Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Feasibility of fusion plasma burn control via real-time, sub-divertor neutral gas isotopic and compositional analysis

The ability to provide fusion burn control without requiring physical access through the first wall and fuel breeding blankets, would be vital for any future, magnetically confined fusion power reactor. A multi-sensor, fusion fuel cycle exhaust, neutral gas analysis system on JET, capable of delivering real time data, and accessing only the sub-divertor region, provides an excellent example of such capability. Optimized for and operated during the deuterium–tritium experimental campaigns 2 and 3 (DTE2, DTE3), it is proving valuable for planning to explore fusion reactor burn control in ITER with a comparable diagnostic system called the Diagnostic Residual Gas Analyzer (DRGA). This paper aims to show feasibility of developing model-based controllers for ITER and next generation, reactor-relevant devices, by building both on the empirical experience in JET-DTE2, and on the already emerging experience on developing such models specifically for ITER. The paper begins with a specific use-case from JET-DTE2, pertaining to the observed sensitivity of the fusion neutron yield on the concentration of isotopic helium-3 ( 3 He), with data from one of the high-performance DT shots exhibited with emphasis on the 3 He measurement via the sub-divertor. Then, a first model is developed and then explored with simulations that aim to discover how well the controllers in the model react to either insufficient levels of 3 He or excessive levels of 3 He. The simulations then explore potential impact from a delay in the measurement (or the response) that would be comparable to the ∼1 s, conductance limited response for the ITER DRGA system, currently in its final design. The simulations show that control is feasible, and that its effectiveness is not significantly impacted by such delay.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AI & Physics-Based Bad Command/Data Detection in Large Power Electronics Systems: Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS)

Detection of bad data from measurement sensors and bad commands from control centers need to be carried out to avoid instabilities within large power electronics systems. Towards the same, in this paper, model and data driven methods are proposed to identify anomalies in measured data and commands received by large power electronics systems. The large power electronics system considered in this paper is a multi-port autonomous reconfigurable solar power plant (MARS), which consists of photovoltaic (PV) and energy storage systems (ESSs) that connect to high-voltage direct current (HVdc) system and transmission ac power grid. The proposed algorithms in the MARS power plant to detect bad data from measurements and bad commands from control centers are evaluated in simulations and hardware-in-the-loop (HIL) tests. Furthermore, it has been observed that the proposed algorithms are able to detect bad measurements and commands in all the use cases evaluated.

14 SOLAR ENERGY↗

Quantitative Validation of Control Bands Using Bayesian Statistical Analyses

Abstract This study presents a quantitative validation of 15 Similar Exposure Groups (SEGs) that were derived via control bands inherent to the Risk Level Based Management System currently being used at the Lawrence Livermore National Laboratory. For 93% of the SEGs that were evaluated, statistical analyses of personal exposure monitoring data, through Bayesian Decision Analysis (BDA), demonstrated that the controls implemented from the initial control bands assigned to these SEGs were at least as protective as the controls from the control band outcomes derived from the quantitative data. The BDA also demonstrated that for 40% of the SEGs, the controls from the initial control bands were overly protective, thus allowing controls to be downgraded, which resulted in a significant saving of environmental safety and health (ES&H) resources. Therefore, as a means to both confirm existing controls and to identify candidate SEGs for downgrading controls, efforts to continuously improve the accuracy of Control Banding (CB) strategies through the routine quantitative validation of SEGs are strongly encouraged. Targeted collaborative efforts across institutions and even countries for both the development of CB strategies and the validation of discreetly defined SEGs of commonly performed tasks will not only optimize limited ES&H resources but will also assist in providing a simplified process for essential risk communication at the worker level to the benefit of billions of workers around the world.

McCord, Tyler A.↗

Inrush Current Mitigation for Grid-Forming Inverters in Islanded Microgrids

Virtual-inertia and droop control methods are commonly used for grid-forming inverters. While the virtual inertia is used to emulate the equation of motion/frequency, if the inverter output voltage is emulated as in synchronous generators, then the method is known as the virtual synchronous generator. An inductive pulse-load, e.g., a relatively large induction motor, connection to a microgrid fed only by grid-forming inverters may lead to blackout due to high inrush currents. This article presents virtual reactance techniques to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. This article also compares the virtual inertia and droop control methods under switching inductive-dynamic loads while the proposed techniques are implemented. Experimental tests are performed considering the linear and nonlinear virtual reactance techniques, and the findings are discussed. The mitigation significantly suppresses the inrush currents while the inverters can perform a normal operation. Furthermore, the frequency and power response of the virtual inertia control with different inertia settings to a sudden change in the load is analyzed. The virtual reactance technique is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented in this article.

