At least 739 records · Page 41

Cooling requirements for the vertical shear instability in protoplanetary disks

The vertical shear instability (VSI) offers a potential hydrodynamic mechanism for angular momentum transport in protoplanetary disks (PPDs). The VSI is driven by a weak vertical gradient in the disk’s orbital motion, but must overcome vertical buoyancy, a strongly stabilizing influence in cold disks, where heating is dominated by external irradiation. Rapid radiative cooling reduces the effective buoyancy and allows the VSI to operate. We quantify the cooling timescale t{sub c} needed for efficient VSI growth, through a linear analysis of the VSI with cooling in vertically global, radially local disk models. We find the VSI is most vigorous for rapid cooling with t{sub c}<Ω{sub K}{sup −1}h|q|/(γ−1) in terms of the Keplerian orbital frequency, Ω{sub K}, the disk’s aspect-ratio, h≪1, the radial power-law temperature gradient, q, and the adiabatic index, γ. For longer t{sub c}, the VSI is much less effective because growth slows and shifts to smaller length scales, which are more prone to viscous or turbulent decay. We apply our results to PPD models where t{sub c} is determined by the opacity of dust grains. We find that the VSI is most effective at intermediate radii, from ∼5 to ∼50 AU with a characteristic growth time of ∼30 local orbital periods. Growth is suppressed by long cooling times both in the opaque inner disk and the optically thin outer disk. Reducing the dust opacity by a factor of 10 increases cooling times enough to quench the VSI at all disk radii. Thus the formation of solid protoplanets, a sink for dust grains, can impede the VSI.

79 ASTRONOMY AND ASTROPHYSICS↗

Ground-state cooling enabled by critical coupling and dark entangled states

Here, we analyze the cooling of a mechanical resonator coupled to an ensemble of interacting two-level systems via an open quantum systems method. Using an exact analytical result, we find optimal cooling occurs when the phonon mode is critically coupled (γ ~ g) to the two-level system ensemble. Typical systems operate in suboptimal cooling regimes due to the intrinsic parameter mismatch (γ $\gg$ g) between the dissipative decay rate γ and the coupling factor g . To overcome this obstacle, we show that carefully engineering the coupling parameters through the strain profile of the mechanical resonator allows phonon cooling to proceed through the dark (subradiant) entangled states of an interacting ensemble, thereby resulting in optimal phonon cooling. Our findings provide an avenue for ground-state cooling and should be accessible for experimental demonstrations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Demonstration of Hadron Beam Cooling Using Radio-Frequency Accelerated Electron Bunches

Cooling of beams of gold ions using electron bunches accelerated with radio-frequency systems was recently experimentally demonstrated in the Relativistic Heavy Ion Collider at Brookhaven National Laboratory. Such an approach is new and opens the possibility of using this technique at higher energies than possible with electrostatic acceleration of electron beams. The challenges of this approach include generation of electron beams suitable for cooling, delivery of electron bunches of the required quality to the cooling sections without degradation of beam angular divergence and energy spread, achieving the required small angles between electron and ion trajectories in the cooling sections, precise velocity matching between the two beams, high-current operation of the electron accelerator, as well as several physics effects related to bunched-beam cooling. Here we report on the first demonstration of cooling hadron beams using this new approach.

43 PARTICLE ACCELERATORS↗

SiC and GaN Devices With Cryogenic Cooling

This article presents the cryogenically cooled application for wide bandgap (WBG) semiconductor devices. Characteristics of silicon carbide (SiC) and gallium nitride (GaN) at cryogenic temperatures are illustrated. SiC MOSFETs exhibit increased on-state resistance and slower switching speed at cryogenic temperatures. However, cryogenic cooling provides low ambient temperature environment and thus enables the SiC converter to operate at lower junction temperature to achieve higher efficiency compared to room temperature cooling. A cryogenically cooled MW-level SiC inverter prototype is developed and demonstrated the feasibility of operating high-power SiC converter with cryogenic cooling. GaN HEMTs exhibit more than five times on-state resistance reduction and faster switching speed at cryogenic temperatures which makes GaN HEMTs an excellent candidate for cryogenic power electronics applications. The significantly reduced on-state resistance of GaN devices provides the possibility to operate them at a current level much higher than rated current at cryogenic temperatures. A GaN double pulse test (DPT) circuit is constructed and demonstrated that GaN HEMTs can operate at nearly four times of rated current at cryogenic temperatures. Challenges of utilizing WBG device with cryogenic cooling are discussed and summarized.

