Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coverage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Prospective Clinical Trial of Positron Emission Tomography/Computed Tomography Image-Guided Intensity-Modulated Radiation Therapy for Cervical Carcinoma With Positive Para-Aortic Lymph Nodes

Purpose: To describe a more aggressive treatment technique allowing dose escalation to positive para-aortic lymph nodes (PALN) in patients with cervical cancer, by means of positron emission tomography (PET)/computed tomography (CT)-guided intensity-modulated radiation therapy (IMRT). Here, we describe methods for simulation and planning of these treatments and provide objectives for target coverage as well as normal tissue sparing to guide treatment plan evaluation. Methods and Materials: Patients underwent simulation on a PET/CT scanner. Treatment plans were generated to deliver 60.0 Gy to the PET-positive PALN and 50.0 Gy to the PALN and pelvic lymph node beds. Treatment plans were optimized to deliver at least 95% of the prescribed doses to at least 95% of each target volume. Dose-volume histograms were calculated for normal structures. Results: The plans of 10 patients were reviewed. Target coverage goals were satisfied in all plans. Analysis of dose-volume histograms indicated that treatment plans involved irradiation of approximately 50% of the bowel volume to at least 25.0 Gy, with less than 10% receiving at least 50.0 Gy and less than 1% receiving at least 60.0. With regard to kidney sparing, approximately 50% of the kidney volume received at least 16.0 Gy, less than 5% received at least 50.0 Gy, and less than 1% received at least 60.0 Gy. Conclusions: We have provided treatment simulation and planning methods as well as guidelines for the evaluation of target coverage and normal tissue sparing that should facilitate the more aggressive treatment of cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Effect of Translational and Rotational Errors for Patients Undergoing Image-Guided Stereotactic Body Radiotherapy for Spinal Metastases

Purpose: To investigate the dosimetric effects of translational and rotational patient positioning errors on the treatment of spinal and paraspinal metastases using computed tomography image-guided stereotactic body radiotherapy. The results of this study provide guidance for the treatment planning process and recognition of the dosimetric consequences of daily patient treatment setup errors. Methods and Materials: The data from 20 patients treated for metastatic spinal cancer using image-guided stereotactic body radiotherapy were investigated in this study. To simulate the dosimetric effects of residual setup uncertainties, 36 additional plans (total, 756 plans) were generated for each isocenter (total, 21 isocenters) on the planning computed tomography images, which included isocenter lateral, anteroposterior, superoinferior shifts, and patient roll, yaw, and pitch rotations. Tumor volume coverage and the maximal dose to the organs at risk were compared with those of the original plan. Six daily treatments were also investigated to determine the dosimetric effect with or without the translational and rotational corrections. Results: A 2-mm error in translational patient positioning error in any direction can result in >5% tumor coverage loss and >25% maximal dose increase to the organs at risk. Rotational correction is very important for patients with multiple targets and for the setup of paraspinal patients when the isocenter is away from bony structures. Compared with the original plans, the daily treatment data indicated that translational adjustments could correct most of the setup errors to mean divergences of -1.4% for tumor volume coverage and -0.3% for the maximal dose to the organs at risk. Conclusion: For the best dosimetric results, spinal stereotactic treatments should have setup translational errors of {<=}1 mm and rotational errors of {<=}2 deg.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Larynx-Sparing Techniques With IMRT When Treating the Head and Neck

Purpose: Concern exists that widespread implementation of whole-field intensity-modulated radiotherapy (IMRT) for the treatment of head-and-neck cancer has resulted in increased levels of dysphagia relative to those seen with conventional planning. Other investigators have suggested an alternative junctioned-IMRT (J-IMRT) method, which matches an IMRT plan to a centrally blocked neck field to restrict the laryngeal dose and reduce dysphagia. The effect on target coverage and sparing of organs at risk, including laryngeal sparing, in the optimization was evaluated and compared with that achieved using a J-IMRT technique. Methods and Materials: A total of 13 oropharyngeal cancer whole-field IMRT plans were planned with and without including laryngeal sparing in the optimization. A comparison of the target coverage and sparing of organs at risk was made using the resulting dose-volume histograms and dose distribution. The nine plans with disease located superior to the level of the larynx were replanned using a series of J-IMRT techniques to compare the two laryngeal-sparing techniques. Results: An average mean larynx dose of 29.1 Gy was achieved if disease did not extend to the level of the larynx, with 38.8 Gy for disease extending inferiorly and close to the larynx (reduced from 46.2 and 47.7 Gy, respectively, without laryngeal sparing). Additional laryngeal sparing could be achieved with J-IMRT (mean dose 24.4 Gy), although often at the expense of significantly reduced coverage of the target volume and with no improvement to other areas of the IMRT plan. Conclusion: The benefits of J-IMRT can be achieved with whole-field IMRT if laryngeal sparing is incorporated into the class solution. Inclusion of laryngeal sparing had no effect on other parameters in the plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Planning the Breast Boost: Comparison of Three Techniques and Evolution of Tumor Bed During Treatment

