Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Refined Synthesis and Characterization of Controlled Diameter, Narrow Size Distribution Microparticles for Aerospace Research Applications

Flow visualization using polystyrene microspheres (PSL)s has enabled researchers to learn a tremendous amount of information via particle based diagnostic techniques. To better accommodate wind tunnel researchers needs, PSL synthesis via dispersion polymerization has been carried out at NASA Langley Research Center since the late 1980s. When utilizing seed material for flow visualization, size and size distribution are of paramount importance. Therefore, the work described here focused on further refinement of PSL synthesis and characterization. Through controlled variation of synthetic conditions (chemical concentrations, solution stirring speed, temperature, etc.) a robust, controllable procedure was developed. The relationship between particle size and salt concentration, MgSO4, was identified enabling the determination of PSL diameters a priori. Suggestions of future topics related to PSL synthesis, stability, and size variation are also described.

Tiemsin, Pacita I.↗

Performance Evaluation of Peer-to-Peer Distributed Microgrids Coordination for Voltage Regulation

This paper presents the performance evaluation of a peer-to-peer microgrids coordination algorithm for sub-transmission systems. As distributed energy resources (DERs) in distribution system start to show negative impact to the bulk power system, a paradigm shift is needed for transmission planning and operation. Because distribution substations are located far from the sub-transmission system, and it is hard to use traditional centralized control for real-time control and coordination. Thus, distributed control is a natural choice because it requires less communication and central computation. In this paper, each distribution substation is treated as a microgrid, and the peer-to-peer distributed microgrids control is formulated as a real-time optimal power flow problem to reduce the negative impact in sub-transmission systems. A distributed primal-dual optimization algorithm is adopted to solve the problem. Validation of the peer-to-peer algorithm is performed through the simulation of a real-world sub-transmission system composing of many distribution systems with high renewable penetration. Simulation results show that the peer-to-peer algorithm can achieve satisfactory performance (e.g., voltage regulation) in sub-transmission system by coordinating and controlling DERs in distribution systems.

distributed control↗

Performance Evaluation of Peer-to-Peer Distributed Microgrids Coordination for Voltage Regulation: Preprint

This paper presents the performance evaluation of a peer-to-peer microgrids coordination algorithm for sub-transmission systems. As distributed energy resources (DERs) in distribution system start to show negative impact to the bulk power system, a paradigm shift is needed for transmission planning and operation. Because distribution substations are located far from the sub-transmission system, and it is hard to use traditional centralized control for real-time control and coordination. Thus, distributed control is a natural choice because it requires less communication and central computation. In this paper, each distribution substation is treated as a microgrid, and the peer-to-peer distributed microgrids control is formulated as a real-time optimal power flow problem to reduce the negative impact in sub-transmission systems. A distributed primal-dual optimization algorithm is adopted to solve the problem. Validation of the peer-to-peer algorithm is performed through the simulation of a real-world sub-transmission system composing of many distribution systems with high renewable penetration. Simulation results show that the peer-to-peer algorithm can achieve satisfactory performance (e.g., voltage regulation) in sub-transmission system by coordinating and controlling DERs in distribution systems.

distributed control↗

Space Shuttle Upgrades Advanced Hydraulic Power System

Three Auxiliary Power Units (APU) on the Space Shuttle Orbiter each provide 145 hp shaft power to a hydraulic pump which outputs 3000 psi hydraulic fluid to 41 hydraulic actuators. A hydrazine fuel powered APU utilized throughout the Shuttle program has undergone many improvements, but concerns remain with flight safety, operational cost, critical failure modes, and hydrazine related hazards. The advanced hydraulic power system (AHPS), also known as the electric APU, is being evaluated as an upgrade to replace the hydrazine APU. The AHPS replaces the high-speed turbine and hydrazine fuel supply system with a battery power supply and electric motor/pump that converts 300 volt electrical power to 3000 psi hydraulic power. AHPS upgrade benefits include elimination of toxic hydrazine propellant to improve flight safety, reduction in hazardous ground processing operations, and improved reliability. Development of this upgrade provides many interesting challenges and includes development of four hardware elements that comprise the AHPS system: Battery - The battery provides a high voltage supply of power using lithium ion cells. This is a large battery that must provide 28 kilowatt hours of energy over 99 minutes of operation at 300 volts with a peak power of 130 kilowatts for three seconds. High Voltage Power Distribution and Control (PD&C) - The PD&C distributes electric power from the battery to the EHDU. This 300 volt system includes wiring and components necessary to distribute power and provide fault current protection. Electro-Hydraulic Drive Unit (EHDU) - The EHDU converts electric input power to hydraulic output power. The EHDU must provide over 90 kilowatts of stable, output hydraulic power at 3000 psi with high efficiency and rapid response time. Cooling System - The cooling system provides thermal control of the Orbiter hydraulic fluid and EHDU electronic components. Symposium presentation will provide an overview of the AHPS upgrade, descriptions of the four hardware elements, and a summary of development results to date.

