Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

System and Methods for Deploying Payloads

Embodiments of the present invention include systems for launching primary or secondary payloads or actuating other launch vehicle or payload or instrumentation devices. The system includes an adapter assembly and at least one sequencer mounted to the adapter assembly. The sequencer includes: controller boards, each of the controller boards having a controller for controlling deployment of the payloads and data files; output ports coupled to the controller boards and configured to transmit signals from the controller boards to dispensers therethrough, deployment mechanisms containing the payloads, the adapter assembly having channels for accommodating the dispensers; and a detector coupled to the controller boards and adapted to detect an external signal and, in response to the external signal, to send an initiation signal to the controller boards. The system also includes at least one power supply coupled to the sequencer and adapted to provide an electrical power to the sequencer.

Ghassemieh, Shakib M.↗

Time Resolved Irradiance of an Integrating Sphere Illuminated by a Mode-Locked Optical Parametric Oscillator

Tunable laser based illumination sources have been adopted by a number of recent hyperspectral instruments for pre-launch spectral radiometric calibration. Some of these sources use mode-locked cavity configurations, which produce a pulse train and create an undesirable fluctuation in the radiometric source at the mode locking frequency. Although typically this frequency is several orders of magnitude higher than the instrument response, care must be taken to ensure the resultant calibration is not biased due to detector or electronic saturation effects. The temporal averaging properties of an integrating sphere can be used to reduce high frequency fluctuations to an acceptable level. In this work, the time resolved output of an integrating sphere coupled with a mode-locked source was measured. A 76 cm diameter sphere with 30 cm output aperture was illuminated using a mode-locked pulse train at 76 MHz, with single pulse durations of 12 ps. The time constant of the sphere was found to be 36 ns, and the resultant temporal averaging of pulses produced a maximum time varying irradiance at the output of 20% of the mean. The form of this time variance is a sawtooth pattern, with a sharp rise during the introduction of each pulse into the sphere followed by a slower decay between pulses. A comparison of instrument calibration data generated with this integrating sphere using both a mode locked source and a continuous wave source is also given. .

McAndrew, Brendan↗

MISR Level 1B1 Radiance Data (MI1B1_V1)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=275 m for red band only; Longitude_Resolution=275 m for red band only; Horizontal_Resolution_Range=250 meters - < 500 meters; Temporal_Resolution=about 15 orbits/day; Temporal_Resolution_Range=Daily - < Weekly, about 15 orbits/day, Daily - < Weekly].

EOSDIS↗

MISR Level 1B1 Radiance Data (MI1B1_V2)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=1.1 km; Longitude_Resolution=1.1 km; Temporal_Resolution=about 15 orbits/day; Temporal_Resolution_Range=about 15 orbits/day].

AM-1↗

Possibilities for LWIR detectors using MBE-grown Si(/Si(1-x)Ge(x) structures

Traditionally, long wavelength infrared (LWIR) detection in Si-based structures has involved either extrinsic Si or Si/metal Schottky barrier devices. Molecular beam epitaxially (MBE) grown Si and Si/Si(1-x)Ge(x) heterostructures offer new possibilities for LWIR detection, including sensors based on intersubband transitions as well as improved conventional devices. The improvement in doping profile control of MBE in comparison with conventional chemical vapor deposited (CVD) Si films has resulted in the successful growth of extrinsic Si:Ga, blocked impurity-band conduction detectors. These structures exhibit a highly abrupt step change in dopant profile between detecting and blocking layers which is extremely difficult or impossible to achieve through conventional epitaxial growth techniques. Through alloying Si with Ge, Schottky barrier infrared detectors are possible, with barrier height values between those involving pure Si or Ge semiconducting materials alone. For both n-type and p-type structures, strain effects can split the band edges, thereby splitting the Schottky threshold and altering the spectral response. Measurements of photoresponse of n-type Au/Si(1-x)Ge(x) Schottky barriers demonstrate this effect. For intersubband multiquntum well (MQW) LWIR detection, Si(1-x)Ge(x)/Si detectors grown on Si substrates promise comparable absorption coefficients to that of the Ga(Al)As system while in addition offering the fundamental advantage of response to normally incident light as well as the practical advantage of Si-compatibility. Researchers grew Si(1-x)Ge(x)/Si MQW structures aimed at sensitivity to IR in the 8 to 12 micron region and longer, guided by recent theoretical work. Preliminary measurements of n- and p-type Si(1-x)Ge(x)/Si MQW structures are given.