Purpose: To evaluate the accuracy of two clinical techniques for electron boost planning compared with computed tomography (CT)-based planning. Additionally, we evaluated the tumor bed characteristics at whole breast planning and boost planning. Methods and Materials: A total of 30 women underwent tumor bed boost planning within 2 weeks of completing whole breast radiotherapy using three planning techniques: scar-based planning, palpation/clinical-based planning, and CT-based planning. The plans were analyzed for dosimetric coverage of the CT-delineated tumor bed. The cavity visualization score was used to define the CT-delineated tumor bed as well or poorly defined. Results: Scar-based planning resulted in inferior tumor bed coverage compared with CT-based planning, with the minimal dose received by 90% of the target volume >90% in 53% and a geographic miss in 53%. The results of palpation/clinical-based planning were significantly better: 87% and 10% for the minimal dose received by 90% of the target volume >90% and geographic miss, respectively. Of the 30 tumor beds, 16 were poorly defined by the cavity visualization score. Of these 16, 8 were well demarcated by the surgical clips. The evaluation of the 22 well-defined tumor beds revealed similar results. A comparison of the tumor bed volume from the initial planning CT scan to the boost planning CT scan revealed a decrease in size in 77% of cases. The mean decrease in volume was 52%. Conclusion: The results of our study have shown that CT-based planning allows for optimal tumor bed coverage compared with clinical and scar-based approaches. However, in the setting of a poorly visualized cavity on CT without surgical clips, palpation/clinical-based planning can help delineate the appropriate target volumes and is superior to scar-based planning. CT simulation at boost planning could allow for a reduction in the boost volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential Dosimetric Benefits of Four-Dimensional Radiation Treatment Planning

Purpose: To determine the extent of dosimetric differences between conventional three-dimensional (3D) dose calculations and four-dimensional (4D) dose calculations based on deformation of organ models. Methods and Materials: Four-dimensional dose calculations were retrospectively performed on computed tomography data sets for 15 patients with Stage III non-small-cell lung cancer, using a model-based deformable registration algorithm on a research version of a commercial radiation treatment planning system. Target volume coverage and doses to critical structures calculated using the 4D methodology were compared with those calculated using conventional 3D methodology. Results: For 11 of 15 patients, clinical target volume coverage was comparable in the 3D and 4D calculations, whereas for 7 of 15 patients, planning target volume coverage was comparable. For the other patients, the 4D calculation indicated a difference in target volume dose sufficiently great to warrant replanning. No correlations could be established between differences in 3D and 4D calculations and gross tumor volume size or extent of motion. Negligible differences were observed between 3D and 4D dose-volume relationships for normal anatomic structures. Conclusions: Use of 4D dose calculations, when possible, helps ensure that target volumes will not be underirradiated when respiratory motion may affect the dose distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pelvic Radiotherapy for Cancer of the Cervix: Is What You Plan Actually What You Deliver?