Source record↗

Distributed microprocessors for spacecraft control and data handling

The Unified Data System (UDS) group at JPL is attempting to reduce total mission costs by designing a spacecraft data system which takes advantage of the natural and historical partitioning of a spacecraft into subsystems. Each subsystem is assigned a microprocessor which needs just enough capability to control the sensors and actuators of that subsystem, collect its data and maintain time synchronization with the rest of the spacecraft. The resulting distributed system avoids many of the overhead costs of a single centralized multi-processing system. To minimize complexity and therefore minimize total mission costs, a variety of standards and restrictions are imposed on the design of hardware, software, and communications. Articulation of these standards and restrictions is a major benefit deriving from the UDS program.

Lesh, F.↗

Communication-Constrained Robust Control and Learning of Grid-Connected

The electric grid of things (EGoT) promises great potential for innovative grid services by tapping into vast load flexibility. However, the unique characteristics of EGoT, being a part of the cyber-physical electric power system, present both opportunities and challenges, especially concerning supply-demand balancing, stability, and communication constraints. Traditionally, centralized control was employed to ensure balance and stability in power systems. However, with the massive influx of EGoT devices, new strategies are needed to efficiently coordinate and control these distributed devices for optimal grid operations. While some studies have explored efficiency and economic models, there remains a gap in ensuring reliability under everyday operations and resilience during extreme conditions. Addressing this gap, this project develops the technology for an Energy Service Interface (ESI) that includes novel pricing, control, learning, and distributed optimization algorithms, which will enable utilities to recruit EGoT assets for crucial grid services such as load flexibility, voltage regulation, and situation-awareness. The key novelty of the proposed technology is the careful distribution of learning and control functions across utility and EGoT asset owners such that provably efficient and resilient grid operations are attained while respecting communication and information-exchange constraints. Specifically, the project team develops machine-learning enhanced load modeling methods to allow EGoT asset owners to learn their load capability and flexibility, and develops pricing-based and decentralized learning-based control so that asset owners can coordinate to meet system-wide demand-supply balance and reliability goals. For extreme situations involving high-impact, low-probability catastrophic events (termed the “black-sky” events), the team also develops (1) a “Feeder-Operating Center-on-a-Laptop” (FOCAL) software that can assist utility personnel in leveraging EGoT assets to accelerate the service recovery of damaged feeders, and (2) distributed optimization algorithms that can coordinate the operation points of EGoT devices under severe communication constraints. The proposed technology has been extensively tested and evaluated through simulations and on a testbed. In summary, as we transition into a more interconnected and digital power grid era, our project’s findings and developments offer a pivotal step toward guaranteeing both efficiency and resilience in the face of both everyday operations and rare “black-sky” events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchically porous electrospun carbon nanofiber for high-rate capacitive deionization electrodes

Capacitive deionization (CDI) is a promising technology that has gained interest for the desalination of brackish water. Hierarchically porous carbons are commonly used as electrodes for CDI due to their high surface areas and controlled pore size distributions that maximize ion adsorption capacity and rate. Electrospinning is an effective way of generating carbon nanofibers with high inter-fiber macroporosity that can be further modified to improve surface area, total pore volume, and pore size distribution. This work describes the use of sacrificial mesopore formers in tandem with a micropore etching technique to induce hierarchical porosity in electrospun fibers. Mesopores are formed via the dissolution of silica nanoparticles that are introduced into the fibers during the electrospinning step. After mesopore formation, micropores are etched into the resulting surface through KOH impregnation and thermal activation. This sequential technique creates a hierarchical network of pores from the inherent macroporosity of the fiber network, to the mesopores, and finally micropores to simultaneously maximize surface area and accessibility. Micropore formation is optimized to maximize specific surface area while maintaining physical integrity of the fibers. Further, the combination of mesopores and micropores enables fast ion adsorption rates and capacity. Carbon fiber electrodes fabricated in this method achieve specific surface areas exceeding 1400 m 2 g -1 , with pore volumes exceeding 1.0cc g -1 . The pore size distributions are highly controlled, with 80% of total pore volume coming from pores <20nm in radius. In 500 ppm constant voltage CDI tests, these fiber electrodes obtain a salt adsorption capacity of over 14 mg g -1 at a salt adsorption rate of ~4mg g -1 min -1 , showcasing the high capacity matched with high rate of these easily fabricated, inexpensive materials.

