Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Ir-192 radioisotope replacement with a hand-portable 1 MeV Ku-band electron linear accelerator

Although linear accelerators are used in many security, industrial and medical applications, the existing technologies are too large and expensive for several critical applications such as radioactive source replacement, field radiography and mobile cargo scanners. Here, one of the main requirements for these sources is to be highly portable to allow field operation. In response to this problem, RadiaBeam has designed a hand-portable 1 MeV X-ray source, scalable to higher energies, based on Ku-band split electron linac, that can be used for Ir-192 radioisotope replacement. In this paper, we present its multiphysics and engineering design studies, as well as an accelerating structure prototype along with RF measurements.

43 PARTICLE ACCELERATORS↗

Constraints on the electron-hole pair creation energy and Fano factor below 150 eV from Compton scattering in a Skipper-CCD

Fully-depleted thick silicon Skipper-charge-coupled devices (Skipper-CCDs) have achieved sub-electron read-out noise and are an important technology to probe neutrino and light dark matter interactions. However, the successful search for rare neutrino or dark-matter events requires the signal and all backgrounds to be fully characterized. In particular, a measurement of the electron-hole pair creation energy below 150 eV and the Fano factor are necessary for characterizing the dark matter and neutrino signals. Moreover, photons from background radiation may Compton scatter in the silicon bulk, producing events that can mimic a dark matter or neutrino signal. We present a measurement of the Compton spectrum using a Skipper-CCD and a $^{241}$Am source. With these data, we measure the electron-hole pair-creation energy to be $\left(3.71 \pm 0.08\right)$ eV at 130 K in the energy range between 99.3 eV and 150 eV. By measuring the widths of the steps at 99.3 eV and 150 eV in the Compton spectrum, we introduce a novel technique to measure the Fano factor, setting an upper limit of 0.31 at 90% C.L. These results prove the potential of Skipper-CCDs to characterize the Compton spectrum and to measure precisely the Fano factor and electron-hole pair creation energy below 150 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-controlled direct laser acceleration enabled by longitudinal variation of the laser-driven quasi-static plasma magnetic field

Direct laser acceleration (DLA) enables energy transfer from an ultra-high-intensity laser to plasma electrons and underpins many laser-driven particle and radiation-source concepts. A laser-driven azimuthal plasma magnetic field is a key player in this process: it confines energetic electrons, induces betatron oscillations, and makes possible a resonant interaction between the betatron motion and the laser field. While this betatron resonance can enhance electron energy gain, the gain itself generally drives frequency detuning and promotes largely reversible energy exchange that limits net acceleration. Here we show, using a test-electron model with prescribed fields, that a slow longitudinal increase of the quasi-static plasma magnetic field qualitatively changes DLA by introducing hysteresis in the ratio of the betatron frequency to the laser frequency experienced by the electron, so that this ratio depends on the prior evolution of the electron even at the same energy. This hysteresis enables phase control of the electron-laser energy exchange and suppresses the usual reversibility of DLA, allowing electrons to retain the acquired energy and sustain energy gain without intermittent losses.

direct laser acceleration↗

The Linac Extension Area at the Advanced Photon Source

The Linac Extension Area has been developed into a beamline area for testing accelerator components and techniques. Beginning commissioning activities in February 2023, we have delivered the first electron beam to the Linac Extension Area at the Advanced Photon Source at 425 MeV. In the present work, we summarise the principal accelerator components and review safety controls of the Linac Extension Area.

47 OTHER INSTRUMENTATION↗

Simulation of DIII-D disruption with argon pellet injection and runaway electron beam

Abstract The next generation of large tokamaks, including ITER, will be equipped with a disruption mitigation system (DMS) that can be activated if a disruption is deemed to be imminent. Introducing impurities by pellet (large or shattered) or massive gas injection has been shown to be an effective mitigation mechanism on many tokamaks. The goal of the mitigation is to lessen the thermal and electromagnetic loads from the disruption without generating enough high-energy (runaway) electrons to damage the device. Variations of this mitigation process with impurity injection are presently being tested on many experiments. We have modeled one such impurity injection experiment on DIII-D using the M3D-C1 nonlinear 3D extended MHD code (Jardin et al 2012 Comput. Sci. Discovery 6 014002), The model includes an argon large pellet injection and ablation model, impurity ionization, recombination, and radiation, and runaway electron formation and subsequent evolution, including both Dreicer and avalanche sources. We obtain reasonable agreement with the experimental results for the timescale of the thermal and current quench and for the magnitude of the runaway electron plateau formed during the mitigation. This is the first 3D full MHD simulation with pellets and REs to simulate the disruption process and it also provides a partial validation of the M3D-C1 DMS model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stochastic Averaging of Radiative Transfer Coefficients for Relativistic Electrons

