Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Apollo 16 far-ultraviolet imagery and spectra of the Large Magellanic Cloud

The Large Magellanic Cloud was observed by the far ultraviolet camera spectrograph from the lunar surface during the Apollo 16 mission 22 April 1972. Images were obtained with about 3 arc min resolution, in the 1,050 to 1,600 and 1,250 to 1,600 A wavelength ranges, of nearly the entire LMC. Spectra were also obtained in the 1,050 to 1,600 and 900 to 1,600 A ranges along a strip 1/4 deg wide (determined by the instrument's grid collimator) passing across the LMC. The images and spectra have been scanned with a PDS microdensitometer, and isodensity contour plots have been prepared using the Univac 1108 computer.

Page, T.↗

Instrumental technique in X-ray astronomy

A detailed review of the development of instruments for X-ray astronomy is given with major emphasis on nonfocusing high-sensitivity counter techniques used to detect cosmic photons in the energy range between 0.20 and 300 keV. The present status of X-ray astronomy is summarized together with significant results of the Uhuru observations, and photon interactions of importance for the detection of X-rays in space are noted. The three principal devices used in X-ray astronomy (proportional, scintillation, and solid-state counters) are described in detail, data-processing systems for these devices are briefly discussed, and the statistics of nuclear counting as applied to X-ray astronomy is outlined analytically. Effects of the near-earth X-ray environment and atmospheric gamma-ray production on X-ray detection by low-orbit satellites are considered. Several contemporary instruments are described (proportional-counter systems, scintillation-counter telescopes, modulation collimators), and X-ray astronomical satellite missions are tabulated.

Peterson, L. E.↗

The Apollo 15 and 16 X-ray fluorescence experiment

An X-ray fluorescence spectrometer was flown aboard the Apollo 15 and 16 spacecrafts orbiting the moon. The X-ray instrument was used to produce a chemical map of that portion of the moon covered by the projected ground tracks and illuminated by the sun during the period of flight. The instrument includes three thin windowed proportional counters, two of which have selected X-ray filters. The field of view of the surface is determined by a collimator, while a detector on the opposite side of the spacecraft provides a continuous monitoring of the solar X-ray output. While the number of chemical elements determined was limited to Mg, Al, and Si, these proved to be very important diagnostic elements.

Adler, I.↗

Atmospheric X-ray Emission Experiment for Shuttle

The Atmospheric X-ray Emission Experiment (AXEE) for Shuttle is designed to measure the spatial, temporal, and energy distribution of X-ray aurorae produced by precipitating electrons. It will provide vital data on solar-terrestrial relationships that may lead to defining the transfer mechanism that causes certain terrestrial weather events and climatological behavior. The instrument concept is based on a spatially sensitive multiwire proportional counter, combined with collimators to produce X-ray images of the aurorae. It will be mounted on an instrument pointing system to provide the required attitude control and is operated by the Spacelab payload specialist who has full control over its observing and data taking modes.

Goldberg, R. A.↗

The Hard X-ray experiment on the Astronomical Netherlands Satellite

The Hard X-ray Experiment flown on the Astronomical Netherlands Satellite is described. The instrument consists of two parts. One is a large-area detector of about 60 sq cm in total area, sensitive in the energy range between 1.5 and 30 keV. Two counters comprise this detector, each collimated 10 min by 3 deg and offset in the narrow direction by 4 min. The other part is a Bragg-crystal assembly consisting of two PET crystals and counters aligned to search for the silicon emission lines near 2 keV. Instrument characteristics and orbital operations are described.

Gursky, H.↗

X-ray nova A0620-00 - Celestial position and low-energy flux

The X-ray nova A0620-00 (Nova Monocerotis 1975) has been observed with the SAS-3 satellite. The 1-10 keV intensity was observed to increase by a factor of 2.3 from August 8 to August 11, 1975. It reached and maintained a constant intensity of 1.7 by 10 to the -6 power erg/sq cm/sec from August 11 to August 13. Limits on periodicities of not more than 2 per cent of the power were obtained for periods from 0.2 ms to 435 s. A precise position was obtained with the SAS-3 modulation collimators on August 15. This led directly to optical and radio identifications. Observations with the SAS-3 low-energy concentrator system on August 27 showed an intense 0.4-0.8 keV flux emanating from the nova. A hydrogen column density of 3.5 (plus or minus 0.3) by 10 to the 21st power per sq cm was inferred from these data.

