Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

The Future of Single- to Multi-band Detector Technologies: Review

Using classical optical components such as filters, prisms and gratings to separate the desired wavelengths before they reach the detectors results in complex optical systems composed of heavy components. A simpler system will result by utilizing a single optical system and a detector that responds separately to each wavelength band. Therefore, a continuous endeavors to develop the capability to reliably fabricate detector arrays that respond to multiple wavelength regions. In this article, we will review the state-of-the-art single and multicolor detector technologies over a wide spectral-range, for use in space-based and airborne remote sensing applications. Discussions will be focused on current and the most recently developed focal plane arrays (FPA) in addition to emphasizing future development in UV-to-Far infrared multicolor FPA detectors for next generation space-based instruments to measure water vapor and greenhouse gases. This novel detector component will make instruments designed for these critical measurements more efficient while reducing complexity and associated electronics and weight. Finally, we will discuss the ongoing multicolor detector technology efforts at NASA Langley Research Center, Jet Propulsion Laboratory, Rensselaer Polytechnic Institute, and others.

Abedin, M. Nurul↗

New techniques for the detection and capture of micrometeoroids

In order to understand the origin and distribution of the biogenic elements and their compounds in the solar system, it will be necessary to study material from many classes of objects. Chemical, elemental, and isotopic measurements of returned samples of comets, asteroids, and possibly extrasolar system dust clouds would provide information on a particularly important class: the primitive objects. Extraterrestrial micron-sized particles in the vicinity of Earth are one source of such materials that might otherwise be inaccessible. The Space Station appears to be an eminently suitable platform from which to collect and detect these various particles. The primary challenge, however, is to collect intact, uncontaminated particles which will be encountered at tens of kilometers per seconds. A concept for a micrometeoroid detector that could be deployed from the Space Station was developed which uses a large area detector plate implanted with acoustic transducers. A concept of a nondestructive micrometeoroid collector for the Space Station was also developed. Particles collected would then be returned to Earth for subsequent analysis.

Wolfe, J. H.↗

The Identification of Scientific Programs to Utilize the Space Environment

A program to identify and develop ideas for scientific experimentation on the long duration exposure facility (LDEF) was completed. Four research proposals were developed: (1) Ultra pure germanium gamma ray radiation detectors in the space environment, intended to develop and demonstrate an X-ray and gamma-ray spectroscopy system incorporating a temperature cyclable high-purity germanium detector and diode heat pipe cryogenic system for cooling, (2) growth, morphogenesis and metabolism of plant embryos in the zero-gravity environment, to investigate if the space environment induces mutations in the embryogenic cells so that mutants of commercial significance with desirable attributes may be obtained, (3) effect of zero gravity on the growth and pathogenicity of selected zoopathic fungi. It is possible that new kinds of treatment for candidiasis, and tichophytosis could eventuate from the results of the proposed studies, and (4) importance of gravity to survival strategies of small animals. Gravitational effects may be direct or mediate the selection of genetic variants that are preadapted to weightlessness.

Kulacki, F. A.↗

Flame Detector

Scientific Instruments, Inc. has now developed a second generation, commercially available instrument to detect flames in hazardous environments, typically refineries, chemical plants and offshore drilling platforms. The Model 74000 detector incorporates a sensing circuit that detects UV radiation in a 100 degree conical field of view extending as far as 250 feet from the instrument. It operates in a bandwidth that makes it virtually 'blind' to solar radiation while affording extremely high sensitivity to ultraviolet flame detection. A 'windowing' technique accurately discriminates between background UV radiation and ultraviolet emitted from an actual flame, hence the user is assured of no false alarms. Model 7410CP is a combination controller and annunciator panel designed to monitor and control as many as 24 flame detectors. *Model 74000 is no longer being manufactured.