Purpose: Whole pelvic intensity-modulated radiotherapy (IMRT) is increasingly being used to treat cervix cancer and other gynecologic tumors. However, tumor and normal organ movement during treatment can substantially detract from the benefits of this approach. This study explored the effect of internal anatomic changes on the dose delivered to the tumor and organs at risk using a strategy integrating deformable soft-tissue modeling with simulated dose accumulation. Methods and Materials: Twenty patients with cervix cancer underwent baseline and weekly pelvic magnetic resonance imaging during treatment. Interfraction organ motion and delivered (accumulated) dose was modeled for three treatment scenarios: four-field box, large-margin whole pelvic IMRT (20-mm planning target volume, but 10 mm inferiorly) and small-margin IMRT (5-mm planning target volume). Results: Individually, the planned dose was not the same as the simulated delivered dose; however, when taken as a group, this was not statistically significant for the four-field box and large-margin IMRT plans. The small-margin IMRT plans yielded adequate target coverage in most patients; however, significant target underdosing occurred in 1 patient who displayed excessive, unpredictable internal target movement. The delivered doses to the organs at risk were significantly reduced with the small-margin plan, although substantial variability was present among the patients. Conclusion: Simulated dose accumulation might provide a more accurate depiction of the target and organ at risk coverage during fractionated whole pelvic IMRT for cervical cancer. The adequacy of primary tumor coverage using 5-mm planning target volume margins is contingent on the use of daily image-guided setup.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison Between Hybrid Direct Aperture Optimized Intensity-Modulated Radiotherapy and Forward Planning Intensity-Modulated Radiotherapy for Whole Breast Irradiation

Purpose: To investigate the planning efficiency and dosimetric characteristics of hybrid direct aperture optimized (hDAO) intensity-modulated radiotherapy (IMRT) compared with forward planning (FP)-IMRT for whole breast irradiation with two tangential beams. Methods and Materials: A total of 15 patients with left-sided breast cancer, categorized with three different breast volumes, were selected for this study. All patients were treated with FP plans to 50 Gy in 25 fractions. The hDAO plans were created by combining two open fields with eight segments in two tangential beam directions and were inversely optimized. Results: The FP and hDAO plans achieved similar breast coverage and sparing of critical organs. The volume of breast receiving 105% of the prescription dose was significantly smaller in the hDAO than in the FP plans: 25% vs. 63% (p = .008) for small, 22% vs. 57% (p = .005) for medium, and 28% vs. 53% (p = .005) for large breasts. Furthermore, the tumor cavity coverage was slightly better in the hDAO plans (92.4% vs. 90.9%). Conclusion: Compared with FP-IMRT, hDAO-IMRT provided dosimetric advantages, significantly reducing the size of the hot spot and slightly improving the coverage of the tumor cavity. In addition, hDAO-IMRT required less planning time and was less dependent on the planner's ability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Soft-Tissue Implanted Markers and Bony Anatomy Alignments for Image-Guided Treatments of Head-and-Neck Cancers

Purpose: To compare the geometric alignments of soft-tissue implanted markers to the traditional bony-based alignments in head-and-neck cancers, on the basis of daily image guidance. Dosimetric impact of the two alignment techniques on target coverage is presented. Methods and Materials: A total of 330 retrospective alignments (5 patients) were performed on daily megavoltage computed tomography (MVCT) image sets using both alignment techniques. Intermarker distances were tracked for all fractions to assess marker interfractional stability. Using a deformable image registration algorithm, target cumulative doses were calculated according to generated shifts on daily MVCT image sets. Target D95 was used as a dosimetric endpoint to evaluate each alignment technique. Results: Intermarker distances overall were stable, with a standard deviation of <1.5 mm for all fractions and no observed temporal trends. Differences in shift magnitudes between both alignment techniques were found to be statistically significant, with a maximum observed difference of 8 mm in a given direction. Evaluation of technique-specific dose coverage based on D95 of target clinical target volume and planning target volume shows small differences (within +-5%) compared with the kilovoltage CT plan. Conclusion: The use of daily MVCT imaging demonstrates that implanted markers in oral tongue and soft-palate cancers are stable localization surrogates. Alignments based on implanted markers generate shifts comparable overall to the traditional bony-based alignment, with no observed systematic difference in magnitude or direction. The cumulative dosimetric impact on target clinical target volume and planning target volume coverage was found to be similar, despite large observed differences in daily alignment shifts between the two techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Volumetric Modulated Arc Therapy and Conventional Intensity-Modulated Radiotherapy for Frontal and Temporal High-Grade Gliomas

