Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Conveying the 3D Shape of Transparent Surfaces Via Texture

Transparency can be a useful device for depicting multiple overlapping surfaces in a single image. The challenge is to render the transparent surfaces in such a way that their three-dimensional shape can be readily understood and their depth distance from underlying structures clearly perceived. This paper describes our investigations into the use of sparsely-distributed discrete, opaque texture as an 'artistic device' for more explicitly indicating the relative depth of a transparent surface and for communicating the essential features of its 3D shape in an intuitively meaningful and minimally occluding way. The driving application for this work is the visualization of layered surfaces in radiation therapy treatment planning data, and the technique is illustrated on transparent isointensity surfaces of radiation dose. We describe the perceptual motivation and artistic inspiration for defining a stroke texture that is locally oriented in the direction of greatest normal curvature (and in which individual strokes are of a length proportional to the magnitude of the curvature in the direction they indicate), and discuss several alternative methods for applying this texture to isointensity surfaces defined in a volume. We propose an experimental paradigm for objectively measuring observers' ability to judge the shape and depth of a layered transparent surface, in the course of a task relevant to the needs of radiotherapy treatment planning, and use this paradigm to evaluate the practical effectiveness of our approach through a controlled observer experiment based on images generated from actual clinical data.

Interrante, Victoria↗

Pulmonary venous flow determinants of left atrial pressure under different loading conditions in a chronic animal model with mitral regurgitation

BACKGROUND: The aim of our study was to quantitatively compare the changes and correlations between pulmonary venous flow variables and mean left atrial pressure (mLAP) under different loading conditions in animals with chronic mitral regurgitation (MR) and without MR. METHODS: A total of 85 hemodynamic conditions were studied in 22 sheep, 12 without MR as control (NO-MR group) and 10 with MR (MR group). We obtained pulmonary venous flow systolic velocity (Sv) and diastolic velocity (Dv), Sv and Dv time integrals, their ratios (Sv/Dv and Sv/Dv time integral), mLAP, left ventricular end-diastolic pressure, and MR stroke volume. We also measured left atrial a, x, v, and y pressures and calculated the difference between v and y pressures. RESULTS: Average MR stroke volume was 10.6 +/- 4.3 mL/beat. There were good correlations between Sv (r = -0.64 and r = -0.59, P <.01), Sv/Dv (r = -0.62 and r = -0.74, P <.01), and mLAP in the MR and NO-MR groups, respectively. Correlations were also observed between Dv time integral (r = 0.61 and r = 0.57, P <.01) and left ventricular end-diastolic pressure in the MR and NO-MR groups. In velocity variables, Sv (r = -0.79, P <.001) was the best predictor of mLAP in both groups. The sensitivity and specificity of Sv = 0 in predicting mLAP 15 mm Hg or greater were 86% and 85%, respectively. CONCLUSION: Pulmonary venous flow variables correlated well with mLAP under altered loading conditions in the MR and NO-MR groups. They may be applied clinically as substitutes for invasively acquired indexes of mLAP to assess left atrial and left ventricular functional status.

Pulmonary Veins/physiopathology↗

A Phase 2 Trial of Stereotactic Radiosurgery Boost After Surgical Resection for Brain Metastases

