Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controllable loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration: Preprint

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Startup Physics Testing of Advanced Reactors

This report documents the startup physics testing from initial fuel loading through ascension to full power for past advanced reactor startup physics testing programs. The review includes an assessment of what nuclear physics data was measured, why this data was measured, how was the measurement made, and the agreement with predictive reactor performance calculations of that time. The purpose of this review is to establish historical precedence for test inclusion for future advanced reactors planned for demonstration at the National Reactor Innovation Center (NRIC). The historical review includes reactor designs considered to be significantly different from current light-water reactor designs, or use simplified, inherent, passive, or other innovative means to accomplish their safety functions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

EVs@Scale Lab Consortium High-Power Charging Pillar Deep-Dive Technical Meeting

Managed under the the U.S. Department of Energy (DOE)-funded EVs@Scale Consortium, the High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project aims to create an experimental platform for integration and control approaches in a direct current (DC), distribution-based high-power charging (HPC) system. The eCHIP project addresses the crucial need to design and validate efficient, low-cost, reliable, and interoperable solutions for a DC-coupled charging hub ("DC hub" for short). This report explains the design, development, and implementation process of an experimental platform for the DC hub. DC distribution holds significant potential for enhancing the operation of an HPC station architecture. However, there are challenges in establishing a DC hub, including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and a lack of common system-level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products, as well as novel, in-house designed solutions, to evaluate different use cases at rated power and voltage levels. The developed proof-of-concept charging platform and open-source SEMS allow the development and testing of various controllers and chargers from different vendors. The DC hub platform integrated EVs, an ESS, a PV system, and building load to demonstrate the flexibility of the platform. The open-source SEMS controlled the devices within the hub using a rule-based implementation, realizing available standards.

ADVANCED PROPULSION SYSTEMS↗

American-Made Challenges Round 2 Voucher: Orison Enables Solar

This report documents the technical assistance provided to Orison as part of the American-Made Challenges Round 2 Voucher: Orison Enables Solar project. A testbed was developed and used to demonstrate, using modeling and simulation, the capability of controlled behind-the-meter energy storage to (1) reduce net load variability caused by appliances and distributed generation and (2) enable customers to respond to the time-of-use pricing. We demonstrate that load leveling can shave peak loads or limit solar photovoltaic export and that load shifting enables customers to reduce load during “peak” pricing intervals. In the scenarios that we simulated, load leveling was effective up to the charging and discharging limits of the storage systems and the effectiveness of load shifting was a function of the energy capacity of the storage systems. This report describes the co-simulation testbed and the scenarios simulated, including controller setup and simulation results. Considerations for a multi-objective controller are also discussed.

14 SOLAR ENERGY↗

Retracted Article: Distributed energy management for networked microgrids in a three-phase unbalanced distribution network

Owing to increased penetration of three-phase and single-phase microgrids, distributed energy resources (DERs), and responsive loads, the maintenance of a three-phase balance by distribution networks is a significant challenge. Existing literature on distributed energy management for networked microgrids generally neglects the distribution network or employs a simplified phase balanced distribution network; thus, these evaluations are not applicable. Further, the underlying mutual coupling between the different phases of distribution feeders results in a more challenging situation. Here, to solve this issue, this study sought to propose distributed energy management based on a three-phase unbalanced distribution network. Various three-phase or single-phase microgrids, utility-owned DERs, and responsive loads were coordinated through iteratively adjusted price signals. Based on the price signals received, the microgrid controllers (MCs) and distribution management system (DMS) updated the schedules of the DERs and responsive loads under their jurisdiction separately. The price signals were then updated according to the generation-load mismatch at each node and distributed to the corresponding MCs and DMS for the next iteration. The iteration continued until a sufficiently small generation-load mismatch was achieved at all nodes, that is, a balanced generation and load at all nodes under the agreed price signals. Considering a three-phase unbalanced distribution network, the price signals were determined per phase per node. Overall, the proposed distributed energy management coordinates microgrids, utility-owned DERs, responsive loads with guaranteed network constraints, and preserves the privacy of microgrid customers. This distributed energy management method was further demonstrated through various case studies on a three-phase networked microgrid test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Function-as-a-Service (FaaS) frameworks for the Accelerator Control System