Purpose: Volumetric modulated arc therapy (VMAT), the predecessor to Varian's RapidArc, is a novel extension of intensity-modulated radiotherapy (IMRT) wherein the dose is delivered in a single gantry rotation while the multileaf collimator leaves are in motion. Leaf positions and the weights of field samples along the arc are directly optimized, and a variable dose rate is used. This planning study compared seven-field coplanar IMRT (cIMRT) with VMAT for high-grade gliomas that had planning target volumes (PTVs) overlapping organs at risk (OARs). Methods and Materials: 10 previously treated patients were replanned to 60 Gy in 30 fractions with cIMRT and VMAT using the following planning objectives: 98% of PTV covered by 95% isodose without violating OAR and hotspot dose constraints. Mean OAR doses were maximally decreased without reducing PTV coverage or violating hotspot constraints. We compared dose-volume histogram data, monitor units, and treatment times. Results: There was equivalent PTV coverage, homogeneity, and conformality. VMAT significantly reduced maximum and mean retinal, lens, and contralateral optic nerve doses compared with IMRT (p < 0.05). Brainstem, chiasm, and ipsilateral optic nerve doses were similar. For 2-Gy fractions, mean monitor units were as follows: cIMRT = 789 +- 112 and VMAT = 363 +- 45 (relative reduction 54%, p = 0.002), and mean treatment times (min) were as follows: cIMRT = 5.1 +- 0.4 and VMAT = 1.8 +- 0.1 (relative reduction 65%, p = 0.002). Conclusions: Compared with cIMRT, VMAT achieved equal or better PTV coverage and OAR sparing while using fewer monitor units and less time to treat high-grade gliomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiotherapy Optimization in a Quasi-Periodically Deforming Patient Model

Purpose: To present the implementation of a probability-based, four-dimensional (4D) intensity-modulated radiotherapy (IMRT) planning approach that explicitly optimizes the accumulated dose to moving tissue, estimated using the patient's probability density function (pdf) of respiratory motion. This is termed 'optimization in tissue's-eye-view'. Methods and Materials: The method incorporates 4D Monte Carlo dose calculation in multiple geometries of a respiratory-correlated CT dataset. The instance doses are weighted according to the breathing pdf and accumulated in a common reference geometry, which involves dose warping based on deformable registration. The algorithm produces deliverable multileaf collimator segments and was tested on a sample lung cancer patient dataset with large target excursion. Accumulated doses of the moving target and organs at risk of this plan were compared with those of corresponding margin-based static IMRT plans for free-breathing and gated treatment, as well as target tracking. Results: Target tracking provided best target coverage. Both the presented 4D IMRT approach for free-breathing treatment and gated treatment gave similar results for target coverage and lung dose, with significantly better target coverage than the margin-based static IMRT plan for free-breathing treatment. Conclusions: The presented 4D planning concept offers an alternative to gating by providing the optimal dose for free-breathing IMRT treatment. Although the focus of this study was 4D lung planning, the approach can be generally applied for IMRT optimization in randomly deforming patient models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Methods to Reduce Dose to Swallowing-Related Structures in Head and Neck Cancer

Introduction: Emerging data suggest that reduction of dose to the larynx and pharyngeal constrictor may lower the risk of swallowing complications such as long-term gastrostomy dependence and aspiration. Organ avoidance becomes difficult when the primary tumor or involved nodes are present at the level of the larynx. Materials and Methods: Fifteen patients with Stage III-IV squamous cell carcinoma of the head and neck with high-dose target volume at the level of the larynx (but not involving the glottic larynx) were planned with whole-field IMRT (WF-IMRT), as well as a low anterior neck field dynamically matched to an IMRT plan (D-SCLV). Plans were compared with respect to coverage of targets and sparing of normal tissues including the larynx, inferior pharyngeal constrictor (IPC), parotid, and cord. Results: There was no significant difference between the two techniques in coverage of the high- or intermediate-dose planning target volumes (PTVs). Coverage of the elective nodal PTV was inferior with the D-SCLV technique, with a mean of 96.5% vs. 86.3% of the volume receiving the prescription dose (p = 0.001) compared with WF-IMRT plans. However, the D-SCLV technique significantly reduced mean dose to the larynx (43.7 vs. 46.7 Gy, p = 0.05) and IPC (39.1 vs. 46.1 Gy, p = 0.002). There was no significant difference in dose to the parotid or cord. Conclusion: Given the steep dose responses seen in studies examining the association between swallowing toxicity and dose to the larynx and IPC, dose reductions using the D-SCLV technique may be clinically significant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Value of Combined PET/CT for Radiation Planning in CT-Guided Percutaneous Interstitial High-Dose-Rate Single-Fraction Brachytherapy for Colorectal Liver Metastases

