makes important contributions in regions that are not well-sampled by previous catalogs, particularly at low Galactic latitudes and in the south Galactic cap. We show that quasars in PPMXL have measurable and significant proper motions, which reflect the systematic zero-point offsets present in the catalog. We confirm the global proper motion shifts seen by Wu et al., and additionally find smaller-scale fluctuations of the QSO-derived corrections to an absolute frame. Finally, we average the proper motions of 158 106 extragalactic objects in bins of 3° × 3° and present a table of proper motion corrections.

79 ASTRONOMY AND ASTROPHYSICS↗

Erratum: A Comparison of Closures for Stochastic Advection-Diffusion Equations

This note corrects an error in the authors' article [SIAM/ASA J. Uncertain. Quantif., 1 (2013), pp. 319 347] in which the cited work [Neuman, Water Resour. Res., 29(3) (1993), pp. 633 645] was incorrectly represented and attributed. Concentration covariance equations presented in our article as new were in fact previously derived in the latter work. In the original abstract, the phrase " . . .we propose a closed-form approximation to two-point covariance as a measure of uncertainty. . ." should be replaced by the phrase " . . .we study a closed-form approximation to two-point covariance, previously derived in [Neuman 1993], as a measure of uncertainty." The primary results in our article--the analytical and numerical comparison of existing closure methods for specific example problems are not changed by this correction.

stochastic PDE↗

Comparing the performance of density functionals in describing the adsorption of atoms and small molecules on Ni(111)

Reaction networks calculated using density functional theory (DFT) play a crucial role in understanding and predicting heterogeneous catalyst performance. However, results obtained using different density functionals can vary significantly. Accordingly, it is important to assess the accuracy of available functionals in capturing adsorption energetics derived from single-crystal adsorption microcalorimetry experiments. Here, we evaluate how different density functionals describe the molecular and dissociative adsorption of CH 3 I, the adsorption of CH 3 , I, and H, and the dissociative adsorption of CH 4 on Ni(111). First, we identify energetically-preferred adsorbed states for each adsorbate at three surface coverages and calculate the corresponding enthalpies of adsorption at 160 K. Then, we compare the results to experimental measurements published in the literature. For each adsorption process we find at least one functional that is quantitatively accurate within experimental error, but no functional is accurate (within experimental error) for all adsorption processes studied. Even when assuming an additional DFT error of ±20 kJ/mol on top of the experimental error, only the PBE-D3 and RPBE-D3 functionals are accurate for all considered adsorption systems. Overall, these results indicate that quantitative agreement between density functional theory calculations and experimental measurements is both system- and functional-dependent. Importantly, single-crystal adsorption microcalorimetry experiments will continue to play an important role for benchmarking density functionals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The dosimetric impact of daily setup error on target volumes and surrounding normal tissue in the treatment of prostate cancer with intensity-modulated radiation therapy

The purpose of this study was to evaluate the impact of daily setup error and interfraction organ motion on the overall dosimetric radiation treatment plans. Twelve patients undergoing definitive intensity-modulated radiation therapy (IMRT) treatments for prostate cancer were evaluated in this institutional review board-approved study. Each patient had fiducial markers placed into the prostate gland before treatment planning computed tomography scan. IMRT plans were generated using the Eclipse treatment planning system. Each patient was treated to a dose of 8100 cGy given in 45 fractions. In this study, we retrospectively created a plan for each treatment day that had a shift available. To calculate the dose, the patient would have received under this plan, we mathematically 'negated' the shift by moving the isocenter in the exact opposite direction of the shift. The individualized daily plans were combined to generate an overall plan sum. The dose distributions from these plans were compared with the treatment plans that were used to treat the patients. Three-hundred ninety daily shifts were negated and their corresponding plans evaluated. The mean isocenter shift based on the location of the fiducial markers was 3.3 {+-} 6.5 mm to the right, 1.6 {+-} 5.1 mm posteriorly, and 1.0 {+-} 5.0 mm along the caudal direction. The mean D95 doses for the prostate gland when setup error was corrected and uncorrected were 8228 and 7844 cGy (p < 0.002), respectively, and for the planning target volume (PTV8100) was 8089 and 7303 cGy (p < 0.001), respectively. The mean V95 values when patient setup was corrected and uncorrected were 99.9% and 87.3%, respectively, for the PTV8100 volume (p < 0.0001). At an individual patient level, the difference in the D95 value for the prostate volume could be >1200 cGy and for the PTV8100 could approach almost 2000 cGy when comparing corrected against uncorrected plans. There was no statistically significant difference in the D35 parameter for the surrounding normal tissue except for the dose received by the penile bulb and the right hip. Our dosimetric evaluation suggests significant underdosing with inaccurate target localization and emphasizes the importance of accurate patient setup and target localization. Further studies are needed to evaluate the impact of intrafraction organ motion, rotation, and deformation on doses delivered to target volumes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Revisiting Competing Paths in Electrochemical CO 2 Reduction on Copper via Embedded Correlated Wavefunction Theory