Purpose: To evaluate local control after surgical resection and postoperative stereotactic radiosurgery (SRS) for brain metastases. Methods and Materials: A total of 49 patients (50 lesions) were enrolled and available for analysis. Eligibility criteria included histologically confirmed malignancy with 1 or 2 intraparenchymal brain metastases, age ≥18 years, and Karnofsky performance status (KPS) ≥70. A Cox proportional hazard regression model was used to test for significant associations between clinical factors and overall survival (OS). Competing risks regression models, as well as cumulative incidence functions, were fit using the method of Fine and Gray to assess the association between clinical factors and both local failure (LF; recurrence within surgical cavity or SRS target), and regional failure (RF; intracranial metastasis outside of treated volume). Results: The median follow-up was 12.0 months (range, 1.0-94.1 months). After surgical resection, 39 patients with 40 lesions were treated a median of 31 days (range, 7-56 days) later with SRS to the surgical bed to a median dose of 1800 cGy (range, 1500-2200 cGy). Of the 50 lesions, 15 (30%) demonstrated LF after surgery. The cumulative LF and RF rates were 22% and 44% at 12 months. Patients who went on to receive SRS had a significantly lower incidence of LF (P=.008). Other factors associated with improved local control include non-small cell lung cancer histology (P=.048), tumor diameter <3 cm (P=.010), and deep parenchymal tumors (P=.036). Large tumors (≥3 cm) with superficial dural/pial involvement showed the highest risk for LF (53.3% at 12 months). Large superficial lesions treated with SRS had a 54.5% LF. Infratentorial lesions were associated with a higher risk of developing RF compared to supratentorial lesions (P<.001). Conclusions: Postoperative SRS is associated with high rates of local control, especially for deep brain metastases <3 cm. Tumors ≥3 cm with superficial dural/pial involvement demonstrate the highest risk of LF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Facile and template-free method toward chemical synthesis of polyaniline film/nanotube structures

Here, a facile and template-free method is reported to synthesize a new thin film structure: polyaniline (PANI) film/nanotubes (F/N) structure. The PANI F/N is a 100-nm thick PANI film embedded with PANI nanotubes. This well-controlled method requires no surfactant or organic acid as well as relatively low concentration of reagents. Synthesis condition studies reveal that aniline oligomers with certain structures are responsible for guiding the growth of the nanotubes. Electrical characterization also indicates that the PANI F/N possesses similar field-effect transistor characteristics to bare PANI film. With its 20% increased surface-area-to-volume (S/V) ratio contributed by surface embedded nanotubes and the excellent p-type semiconducting characteristic, PANI F/N shows clear superiority compared with bare PANI film. Such advantages guarantee the PANI F/N a promising future toward the development of ultra-high sensitivity and low-cost biosensors.

36 MATERIALS SCIENCE↗

Migration of finite sized particles in a laminar square channel flow from low to high Reynolds numbers

The migration of neutrally buoyant finite sized particles in a Newtonian square channel flow is investigated in the limit of very low solid volumetric concentration, within a wide range of channel Reynolds numbers Re = [0.07-120]. In situ microscope measurements of particle distributions, taken far from the channel inlet (at a distance several thousand times the channel height), revealed that particles are preferentially located near the channel walls at Re > 10 and near the channel center at Re < 1. Whereas the cross-streamline particle motion is governed by inertia-induced lift forces at high inertia, it seems to be controlled by shear-induced particle interactions at low (but finite) Reynolds numbers, despite the low solid volume fraction (<1%). The transition between both regimes is observed in the range Re = [1-10]. In order to exclude the effect of multi-body interactions, the trajectories of single freely moving particles are calculated thanks to numerical simulations based on the force coupling method. With the deployed numerical tool, the complete particle trajectories are accessible within a reasonable computational time only in the inertial regime (Re > 10). In this regime, we show that (i) the particle undergoes cross-streamline migration followed by a cross-lateral migration (parallel to the wall) in agreement with previous observations, and (ii) the stable equilibrium positions are located at the midline of the channel faces while the diagonal equilibrium positions are unstable. At low flow inertia, the first instants of the numerical simulations (carried at Re = O(1)) reveal that the cross-streamline migration of a single particle is oriented towards the channel wall, suggesting that the particle preferential positions around the channel center, observed in the experiments, are rather due to multi-body interactions.