Gursoy, Mehmetcan↗

PLC-based Impedance Measurement and Current Injection Response Analysis

Studying and mitigating the vulnerabilities of Programmable Logic Controllers (PLCs) to electromagnetic pulse is important for the reliability of the power system. In this paper, an effective impedance measurement scheme is proposed to estimate the susceptibility of PLCs to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulse Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of PLC.

Qiu, Wei↗

Oligosaccharide production and signaling correlate with delayed flowering in an Arabidopsis genotype grown and selected in high [CO 2 ]

Since industrialization began, atmospheric CO 2 ([CO 2 ]) has increased from 270 to 415 ppm and is projected to reach 800–1000 ppm this century. Some Arabidopsis thaliana (Arabidopsis) genotypes delayed flowering in elevated [CO 2 ] relative to current [CO 2 ], while others showed no change or accelerations. To predict genotype-specific flowering behaviors, we must understand the mechanisms driving flowering response to rising [CO 2 ]. [CO 2 ] changes alter photosynthesis and carbohydrates in plants. Plants sense carbohydrate levels, and exogenous carbohydrate application influences flowering time and flowering transcript levels. We asked how organismal changes in carbohydrates and transcription correlate with changes in flowering time under elevated [CO 2 ]. We used a genotype (SG) of Arabidopsis that was selected for high fitness at elevated [CO 2 ] (700 ppm). SG delays flowering under elevated [CO 2 ] (700 ppm) relative to current [CO 2 ] (400 ppm). We compared SG to a closely related control genotype (CG) that shows no [CO 2 ]-induced flowering change. We compared metabolomic and transcriptomic profiles in these genotypes at current and elevated [CO 2 ] to assess correlations with flowering in these conditions. While both genotypes altered carbohydrates in response to elevated [CO 2 ], SG had higher levels of sucrose than CG and showed a stronger increase in glucose and fructose in elevated [CO 2 ]. Both genotypes demonstrated transcriptional changes, with CG increasing genes related to fructose 1,6-bisphosphate breakdown, amino acid synthesis, and secondary metabolites; and SG decreasing genes related to starch and sugar metabolism, but increasing genes involved in oligosaccharide production and sugar modifications. Genes associated with flowering regulation within the photoperiod, vernalization, and meristem identity pathways were altered in these genotypes. Elevated [CO 2 ] may alter carbohydrates to influence transcription in both genotypes and delayed flowering in SG. Changes in the oligosaccharide pool may contribute to delayed flowering in SG. This work extends the literature exploring genotypic-specific flowering responses to elevated [CO 2 ].

59 BASIC BIOLOGICAL SCIENCES↗

Dynamic, resilient virtual sensing system and shadow controller for cyber-attack neutralization

An industrial asset may have monitoring nodes (e.g., sensor or actuator nodes) that generate current monitoring node values. An abnormality detection and localization computer may receive the series of current monitoring node values and output an indication of at least one abnormal monitoring node that is currently being attacked or experiencing a fault. An actor-critic platform may tune a dynamic, resilient state estimator for a sensor node and output tuning parameters for a controller that improve operation of the industrial asset during the current attack or fault. The actor-critic platform may include, for example, a dynamic, resilient state estimator, an actor model, and a critic model. According to some embodiments, a value function of the critic model is updated for each action of the actor model and each action of the actor model is evaluated by the critic model to update a policy of the actor-critic platform.

Roychowdhury, Subhrajit↗

First feedback-controlled divertor detachment in W7-X: Experience from TDU operation and prospects for operation with actively cooled divertor

In the last experimental campaign (OP1.2b) of the stellarator Wendelstein 7-X (W7-X), boronisation as a mean for first wall conditioning was applied for the first time which led to strongly reduced impurity fluxes from plasma-facing components. Thermal detachment at the uncooled target plates of the test divertor unit (TDU) was reached at higher plasma densities and was accompanied by high recycling of neutrals at the target plate. A feedback control system was established in W7-X to actively control the gas injection (actuator) for plasma fuelling and impurity seeding [3] through the divertors. It allowed very successful stabilisation of the detached plasma condition state as well as mitigation of thermal overloads to some baffle tiles. Different routinely available diagnostic signals were used as input parameters (sensors). We describe the setup of the feedback control system, its performance and provide some example results with the main focus on the development of the control scheme which led to the detachment stabilisation over the entire longest (30 s) high-power discharge at W7-X so far. In view of the achieved very successful detachment stabilisation and the necessity to include simultaneous optimisation of the core performance in the future, the feedback control system is being upgraded for the upcoming campaign (OP2.1) in which the water cooled and hereby inherently steady-state capable divertor has been currently installed. The prospects and some experiment ideas for active detachment control are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vulnerability Studies Under EMP: Impedance and PCI Testing of the Grid Control Devices