We re-evaluate two key steps in the mechanism of CO 2 reduction on copper at a higher level of theory capable of correcting inherent errors in density functional theory (DFT) approximations, namely, embedded correlated wavefunction (ECW) theory. Here, we consider the CO reduction step on Cu(111), which is critical to understanding reaction selectivity. Here, we optimize embedding potentials at the periodic plane-wave DFT level using density functional embedding theory (DFET). All possible adsorption sites (adsites) for each adsorbate then are screened with ECW theory at the catalytically active site to refine the local electronic structure. Unsurprisingly, DFT and ECW theory predict different adsite preferences, largely because of DFT’s inability to properly situate the CO 2π* level. Differing preferred adsites suggest that different reaction pathways could emerge from DFT versus ECW theory. Starting from these preferred ECW theory adsites, we then obtain reaction pathways at the plane-wave DFT level using the climbing-image nudged elastic band method to determine minimum energy paths. Thereafter, we perform ECW calculations at the catalytically active site to correct the energetics at each interpolated structure (image) along the reaction pathways. Via this approach, we confirm that the first step in CO reduction via hydrogen transfer on Cu(111) is to form hydroxymethylidyne (*COH) instead of formyl (*CHO). Although the prediction to preferentially form *COH is consistent with that of DFT, the two theories predict quite different structural and mechanistic behaviors, suggesting that verification is needed for other parts of the mechanism of CO 2 reduction, which is the subject of ongoing work.

30 DIRECT ENERGY CONVERSION↗

WE-AB-BRA-08: Correction of Patient Motion in C-Arm Cone-Beam CT Using 3D-2D Registration

Purpose: Intraoperative C-arm cone-beam CT (CBCT) is subject to artifacts arising from patient motion during the fairly long (∼5–20 s) scan times. We present a fiducial free method to mitigate motion artifacts using 3D-2D image registration that simultaneously corrects residual errors in geometric calibration. Methods: A 3D-2D registration process was used to register each projection to DRRs computed from the 3D image by maximizing gradient orientation (GO) using the CMA-ES optimizer. The resulting rigid 6 DOF transforms were applied to the system projection matrices, and a 3D image was reconstructed via model-based image reconstruction (MBIR, which accommodates the resulting noncircular orbit). Experiments were conducted using a Zeego robotic C-arm (20 s, 200°, 496 projections) to image a head phantom undergoing various types of motion: 1) 5° lateral motion; 2) 15° lateral motion; and 3) 5° lateral motion with 10 mm periodic inferior-superior motion. Images were reconstructed using a penalized likelihood (PL) objective function, and structural similarity (SSIM) was measured for axial slices of the reconstructed images. A motion-free image was acquired using the same protocol for comparison. Results: There was significant improvement (p < 0.001) in the SSIM of the motion-corrected (MC) images compared to uncorrected images. The SSIM in MC-PL images was >0.99, indicating near identity to the motion-free reference. The point spread function (PSF) measured from a wire in the phantom was restored to that of the reference in each case. Conclusion: The 3D-2D registration method provides a robust framework for mitigation of motion artifacts and is expected to hold for applications in the head, pelvis, and extremities with reasonably constrained operative setup. Further improvement can be achieved by incorporating multiple rigid components and non-rigid deformation within the framework. The method is highly parallelizable and could in principle be run with every acquisition. Research supported by National Institutes of Health Grant No. R01-EB-017226 and academic-industry partnership with Siemens Healthcare (AX Division, Forcheim, Germany).