42 ENGINEERING↗

Localization accuracy from automatic and semi-automatic rigid registration of locally-advanced lung cancer targets during image-guided radiation therapy

Purpose: To evaluate localization accuracy resulting from rigid registration of locally-advanced lung cancer targets using fully automatic and semi-automatic protocols for image-guided radiation therapy. Methods: Seventeen lung cancer patients, fourteen also presenting with involved lymph nodes, received computed tomography (CT) scans once per week throughout treatment under active breathing control. A physician contoured both lung and lymph node targets for all weekly scans. Various automatic and semi-automatic rigid registration techniques were then performed for both individual and simultaneous alignments of the primary gross tumor volume (GTV{sub P}) and involved lymph nodes (GTV{sub LN}) to simulate the localization process in image-guided radiation therapy. Techniques included ''standard'' (direct registration of weekly images to a planning CT), ''seeded'' (manual prealignment of targets to guide standard registration), ''transitive-based'' (alignment of pretreatment and planning CTs through one or more intermediate images), and ''rereferenced'' (designation of a new reference image for registration). Localization error (LE) was assessed as the residual centroid and border distances between targets from planning and weekly CTs after registration. Results: Initial bony alignment resulted in centroid LE of 7.3 {+-} 5.4 mm and 5.4 {+-} 3.4 mm for the GTV{sub P} and GTV{sub LN}, respectively. Compared to bony alignment, transitive-based and seeded registrations significantly reduced GTV{sub P} centroid LE to 4.7 {+-} 3.7 mm (p = 0.011) and 4.3 {+-} 2.5 mm (p < 1 x 10{sup -3}), respectively, but the smallest GTV{sub P} LE of 2.4 {+-} 2.1 mm was provided by rereferenced registration (p < 1 x 10{sup -6}). Standard registration significantly reduced GTV{sub LN} centroid LE to 3.2 {+-} 2.5 mm (p < 1 x 10{sup -3}) compared to bony alignment, with little additional gain offered by the other registration techniques. For simultaneous target alignment, centroid LE as low as 3.9 {+-} 2.7 mm and 3.8 {+-} 2.3 mm were achieved for the GTV{sub P} and GTV{sub LN}, respectively, using rereferenced registration. Conclusions: Target shape, volume, and configuration changes during radiation therapy limited the accuracy of standard rigid registration for image-guided localization in locally-advanced lung cancer. Significant error reductions were possible using other rigid registration techniques, with LE approaching the lower limit imposed by interfraction target variability throughout treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Micro Blowing Simulations Using a Coupled Finite-Volume Lattice-Boltzman n L ES Approach

Three dimensional large-eddy simulations (LES) of single and multiple jet-in-cross-flow (JICF) are conducted using the 19-bit Lattice Boltzmann Equation (LBE) method coupled with a conventional finite-volume (FV) scheme. In this coupled LBE-FV approach, the LBE-LES is employed to simulate the flow inside the jet nozzles while the FV-LES is used to simulate the crossflow. The key application area is the use of this technique is to study the micro blowing technique (MBT) for drag control similar to the recent experiments at NASA/GRC. It is necessary to resolve the flow inside the micro-blowing and suction holes with high resolution without being restricted by the FV time-step restriction. The coupled LBE-FV-LES approach achieves this objectives in a computationally efficient manner. A single jet in crossflow case is used for validation purpose and the results are compared with experimental data and full LBE-LES simulation. Good agreement with data is obtained. Subsequently, MBT over a flat plate with porosity of 25% is simulated using 9 jets in a compressible cross flow at a Mach number of 0.4. It is shown that MBT suppresses the near-wall vortices and reduces the skin friction by up to 50 percent. This is in good agreement with experimental data.