Control devices such as inverters and generator controllers are critical for the stable operation of the power grid, especially for power stability control and power dispatch. However, the Electromagnetic Pulse (EMP) is a potential threat to electronic devices in modern power grids, therefore decreasing the power grid resilience and bringing unrecoverable damages to the devices. To reveal the impact mechanism of the EMP, impedance and Pulse Current Injection (PCI) testing is established to study the vulnerability of the grid control devices. The impedance of the grid control devices is accurately measured using impedance analyzers with different frequency ranges. Then the voltage and current responses are tested based on the PCI testing. The vulnerability experiments based on two grid control devices are carried out. And the comparison results reveal that most ports would be damaged under EC8, and some ports can survive under EC5 according to the calculated PCI response and cumulative energy. The results can provide a reference for the future design of control devices and the strategic resilience of power grids.

Qiu, Wei↗

Studying electroweak few-body observables in chiral effective field theory

The use of nuclei to study electroweak probes is becoming increasingly relevant experimentally. The success of dark matter and neutrino experiments strongly depends on the ability to control nuclear effects in order to extract the fundamental parameters associated with external probes. Therefore, reliable theoretical calculations of nuclear structure and reactions, with well-controlled errors, are crucial for the success of experimental efforts. Currently, chiral effective field theory ($\chi$EFT) coupled with {\it ab-initio} methods represents one of the best approaches that fulfills these requirements. To use this approach as a tool for studying fundamental physics, it is essential to validate it against experimental data for which the calculations are well under control, such as the elastic scattering of electrons on nuclei. In this proceeding, I will present recent developments in the fitting of electromagnetic currents derived using $\chi$EFT and the calculation of electromagnetic form factors of light nuclei. The results of these calculations demonstrate the strength of the theory in describing the interaction of nuclei with electromagnetic probes over a broad range of momentum transfers and highlight the robustness of $\chi$EFT for analyzing future experimental data aimed at extracting fundamental parameters.

Gnech, Alex [Old Dominion Univ., Norfolk, VA (Unit↗

Controlling Air Conditioners for Frequency Regulation: A Real-World Example

Even though thermostatically controlled loads like air conditioners present a great potential for providing ancillary services to the electric power grid, the practical challenges associated with their real-time coordination have not received the necessary attention. In this work, we present a nondisruptive load control application, specifically, we demonstrate how real residential air conditioners can provide frequency regulation. Aggregate power adjustment is achieved by modifying the ON/OFF modes of the air conditioners. To account for both single and multi-zone houses, we extend the currently available techniques and develop an approach that can be used for controlling aggregations that include both types of houses. A discussion of the practical challenges encountered in our field experiments is provided, along with the hardware and software approaches we developed to circumvent them. Here, we argue that limitations of current thermostat APIs introduce significant challenges and are an impediment to widespread adoption of fast load control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fuel performance evaluation of two high burnup PWR core designs during normal operation, control rod withdrawal, and control rod ejection scenarios