Purpose: To determine the additional value of fluorodeoxyglucose-positron emission tomography (PET) for clinical target volume definition in the planning of computed tomography (CT)-guided interstitial brachytherapy for liver metastases. Patients and Methods: A total of 19 patients with liver metastases from colorectal cancer treated in 25 sessions were included in the present study. All patients had undergone fluorodeoxyglucose-PET for patient evaluation before interstitial CT-guided brachytherapy. A contrast-enhanced CT scan of the upper abdomen was obtained for radiation planning. The clinical target volume (CTV) was defined by a radiation oncologist and radiologist. After registration of the CT scan with the PET data set, the target volume was defined again using the fusion images. Results: PET revealed one additional liver lesion that was not visible on CT. The median CT-CTV (defined using CT and magnetic resonance imaging) was 68 cm{sup 3} (range 4-260). The PET/CT-CTV (median, 78 cm{sup 3}; range, 4-273) was significantly larger, with a median gain of 24.5% (interquartile range, 2.1-71.5%; p = .022). An increased CTV was observed in 15 cases and a decrease in 6; in 4 cases, the CT-CTV and PET/CT-CTV were equal. Incomplete dose coverage of PET/CT-CTVs was indicative of early local progression (p = .004); however, CT-based radiation plans did not show significant differences in the local control rates when stratified by dose coverage. Conclusion: Retrospective implementation of fluorodeoxyglucose-PET for CTV specification for CT-guided brachytherapy for colorectal liver metastases revealed a significant change in the CTVs. Additional PET-positive tumor regions with incomplete dose coverage could explain unexpected early local progression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Weekly Replanning for Intensity-Modulated Radiotherapy of Cervix Cancer

Purpose: The adoption of intensity-modulated radiotherapy (IMRT) to treat cervical malignancies has been limited in part by complex organ and tumor motion during treatment. This study explores the limits of a highly adaptive, small-margin treatment scenario to accommodate this motion. In addition, the dosimetric consequences of organ and tumor motion are modeled using a combination of deformable registration and fractional dose accumulation techniques. Methods and Materials: Thirty-three cervix cancer patients had target volumes and organs-at-risk contoured on fused, pretreatment magnetic resonance-computed tomography images and weekly magnetic resonance scans taken during treatment. The dosimetric impact of interfraction organ and target motion was compared for two hypothetical treatment scenarios: a 3-mm margin plan with no replanning, and a 3-mm margin plan with an automated replan performed on the updated weekly patient geometry. Results: Of the 33 patients, 24 (73%) met clinically acceptable target coverage (98% of the clinical target volume receiving at least 95% of the prescription dose) using the 3-mm margin plan without replanning. The range in dose to 98% of the clinical target volume across all patients was 7.9% of the prescription dose if no replanning was performed. After weekly replanning, this range was tightened to 2.6% of the prescription dose and all patients met clinically acceptable target coverage while maintaining organ-at-risk dose sparing. Conclusions: The dosimetric impact of anatomical motion underscores the challenges of applying IMRT to treat cervix cancer. An appropriate adaptive strategy can ensure target coverage for small-margin IMRT treatments and maintain favorable organ-at-risk dose sparing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton Therapy for Malignant Pleural Mesothelioma After Extrapleural Pleuropneumonectomy

Purpose: To perform comparative planning for intensity-modulated radiotherapy (IMRT) and proton therapy (PT) for malignant pleural mesothelioma after radical surgery. Methods and Materials: Eight patients treated with IMRT after extrapleural pleuropneumonectomy (EPP) were replanned for PT, comparing dose homogeneity, target volume coverage, and mean and maximal dose to organs at risk. Feasibility of PT was evaluated regarding the dose distribution with respect to air cavities after EPP. Results: Dose coverage and dose homogeneity of the planning target volume (PTV) were significantly better for PT than for IMRT regarding the volume covered by >95% (V95) for the high-dose PTV. The mean dose to the contralateral kidney, ipsilateral kidney, contralateral lung, liver, and heart and spinal cord dose were significantly reduced with PT compared with IMRT. After EPP, air cavities were common (range, 0-850 cm{sup 3}), decreasing from 0 to 18.5 cm{sup 3}/day. In 2 patients, air cavity changes during RT decreased the generalized equivalent uniform dose (gEUD) in the case of using an a value of < - 10 to the PTV2 to <2 Gy in the presence of changing cavities for PT, and to 40 Gy for IMRT. Small changes were observed for gEUD of PTV1 because PTV1 was reached by the beams before air. Conclusion: Both PT and IMRT achieved good target coverage and dose homogeneity. Proton therapy accomplished additional dose sparing of most organs at risk compared with IMRT. Proton therapy dose distributions were more susceptible to changing air cavities, emphasizing the need for adaptive RT and replanning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of Setup Errors and Shape Changes on Breast Radiotherapy