Hauenstein, Robert J.↗

A directional gamma-ray telescope using coded aperture techniques

A directional detector for gamma-ray astronomy has been developed to image sources in the energy range 0.1 to 5 MeV. An array of 35 gain stabilized bismuth germanate detectors, together with a coded aperture mask based on a uniformly redundant array allows imaging in 4 deg square sky bins over a 16 x 24 deg field-of-view. The position of a strong point source, such as the Crab Nebula, can be determined to within not more than about 1 deg. A complementary 'anti-mask' greatly reduces systematic effects arising from nonuniform background rates amongst the detectors. The telescope has an effective area of 190 sq cm and an energy resolution of 19.5 percent FWHM at 662 keV. Results of laboratory tests of the imaging system, including the ability to image multiple sources, uniformity of response over the field-of-view, and the effect of the 'anti-mask', are in good agreement with computer simulations. Features of the flight detector system are described and results of laboratory tests and computer simulations are reviewed. A balloon flight of the telescope is planned for the fall of 1982.

Mcconnell, M. L.↗

Carbon Dioxide Dispersion in the Combustion Integrated Rack Simulated Numerically

When discharged into an International Space Station (ISS) payload rack, a carbon dioxide (CO2) portable fire extinguisher (PFE) must extinguish a fire by decreasing the oxygen in the rack by 50 percent within 60 sec. The length of time needed for this oxygen reduction throughout the rack and the length of time that the CO2 concentration remains high enough to prevent the fire from reigniting is important when determining the effectiveness of the response and postfire procedures. Furthermore, in the absence of gravity, the local flow velocity can make the difference between a fire that spreads rapidly and one that self-extinguishes after ignition. A numerical simulation of the discharge of CO2 from PFE into the Combustion Integrated Rack (CIR) in microgravity was performed to obtain the local velocity and CO2 concentration. The complicated flow field around the PFE nozzle exits was modeled by sources of equivalent mass and momentum flux at a location downstream of the nozzle. The time for the concentration of CO2 to reach a level that would extinguish a fire anywhere in the rack was determined using the Fire Dynamics Simulator (FDS), a computational fluid dynamics code developed by the National Institute of Standards and Technology specifically to evaluate the development of a fire and smoke transport. The simulation shows that CO2, as well as any smoke and combustion gases produced by a fire, would be discharged into the ISS cabin through the resource utility panel at the bottom of the rack. These simulations will be validated by comparing the results with velocity and CO2 concentration measurements obtained during the fire suppression system verification tests conducted on the CIR in March 2003. Once these numerical simulations are validated, portions of the ISS labs and living areas will be modeled to determine the local flow conditions before, during, and after a fire event. These simulations can yield specific information about how long it takes for smoke and combustion gases produced by a fire to reach a detector location, how large the fire would be when the detector alarms, and the behavior of the fire until it has been extinguished. This new capability could then be used to optimize the location of fire detectors and fire-suppression ports as well as to evaluate the effectiveness of fire suppressants and response strategies. Numerical data collected from these simulations could also be used to develop a virtual reality fire event for crew training and fire safety awareness. This work is funded by NASA's Bioastronautics Initiative, which has the objective of ensuring and enhancing the health, safety, and performance of humans in space. As part of this initiative, the Microgravity Combustion Science Branch at the NASA Glenn Research Center is conducting spacecraft fire safety research to significantly improve fire safety on inhabited spacecraft.

Wu, Ming-Shin↗

Photocell shadowing technique improves light source detector

Lightweight, compact modular system that includes an acquisition photocell is used as a light source tracking detector that exhibits minimum scale factor change with increased light source angle. Photocells of various types, responsive to other portions of the spectrum, could be used to acquire and track infrared, ultraviolet, and other source fluxes.