36 MATERIALS SCIENCE↗

Gravity-driven controls on fluid and carbonate precipitation distributions in fractures

Abstract Many challenges related to carbon-dioxide ( $$\hbox {CO}_2$$ CO 2 ) sequestration in subsurface rock are linked to the injection of fluids through induced or existing fracture networks and how these fluids are altered through geochemical interactions. Here, we demonstrate that fluid mixing and carbonate mineral distributions in fractures are controlled by gravity-driven chemical dynamics. Using optical imaging and numerical simulations, we show that a density contrast between two miscible fluids causes the formation of a low-density fluid runlet that increases in areal extent as the fracture inclination decreases from 90 $$^\circ$$ ∘ (vertical fracture plane) to 30 $$^\circ$$ ∘ . The runlet is sustained over time and the stability of the runlet is controlled by the gravity-driven formation of 3D vortices that arise in a laminar flow regime. When homogeneous precipitation was induced, calcium carbonate covered the entire surface for horizontal fractures (0 $$^\circ$$ ∘ ). However, for fracture inclinations greater than 10 $$^\circ$$ ∘ , the runlet formation limited the areal extent of the precipitation to less than 15% of the fracture surface. These insights suggest that the ability to sequester $$\hbox {CO}_2$$ CO 2 through mineralization along fractures will depend on the fracture orientation relative to gravity, with horizontal fractures more likely to seal uniformly.

54 ENVIRONMENTAL SCIENCES↗

A Generalized Framework for Service Restoration in a Resilient Power Distribution System

An electric power grid is one of the complex infrastructures, and because of its complex nature, there is simply no way that outages can be completely avoided. Thus, a modern society that depends on reliable electric supply requires a resilient electric system that can recover from disruptions while integrating emerging smart grid technologies. Here, this article presents a novel approach for service restoration in a modern power distribution system with controllable switches and distributed generation (DG) resources for any kind of outage. The proposed framework supports both the traditional service restoration using feeder reconfiguration and the grid-forming DG-assisted intentional islands that are dynamically sized using algorithms based on the fault scenario, available resources, and priority of loads. The problem is formulated as a mixed-integer linear program that incorporates critical system connectivity and operating constraints. Simulations are performed to demonstrate the effectiveness of the proposed approach using a large-scale four-feeder 1069-bus three-phase unbalanced distribution test system. It is demonstrated that the framework is effective in utilizing all available resources in quickly restoring the power supply to improve resiliency during extreme events and is scalable for a large-scale unbalanced power distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Feedback control for unsteady flow and its application to the stochastic Burgers equation

The study applies mathematical methods of control theory to the problem of control of fluid flow with the long-range objective of developing effective methods for the control of turbulent flows. Model problems are employed through the formalism and language of control theory to present the procedure of how to cast the problem of controlling turbulence into a problem in optimal control theory. Methods of calculus of variations through the adjoint state and gradient algorithms are used to present a suboptimal control and feedback procedure for stationary and time-dependent problems. Two types of controls are investigated: distributed and boundary controls. Several cases of both controls are numerically simulated to investigate the performances of the control algorithm. Most cases considered show significant reductions of the costs to be minimized. The dependence of the control algorithm on the time-descretization method is discussed.