Purpose: The purpose of the present study was to quantify the robustness of the dose distributions from three whole-breast radiotherapy (RT) techniques involving different levels of intensity modulation against whole patient setup inaccuracies and breast shape changes. Methods and Materials: For 19 patients (one computed tomography scan and five cone beam computed tomography scans each), three treatment plans were made (wedge, simple intensity-modulated RT [IMRT], and full IMRT). For each treatment plan, four dose distributions were calculated. The first dose distribution was the original plan. The other three included the effects of patient setup errors (rigid displacement of the bony anatomy) or breast errors (e.g., rotations and shape changes of the breast with respect to the bony anatomy), or both, and were obtained through deformable image registration and dose accumulation. Subsequently, the effects of the plan type and error sources on target volume coverage, mean lung dose, and excess dose were determined. Results: Systematic errors of 1-2 mm and random errors of 2-3 mm (standard deviation) were observed for both patient- and breast-related errors. Planning techniques involving glancing fields (wedge and simple IMRT) were primarily affected by patient errors ({approx}6% loss of coverage near the dorsal field edge and {approx}2% near the skin). In contrast, plan deterioration due to breast errors was primarily observed in planning techniques without glancing fields (full IMRT, {approx}2% loss of coverage near the dorsal field edge and {approx}4% near the skin). Conclusion: The influences of patient and breast errors on the dose distributions are comparable in magnitude for whole breast RT plans, including glancing open fields, rendering simple IMRT the preferred technique. Dose distributions from planning techniques without glancing open fields were more seriously affected by shape changes of the breast, demanding specific attention in partial breast planning techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Comparison of Three-Dimensional Conformal Proton Radiotherapy, Intensity-Modulated Proton Therapy, and Intensity-Modulated Radiotherapy for Treatment of Pediatric Craniopharyngiomas

Purpose: Cranial irradiation in pediatric patients is associated with serious long-term adverse effects. We sought to determine whether both three-dimensional conformal proton radiotherapy (3D-PRT) and intensity-modulated proton therapy (IMPT) compared with intensity-modulated radiotherapy (IMRT) decrease integral dose to brain areas known to harbor neuronal stem cells, major blood vessels, and other normal brain structures for pediatric patients with craniopharyngiomas. Methods and Materials: IMRT, forward planned, passive scattering proton, and IMPT plans were generated and optimized for 10 pediatric patients. The dose was 50.4 Gy (or cobalt Gy equivalent) delivered in 28 fractions with the requirement for planning target volume (PTV) coverage of 95% or better. Integral dose data were calculated from differential dose-volume histograms. Results: The PTV target coverage was adequate for all modalities. IMRT and IMPT yielded the most conformal plans in comparison to 3D-PRT. Compared with IMRT, 3D-PRT and IMPT plans had a relative reduction of integral dose to the hippocampus (3D-PRT, 20.4; IMPT, 51.3%{sup Asterisk-Operator }), dentate gyrus (27.3, 75.0%{sup Asterisk-Operator }), and subventricular zone (4.5, 57.8%{sup Asterisk-Operator }). Vascular organs at risk also had reduced integral dose with the use of proton therapy (anterior cerebral arteries, 33.3{sup Asterisk-Operator }, 100.0%{sup Asterisk-Operator }; middle cerebral arteries, 25.9%{sup Asterisk-Operator }, 100%{sup Asterisk-Operator }; anterior communicating arteries, 30.8{sup Asterisk-Operator }, 41.7%{sup Asterisk-Operator }; and carotid arteries, 51.5{sup Asterisk-Operator }, 77.6{sup Asterisk-Operator }). Relative reduction of integral dose to the infratentorial brain (190.7{sup Asterisk-Operator }, 109.7%{sup Asterisk-Operator }), supratentorial brain without PTV (9.6, 26.8%{sup Asterisk-Operator }), brainstem (45.6, 22.4%{sup Asterisk-Operator }), and whole brain without PTV (19.4{sup Asterisk-Operator }, 34.4%{sup Asterisk-Operator }) were recorded with the use of proton therapy. ({sup Asterisk-Operator }Differences were significant based on Friedman's test with Bonferroni-Dunn correction, {alpha} = 0.05) Conclusions: The current study found that proton therapy was able to avoid excess integral radiation dose to a variety of normal structures at all dose levels while maintaining equal target coverage. Future studies will examine the clinical benefits of these dosimetric advantages.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Radiotherapy Techniques (IMRT vs. 3D-CRT) on Outcome in Patients With Intermediate-Risk Rhabdomyosarcoma Enrolled in COG D9803-A Report From the Children's Oncology Group