Menon, S.↗

Monte Carlo simulations of lattice models for single polymer systems

Single linear polymer chains in dilute solutions under good solvent conditions are studied by Monte Carlo simulations with the pruned-enriched Rosenbluth method up to the chain length N∼O(10{sup 4}). Based on the standard simple cubic lattice model (SCLM) with fixed bond length and the bond fluctuation model (BFM) with bond lengths in a range between 2 and √(10), we investigate the conformations of polymer chains described by self-avoiding walks on the simple cubic lattice, and by random walks and non-reversible random walks in the absence of excluded volume interactions. In addition to flexible chains, we also extend our study to semiflexible chains for different stiffness controlled by a bending potential. The persistence lengths of chains extracted from the orientational correlations are estimated for all cases. We show that chains based on the BFM are more flexible than those based on the SCLM for a fixed bending energy. The microscopic differences between these two lattice models are discussed and the theoretical predictions of scaling laws given in the literature are checked and verified. Our simulations clarify that a different mapping ratio between the coarse-grained models and the atomistically realistic description of polymers is required in a coarse-graining approach due to the different crossovers to the asymptotic behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spine Radiosurgery: A Dosimetric Analysis in 124 Patients Who Received 18 Gy

Purpose: To define the safely tolerated doses to organs at risk (OARs) adjacent to the target volume (TV) of spine radiosurgery (SRS) with 18-Gy in a single fraction. Methods and Materials: A total of 124 patient cases with 165 spine metastases were reviewed. An 18-Gy single-fraction regimen was prescribed to the 90% isodose line encompassing the TV. A constraint of 10 Gy to 10% of the spinal cord outlined 6 mm above and below the TV was used. Dosimetric data to OARs were analyzed. Results: A total of 124 patients (100%) were followed-up, and median follow-up time was 7 months (1-50 months). Symptoms and local control were achieved in 114 patients (92%). Acute Radiation Therapy Oncology Group (RTOG) grade 1 oral mucositis occurred in 11 of 11 (100%) patients at risk for oropharyngeal toxicity after cervical spine treatment. There were no RTOG grade 2-4 acute or late complications. Median TV was 43.2 cc (5.3-175.4 cc) and 90% of the TV received median dose of 19 Gy (17-19.8 Gy). Median (range) of spinal cord maximum dose (Dmax), dose to spinal cord 0.35 cc (Dsc0.35), and cord volume receiving 10 Gy (Vsc10) were 13.8 Gy (5.4-21 Gy), 8.9 Gy (2.6-11.4 Gy) and 0.33 cc (0-1.6 cc), respectively. Other OARs were evaluated when in proximity to the TV. Esophagus (n=58), trachea (n=28), oropharynx (n=11), and kidneys (n=34) received median (range) V10 and V15 of 3.1 cc (0-5.8 cc) and 1.2 cc (0-2.9 cc), 2.8 cc (0-4.9 cc), and 0.8 cc (0-2.1 cc), 3.4 cc (0-6.2 cc) and 1.6 cc (0-3.2 cc), 0.3 cc (0-0.8 cc) and 0.08 cc (0-0.1 cc), respectively. Conclusions: Cord Dmax of 14 Gy and D0.35 of 10 Gy are safe dose constraints for 18-Gy single-fraction SRS. Esophagus V10 of 3 cc and V15 of 1 cc, trachea V10 of 3 cc, and V15 of 1 cc, oropharynx V10 of 3.5 cc and V15 of 1.5 cc, kidney V10 of 0.3 cc, and V15 of 0.1 cc are planning guidelines when these OARs are in proximity to the TV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-CD-304-06: Using FFF Beams Improves Tumor Control in Radiotherapy of Lung Cancers