42 ENGINEERING↗

Passive Cooling of Photovoltaics with Desiccants

As part of efforts to reduce photovoltaic (PV) costs and improve reliability/durability, temperature control needs to be closely examined in a number of ways including novel passive cooling technology. Modest PV module operating temperature reductions can increase PV power output by 10% or more. The higher the operating temperature of a typical PV device, the lower the overall PV conversion efficiency. Because some incident light is converted to heat in PV cells, the PV module heats up (typically 25 degrees C above ambient temperature in full sun), and the overall energy output of the PV system is reduced (typically a 10% power loss for every 20 degrees C to 30 degrees C increase in temperature). We are integrating material on the PV module that adsorbs water from the air at night when the PV module temperature is cool and the relative humidity in the air is typically high. This sorbed water evaporates as the PV module heats up during the day, taking the excess heat with it and thus effectively cooling the PV module (see Fig. 1). Initial experiments with this novel passive cooling have demonstrated that PV module operating temperatures may be reduced nearly 30 degrees C with evaporative cooling. In this paper, we describe 1) novel materials development, 2) initial modeling that predicts how the cooling will work in different environments, and 3) results demonstrating the PV operating temperature reductions achieved to date.

14 SOLAR ENERGY↗

A COMPUTATIONAL AND EXPERIMENTAL STUDY OF METAL AND COVALENT ORGANIC FRAMEWORKS USED IN ADSORPTION COOLING

Metal-organic frameworks (MOFs) have recently attracted enormous interest over the past few years due to their potential applications in energy storage and gas separation. However, there have been few reports on MOFs for adsorption cooling applications. Adsorption cooling technology is an established alternative to mechanical vapor compression refrigeration systems. Adsorption cooling is an excellent alternative in industrial environments where waste heat is available. Applications also include hybrid systems, refrigeration, power-plant dry cooling, cryogenics, vehicular systems and building HVAC. Adsorption based cooling and refrigeration systems have several advantages including few moving parts and negligible power consumption. Key disadvantages include large thermal mass, bulkiness, complex controls, and low COP (0.2-0.5). We explored the use of metal organic frameworks that have very high mass loading and relatively low heats of adsorption, with certain combinations of refrigerants to demonstrate a new type of highly efficient adsorption chiller. An adsorption chiller based on MOFs suggests that a thermally-driven COP>1 may be possible with these materials, which would represent a fundamental breakthrough in performance of adsorption chiller technology. Computational fluid dynamics combined with a system level lumped-parameter model have been used to project size and performance for chillers with a cooling capacity ranging from a few kW to several thousand kW. In addition, a cost model has been developed to project manufactured cost of entire systems. These systems rely on stacked micro/mini-scale architectures to enhance heat and mass transfer. Presented herein are computational and experimental results for hydrophyilic MOFs, fluorophilic MOFs and also flourophilic Covalent-organic frameworks (COFs).

adsorption↗

Epicyclic helical channels for parametric resonance ionization cooling

Proposed next-generation muon colliders will require major technical advances to achieve rapid muon beam cooling requirements. Parametric-resonance Ionization Cooling (PIC) is proposed as the final 6D cooling stage of a high-luminosity muon collider. In PIC, a half-integer parametric resonance causes strong focusing of a muon beam at appropriately placed energy absorbers while ionization cooling limits the beam’s angular spread. Combining muon ionization cooling with parametric resonant dynamics in this way should then allow much smaller final transverse muon beam sizes than conventional ionization cooling alone. One of the PIC challenges is compensation of beam aberrations over a sufficiently wide parameter range while maintaining the dynamical stability with correlated behavior of the horizontal and vertical betatron motion and dispersion. We explore use of a coupling resonance to reduce the dimensionality of the problem and to shift the dynamics away from non-linear resonances. PIC simulations are presented.

43 PARTICLE ACCELERATORS↗

R&D toward a proof-of-principle experiment on optical stochastic cooling at the Fermilab’s IOTA ring

The stochastic-cooling method was invented in the late 70s and played a key role in the accumulation of intense beams of antiprotons for a head-on collision with counter rotating proton beams at 500 GeV in the Super Proton Synchrotron (SPS) at CERN. Such an improvement led to the discovery of the W and Z bosons in 1983. In brief, stochastic cooling relies on recording information (position) associated with short longitudinal slices within the bunch. The radiation is encoded on a radiofrequency (RF) signal, manipulated and used to correct the bunch slices at a later time.The repetitive correction is applied as the beam circulates in the ring ultimately cool the beam.Stochastic cooling has been successfully implemented in several machines for particle cooling and accumulation. Cooling of bunched beams in proton-(anti)proton colliders was challenging due to the high phase-space density of the bunches but was recently demonstrated at the Relativistic Heavy Ion Collider (RHIC).