Carpenter, D. G.↗

The growth of deactivated layers on CsI(Na) scintillating crystals

An effective and sensitive measurement of the depth of a deactivated or dead layer can be obtained from the relative attenuation of the 22.162 KeV and 87.9 KeV X-rays emitted by Cd 109. The alpha-particles emitted by Am 241 are also useful in measuring dead layers less than 25 microns. The properties and temporal development of dead layers are discussed in detail. The rate of growth of a deal layer is closely related to the ambient humidity, and the damage to the crystal is irreversible by any known process. The dead layer can be minimized by polishing all crystal surfaces and by keeping the crystal in a vacuum or a dry atmosphere. Since a dead layer seriously inhibits the response of a crystal to X-rays of energies below approximately 20 keV, CsI(Na) detectors should not be used at these energies unless precautions are taken to ensure that no dead layer forms.

Goodman, N. B.↗

Image dissector camera system study

Various aspects of a rendezvous and docking system using an image dissector detector as compared to a GaAs detector were discussed. Investigation into a gimbled scanning system is also covered and the measured video response curves from the image dissector camera are presented. Rendezvous will occur at ranges greater than 100 meters. The maximum range considered was 1000 meters. During docking, the range, range-rate, angle, and angle-rate to each reflector on the satellite must be measured. Docking range will be from 3 to 100 meters. The system consists of a CW laser diode transmitter and an image dissector receiver. The transmitter beam is amplitude modulated with three sine wave tones for ranging. The beam is coaxially combined with the receiver beam. Mechanical deflection of the transmitter beam, + or - 10 degrees in both X and Y, can be accomplished before or after it is combined with the receiver beam. The receiver will have a field-of-view (FOV) of 20 degrees and an instantaneous field-of-view (IFOV) of two milliradians (mrad) and will be electronically scanned in the image dissector. The increase in performance obtained from the GaAs photocathode is not needed to meet the present performance requirements.

Howell, L.↗

Theoretical and experimental studies of error in square-law detector circuits

Square law detector circuits to determine errors from the ideal input/output characteristic function were investigated. The nonlinear circuit response is analyzed by a power series expansion containing terms through the fourth degree, from which the significant deviation from square law can be predicted. Both fixed bias current and flexible bias current configurations are considered. The latter case corresponds with the situation where the mean current can change with the application of a signal. Experimental investigations of the circuit arrangements are described. Agreement between the analytical models and the experimental results are established. Factors which contribute to differences under certain conditions are outlined.

Stanley, W. D.↗

CLAES focal plane array

The Cryogenic Limb Array Etalon Spectrometer for the NASA Upper Atmospheric Research Satellite uses solid-state focal plane arrays to detect emission from the earth's atmosphere over the IR wavelength range 3.5 to 13 microns. This paper discusses the design of the focal plane detector assembly and compares calculated performance with measurements. Measurements were made of focal plane noise and responsivity as functions of frequency (2 to 500 Hz) and temperature (12 to 19 K), pixel-to-pixel and across-array crosstalk, and linearity over a dynamic range of 100,000. The measurements demonstrate that the arrays satisfy the science requirements, and that, in general, there is reasonable agreement between the measurements and the analytical model.

Roche, A. E.↗

IMS software developments for the detection of chemical warfare agent

Interference compounds like gasoline, diesel, burning wood or fuel, etc. are presented in common battlefield situations. These compounds can cause detectors to respond as a false positive or interfere with the detector's ability to respond to target compounds such as chemical warfare agents. To ensure proper response of the ion mobility spectrometer to chemical warfare agents, two special software packages were developed and incorporated into the Bruker RAID-1. The programs suppress interferring signals caused by car exhaust or smoke gases resulting from burning materials and correct the influence of variable sample gas humidity which is important for detection and quantification of blister agents like mustard gas or lewisite.

Klepel, ST.↗

Testing of 100 mK bolometers for space applications

Electrical and optical performance data are presented for a prototype 100 mK spider-web bolometer operating under very low photon backgrounds. These data are compared with the bolometer theory and are used to estimate the expected sensitivity of such a detector used for low background space astronomy. The results demonstrate that the sensitivity and speed of response requirements of the bolometer instruments proposed for these missions can be met by 100 mK spider-web bolometers using neutron transmutation doped germanium as the temperature sensitive element.