Abstract Synchrotron emissivities, absorptivities, and Faraday rotation and conversion coefficients are needed in modeling a variety of astrophysical sources, including Event Horizon Telescope (EHT) sources. We develop a method for estimating transfer coefficients that exploits their linear dependence on the electron distribution function, decomposing the distribution function into a sum of parts each of whose emissivity can be calculated easily. We refer to this procedure as stochastic averaging and apply it in two contexts. First, we use it to estimate the emissivity of an isotropicκdistribution function with a high-energy cutoff. The resulting coefficients can be evaluated efficiently enough to be used directly in ray-tracing calculations, and we provide an example calculation. Second, we use stochastic averaging to assess the effect of subgrid turbulence on the volume-averaged emissivity and along the way provide a prescription for a turbulent emissivity. We find that for parameters appropriate to EHT sources turbulence reduces the emissivity slightly. In the infrared, turbulence can dramatically increase the emissivity.

Astronomy & Astrophysics↗

Diffraction enhanced imaging utilizing a laser produced x-ray source

Image formation by Fresnel diffraction utilizes both absorption and phase-contrast to measure electron density profiles. The low spatial and spectral coherence requirements allow the technique to be performed with a laser-produced x-ray source coupled with a narrow slit. This makes it an excellent candidate for probing interfaces between materials at extreme conditions, which can only be generated at large-scale laser or pulsed power facilities. Here, we present the results from a proof-of-principle experiment demonstrating an effective ~2 μm laser-generated source at the OMEGA Laser Facility. This was achieved using slits of 1 × 30 μm 2 and 2 × 40 μm 2 geometry, which were milled into 30 μm thick Ta plates. Combining these slits with a vanadium He-like 5.2 keV source created a 1D imaging system capable of micrometer-scale resolution. The principal obstacles to achieving an effective 1 μm source are the slit tilt and taper—where the use of a tapered slit is necessary to increase the alignment tolerance. We demonstrate an effective source size by imaging a 2 ± 0.2 μm radius tungsten wire.

3D printing↗

On possibility of low-emittance high-energy muon source based on plasma wakefield acceleration

We report plasma wakefield acceleration (PWA) channels are characterized by very high accelerating gradients and very strong focusing fields. We propose to employ these properties for effective production of low emittance high energy muon beams, consider muon beam dynamics in the PWFA cell and analyze various options and potential of the PWA-based muon sources.

43 PARTICLE ACCELERATORS↗

Electrochemical CO2 conversion to formic acid through the Andora Process

Electrochemical utilization or conversion of CO2 can be used to convert waste CO2 into targeted high-value and cost-effective commercial products. Conventional processes for CO2 conversion to fuel sources are challenging and expensive due to their requirement for high temperatures and pressures. Electrochemically, a catalyst can be used at a fixed applied potential to reduce CO2 to form a desired product with less competition at modest operating conditions. Formic acid (FA) has recently become a product of interest for CO2 conversion due to its potential for hydrogen storage and fuel cell applications. Electrochemically, FA is produced through a direct two-electron transfer process involving CO2 with a proton source, requiring less energy input and fewer reaction steps than traditional processes. However, there remain significant obstacles for the broader-scale implementation of CO2 on the market, including competition with unwanted CO and H, the presence of molecular oxygen, and stability of the electrocatalyst. In order to overcome some of these challenges, a new continuous flow Andora Process was developed consisting of two separate cells to decouple electrochemical reduction of the charge carrier with the FA production via an engineered catalyst. Recent experimental results show that with appropriate design changes and operating conditions to the flow system, FA production above 500 mM can be achieved along with efficiencies above 80%. TEA and LCA assessments of the Andora Process show a potential for the reduction in the GWP potential and cost saving compared to the current comparative formic acid production process.