60 APPLIED LIFE SCIENCES↗

Improving filtering and prediction of spatially extended turbulent systems with model errors through stochastic parameter estimation

The filtering and predictive skill for turbulent signals is often limited by the lack of information about the true dynamics of the system and by our inability to resolve the assumed dynamics with sufficiently high resolution using the current computing power. The standard approach is to use a simple yet rich family of constant parameters to account for model errors through parameterization. This approach can have significant skill by fitting the parameters to some statistical feature of the true signal; however in the context of real-time prediction, such a strategy performs poorly when intermittent transitions to instability occur. Alternatively, we need a set of dynamic parameters. One strategy for estimating parameters on the fly is a stochastic parameter estimation through partial observations of the true signal. In this paper, we extend our newly developed stochastic parameter estimation strategy, the Stochastic Parameterization Extended Kalman Filter (SPEKF), to filtering sparsely observed spatially extended turbulent systems which exhibit abrupt stability transition from time to time despite a stable average behavior. For our primary numerical example, we consider a turbulent system of externally forced barotropic Rossby waves with instability introduced through intermittent negative damping. We find high filtering skill of SPEKF applied to this toy model even in the case of very sparse observations (with only 15 out of the 105 grid points observed) and with unspecified external forcing and damping. Additive and multiplicative bias corrections are used to learn the unknown features of the true dynamics from observations. We also present a comprehensive study of predictive skill in the one-mode context including the robustness toward variation of stochastic parameters, imperfect initial conditions and finite ensemble effect. Furthermore, the proposed stochastic parameter estimation scheme applied to the same spatially extended Rossby wave system demonstrates high predictive skill, comparable with the skill of the perfect model for a duration of many eddy turnover times especially in the unstable regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inversion-based correction of Double-Torsion (DT) subcritical crack growth tests for crack profile geometry

Because of its simplicity and the ability to produce a stable, slow-propagating crack, the Double-Torsion (DT) method has been used widely for investigating the critical and subcritical propagation of a slow-propagating tensile (mode-I) crack. However, to determine the complex relationship between the crack velocity $\mathcal{v_c}$ vs. the strain energy release rate $\mathscr{G}$ (or the stress intensity factor K) from laboratory measurements, several corrections must be made to account for the impact of sample and crack geometry. Particularly, DT test typically produces a crack with a curved edge profile instead of a straight line, causing the local $\mathcal{v_c}$ and $\mathscr{G}$ vary along the crack front. The experimentally measured $\mathcal{v_c}$ and $\mathscr{G}$ data merely reflect collective, averaged behavior of the crack. This makes inversion for the intrinsic, “true” crack growth kinetics necessary, based upon the knowledge of the crack geometry. Simple and effective correction methods have been proposed and validated for the slow, chemical-reaction-controlled part (Region I) of the $\mathcal{v_c}$-$\mathscr{G}$ curve. However, reliable methods for the highly nonlinear, transport-dominated part (Region II) and its sudden transition to the dynamic propagation part (Region III) are still lacking. Here we propose a method for determining the intrinsic $\mathcal{v_c}$-$\mathscr{G}$ relationship across all three Regions based upon DT test data, using a simple model function and its numerical inversion. The performance of this approach is examined and demonstrated using both synthetic and laboratory data for subcritical crack growth in soda lime glass.

42 ENGINEERING↗

WE-AB-BRA-09: Sensitivity of Plan Re-Optimization to Errors in Deformable Image Registration in Online Adaptive Image-Guided Radiation Therapy