43 PARTICLE ACCELERATORS↗

An Overview of Non-LWR Vessel Cooling Systems for Passive Decay Heat Removal (Technical Letter Final Report)

The following report provides a technical review of various reactor vessel cooling system (VCS) concepts under consideration for decay heat removal (DHR) in non-light water advanced reactor designs. This review focuses on ex-vessel designs, including the Reactor Cavity Cooling System (RCCS), the Reactor Vessel Auxiliary Cooling System (RVACS), and hybrid iterations, using both air and water cooling to achieve their heat removal function. Based on a literature review of publicly available sources published between 1979 and 2021, a technical summary is presented detailing existing and planned VCS design options, their applicability to specific reactor type, and review of authored research and development studies. Following an assessment of the availability of data and modeling tools, an evaluation was performed analyzing their likely performance during normal, degraded, and accident conditions, including reliability, stability, and longevity. With renewed consideration of air-based DHR systems by some US vendors, there is a need to fully understand the complexities inherent to natural circulation systems, and more importantly, how they may influence safety-related heat removal functions and system performance. For DHR systems that rely on air-based mode of cooling, this entails quantification of the impacts of low flow conditions during start-up, relative elevations of inlet and outlet ducts for below-grade installations, effects of the use of multiple parallel chimneys for redundancy, and impact of weather conditions at the plant site. For systems relying on water-based mode cooling, reliance on limited coolant inventory in an event of pipe break or extended duration accident scenarios, sensitivities related to stability of boiling flow and heat transfer conditions, and quantification of full-scale structural vibrations on balance of plant structures are among the complicating factors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Studies of Conventional and ERL-Based Re-Circulator Electron Cooling for an Electron Ion Collider (Final Report)

The envisioned Electron Ion Collider will be comprised of a chain of accelerators, each employing electron cooling. Depending on the purpose, each accelerator will employ some form of electron cooling: conventional DC type, Energy Recovering Linac-based recirculator, or coherent electron cooling. Each electron cooling type has its own peculiarities that need to be studied, understood, and their performance optimized to maximize luminosity; these are the subjects of this project. In particular, we developed the first microscopic electron cooling modeling and simulation framework that was also benchmarked against experiment. We proved for the first time the feasibility of first principle, accurate and efficient electron cooling simulations with a minimal number of assumptions and approximations that match empirical studies.

43 PARTICLE ACCELERATORS↗

Investigation of Solar Cooling Cogeneration Plant

The deficiency in the energy for the space cooling is overcome by solar energy. Still the input energy is minimized by integrating both power and cooling cycle in common platform, such as working fluid, component and working parameters. The aqua-ammonia is used in both power cycle and vapor cooling cycle. The generator is common for cycles for the production of ammonia vapor. The analyses are made to find out the operational parameters for the cooling cogeneration cycle with solar as source. The analyses are done for the proposed cycle with various atmosphere temperatures. At absorber concentration of 0.42 and turbine inlet concentration of 0.90, with solar collector exit temperature of 155°C and atmosphere temperature of 30°C the generated power and cooling are 21.88 and 215.79 kW, respectively. The power and cooling output range can alter by varying turbine inlet concentration and temperature.

14 SOLAR ENERGY↗

Time-dependent Cooling in Photoionized Plasma

I explore the thermal evolution and ionization states in gas cooling from an initially hot state in the presence of external photoionizing radiation. I compute the equilibrium and nonequilibrium cooling efficiencies, heating rates, and ion fractions for low-density gas cooling while exposed to the ionizing metagalactic background radiation at various redshifts ( z = 0 − 3), for a range of temperatures (10{sup 8}–10{sup 4} K), densities (10{sup −7}–10{sup 3} cm{sup −3}), and metallicities (10{sup −3}–2 times solar). The results indicate the existence of a threshold ionization parameter, above which the cooling efficiencies are very close to those in photoionization equilibrium (so that departures from equilibrium may be neglected), and below which the cooling efficiencies resemble those in collisional time-dependent gas cooling with no external radiation (and are thus independent of density).

79 ASTRONOMY AND ASTROPHYSICS↗

Real-Time Closed Loop Modulated Turbine Cooling

It has been noted by industry that in addition to dramatic variations of temperature over a given blade surface, blade-to-blade variations also exist despite identical design. These variations result from manufacturing variations, uneven wear and deposition over the life of the part as well as limitations in the uniformity of coolant distribution in the baseline cooling design. It is proposed to combine recent advances in optical sensing, actuation, and film cooling concepts to develop a workable active, closed-loop modulated turbine cooling system to improve by 10 to 20 the turbine thermal state over the flight mission, to improve engine life and to dramatically reduce turbine cooling air usage and aircraft fuel burn. A reduction in oxides of nitrogen (NOx) can also be achieved by using the excess coolant to improve mixing in the combustor especially for rotorcraft engines. Recent patents filed by industry and universities relate to modulating endwall cooling using valves. These schemes are complex, add weight and are limited to the endwalls. The novelty of the proposed approach is twofold 1) Fluidic diverters that have no moving parts are used to modulate cooling and can operate under a wide range of conditions and environments. 2) Real-time optical sensing to map the thermal state of the turbine has never been attempted in realistic engine conditions.