Purpose: Electron disequilibrium at the lung-tumor interface results in an under-dosage of tumor regions close to its surface. This under-dosage is known to be significant and can compromise tumor control. Previous studies have shown that in FFF beams, disequilibrium effects are less pronounced, which is manifested in an increased skin dose. In this study we investigate the improvement in tumor dose coverage that can be achieved with FFF beams. The significance of this improvement is evaluated by comparing tumor control probabilities of FFF beams and conventional flattened beams. Methods: The dosimetric coverage was investigated in a virtual phantom representing the chest wall, lung tissue and the tumor. A range of tumor sizes was investigated, and two tumor locations – central and adjacent to the chest wall. Calculations were performed with BEAMnrc Monte Carlo code. Parallel-opposed and multiple coplanar 6-MV beams were simulated. The tumor control probabilities were calculated using the logistic model with parameters derived from clinical data for non-small lung cancer patients. Results: FFF beams were not entirely immune to disequilibrium effects. They nevertheless consistently delivered more uniform dose distribution throughout the volume of the tumor, and eliminated up to ∼15% of under-dosage in the most affected by disequilibrium 1-mm thick surface region of the tumor. A voxel-by-voxel comparison of tumor control probabilities between FFF and conventional flattened beams showed an advantage of FFF beams that, depending on the set up, was from a few to ∼9 percent. Conclusion: A modest improvement in tumor control probability on the order of a few percent can be achieved by replacing conventional flattened beams with FFF beams. However, given the large number of lung cancer patients undergoing radiotherapy, these few percent can potentially prevent local tumor recurrence for a significant number of patients.

60 APPLIED LIFE SCIENCES↗

Adaptive nonlocal means filtering based on local noise level for CT denoising

Purpose: To develop and evaluate an image-domain noise reduction method based on a modified nonlocal means (NLM) algorithm that is adaptive to local noise level of CT images and to implement this method in a time frame consistent with clinical workflow. Methods: A computationally efficient technique for local noise estimation directly from CT images was developed. A forward projection, based on a 2D fan-beam approximation, was used to generate the projection data, with a noise model incorporating the effects of the bowtie filter and automatic exposure control. The noise propagation from projection data to images was analytically derived. The analytical noise map was validated using repeated scans of a phantom. A 3D NLM denoising algorithm was modified to adapt its denoising strength locally based on this noise map. The performance of this adaptive NLM filter was evaluated in phantom studies in terms of in-plane and cross-plane high-contrast spatial resolution, noise power spectrum (NPS), subjective low-contrast spatial resolution using the American College of Radiology (ACR) accreditation phantom, and objective low-contrast spatial resolution using a channelized Hotelling model observer (CHO). Graphical processing units (GPU) implementation of this noise map calculation and the adaptive NLM filtering were developed to meet demands of clinical workflow. Adaptive NLM was piloted on lower dose scans in clinical practice. Results: The local noise level estimation matches the noise distribution determined from multiple repetitive scans of a phantom, demonstrated by small variations in the ratio map between the analytical noise map and the one calculated from repeated scans. The phantom studies demonstrated that the adaptive NLM filter can reduce noise substantially without degrading the high-contrast spatial resolution, as illustrated by modulation transfer function and slice sensitivity profile results. The NPS results show that adaptive NLM denoising preserves the shape and peak frequency of the noise power spectrum better than commercial smoothing kernels, and indicate that the spatial resolution at low contrast levels is not significantly degraded. Both the subjective evaluation using the ACR phantom and the objective evaluation on a low-contrast detection task using a CHO model observer demonstrate an improvement on low-contrast performance. The GPU implementation can process and transfer 300 slice images within 5 min. On patient data, the adaptive NLM algorithm provides more effective denoising of CT data throughout a volume than standard NLM, and may allow significant lowering of radiation dose. After a two week pilot study of lower dose CT urography and CT enterography exams, both GI and GU radiology groups elected to proceed with permanent implementation of adaptive NLM in their GI and GU CT practices. Conclusions: This work describes and validates a computationally efficient technique for noise map estimation directly from CT images, and an adaptive NLM filtering based on this noise map, on phantom and patient data. Both the noise map calculation and the adaptive NLM filtering can be performed in times that allow integration with clinical workflow. The adaptive NLM algorithm provides effective denoising of CT data throughout a volume, and may allow significant lowering of radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced ETC/LSS computerized analytical models, CO2 concentration. Volume 1: Summary document

Computer simulations have been prepared for the concepts of C02 concentration which have the potential for maintaining a C02 partial pressure of 3.0 mmHg, or less, in a spacecraft environment. The simulations were performed using the G-189A Generalized Environmental Control computer program. In preparing the simulations, new subroutines to model the principal functional components for each concept were prepared and integrated into the existing program. Sample problems were run to demonstrate the methods of simulation and performance characteristics of the individual concepts. Comparison runs for each concept can be made for parametric values of cabin pressure, crew size, cabin air dry and wet bulb temperatures, and mission duration.