Murray, A. G.↗

Global Lightning Variations Caused by Changes in Thunderstorm Flash Rate and by Changes in Number of Thunderstorms

Global lightning activity is highly variable on many time scales. This variability is attributable to changes in the flash rate per thunderstorm, the number of thunderstorms, or a combination. The TRMM Mission offers lightning observations from the Optical Transient Detector (OTD) and the Lightning Imaging Sensor (LIS) in space. Both are used to examine the response of these parameters to thermodynamic forcing of deep convection on the diurnal and annual time scales. On both time scales, the changes in the number of storms dominate the variations in total lightning activity. On the diurnal time scale, the mean flash rate appears to vary with cloud buoyancy, peaking in early afternoon and declining in late afternoon, but the contribution of number of thunderstorms is 2-3 times greater that the mean storm flash rate. On the annual time scale, almost all of the total lightning response is due to changes in the number of storms, with a negligible contribution from flash rate. Evidence is presented that the LIS/OTD 'area' is a meaningful objective identifier for a thunderstorm.

Williams, E. K.↗

Commodity-Free Calibration

Commodity-free calibration is a reaction rate calibration technique that does not require the addition of any commodities. This technique is a specific form of the reaction rate technique, where all of the necessary reactants, other than the sample being analyzed, are either inherent in the analyzing system or specifically added or provided to the system for a reason other than calibration. After introduction, the component of interest is exposed to other reactants or flow paths already present in the system. The instrument detector records one of the following to determine the rate of reaction: the increase in the response of the reaction product, a decrease in the signal of the analyte response, or a decrease in the signal from the inherent reactant. With this data, the initial concentration of the analyte is calculated. This type of system can analyze and calibrate simultaneously, reduce the risk of false positives and exposure to toxic vapors, and improve accuracy. Moreover, having an excess of the reactant already present in the system eliminates the need to add commodities, which further reduces cost, logistic problems, and potential contamination. Also, the calculations involved can be simplified by comparison to those of the reaction rate technique. We conducted tests with hypergols as an initial investigation into the feasiblility of the technique.

Source record↗

A Fiber-Optic Aircraft Lightning Current Measurement Sensor

A fiber-optic current sensor based on the Faraday Effect is developed for aircraft installations. It can measure total lightning current amplitudes and waveforms, including continuing current. Additional benefits include being small, lightweight, non-conducting, safe from electromagnetic interference, and free of hysteresis and saturation. The Faraday Effect causes light polarization to rotate in presence of magnetic field in the direction of light propagation. Measuring the total induced light polarization change yields the total current enclosed. The system operates at 1310nm laser wavelength and can measure approximately 300 A - 300 kA, a 60 dB range. A reflective polarimetric scheme is used, where the light polarization change is measured after a round-trip propagation through the fiber. A two-detector setup measures the two orthogonal polarizations for noise subtraction and improved dynamic range. The current response curve is non-linear and requires a simple spline-fit correction. Effects of high current were achieved in laboratory using combinations of multiple fiber and wire loops. Good result comparisons against reference sensors were achieved up to 300 kA. Accurate measurements on a simulated aircraft fuselage and an internal structure illustrate capabilities that maybe difficult with traditional sensors. Also tested at a commercial lightning test facility from 20 kA to 200 kA, accuracy within 3-10% was achieved even with non-optimum setups.

Nguyen, Truong X.↗

Principal Components Analysis of a JWST NIRSpec Detector Subsystem

We present principal component analysis (PCA) of a flight-representative James Webb Space Telescope NearInfrared Spectrograph (NIRSpec) Detector Subsystem. Although our results are specific to NIRSpec and its T - 40 K SIDECAR ASICs and 5 m cutoff H2RG detector arrays, the underlying technical approach is more general. We describe how we measured the systems response to small environmental perturbations by modulating a set of bias voltages and temperature. We used this information to compute the systems principal noise components. Together with information from the astronomical scene, we show how the zeroth principal component can be used to calibrate out the effects of small thermal and electrical instabilities to produce cosmetically cleaner images with significantly less correlated noise. Alternatively, if one were designing a new instrument, one could use a similar PCA approach to inform a set of environmental requirements (temperature stability, electrical stability, etc.) that enabled the planned instrument to meet performance requirements

Analysis↗