There is interest among utilities to extend the current, 18-month operating cycle to 24 months. Economically, this extension would require greater than 5 % enrichment and peak rod average discharge burnup levels above 62 GWd/MTU. A notable challenge of increasing enrichment is the resulting additional excess reactivity encountered during the early stages of fuel life. To accommodate, burnable absorbers beyond soluble boron are introduced into the fuel system. In high burnup fuels, the possibilities of cladding lift-off and fuel melting increase due, in part, to increased rod internal pressures and limited fuel thermal conductivity, respectively. This work collaboratively employs PARCS, RELAP5-3D, and BISON to compare the fuel performance of two high burnup fuel candidates with higher than 5 % enrichment. Here, the fuel performance parameters were compared to current NRC guidance. The results demonstrate an annular fuel design with homogenously blended gadolinium as a burnable absorber operates with greater safety margins during normal operation, allowing for additional operational flexibility. During normal operation, the core design utilizing Integral Fuel Burnable Absorber pins contained fuel pins which reached plenum pressures above 15.5 MPa by the end of the first fuel cycle and fuel pins experienced cladding hoop strains above 1 %. In the Gd core design, only two observed pins experienced plenum pressures above 15.5 MPa and no pins exceeded 1 % cladding hoop strain. During the control rod withdrawal scenario, plenum pressures for pins in both designs marginally exceeded system pressure, however neither experienced excessive hoop strain. The Gd core design experienced a maximum fuel temperature of 2418 K, which is significantly higher than the Integral Fuel Burnable Absorber design at 2157 K, but still within regulatory guidance. We predicted that the fuel in both could return to service after the CRW event. We also predicted that cladding would not fail during the Control Rod Ejection in either core design. Generally, the Integral Fuel Burnable Absorber core design performed with greater safety margin with regards to temperature during normal operation and the transient events. However, the Gd core design performed with greater safety margin regarding plenum pressure and hoop strain limits during normal operation and both transient events.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scenario optimization for the tokamak ramp-down phase in RAPTOR: Part B. safe termination of DEMO plasmas

An optimized plasma current ramp-down strategy is critical for safe and fast termination of plasma discharges in a tokamak demonstration fusion reactor (DEMO), both in planned and emergency scenarios, avoiding plasma disruptions and excessive heat loads to the first wall. Plasma stability limits and machine-specific technical requirements constrain the stable envelope through which the plasma must be navigated. Large amounts of auxiliary heating are required throughout the ramp-down phase, to avoid a radiative collapse in the presence of intrinsic tungsten and seeded xenon impurities, as quantitatively estimated in this work. As the plasma current is reduced, the current density becomes increasingly peaked, reflected by a growing value of the internal inductance $\ell$ $i3$ , resulting in reduced controllability of the vertical position of the plasma. The feasibility of different plasma current ramp-down rates is tested by applying an automated optimization framework embedding the RAPTOR core transport solver. Optimal time traces for plasma current $I$ $p$ $(t)$ and plasma elongation $κ(t)$ are proposed, to satisfy an $I$ $p$ -dependent upper limit on the plasma internal inductance, as obtained from vertical stability studies using the CREATE-NL code, as well as a constraint on the time evolution of $q$ 95 , to avoid an ideal MHD mode. A negative current density near the plasma edge is observed in our simulations, even for the most conservative $I$ $p$ ramp-down rate, indicating significant transient dynamics due to a large resistive time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Control of Nonlinear Compton Scattering in a Squeezed Vacuum

Electromagnetic radiation by accelerated charges is a fundamental process in physics. Here, we introduce a quantum-optical framework for controlling the emission of radiation of an electron in an intense laser field via squeezed vacuum states. By engineering the quantum fluctuations of the emission modes, we demonstrate that the probability of nonlinear Compton scattering can be significantly enhanced or suppressed through tunable squeezing amplitude and angle. We show numerically that our predictions are experimentally accessible with current squeezing technologies, establishing a new paradigm for quantum control in high-intensity light-matter interactions.

Light-matter interaction↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

A review on protection challenges of Transmission Lines connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses.

14 SOLAR ENERGY↗

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses

14 SOLAR ENERGY↗

Demonstration of INCC6 for advanced list-mode data acquisition and analysis using ALMM

The International Neutron Coincidence Counting (INCC) software plays an important role in nuclear safeguards and nuclear material control and accounting (NMC&A) measurements. While the current version, INCC5, represents the traditional standard utilized by inspectorates as well as facilities and practitioners alongside shift register hardware, LANL has recently developed an upgraded version of the software, INCC6. INCC6 offers the same analysis tools as INCC5 while adding new capabilities including acquisition and analysis of list-mode data, recording and storage of list-mode data files, and an expanded set of advanced analysis tools that make use of the additional information available from list-mode data. Here, this paper presents the first demonstration of data acquisition and analysis using INCC6 and the Advanced List Mode Multiplicity Module (ALMM). The capability of INCC6 to perform live list-mode data acquisition and analysis is demonstrated for a variety of neutron sources with a range of neutron emission rates relevant for practical applications and validated against the results obtained with INCC5 and traditional shift register hardware. Advanced list-mode analysis tools introduced by INCC6, such as time-interval and coincidence matrix analysis, are also demonstrated. Finally, the capability of INCC6 to analyze list-mode data files is tested and validated against traditional shift register results using INCC5.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