Taylor, B. N.↗

Design studies of Laminar Flow Control (LFC) wing concepts using superplastics forming and diffusion bonding (SPF/DB)

Alternate concepts and design approaches were developed for suction panels and techniques were defined for integrating these panel designs into a complete LFC 200R wing. The design concepts and approaches were analyzed to assure that they would meet the strength, stability, and internal volume requirements. Cost and weight comparisions of the concepts were also made. Problems of integrating the concepts into a complete aircraft system were addressed. Methods for making splices both chordwise and spanwise, fuel light joints, and internal duct installations were developed. Manufacturing problems such as slot aligment, tapered slot spacing, production methods, and repair techniques were addressed. An assessment of the program was used to developed recommendations for additional research in the development of SPF/DB for LFC structure.

Wilson, V. E.↗

Single-Fraction Stereotactic Body Radiation Therapy and Sequential Gemcitabine for the Treatment of Locally Advanced Pancreatic Cancer

Purpose: This Phase II trial evaluated the toxicity, local control, and overall survival in patients treated with sequential gemcitabine and linear accelerator-based single-fraction stereotactic body radiotherapy (SBRT). Methods and Materials: Twenty patients with locally advanced, nonmetastatic pancreatic adenocarcinoma were enrolled on this prospective single-institution, institutional review board-approved study. Gemcitabine was administered on Days 1, 8, and 15, and SBRT on Day 29. Gemcitabine was restarted on Day 43 and continued for 3-5 cycles. SBRT of 25 Gy in a single fraction was delivered to the internal target volume with a 2- 3-mm margin using a nine-field intensity-modulated radiotherapy technique. Respiratory gating was used to account for breathing motion. Follow-up evaluations occurred at 4-6 weeks, 10-12 weeks, and every 3 months after SBRT. Results: All patients completed SBRT and a median of five cycles of chemotherapy. Follow-up for the 2 remaining alive patients was 25.1 and 36.4 months. No acute Grade 3 or greater nonhematologic toxicity was observed. Late Grade 3 or greater toxicities occurred in 1 patient (5%) and consisted of a duodenal perforation (G4). Three patients (15%) developed ulcers (G2) that were medically managed. Overall, median survival was 11.8 months, with 1-year survival of 50% and 2-year survival of 20%. Using serial computed tomography, the freedom from local progression was 94% at 1 year. Conclusion: Linear accelerator-delivered SBRT with sequential gemcitabine resulted in excellent local control of locally advanced pancreatic cancer. Future studies will address strategies for reducing long-term duodenal toxicity associated with SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Approach to Postmastectomy Radiation Therapy Using Scanned Proton Beams

Purpose: Postmastectomy radiation therapy (PMRT), currently offered at Massachusetts General Hospital, uses proton pencil beam scanning (PBS) with intensity modulation, achieving complete target coverage of the chest wall and all nodal regions and reduced dose to the cardiac structures. This work presents the current methodology for such treatment and the ongoing effort for its improvements. Methods and Materials: A single PBS field is optimized to ensure appropriate target coverage and heart/lung sparing, using an in–house-developed proton planning system with the capability of multicriteria optimization. The dose to the chest wall skin is controlled as a separate objective in the optimization. Surface imaging is used for setup because it is a suitable surrogate for superficial target volumes. In order to minimize the effect of beam range uncertainties, the relative proton stopping power ratio of the material in breast implants was determined through separate measurements. Phantom measurements were also made to validate the accuracy of skin dose calculation in the treatment planning system. Additionally, the treatment planning robustness was evaluated relative to setup perturbations and patient breathing motion. Results: PBS PMRT planning resulted in appropriate target coverage and organ sparing, comparable to treatments by passive scattering (PS) beams but much improved in nodal coverage and cardiac sparing compared to conventional treatments by photon/electron beams. The overall treatment time was much shorter than PS and also shorter than conventional photon/electron treatment. The accuracy of the skin dose calculation by the planning system was within ±2%. The treatment was shown to be adequately robust relative to both setup uncertainties and patient breathing motion, resulting in clinically satisfying dose distributions. Conclusions: More than 25 PMRT patients have been successfully treated at Massachusetts General Hospital by using single-PBS fields. The methodology and robustness of both the setup and the treatment have been discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Flux Detection Probe to Quantify Dynamic Groundwater-Surface Water Exchange in the Hyporheic Zone