Source record↗

Fabrication of an Absorber-Coupled MKID Detector

Absorber-coupled microwave kinetic inductance detector (MKID) arrays were developed for submillimeter and far-infrared astronomy. These sensors comprise arrays of lambda/2 stepped microwave impedance resonators patterned on a 1.5-mm-thick silicon membrane, which is optimized for optical coupling. The detector elements are supported on a 380-mm-thick micro-machined silicon wafer. The resonators consist of parallel plate aluminum transmission lines coupled to low-impedance Nb microstrip traces of variable length, which set the resonant frequency of each resonator. This allows for multiplexed microwave readout and, consequently, good spatial discrimination between pixels in the array. The transmission lines simultaneously act to absorb optical power and employ an appropriate surface impedance and effective filling fraction. The fabrication techniques demonstrate high-fabrication yield of MKID arrays on large, single-crystal membranes and sub-micron front-to-back alignment of the micro strip circuit. An MKID is a detector that operates upon the principle that a superconducting material s kinetic inductance and surface resistance will change in response to being exposed to radiation with a power density sufficient to break its Cooper pairs. When integrated as part of a resonant circuit, the change in surface impedance will result in a shift in its resonance frequency and a decrease of its quality factor. In this approach, incident power creates quasiparticles inside a superconducting resonator, which is configured to match the impedance of free space in order to absorb the radiation being detected. For this reason MKIDs are attractive for use in large-format focal plane arrays, because they are easily multiplexed in the frequency domain and their fabrication is straightforward. The fabrication process can be summarized in seven steps: (1) Alignment marks are lithographically patterned and etched all the way through a silicon on insulator (SOI) wafer, which consists of a thin silicon membrane bonded to a thick silicon handle wafer. (2) The metal microwave circuitry on the front of the membrane is patterned and etched. (3) The wafer is then temporarily bonded with wafer wax to a Pyrex wafer, with the SOI side abutting the Pyrex. (4) The silicon handle component of the SOI wafer is subsequently etched away so as to expose the membrane backside. (5) The wafer is flipped over, and metal microwave circuitry is patterned and etched on the membrane backside. Furthermore, cuts in the membrane are made so as to define the individual detector array chips. (6) Silicon frames are micromachined and glued to the silicon membrane. (7) The membranes, which are now attached to the frames, are released from the Pyrex wafer via dissolution of the wafer wax in acetone.

Brown, Ari↗

A comparison of the neutron detection efficiency and response characteristics of two pixelated PSD-capable organic scintillator detectors with different photo-detection readout methods

Here, we characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved performance over the previously developed PMT-based detector both in terms of uniformity and neutron detection efficiency. Each detector array uses PSD-capable plastic scintillator as a detection medium. We describe the calibration and neutron efficiency measurement of both detectors using a 137 Cs source for energy calibration and a 252 Cf source for calibration of the neutron response. We find that the intrinsic neutron detection efficiency of the SiPM-based array is (30.2 ± 0.9)%, which is almost twice that of the PMT-based array, which we measure to be (16.9 ± 0.1)%.

47 OTHER INSTRUMENTATION↗

Cloud Top Scanning radiometer (CTS)

A scanning radiometer to be used for measuring cloud radiances in each of three spectral regions is described. Significant features incorporated in the Cloud Top Scanner design are: (1) flexibility and growth potential through use of easily replaceable modular detectors and filters; (2) full aperture, multilevel inflight calibration; (3) inherent channel registration through employment of a single shared field stop; and (4) radiometric sensitivity margin in a compact optical design through use of Honeywell developed (Hg,Cd)Te detectors and preamplifiers.