Choi, Haecheon↗

Flight Deck Design of a Hybrid Turbine/Electric Passenger Aircraft

NASA is exploring the development of a 180-passenger subsonic single engine aft turbine aircraft, The aft turbine provides electric power in a hybrid design to wing mounted electric engines, creating a highly efficient, high-bypass-ratio fan equivalent. The SUbsonic Single Aft eNgine (SUSAN) aircraft is being developed as a sustainable subsonic regional aircraft that seeks to reduce emission levels by 50% in the next few decades. Pilot-in-the-loop studies were conducted at the NASA Langley Research Center in Hampton, Virginia, to explore the flight deck design for the hybrid electric aircraft. Following modern trends in commercial aircraft flight decks with full time augmented controls and a quiet and dark philosophy, single throttle and simplified engine displays were developed for the SUSAN aircraft. The aircraft includes a single aft mounted turbine engine and 16 wing mounted electric fans. The final design was developed from feedback received during an earlier pilot-in-the-loop study where one, two, and three throttles were tested in standard airline operations, including various failures of the turbine and electric engines. Current flight deck designs normally provide control inceptors for each propulsion engine and an engine display for all primary aircraft engine parameters. With full time augmentation expected, a single throttle control with autothrottle always engaged, even during failures, is desired. Augmentation of flight controls using distributed thrust also requires full time control of the electric engines using automation. Additionally, electric engine thrust is augmented during climb based on battery state of charge. Thrust augmentation changes faster than human reaction time and therefore requires full-time automation. A pilot-in-the-loop study was conducted at the NASA Langley Research Center in Hampton, Virginia, to test the final design of the single throttle with simplified engine displays. Fourteen airline pilots evaluated the single throttle and engine display concept. Electric engine failures included one, four symmetric, and eight non-symmetric electric engine failures. The turbine engine was evaluated for complete and partial failure during critical phases of flight to include takeoff as well as enroute. Unexpected go-arounds increase workload and require significant throttle manipulation. Go-arounds were included to ensure the single throttle was usable for all phases of flight. Failures during takeoff required a return to the departure field and failures enroute required a diversion except for one and four electric engine failures as these failures did not affect aircraft flyability or range. There are currently no Part 25 aircraft certified with hybrid systems or electric engines with batteries as emergency propulsion. For turbine engine failures in the SUSAN aircraft design, range is limited to 30 minutes at full power. Battery state of charge and battery health displays were developed and tested for usability and to determine how well they supported pilot decisions for alternate airports during emergency diversions. Novel displays using shape and color were developed to provide immediate feedback when state of charge became critical. This paper details the pilot study including pilot feedback supporting the potential for increased automation and a single throttle control. Detailed recommendations are provided for a novel single throttle control and additional pilot controls to support selection of engines during start, shutdown, and engine troubleshooting procedures. This design deviates significantly from current practice of providing throttles for each propulsion engine. Engine display recommendations are provided based on pilot feedback during a guided post-evaluation interview. Battery state of charge and battery health display recommendations were collected from all airline crews. The simplified engine displays design was rated excellent as measured with a usability scale. Quantitative metrics include airspeed tracking, time to complete checklists, time to make diversion decisions and the quality of the diversion decision. Recommendations for future studies are documented with supporting research and current observations about upcoming flight deck certifications.