A new probe was designed to quantify groundwater-surface water exchange in the hyporheic zone under dynamic stage condition. Current methods focus on either vertical pore water velocity or Darcy flux measurements. Both parameters must be understood to evaluate residence time and mass flux of constituents. Furthermore, most instruments are not well suited for monitoring instantaneous velocity or flux under dynamic exchange conditions. For this reason, the flux detection probe (FDP) was designed that employs electrogeophysical measurements to estimate in situ sediment porosity, which can be used to convert pore water velocity to Darcy flux. Dynamic pore water velocity is obtained by monitoring fluid conductivity and temperature along the FDP probe. Pressure sensors deployed at the top and bottom of the probe provide the additional information necessary to estimate vertical permeability. This study focuses on the use of a geophysical method to estimate pore water velocity, porosity, and permeability within a controlled soil column where simulated river water displaces simulated groundwater. The difference between probe derived and theoretical pore water velocity using natural tracers such as electrical conductivity and temperature was -4.9 and 3.9% for downward flow and 1.1 and 12.8% for upward flow, respectively. The difference in porosity calculated from mass and volume packed in the soil column and probe measure porosity ranged between -3.2% and 1.5%. Also, the calculated hydraulic conductivity differed from probe derived values by -8.9%.

54 ENVIRONMENTAL SCIENCES↗

Carbon Dioxide Removal Troubleshooting aboard the International Space Station (ISS) during Space Shuttle (STS) Docked Operations

The International Space Station (ISS) represents a largely closed-system habitable volume which requires active control of atmospheric constituents, including removal of exhaled Carbon Dioxide (CO2). The ISS provides a unique opportunity to observe system requirements for (CO2) removal. CO2 removal is managed by the Carbon Dioxide Removal Assembly (CDRA) aboard the US segment of ISS and by Lithium Hydroxide (LiOH) aboard the Space Shuttle (STS). While the ISS and STS are docked, various methods are used to balance the CO2 levels between the two vehicles, including mechanical air handling and management of general crew locations. Over the course of ISS operation, several unexpected anomalies have occurred which have required troubleshooting, including possible compromised performance of the CDRA and LiOH systems, and possible imbalance in CO2 levels between the ISS and STS while docked. This paper will cover efforts to troubleshoot the CO2 removal systems aboard the ISS and docked STS.

Matty, Christopher M.↗

Reversible, on-demand generation of aqueous two-phase microdroplets

The present invention provides methods of on-demand, reversible generation of aqueous two-phase microdroplets core-shell microbeads, microparticle preparations comprising the core-shell microbeads, and drug delivery formulation comprising the microparticle preparations. Because these aqueous microdroplets have volumes comparable to those of cells, they provide an approach to mimicking the dynamic microcompartmentation of biomaterial that naturally occurs within the cytoplasm of cells. Hence, the present methods generate femtoliter aqueous two-phase droplets within a microfluidic oil channel using gated pressure pulses to generate individual, stationary two-phase microdroplets with a well-defined time zero for carrying out controlled and sequential phase transformations over time. Reversible phase transitions between single-phase, two-phase, and core-shell microbead states are obtained via evaporation-induced dehydration and water rehydration.

59 BASIC BIOLOGICAL SCIENCES↗