Purpose: Online adaptive therapy (ART) relies on auto-contouring using deformable image registration (DIR). DIR’s inherent uncertainties require user intervention and manual edits while the patient is on the table. We investigated the dosimetric impact of DIR errors on the quality of re-optimized plans, and used the findings to establish regions for focusing manual edits to where DIR errors can Result in clinically relevant dose differences. Methods: Our clinical implementation of online adaptive MR-IGRT involves using DIR to transfer contours from CT to daily MR, followed by a physicians’ edits. The plan is then re-optimized to meet the organs at risk (OARs) constraints. Re-optimized abdomen and pelvis plans generated based on physician edited OARs were selected as the baseline for evaluation. Plans were then re-optimized on auto-deformed contours with manual edits limited to pre-defined uniform rings (0 to 5cm) around the PTV. A 0cm ring indicates that the auto-deformed OARs were used without editing. The magnitude of the variations caused by the non-deterministic optimizer was quantified by repeat re-optimizations on the same geometry to determine the mean and standard deviation (STD). For each re-optimized plan, various volumetric parameters for the PTV, the OARs were extracted along with DVH and isodose evaluation. A plan was deemed acceptable if the variation from the baseline plan was within one STD. Results: Initial results show that for abdomen and pancreas cases, a minimum of 5cm margin around the PTV is required for contour corrections, while for pelvic and liver cases a 2–3 cm margin is sufficient. Conclusion: Focusing manual contour edits to regions of dosimetric relevance can reduce contouring time in the online ART process while maintaining a clinically comparable plan. Future work will further refine the contouring region by evaluating the path along the beams, dose gradients near the target and OAR dose metrics.

60 APPLIED LIFE SCIENCES↗

Silicon Damage Response Function Derivation and Verification: Assessment of Impact on ASTM Standard E722

Unsuccessful attempts by members of the radiation effects community to independently derive the Norgett-Robinson-Torrens (NRT) damage energy factors for silicon in ASTM standard E722-14 led to an investigation of the software coding and data that produced those damage energy factors. The ad hoc collaboration to discover the reason for lack of agreement revealed a coding error and resulted in a report documenting the methodology to produce the response function for the standard. The recommended changes in the NRT damage energy factors for silicon are shown to have significant impact for a narrow energy region of the 1-MeV(Si) equivalent fluence response function. However, when evaluating integral metrics over all neutrons energies in various spectra important to the SNL electronics testing community, the change in the response results in a small decrease in the total 1- MeV(Si) equivalent fluence of ~0.6% compared to the E722-14 response. Response functions based on the newly recommended NRT damage energy factors have been produced and are available for users of both the NuGET and MCNP codes.

36 MATERIALS SCIENCE↗

Fast BPM data distribution for global orbit feedback using commercial gigabit ethernet technology

In order to correct beam perturbations in RHIC around 10Hz, a new fast data distribution network was required to deliver BPM position data at rates several orders of magnitude above the capability of the existing system. The urgency of the project limited the amount of custom hardware that could be developed, which dictated the use of as much commercially available equipment as possible. The selected architecture uses a custom hardware interface to the existing RHIC BPM electronics together with commercially available Gigabit Ethernet switches to distribute position data to devices located around the collider ring. Using the minimum Ethernet packet size and a field programmable gate array (FPGA) based state machine logic instead of a software based driver, real-time and deterministic data delivery is possible using Ethernet. The method of adapting this protocol for low latency data delivery, bench testing of Ethernet hardware, and the logic to construct Ethernet packets using FPGA hardware will be discussed. A robust communications system using almost all commercial off-the-shelf equipment was developed in under a year which enabled retrofitting of the existing RHIC BPM system to provide 10 KHz data delivery for a global orbit feedback scheme using 72 BPMs. Total latencies from data acquisition at the BPMs to delivery at the controller modules, including very long transmission distances, were kept under 100 {micro}s, which provide very little phase error in correcting the 10 Hz oscillations. Leveraging off of the speed of Gigabit Ethernet and wide availability of Ethernet products enabled this solution to be fully implemented in a much shorter time and at lower cost than if a similar network was developed using a proprietary method.

43 PARTICLE ACCELERATORS↗

Protected gates for topological quantum field theories

We study restrictions on locality-preserving unitary logical gates for topological quantum codes in two spatial dimensions. A locality-preserving operation is one which maps local operators to local operators — for example, a constant-depth quantum circuit of geometrically local gates, or evolution for a constant time governed by a geometrically local bounded-strength Hamiltonian. Locality-preserving logical gates of topological codes are intrinsically fault tolerant because spatially localized errors remain localized, and hence sufficiently dilute errors remain correctable. By invoking general properties of two-dimensional topological field theories, we find that the locality-preserving logical gates are severely limited for codes which admit non-abelian anyons, in particular, there are no locality-preserving logical gates on the torus or the sphere with M punctures if the braiding of anyons is computationally universal. Furthermore, for Ising anyons on the M-punctured sphere, locality-preserving gates must be elements of the logical Pauli group. We derive these results by relating logical gates of a topological code to automorphisms of the Verlinde algebra of the corresponding anyon model, and by requiring the logical gates to be compatible with basis changes in the logical Hilbert space arising from local F-moves and the mapping class group.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diagnosing and Correcting Mass Accuracy and Signal Intensity Error Due to Initial Ion Position Variations in a MALDI TOFMS

