On the Use of a Large Database of Simulated Wind Turbine Loads to Aid in Assessing Design Standard Provisions.
Abstract Not Provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract Not Provided
Abstract Not Provided
Abstract Not Provided
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Dynamic pricing electricity tariffs, now the default for large customers in California (peak demand of 200 kW and higher for PG&E and SCE, and 20 kW and higher for SDG&E), are providing Federal facilities new opportunities to cut their electricity bills and help them meet their energy savings mandates. The U.S. Department of Energy’s (DOE) Federal Energy Management Program (FEMP) has created this fact sheet to help California federal facilities take advantage of these opportunities through “rate-responsive building operation.” Rate-responsive building operation involves designing your load management strategies around your facility’s variable electric rate, using measures that require little or no financial investment.
Explore the source record for details and available documents.
In the U.S., there are approximately 2.6 million dwellings that use electricity for heating in cold and very cold regions with an annual energy consumption of 0.16 quads (0.17 EJ). A high performance cold climate heat pump (CCHP) would result in significant savings over current technologies (greater than 60% compared to electric resistance heating). We developed an air-source cold climate heat pump, which uses tandem compressors, with a single compressor rated for the building design cooling load, and running two compressors to provide, at -13 F (-25 C), 75% of rated heating capacity. The tandem compressors were optimized for heating operation and are able to tolerate discharge temperatures up to 280 F (138 C). A field investigation was conducted in the winter of 2015, in an occupied home in Ohio, USA. During the heating season, the seasonal COP was measured at 3.16, and the heat pump was able to operate down to -13 F (-25 C) and eliminate resistance heat use. The heat pump maintained an acceptable comfort level throughout the heating season. In comparison to a previous single-speed heat pump in the home, the CCHP demonstrated more than 40% energy savings in the peak heating load month. This paper illustrates the measured field performance, including compressor run time, frost/defrosting operations, distributions of building heating load and capacity delivery, comfort level, field measured COPs, etc.
This paper considers distribution networks with distributed energy resources and discrete-rate loads, and designs an incentive-based algorithm that allows the network operator and the customers to pursue given operational and economic objectives, while concurrently ensuring that voltages are within prescribed limits. Four major challenges include: (1) the non-convexity from discrete decision variables, (2) the non-convexity due to a Stackelberg game structure, (3) unavailable private information from customers, and (4) different update frequency from two types of devices. In this paper, we first make convex relaxation for discrete variables, then reformulate the non-convex structure into a convex optimization problem together with pricing/reward signal design, and propose a distributed stochastic dual algorithm for solving the reformulated problem while restoring feasible power rates for discrete devices. By doing so, we are able to statistically achieve the solution of the reformulated problem without exposure of any private information from customers. Stability of the proposed schemes is analytically established and numerically corroborated.
The structural integrity of the concrete biological shield (CBS) in light water reactors (LWRs) exposed to long-term radiation raises the question of the effects of fast-neutron and gamma irradiation on the bond properties of embedded carbon-steel reinforcement in concrete, which is critical to the transfer of in-service and accidental loads. The design and execution of a first-of-a-kind irradiation experiment conducted in the LVR-15 test reactor (Czech Republic) are presented along with preliminary post-irradiation examination and testing results. Preliminary analysis shows that the fast neutron flux affects the radiation-induced volumetric of concrete aggregate, that the gamma irradiation induces shrinkage of the chemically bonded water in cementitious hydrates and that the bond strength of steel in concrete at the tested irradiation conditions decreases moderately.
No abstract prepared.
A system based on a pair of mass flow controllers has been used to evacuate and vent a clean cavity rf space. The mass-flow system is used in both single cavity testing and with the ATLAS upgrade cryomodule at Argonne. It is similar schematically to that already in use at DESY, however, it is very compact and maintains the capability to precisely control both the pump out and venting rates. Initial tests of the system with both the ATLAS single cavity test cryostat and the ATLAS upgrade cryomodule show that pump down and venting cycles may be performed without introducing substantial particulates into the cavity rf space. The system, together with the ANL top loading cryomodule design with easy access to individual cavities, will allow an individual cavity to be removed and replaced in a cryomodule string without the need to re-clean the entire string. This capability would also remove the need to test every cavity individually before installation into the string, constituting a major savings for large projects.
Wind turbines are designed using a set of simulations to determine the structural loads that the turbine could experience. These structural loads can be significant influenced by physical turbine parameters. While significant research and effort has been put into measuring and defining such parameters, limited work has been done to quantify the sensitivity of structural loads to uncertainty in the physical turbine parameters. This paper therefore seeks to assess the sensitivity of different turbine aerodynamic parameters on the resulting ultimate and fatigue loads of the turbine during normal operational conditions. Eighteen different turbine parameters are screened using an Elementary Effects approach with radial points. The results show a high sensitivity of the loads to the blade twist and lift coefficient distributions. To a lesser extent, other turbine parameters that drive loads include the maximum lift coefficient location, blade chord length, and drag coefficient distributions.
Minimum mass designs are obtained for a simple box beam structure subject to bending, torque and combined bending/torque load cases. These designs are obtained subject to point strain and linear buckling constraints. The present work differs from previous efforts in that special attention is payed to including the effects of subcomponent panel interaction in the optimal design process. Two different approaches are used to impose the buckling constraints. When the global approach is used, buckling constraints are imposed on the global structure via a linear eigenvalue analysis. This approach allows the subcomponent panels to interact in a realistic manner. The results obtained using this approach are compared to results obtained using a traditional, less expensive approach, called the local approach. When the local approach is used, in-plane loads are extracted from the global model and used to impose buckling constraints on each subcomponent panel individually. In the global cases, it is found that there can be significant interaction between skin, spar, and rib design variables. This coupling is weak or nonexistent in the local designs. It is determined that weight savings of up to 7% may be obtained by using the global approach instead of the local approach to design these structures. Several of the designs obtained using the linear buckling analysis are subjected to a geometrically nonlinear analysis. For the designs which were subjected to bending loads, the innermost rib panel begins to collapse at less than half the intended design load and in a mode different from that predicted by linear analysis. The discrepancy between the predicted linear and nonlinear responses is attributed to the effects of the nonlinear rib crushing load, and the parameter which controls this rib collapse failure mode is shown to be the rib thickness. The rib collapse failure mode may be avoided by increasing the rib thickness above the value obtained from the (linear analysis based) optimizer. It is concluded that it would be necessary to include geometric nonlinearities in the design optimization process if the true optimum in this case were to be found.
Numerical simulations have been completed for a variety of designs for a 90 deg elbow duct. The objective is to identify a design that minimizes the dynamic load entering a LOX turbopump located at the elbow exit. Designs simulated to date indicate that simpler duct geometries result in lower losses. Benchmark simulations have verified that the compressible flow code used in this study is applicable to these incompressible flow simulations.