60 APPLIED LIFE SCIENCES↗

Revealing electronic state-switching at conical intersections in alkyl iodides by ultrafast XUV transient absorption spectroscopy

Conical intersections between electronic states often dictate the chemistry of photoexcited molecules. Recently developed sources of ultrashort extreme ultraviolet (XUV) pulses tuned to element-specific transitions in molecules allow for the unambiguous detection of electronic state-switching at a conical intersection. Here, the fragmentation of photoexcited iso-propyl iodide and tert-butyl iodide molecules (i-C 3 H 7 I and t-C 4 H 9 I) through a conical intersection between 3 Q 0 / 1 Q 1 spin-orbit states is revealed by ultrafast XUV transient absorption measuring iodine 4d core-to-valence transitions. The electronic state-sensitivity of the technique allows for a complete mapping of molecular dissociation from photoexcitation to photoproducts. In both molecules, the sub-100 fs transfer of a photoexcited wave packet from the 3 Q 0 state into the 1 Q 1 state at the conical intersection is captured. The results show how differences in the electronic state-switching of the wave packet in i-C 3 H 7 I and t-C 4 H 9 I directly lead to differences in the photoproduct branching ratio of the two systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward a long-lifetime polarized photoelectron gun for the Ce+BAF positron source

The addition of spin-polarized, continuous-wave (c.w.) positron beams to the 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF) would provide a significant capability to the experimental nuclear physics program at Jefferson Lab. Based on bremsstrahlung and pair-production in a high-Z target, the positron source requires a 120 MeV spin-polarized c.w. electron beam of several milliamperes. While the beam dynamics of the high-current electron beam are tenable, sustaining this current for weeks of user operations requires an unprecedented charge lifetime from a high-polarization GaAs-based photocathode. A promising approach to exceed the kilocoulomb charge lifetime barrier is reducing the ion back-bombardment fluence at the photocathode. By increasing the laser size and managing the emittance growth with an adequate cathode/anode design, significantly enhanced charge lifetime may be achieved. Based upon a new simulation model that qualitatively explains the lifetime data previously measured at different spot sizes, we describe the practical implications on the parameter space available for a kilocoulomb-lifetime polarized photogun design.

Bruker, M.↗

Toward a long-lifetime polarized photoelectron gun for the Ce+BAF positron source

The addition of spin-polarized, continuous-wave (c.w.) positron beams to the 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF) would provide a significant capability to the experimental nuclear physics program at Jefferson Lab. Based on bremsstrahlung and pair-production in a high-Z target, the positron source requires a 120 MeV spin-polarized c.w. electron beam of several milliamperes. While the beam dynamics of the high-current electron beam are tenable, sustaining this current for weeks of user operations requires an unprecedented charge lifetime from a high-polarization GaAs-based photocathode. A promising approach to exceed the kilocoulomb charge lifetime barrier is reducing the ion back-bombardment fluence at the photocathode. By increasing the laser size and managing the emittance growth with an adequate cathode/anode design, significantly enhanced charge lifetime may be achieved. Based upon a new simulation model that qualitatively explains the lifetime data previously measured at different spot sizes, we describe the practical implications on the parameter space available for a kilocoulomb-lifetime polarized photogun design.

Bruker, M.↗

DC Cryogenic Modeling of Open-Source SkyWater 130 nm MOSFETs at 77 K Using BSIM4

Cryogenic applications in high-energy physics (HEP) demand reliable, low-power CMOS electronics capable of operating at liquid nitrogen temperatures (77 K). The open-source SkyWater 130nm (SKY130) CMOS process has previously been shown to operate at temperatures as low as 4 K making it a promising candidate for HEP applications. In this work, we characterize and model SKY130 low-threshold voltage transistors at 77 K, which is a temperature commonly used in modeling applications for liquid argon detectors. DC characteristic measurements were performed at both room temperature and liquid nitrogen temperature. We created a cryogenic modeling approach to produce a SPICE-compatible, isothermal BSIM4-based model for select transistor sizes at 77 K. The resulting model agrees with data at 77 K with an average error on the order of 20% (relative RMS) and shows no dependence on drain voltage. Due to the open-source nature of SKY130, we have made our models publicly available on Github. We hope this work will continue the trend for democratizing circuit design at cryogenic temperatures in high-energy physics by enabling open access to accurate cryogenic CMOS device models at 77 K.

Beall, F. [Texas U., Arlington]↗

In-Situ Observation of the Formation of Laser-Induced Periodic Surface Structures with Extreme Spatial and Temporal Resolution

Irradiation of solid surfaces with intense ultrashort laser pulses represents a unique way of depositing energy into materials. It allows to realize states of extreme electronic excitation and/or very high temperature and pressure and to drive materials close to and beyond fundamental stability limits. As a consequence, structural changes and phase transitions often occur along unusual pathways and under strongly nonequilibrium conditions. Furthermore, due to the inherent multiscale nature—both temporally and spatially—of these irreversible processes, their direct experimental observation requires techniques that combine high temporal resolution with the appropriate spatial resolution and the capability to obtain good quality data on a single pulse/event basis. In this respect, fourth-generation light sources, namely, short wavelength and short pulse free electron lasers (FELs), are offering new and fascinating possibilities. As an example, this chapter will discuss the results of scattering experiments carried out at the FLASH free electron laser at DESY (Hamburg, Germany), which allowed us to resolve laser-induced structure formation at surfaces on the nanometer to submicron length scale and in temporal regimes ranging from picoseconds to several nanoseconds with sub-picosecond resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bistable Optical Semiconductor Switching Based on C-Doped GaN