As particle accelerator control systems evolve in complexity and scale, the need for responsive, scalable, and cost-effective computational infrastructure becomes increasingly critical. Function-as-a-Service (FaaS) offers an alternative to traditional monolithic architecture by enabling event-driven execution, automatic scaling, and fine-grained resource utilization. This paper explores the applicability and performance of FaaS frameworks in the context of a modern particle accelerator control system, with the objective of evaluating their suitability for short lived and triggered workloads. In this paper, we evaluate prominent open-source FaaS platforms in executing functional logic, triggers, and diagnostics routines. Evaluation metrics consist of cold-start latency, scalability, performance, integration with other open-source tools like Kafka. Experimental workloads were designed to simulate real-world control tasks when implemented as stateless FaaS functions. These workloads were benchmarked under various invocation loads and network conditions. Self-hosted FaaS platforms, when deployed within accelerator networks, offer greater control over execution environment, better integration with legacy systems, and support for real-time guarantees when paired with message queues. Based on lessons learned and evaluation metrics, this paper describes reliability of the FaaS framework for the Accelerator Control Systems (ACS).

Jaikar, A. [Fermilab] (ORCID:0000000332046217)↗

Safe Reinforcement Learning for Emergency Load Shedding of Power Systems

The paradigm shift in the electric power grid necessitates a revisit of existing control methods to ensure the grid’s security and resilience. In particular, the increased uncertainties and rapidly changing operational conditions in power systems have revealed outstanding issues in terms of either speed, adaptiveness, or scalability of the existing control methods for power systems. On the other hand, the availability of massive real-time data can provide a clearer picture of what is happening in the grid. Recently, deep reinforcement learning (RL) has been regarded and adopted as a promising approach leveraging massive data for fast and adaptive grid control. However, like most existing machine learning (ML)- based control techniques, RL control usually cannot guarantee the safety of the power systems. In this paper, we introduce a novel method for safe RL-based load shedding of power systems that can enhance the safe voltage recovery of the electric power grid after experiencing faults. Numerical simulation on the IEEE 39-bus testcase is performed to demonstrate the effectiveness of the proposed safe RL emergency control, as well as its adaptive capability to faults not seen in the training.

reinforcement learning, emergency control, power g↗

Slashing Platinum Group Metals (PGM) in Catalytic Converters: An Atoms-to-Autos Approach

Platinum group metals (PGMs) are used in three-way catalysts (TWCs) for stoichiometric gasoline engine vehicles to simultaneously convert carbon monoxide, hydrocarbons, and nitrogen oxides into nitrogen, carbon dioxide and water. For US light duty gasoline vehicles, about 3-8 grams of PGMs are used in each catalytic converter system and the PGM loading is expected to increase for future vehicles, driven by increasingly stringent emissions standards, potentially lower engine exhaust temperatures, and higher emission control system durability requirements. The technical necessity for the current high PGM loadings is largely driven by: 1) poor atomic efficiency (or metal dispersion) of PGMs on catalyst supports with the current synthesis approaches, and 2) severe deactivation of unstable PGM nanoparticles in high temperature engine exhaust. Therefore, the project team will develop catalyst technologies that not only maximize the PGM atom efficiency and intrinsic activity in the fresh state, but also maintain the benefits during aging with extended exposure in engine exhaust.

36 MATERIALS SCIENCE↗

Summary of the IAEA technical meeting on plasma disruptions and their mitigation

Here we summarize the contributions presented at the IAEA technical meeting on plasma disruptions and their mitigation, held virtually, 20–23 July 2020. The meeting brought together more than 120 experts from nuclear fusion research sites worldwide to discuss experimental, theoretical and modelling work in the field of plasma disruptions with special emphasis on developing a solid basis for possible disruption mitigation strategies in ITER and next generation fusion devices. The main topics of the meeting were: (i) disruption consequences, including electromagnetic loads, heat loads, and runaway electrons; (ii) disruption prediction and avoidance, including machine learning and physics-based approaches, and control aspects; and (iii) disruption mitigation, including shattered pellet injection, alternative techniques and general aspects of disruption mitigation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Investigation into the Effects of Swirl on the Performance and Emissions of an Opposed-Piston Two-Stroke Engine using Large Eddy Simulations