autothrottle↗

Flight Deck Design of a Hybrid Turbine/Electric Passenger Aircraft

NASA is exploring the development of a 180-passenger subsonic single engine aft turbine aircraft, The aft turbine provides electric power in a hybrid design to wing mounted electric engines, creating a highly efficient, high-bypass-ratio fan equivalent. The SUbsonic Single Aft eNgine (SUSAN) aircraft is being developed as a sustainable subsonic regional aircraft that seeks to reduce emission levels by 50% in the next few decades. Pilot-in-the-loop studies were conducted at the NASA Langley Research Center in Hampton, Virginia, to explore the flight deck design for the hybrid electric aircraft. Following modern trends in commercial aircraft flight decks with full time augmented controls and a quiet and dark philosophy, single throttle and simplified engine displays were developed for the SUSAN aircraft. The aircraft includes a single aft mounted turbine engine and 16 wing mounted electric fans. The final design was developed from feedback received during an earlier pilot-in-the-loop study where one, two, and three throttles were tested in standard airline operations, including various failures of the turbine and electric engines. Current flight deck designs normally provide control inceptors for each propulsion engine and an engine display for all primary aircraft engine parameters. With full time augmentation expected, a single throttle control with autothrottle always engaged, even during failures, is desired. Augmentation of flight controls using distributed thrust also requires full time control of the electric engines using automation. Additionally, electric engine thrust is augmented during climb based on battery state of charge. Thrust augmentation changes faster than human reaction time and therefore requires full-time automation. A pilot-in-the-loop study was conducted at the NASA Langley Research Center in Hampton, Virginia, to test the final design of the single throttle with simplified engine displays. Fourteen airline pilots evaluated the single throttle and engine display concept. Electric engine failures included one, four symmetric, and eight non-symmetric electric engine failures. The turbine engine was evaluated for complete and partial failure during critical phases of flight to include takeoff as well as enroute. Unexpected go-arounds increase workload and require significant throttle manipulation. Go-arounds were included to ensure the single throttle was usable for all phases of flight. Failures during takeoff required a return to the departure field and failures enroute required a diversion except for one and four electric engine failures as these failures did not affect aircraft flyability or range. There are currently no Part 25 aircraft certified with hybrid systems or electric engines with batteries as emergency propulsion. For turbine engine failures in the SUSAN aircraft design, range is limited to 30 minutes at full power. Battery state of charge and battery health displays were developed and tested for usability and to determine how well they supported pilot decisions for alternate airports during emergency diversions. Novel displays using shape and color were developed to provide immediate feedback when state of charge became critical. This paper details the pilot study including pilot feedback supporting the potential for increased automation and a single throttle control. Detailed recommendations are provided for a novel single throttle control and additional pilot controls to support selection of engines during start, shutdown, and engine troubleshooting procedures. This design deviates significantly from current practice of providing throttles for each propulsion engine. Engine display recommendations are provided based on pilot feedback during a guided post-evaluation interview. Battery state of charge and battery health display recommendations were collected from all airline crews. The simplified engine displays design was rated excellent as measured with a usability scale. Quantitative metrics include airspeed tracking, time to complete checklists, time to make diversion decisions and the quality of the diversion decision. Recommendations for future studies are documented with supporting research and current observations about upcoming flight deck certifications.

autothrottle↗

The impact of circulation control on rotary aircraft controls systems

Application of circulation to rotary wing systems is a new development. Efforts to determine the near and far field flow patterns and to analytically predict those flow patterns have been underway for some years. Rotary wing applications present a new set of challenges in circulation control technology. Rotary wing sections must accommodate substantial Mach number, free stream dynamic pressure and section angle of attack variation at each flight condition within the design envelope. They must also be capable of short term circulation blowing modulation to produce control moments and vibration alleviation in addition to a lift augmentation function. Control system design must provide this primary control moment, vibration alleviation and lift augmentation function. To accomplish this, one must simultaneously control the compressed air source and its distribution. The control law algorithm must therefore address the compressor as the air source, the plenum as the air pressure storage and the pneumatic flow gates or valves that distribute and meter the stored pressure to the rotating blades. Also, mechanical collective blade pitch, rotor shaft angle of attack and engine power control must be maintained.

Kingloff, R. F.↗

Direct control of the grid point distribution in meshes generated by elliptic equations

The generation of computational grids suitable for obtaining accurate numerical solutions to the three-dimensional Navier-Stokes equations is the subject of intensive research. For a wide class of nozzle configurations, a three-dimensional grid can be constructed by a sequence of two-dimensional grids in successive cross-sectional planes. The present paper is concerned with numerical generation of two-dimensional grids. An effective method of interior grid control is presented based on a modified elliptic system containing free parameters. For a simply connected region, the free parameters are computed from the Dirichlet boundary values. The resulting interior grid point distribution is controlled entirely by a priori selection of the grid point distribution along the boundaries of the section.

Middlecoff, J. F.↗

Performance Evaluation of Distributed Energy Resource Management Algorithm in Large Distribution Networks

This paper presents performance evaluation of hierarchical optimization and control for distributed energy resource management system (DERMS) in large distribution networks via an advanced hardware-in-the-loop (HIL) platform. The HIL platform provides realistic testing in a laboratory environment, including the accurate modeling of a full-scale distribution system of 11,000 nodes, the DERMS software controller, and 90 power hardware photovoltaics (PVs) and battery inverters. The applied DERMS algorithm is designed based on a realtime optimal power flow algorithm and implemented with acceleration design that performs fast dispatch of simulated PVs and real physical hardware DER devices every 4 seconds.

DERMS↗