Highly resistive gallium nitride (GaN) is an essential material for power optoelectronic applications. While carbon doping is widely used to achieve semi-insulating properties in GaN, the persistent photoconductivity (PPC) arising from deep-level defect traps remains a major obstacle for high-speed power switching. This study demonstrates a novel approach: leveraging the ultrahigh photoresponsivity of GaN:C (up to 2.1 A ⋅ cm/W ⋅ kV, surpassing alternatives such as GaN:Fe) and employing defect-selective optical control to effectively quench the PPC. By synchronizing a short infrared (1064 nm) quenching pulse with UV (385 nm) excitation in an epitaxially grown GaN:C layer on a heavily doped n-type GaN substrate, we achieve a dramatic reduction in photocurrent fall time by approximately 293× (from 470 to 1.6 μ s), increasing modulation bandwidth from 745 Hz to nearly 218 kHz. Here, this advancement not only establishes a new pathway for controlling PPC in GaN:C but also enables the practical integration of GaN:C in fast power switching devices. Enhanced modulation bandwidth, along with GaN:C excellent photoresponsivity, makes it a promising candidate for optically controlled high-voltage, high-power electronic systems, such as photoconductive semiconductor switches (PCSSs) used in pulsed-power drivers, high-power microwave (HPM) sources, and high-voltage gate drivers for wide bandgap (WBG) power electronics.

Carbon-dopped Gallium nitride (GaN:C)↗

Irradiation of Sintered Mo Disks with Presence of Organic Impurities in He Gas Flow

Argonne National Laboratory (Argonne) is assisting NorthStar Medical Technologies in the development of a domestic supply of 99 Mo. Specifically, the present study focuses on the production of 99 Mo-feed solution used by the RadioGenix™ 99m Tc generator. During the target-irradiation phase of production, impurities can potentially be introduced into the feed, and can lead to disturbance of ligand- 99m Tc complexation chemistry and contamination of the final radiopharmaceutical that directly interacts with the patient. To address this issue, Argonne performed irradiations and chemical processing to identify whether the potential contamination of He flow with hydrocarbon oil during irradiation affects the radiochemical purity of the final K 2 MoO 4 (K 2 TcO 4 ) in 5M KOH solution. To mimic the conditions of real irradiation at NorthStar, Argonne used its electron linear accelerator and Van de Graaff facilities, heated the target and oil source to >800°C, and controlled oxygen in the presence of He during irradiation. Following irradiation, scanning electron microscopy (SEM) and carbon analysis (CA) were used to detect carbon contamination on the solid targets. The radiochemical purity of the dissolved targets was studied via thin-layer paper chromatography (TLC). As a result of these experiments, small regions of the surface of some irradiated disks were found to be high in carbon, but the total carbon content was still negligible in comparison to the reference sample, which had experienced no irradiation or contact with oil. The summarized results from the SEM, CA, and TLC tests lead to the conclusion that even an excess of oil and heating during irradiation do not affect the radiochemical purity of the final product.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterizing electron-collecting CdTe for use in a 77 ns burst-rate imager

The Keck-PAD (pixel array detector) was developed at Cornell as a burst-rate imager capable of recording images from successive electron bunches (153 ns period) from the Advanced Photon Source (APS). Both Si and hole-collecting Schottky CdTe have been successfully bonded to this ASIC (application-specific integrated circuit) and used with this frame rate. The facility upgrades at the APS will lower the bunch period to 77 ns, which will require modifications to the Keck-PAD electronics to image properly at this reduced period. In addition, operation at high X-ray energies will require a different sensor material having a shorter charge collection time. For the target energy of 40 keV for this project, simulations have shown that electron-collecting CdTe should allow >90% charge collection within 35 ns. This collection time will be sufficient to sample the signal from one frame and prepare for the next. 750 µm-thick electron-collecting Schottky CdTe has been obtained from Acrorad and bonded to two different charge-integrating ASICs developed at Cornell, the Keck-PAD and the CU-APS-PAD. Carrier mobility has been investigated using the detector response to single X-ray bunches at the Cornell High Energy Synchrotron Source and to a pulsed optical laser. The tests indicate that the collection time will meet the requirements for 77 ns imaging.

36 MATERIALS SCIENCE↗