Opposed-piston two-stroke (OP-2S) engines have the potential to achieve higher thermal efficiency than a conventional four-stroke diesel engine. However, the uniflow scavenging process is difficult to control over a wider range of speed and loads due to its sensitivity to pressure dynamics, port timings, and port design. Specifically, the angle of the intake ports can be used to generate swirl which has implications for open and closed cycle effects. This study proposes an analysis of the effects of port angle on the in-cylinder flow distribution and combustion performance of an OP-2S using computational fluid dynamics engine. Large Eddy Simulation (LES) was used to model turbulence given its ability to predict in-cylinder mixing and cyclic variability. A three-cylinder model was validated to experimental data collected by Achates Power and the grid was verified using an LES quality approach from the literature. The model was used to simulate port angles from 12 to 29 degrees at constant pressure and temperature boundary conditions. Results indicated that the higher bulk swirl ratio generated by larger port angles tends to trap more internal residuals. This effect on the scavenging performance, combined with the larger trapped swirl ratio, also has a significant impact on the combustion performance in a two-stroke engine. It was concluded that there exists a tradeoff of efficiency and emissions that must be considered when increasing the port angle in a uniflow two-stroke engine. 1. Introduction Two-stroke engines were developed in the 1800s and are commonly used in practice today for lightweight power applications such as motorcycles or handheld power tools, as well as large-bore low speed engines for stationary power and marine applications. Two-stroke engines provide the distinct advantage of higher torque/power output but present challenges due to its coupled intake and exhaust process. Four-stroke engines have the benefit of using two full piston strokes to induct intake charge and to expel exhaust gases. Controlling the trapped charge composition in a twostroke engine via a scavenging process is crucial for reliable and efficient engine operation.

33 ADVANCED PROPULSION SYSTEMS↗

Characterization of a Human Platelet Lysate-Loaded Keratin Hydrogel for Wound Healing Applications In Vitro

One of the promising approaches to facilitate healing and regenerative capacity includes the application of growth-factor-loaded biomaterials. Human platelet lysate (hPL) derived from platelet-rich plasma through a freeze-thaw process has been used as a growth factor rich therapeutic in many regenerative applications. To provide sustained local delivery of the hPL-derived growth factors such as epidermal growth factor (EGF), the hPL can be loaded into biomaterials that do not degrade rapidly in vivo. Keratin (KSO), a strong filamentous protein found in human hair, when formulated as a hydrogel, is shown to sustain the release of drugs and promote wound healing. In the current study, we created a KSO biomaterial that spontaneously forms a hydrogel when rehydrated with hPL that is capable of controlled and sustained release of pro-regenerative molecules. Our study demonstrates that the release of hPL is controlled by changing the KSO hydrogel and hPL-loading concentrations, with hPL loading concentrations having a greater effect in changing release profiles. In addition, the 15% KSO concentration proved to form a stable hydrogel, and supported cell proliferation over 3 days without cytotoxic effects in vitro. The hPL-loaded keratin hydrogels show promise in potential applications for wound healing with the sustained release of pro-regenerative growth factors with easy tailoring of hydrogel properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic modelling and control strategy of a temperature-driven metal hydride cooling system for buildings

A temperature-driven coupled metal hydride (MH) based thermal energy storage (TES) system can allow to shave and shift the peak energy demand in buildings. The high energy density and long-term (seasonal) energy storage capability are its major advantages over other energy storage methods. The dynamic nature of the MH operation, however, requires controlled hydrogen transfer between the coupled MHs at a rate needed to meet the building's transient load. While temperature-driven MH systems are studied in the literature, their application in buildings and control are scarcely reported. Here, this paper presents a control-based dynamic modeling of the temperature-driven coupled MH-TES system for building cooling applications. The dynamic model is developed in MATLAB(R) Simulink environment, considering the thermodynamic and kinetic behaviors of the MH systems. Based on a preliminary analysis of a property database of over 337 hydrides, we select around 1600 MH pairs suitable for building cooling applications. Each of these MH pairs is studied for their performance using the dynamic model, and among all, Zr 0.76 Ti 0.24 Ni 1.16 Mn 0.63 V 0.14 Fe 0.18 -Ti 0.85 Zr 0.15 Cr 1.2 Mn 0.8 MH pair showed fast dynamics along with high coefficient of performance (COP) of 0.71. A parametric investigation is performed on this MH pair to understand the effect of operating temperatures. Finally, three proportional-integral (PI) feedback controllers are investigated to regulate the temperature, pressure and mass exchange between the coupled MH pairs. The developed PI controller is sufficiently capable of rejecting the signal noise from the hydrogen flow and internal heat exchange processes with root mean square error of 5.78 W between reference and actual cooling load.