Source record↗

Atmospheric Trace Gas Abundances and Stable Isotope Ratios via IR-LIF

We propose to develop new technologies with support provided by PIDDP that will enable the in situ measurements of abundances and stable isotope ratios in important radiatively and biogenically active gases such as carbon dioxide, carbon monoxide, water, methane, nitrous oxide, and hydrogen sulfide to very high precision (0.1 per mil or better for the isotopic ratios, for example). Such measurements, impossible at present, could provide pivotal new constraints on the global (bio)geochemical budgets of these critical species, and could also be used to examine the dynamics of atmospheric transport on Mars, Titan, and other solar system bodies. We believe the combination of solid state light sources with imaging of the IR laser induced fluorescence (IR-LIF) via newly available detector arrays will make such in situ measurements possible for the first time. Even under ambient terrestrial conditions, the LIF yield from vibrational excitation of species such as water and carbon dioxide should produce emission measures well in excess of ten billion photons/sec from samples volumes of order 1 c.c. These count rates can, in principle, yield detection limits into the sub-ppt range that are required for the in situ isotopic study of atmospheric trace gases. While promising, such technologies are relatively immature, but developing rapidly, and there are a great many uncertainties regarding their applicability to in situ IR-LIF planetary studies. We therefore feel PIDDP support will be critical to developing these new tools, and propose a three-year program to combine microchip near-IR lasers with low background detection axes and state-of-the-art HgCdTe detectors developed for astronomical spectroscopy to investigate the sensitivity of IR-LIF under realistic planetary conditions, to optimize the optical pumping and filtering schemes for important species, and to apply the spectrometer to the non-destructive measurement of stable isotopes in a variety of test samples. These studies form the necessary precursors to the development of compact, lightweight stable isotope/trace gas sensors for future planetary missions.

Blake, Geoffrey A.↗

Development of a scintillator based fast-ion loss detector for the Wendelstein 7-X stellarator

A new scintillator based fast-ion loss detector (FILD) system has been designed for the Wendelstein 7-X (W7-X) stellarator. The mechanical design of the system is presented here along with engineering analyses of the system. This includes an assessment of the structural loads which also considers electromagnetic forces calculated for possible disruption scenarios as well as a mode frequency analysis of the system. Furthermore, an analysis of the thermal characteristics of the actively cooled probe head under prescribed steady state and transient heat loads is presented. Finally, the optical relay system is described and its properties used to forward model synthetic camera signals using the FILDSIM code and based on theoretical fast-ion losses incident on the probe head calculated using the ASCOT5 code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and test of photon-counting microchannel plate detector arrays for use on space telescopes

The full sensitivity, dynamic range, and photometric stability of microchannel array plates(MCP) are incorporated into a photon-counting detection system for space operations. Components of the system include feedback-free MCP's for high gain and saturated output pulse-height distribution with a stable response; multi-anode readout arrays mounted in proximity focus with the output face of the MCP; and multi-layer ceramic headers to provide electrical interface between the anode array in a sealed detector tube and the associated electronics.

Timothy, J. G.↗

The development and test of multi-anode microchannel array detector systems. 2: Soft X-ray detectors

The techniques and procedures for producing very-large-format pulse-counting array detector systems for use in forthcoming high-energy astrophysics facilities were defined, and the structures and performance characteristics of high-sensitivity photocathodes for use at soft X-ray wavelengths between 100 and 1 A were determined. The progress made to date in each of these areas are described and the tasks that will be undertaken when the program is continued are summarized.

Timothy, J. G.↗

Development of a unique laboratory standard: Indium gallium arsenide detector for the 500-1700 nm spectral region

A planar (5 mm diameter) indium gallium arsenide detector having a high (greater than 50 pct) quantum efficiency from the visible into the infrared spectrum (500 to 1700 nm) was fabricated. Quantum efficiencies as high as 37 pct at 510 nm, 58 pct at 820 nm and 62 pct at 1300 nm and 1550 nm were measured. A planar InP/InGaAs detector structure was also fabricated using vapor phase epitaxy to grow device structures with 0, 0.2, 0.4 and 0.6 micrometer thick InP caps. Quantum efficiency was studied as a function of cap thickness. Conventional detector structures were also used by completely etching off the InP cap after zinc diffusion. Calibrated quantum efficiencies were measured. Best results were obtained with devices whose caps were completely removed by etching. Certain problems still remain with these detectors including non-uniform shunt resistance, reproducibility, contact resistance and narrow band anti-reflection coatings.