Purpose: To compare the dosimetric parameters of intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) in patients with intermediate-risk rhabdomyosarcoma and to analyze their effect on locoregional control and failure-free survival (FFS). Methods and Materials: The study population consisted of 375 patients enrolled in the Children's Oncology Group protocol D9803 study, receiving IMRT or 3D-CRT. Dosimetric data were collected from 179 patients with an available composite plan. The chi-square test or Fisher's exact test was used to compare the patient characteristics and radiotherapy parameters between the two groups. The interval-to-event outcomes were estimated using the Kaplan-Meier method and compared using log-rank tests. Cox proportional hazards regression analysis was used to examine the effect of the treatment technique on FFS after adjusting for primary site and risk group. Results: The median follow-up time was 5.7 and 4.2 years for patients receiving 3D-CRT and IMRT, respectively. No differences in the 5-year failure of locoregional control (18% vs. 15%) or FFS (72% vs. 76%) rates were noted between the two groups. Multivariate analysis revealed no association between the two techniques and FFS. Patients with primary tumors in parameningeal sites were more likely to receive IMRT than 3D-CRT. IMRT became more common during the later years of the study. Patients receiving IMRT were more likely to receive >50 Gy, photon energy of {<=}6 MV, and >5 radiation fields than those who received 3D-CRT. The coverage of the IMRT planning target volume by the prescription dose was improved compared with the coverage using 3D-CRT with similar target dose heterogeneity. Conclusions: IMRT improved the target dose coverage compared with 3D-CRT, although an improvement in locoregional control or FFS could not be demonstrated in this population. Future studies comparing the integral dose to nontarget tissue and late radiation toxicity between the two groups are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postoperative Radiotherapy in Prostate Cancer: The Case of the Missing Target

Purpose: Postoperative radiotherapy (XRT) increases survival in high-risk prostate cancer patients. Approximately 50% of patients on long-term follow-up relapse despite adjuvant XRT and the predominant site of failure remains local. Four consensus guidelines define postoperative clinical target volume (CTV) in prostate cancer. We explore the possibility that inadequate CTV coverage is an important cause of local failure. This study evaluates the utility of preoperative magnetic resonance imaging (MRI) in defining prostate bed CTV. Methods and Materials: Twenty prostate cancer patients treated with postoperative XRT who also had preoperative staging MRI were included. The four guidelines were applied and the CTVs were expanded to create planning target volumes (PTVs). Preoperative MRIs were fused with postoperative planning CT scans. MRI-based prostate and gross visible tumors were contoured. Three-dimensional (3D) conformal four- and six-field XRT plans were developed and dose-volume histograms analyzed. Subtraction analysis was conducted to assess the adequacy of prostate/gross tumor coverage. Results: Gross tumor was visible in 18 cases. In all 20 cases, the consensus CTVs did not fully cover the MRI-defined prostate. On average, 35% of the prostate volume and 32% of the gross tumor volume were missed using six-field 3D treatment plans. The entire MRI-defined gross tumor volume was completely covered in only two cases (six-field plans). The expanded PTVs did not cover the entire prostate bed in 50% of cases. Prostate base and mid-zones were the predominant site of inadequate coverage. Conclusions: Current postoperative CTV guidelines do not adequately cover the prostate bed and/or gross tumor based on preoperative MRI imaging. Additionally, expanded PTVs do not fully cover the prostate bed in 50% of cases. Inadequate CTV definition is likely a major contributing factor for the high risk of relapse despite adjuvant XRT. Preoperative imaging may lead to more accurate CTV definition, which should result in further improvements in survival for patients with high-risk prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