08 HYDROGEN↗

Aero‐servo‐elastic co‐optimization of large wind turbine blades with distributed aerodynamic control devices

Abstract This work introduces automated wind turbine optimization techniques based on full aero‐servo‐elastic models and investigates the potential of trailing edge flaps to reduce the levelized cost of energy (LCOE) of wind turbines. The Wind Energy with Integrated Servo‐control (WEIS) framework is improved to conduct the presented research. Novel methods for the generic implementation and tuning of trailing edge flap devices and their controller are also introduced. Primary flap and controller parameters are optimized to demonstrate potential maximum blade tip deflection reductions of 21 % . Concurrent design optimization (i.e., co‐design) of a novel segmented wind turbine blade with trailing edge flaps and its controller is then conducted to demonstrate blade cost savings of 5 % . Additionally, rotor diameter co‐design optimization is demonstrated to reduce the LCOE by 1.3 % without significant load increases to the tower. These results demonstrate the efficacy of control co‐design optimization using trailing edge flaps, and the entirety of this work provides a foundation for numerous control co‐design‐oriented studies for distributed aerodynamic control devices.

17 WIND ENERGY↗

Demand Driven Energy Management for PIPO Auxiliary Power Supply Architecture

In this paper, a demand driven energy management (DDEM) technique is implemented on modular parallel input parallel output DC/DC auxiliary power supply (APS) structure. In this method, modules are brought in/out of the operation making them operate under high loading conditions, avoiding low efficiency under light load. Such a method finds its application in power conservative systems with variable load. Implementation of DDEM and the energy saved is shown using APS comprised of two 15W commercially off-the-shelf DC-DC modules, with 100–1000 VDC input and 24 V output voltage. Along with the DDEM, the lifetime of the power stage devices is controlled minimizing their junction temperature swing through control of cooling system. This control method uses digital twin as interface to virtualize the power devices loading operation/ health condition. Accordingly, no extra sensor or closed loop control required to measure the junction temperature of the devices or feedback the losses to the cooling flow.

Azadeh, Yalda↗

Uptake and speciation of trace metal inputs to Wetland Soils from Illinois and South Carolina and Stream Sediments from Tennessee

Metals occur in all ecosystems, although their concentrations vary depending on their natural geologic conditions and surrounding human activities. In addition to metals intrinsically present from the geology of a particular system, metals can enter environmental systems from a wide variety of natural and anthropogenic sources, such as sediment re-suspension, mining operations, industrial processes, agricultural activities, and atmospheric deposition. While metals can be toxic at high concentrations, some metals serve as essential micronutrients for biogeochemical processes. Metal transport and availability in engineered and natural water systems depend on processes of adsorption/desorption, oxidation/reduction, dissolution/precipitation, and ligand complexation. Insights into the speciation of metals and their bioavailability will also help advance understanding of the roles of metals in the biogeochemical cycling of nutrients. We conducted batch experiments under anoxic conditions on soils and sediments collected from three different natural aquatic systems to understand their response to influxes of dissolved Cu, Ni and Zn. While soils and sediments from all sites could strongly bind added trace metals, there were substantial differences in trace metal uptake trends between different sites, especially for Cu. There was no distinct correlation between trace metal uptake and the total organic matter, iron, and sulfur content present in the samples. X-ray absorption spectroscopy indicated that the speciation of the freshly added metals taken up by the solids differs substantially from the speciation of the metals originally present in unamended samples. Cu sulfides dominated speciation at low loadings (1 µmol/g), whereas complexation to thiol groups and formation of metallic Cu governed speciation at high loadings (10 µmol/g). For Ni and Zn, adsorption to mineral surfaces and organic matter governed their speciation in materials from most sites. This study suggests that the background speciation of metals in natural aquatic systems is a poor predictor of the speciation and lability of metals introduced to terrestrial aquatic systems from anthropogenic or natural processes. Our findings imply that geochemical processes controlling trace metal speciation may vary considerably with metal loading in different natural systems. Data are provided for marsh wetland soils at Argonne National Laboratory (Marsh 1 and Marsh 2), riparian wetland soils (Riparian 1 and Riparian 2) in the Tims Branch watershed at Savannah River National Laboratory, and stream bed sediments (Stream 1 and Stream 2) from East Fork Poplar Creek near Oak Ridge National Laboratory. Data package includes the results of trace metal uptake experiments conducted on the selected sites for determining their capacity to immobilize metals under different loadings. XANES spectra for Cu, Ni, ad Zn at different loadings are included in the package. The abundance of different trace metal species obtained using linear combination fitting in ATHENA are also included in the data.

54 ENVIRONMENTAL SCIENCES↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