Frustrated by worse than expected error for both peak area and time-of-flight (TOF) in matrix assisted laser desorption ionization (MALDI) experiments using samples prepared by electrospray deposition, it was finally determined that there was a correlation between sample location on the target plate and the measured TOF/peak area. Variations in both TOF and peak area were found to be due to small differences in the initial position of ions formed in the source region of the TOF mass spectrometer. These differences arise largely from misalignment of the instrument sample stage, with a smaller contribution arising from the non-ideal shape of the target plates used. By physically measuring the target plates used and comparing TOF data collected from three different instruments, an estimate of the magnitude and direction of the sample stage misalignment was determined for each of the instruments. A correction method was developed to correct the TOFs and peak areas obtained for a given combination of target plate and instrument. Two correction factors are determined, one by initially collecting spectra from each sample position used and another by using spectra from a single position for each set of samples on a target plate. For TOF and mass values, use of the correction factor reduced the error by a factor of 4, with the relative standard deviation (RSD) of the corrected masses being reduced to 12-24 ppm. For the peak areas, the RSD was reduced from 28% to 16% for samples deposited twice onto two target plates over two days. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral deferred correction methods for high-order accuracy in poroelastic problems

In this work, we investigate high-order accuracy in time integration by examining two operator splitting methods for poroelastic problems: the two-pass and the spectral deferred correction (SDC) methods. To enhance the order of accuracy, the two-pass method partitions a coupled operator symmetrically, whereas the SDC method corrects truncation errors by establishing an error equation. These high-order methods are applied to underlying solution strategies, i.e., monolithic, fixed-stress sequential, and undrained sequential methods. We observe that semi-discretized systems from spatial discretization have forms similar to those of index-1 differential algebraic equations (DAEs), causing order reduction against the two-pass method when it is used in conjunction with either the monolithic or sequential method. On the other hand, the SDC in conjunction with the monolithic method exhibits the desired second-order accuracy in poroelastic problems while increasing the order of accuracy for index-1 DAEs. However, the SDC in conjunction with either of the two sequential methods does not achieve the desired order of accuracy, and maintains first order because the flow equation for poroelasticity has an additional approximation associated with the volumetric strain rate term, which does not yield exactly the same forms as those of conventional DAEs. Thus, the monolithic SDC method can achieve higher-order accuracy, but may require higher computational costs because it involves solving matrix systems larger than those for the sequential methods.

02 PETROLEUM↗

The connected wedge theorem and its consequences

In the AdS/CFT correspondence, bulk causal structure has consequences for boundary entanglement. In quantum information science, causal structures can be replaced by distributed entanglement for the purposes of information processing. In this work, we deepen the understanding of both of these statements, and their relationship, with a number of new results. Centrally, we present and prove a new theorem, the n-to-n connected wedge theorem, which considers n input and n output locations at the boundary of an asymptotically AdS 2+1 spacetime described by AdS/CFT. When a sufficiently strong set of causal connections exists among these points in the bulk, a set of n associated regions in the boundary will have extensive-in-N mutual information across any bipartition of the regions. The proof holds in three bulk dimensions for classical spacetimes satisfying the null curvature condition and for semiclassical spacetimes satisfying standard conjectures. The n-to-n connected wedge theorem gives a precise example of how causal connections in a bulk state can emerge from large-N entanglement features of its boundary dual. It also has consequences for quantum information theory: it reveals one pattern of entanglement which is sufficient for information processing in a particular class of causal networks. We argue this pattern is also necessary, and give an AdS/CFT inspired protocol for information processing in this setting. Our theorem generalizes the 2-to-2 connected wedge theorem proven in [3]. We also correct some errors in the proof presented there, in particular a false claim that existing proof techniques work above three bulk dimensions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