turbines↗

Thermospheric Nitric Oxide Cooling Responses to the 14 December 2020 Solar Eclipse

The behaviors of the nitric oxide (NO) cooling in the lower thermosphere during the 14 December 2020 solar eclipse are studied using Sounding of the Atmosphere using Broadband Emission Radiometry (SABER) measurements and WACCM-X simulations. We found that NO cooling rate decreases during the solar eclipse in both SABER measurements and WACCM-X simulations. The maximum decrease of the NO cooling is 40% in SABER measurements and 25% in WACCM-X simulations. The NO cooling process is initiated almost entirely through the collisions with atomic oxygen (O) which depends linearly on NO and O densities and non-linearly on the neutral temperature. During the eclipse, the NO concentration and temperature decreases are larger than that of O concentration. Consequently, the eclipse-time NO concentration and temperature decreases are the major drivers of the NO cooling rate decrease. The decreases of the temperature and the NO concentration contribute comparably to the eclipse-time NO cooling rate decrease.

solar eclipse↗

Electron Cooling Study for MEIC

Electron cooling of the ion beams is one critical R&D to achieve high luminosities in JLab's MEIC proposal. In the present MEIC design, a multi-staged cooling scheme is adapted, which includes DC electron cooling in the booster ring and bunched beam electron cooling in the collider ring at both the injection energy and the collision energy. We explored the feasibility of using both magnetized and non-magnetized electron beam for cooling, and concluded that a magnetized electron beam is necessary. Electron cooling simulation results for the newly updated MEIC design is also presented.

43 PARTICLE ACCELERATORS↗

Hybrid Geothermal Heat Pumps for Cooling Telecommunications Data Centers

The technical and economic performance of geothermal heat pump (GHP) systems supplying year-round cooling to representative small data centers with cooling loads less than 500 kWth were analyzed and compared to air-source heat pumps (ASHPs). A numerical model was developed in TRNSYS software to simulate the operation of air-source and geothermal heat pumps with and without supplementary air cooled heat exchangers - dry coolers (DCs). The model was validated using data measured at an experimental geothermal system installed in Ithaca, NY, USA. The coefficient of performance (COP) and cooling capacity of the GHPs were calculated over a 20-year lifetime and compared to the performance of ASHPs. The total cost of ownership (TCO) of each of the cooling systems was calculated to assess its economic performance. Both the length of the geothermal borehole heat exchangers (BHEs) and the dry cooler temperature set point were optimized to minimize the TCO of the geothermal systems. Lastly, a preliminary analysis of the performance of geothermal heat pumps for cooling dominated systems was performed for other locations including Dallas, TX, Sacramento, CA, and Minneapolis, MN.

15 GEOTHERMAL ENERGY↗

Two-Phase Cooling for High Packaging Density Planar Inverter: Cooperative Research and Development Final Report, CRADA Number CRD-15-00592

The project objective was to utilize two-phase heat transfer to enable compact and power-dense inverters. The high heat transfer capacity and near isothermal characteristics of two-phase cooling can enable higher power densities, reducing the size and cost of the power electronics system. This project focused on developing efficient, passive (no pump or compressor) two-phase cooling strategies that consist of an air-cooled condenser and evaporator. This report describes the modeling work conducted to design the evaporator and air-cooled condenser for a prototype inverter development work underway in the John Deere. Prototypes of the final evaporator and condenser designs were then fabricated via 3D printing for testing. Experiments on the evaporator confirmed that this component can meet the heat load and junction temperatures requirements for Si IGBT (insulated-gate bipolar transistor) inverter. Experiments with the air-cooled condenser were not possible due to leaks through the condenser walls.

33 ADVANCED PROPULSION SYSTEMS↗

Clean Water Production in Cooling Towers

This project developed and demonstrated a novel technology that produces clean water from cooling tower recirculating water by using the natural evaporation and condensation cycle inside cooling towers. The system captures the escaping plume and converts blowdown quality water into high purity water suitable for on-site reuse such as boiler feed. The technology uses electric fields to ionize exhaust plumes, charge the entrained droplets, and direct them toward collection electrodes where they coalesce and flow downward. This allows water recovery at a low energy cost while reducing visible plume emissions. In addition, we developed a complementary software platform that improves overall cooling tower performance. The system uses wireless sensors and physics-based machine learning algorithms to optimize key parameters of the cooling process. For power generation facilities, this increases the thermal efficiency of the cooling loop and condenser, resulting in measurable cycle efficiency gains. Improvements of one percent or more can deliver significant increases in electricity production for the same fuel input.