Source record↗

Development of the RAIDS extreme ultraviolet wedge and strip detector

In the next few years the Remote Atmospheric and Ionospheric Detector System (RAIDS) package will be flown on a Tiros spacecraft. The EUV spectrometer experiment contains a position-sensitive detector based on wedge and strip anode technology. A detector design has been implemented in brazed alumina and kovar to provide a rugged bakeable housing and anode. A stack of three 80:1 microchannel plates is operated at 3500-4100 V. to achieve a gain of about 10 to the 7th. The top MCP is to be coated with MgF for increased quantum efficiency in the range of 50-115 nm. A summary of fabrication techniques and detector performance characteristics is presented.

Kayser, D. C.↗

Performance characteristics of the imaging MAMA detector systems for SOHO, STIS, and FUSE/Lyman

Imaging Extreme Ultraviolet (EUV) Multi-Anode Microchannel Array (MAMA) detector systems with formats of 360 x 1024 pixels and pixel dimensions of 25 x 25 sq microns are being fabricated and tested for flight in two instruments on the ESA/NASA Solar and Heliospheric Observatory (SOHO). In addition, very-large-format (1024 x 1024)- and (2048 x 2048)-pixel Far Ultraviolet (FUV) and EUV MAMA detectors with pixel dimensions of 25 x 25 sq microns are being fabricated and tested for use in the NASA Goddard Space Flight Center's Hubble Space Telescope Imaging Spectrograph (STIS), a second-generation instrument scheduled for in-orbit installation in 1997. Finally, FUV MAMA detectors with formats of 224 x 960 pixels and pixel dimensions of 14 x 14 sq microns are being evaluated as prototypes of the detector for the prime FUV spectrograph of the Far Ultraviolet Spectroscopic Explorer (FUSE/Lyman) mission. The configurations and performance characteristics of the different detector systems are described, and the plans for further development of the Advanced Technology MAMA detector system discussed.

Timothy, J. G.↗

SCGSR Final Report

Dual phase noble liquid time projection chambers (TPCs) have an unprecedented sensitivity towards dark matter searches and neutrinos, owing to their ability to detect single electrons. When a particle deposits energy into one of these detectors, electrons are released and drifted into a gaseous region of high electric field. In the gas, the electrons are accelerated to produce extra light into what is called an S2 pulse. This light is far easier to detect than the current induced from a single electron. The two widely used elements for noble liquid detectors are Xe and Ar. Xe has a larger chance of being hit by neutrinos or dark matter, but ends with a lower (i.e. harder to detect) energy when struck. However, Ar light is hard to reflect and detect due to its short wavelength which is absorbed by most materials. While one may use TPB to re-emit this light at a longer wavelength, spatial variations of TPB thickness can smear the amount of re-emitted light, and thus cause a poor S2 energy resolution and spatial resolution. Furthermore, a single electron pulse in Ar is spread over a much longer time than one in Xe, which makes it harder to identify single electrons in Ar. The goal of Xe doping is to combine the best aspects of Ar with the best aspects of Xe. More specifically, this means a detector with a larger yield of photons and electrons produced per energy deposition, an ability to collect more of the light given by those signals, and a narrower pulse from the electron signal. During this project, we developed and operated a detector that can overcome the thermodynamic challenges of Xe doping – namely, preventing Xe from freezing. In the first experimental run during this award period, we found that we can achieve at least 5% of Xe in LAr, and measure the Xe concentration in the gas. In the second run, we installed our detector and saw the first S2 pulses in a dual phase Xe doped LAr TPC. With the data we took, we quantified the effect of Xe doping on the detectability of wavelength-shifted light produced in a Xe doped Ar mixture, as well as the single electron pulse shape. While the Ar light has successfully been wavelength shifted, we learned that much to our surprise, Xe doping actually makes the S2 pulse wider before it makes it narrower.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