Doxsey, R.↗

Multistream and Monte Carlo calculations of the sun's aureole

The scattered UV intensities in the sun's aureole are calculated using both a multi-stream scattering method and a Monte Carlo approach. Angular distributions for both Rayleigh and aerosol scatterings are obtained with a realistic atmospheric model. Moderate- and sharply-forward-peaked phase functions of aerosol scattering, corresponding to realistic analytic size distributions, are incorporated. Results from the two independent calculations are in reasonable agreement for a realistic atmospheric model. The results indicate that the scattered UV intensity in the sun's aureole is about four orders smaller than the transmitted intensity while the scattered intensity for pure Rayleigh scattering is only 1-10 millionths times that of the transmitted sun. Based on these intensity ratios, we estimate that the integrated scattered contributions from the aureole to a well-collimated sun photometer of acceptance aperture 2-3 deg are below about 1% of the direct contribution.

Furman, D. R.↗

Visual space perception on a computer graphics night visual attachment

A series of experiments was conducted to compare five psychophysical methods of measuring how people perceive visual space in simulators. Psychologists have used such methods traditionally to measure visual space perception in the real world. Of the five tasks - objective-size judgments, angular-size judgments, shape judgments, slant judgments, and distance judgments - only the angular-size judgment task proved to be of potential use as a measure of simulator realism. In this experiment pilots estimated the relative angular size of triangles placed at various distances along a simulated runway. Estimates made when the display was collimated were closer to real-world performance than estimates made with an uncollimated display.

Palmer, E.↗

Difference thresholds for judgments of sink rate during the flare

Past studies have shown that touchdown rates of descent (sink rates) are higher in aircraft simulators than in aircraft under similar conditions. The objective of this paper was to use a psychophysical technique to investigate a pilot's ability to distinguish between two different sink rates close to the ground. The pilots observed a collimated computer graphics display of a typical runway with edge, zone, and centerline lights. The results showed that with a forward velocity of 120 knots, pilots could reliably distinguish between a sink rate of 0.5 m/sec (1.7 ft/sec) and 0.9 m/sec (2.9 ft/sec). The results also showed that the absolute rate of sink did not significantly affect the perception of sink rate. Time of sink and total height drop during the sink did affect the minimum detectable difference between sink rates (the differential threshold). The effects were such that a greater time of sink and greater height drop produced lower thresholds

Palmer, E.↗

An X-ray survey of BL Lacertae objects

Results are reported for X-ray observations and nearly simultaneous photographic photometry of four BL Lacertae objects (BL Lac, W Com, ON 325, and AP Lib). The X-ray data were obtained in the band from 2.5 to 7.5 keV using a collimated proportional counter aboard OAO-C. Although none of the sources was detected above background at a statistically significant level, two-sigma upper limits on the X-ray flux incident at earth are given for each object. The photometric data indicate that all four objects were near the faint end of their visibility ranges during the time of the X-ray observations. The X-ray upper limits and B magnitudes are employed to calculate upper limits on the brightness temperatures and angular sizes of the radio synchrotron sources; upper limits on the distances to the objects are obtained from limits on the physical source sizes deduced from the radio variabilities. The strictest distance limit is 240 Mpc for BL Lac. Substantial evidence is noted for variability of ON 325 on a timescale of hours.

Margon, B.↗

Recurrent brief X-ray bursts from the globular cluster NGC 6624

Observational data are presented on ten brief X-ray bursts, recurrent at nearly equal time intervals, recorded during a two-day observation of 3U 1820-30 in the globular cluster NGC 6624 with the wide-field modulation collimator detectors on the SAS-3 X-ray observatory. The occurrence times were fitted by least squares to a linear sequence with an rms deviation of 621 sec, corresponding to a phase jitter of 3.9%. The bursts were observed in two energy channels. For a sequence of five of the most clearly observed bursts, the 2-6 keV rate rose to its peak value in about 1 sec and then decayed to preburst level in about 10 sec. The 6-11 keV rate rose more slowly and decayed similarly. The smooth decay of their averaged light curve suggests the temporal evolution may have a geometrical origin, where Compton scattering in a surrounding cloud of hot plasma stretches the pulse out and causes a progressive hardening of the spectrum.

Clark, G. W.↗

A coherent light scanner for optical processing of large format transparencies

A laser scanner is discussed in which the scanning beam is random-access addressable and perpendicular to the image input plane and the irradiance of the scanned beam is controlled so that a constant average irradiance is maintained after passage through the image plane. The scanner's optical system and design are described, and its performance is evaluated. It is noted that with this scanner, data in the form of large-format transparencies can be processed without the expense, space, maintenance, and precautions attendant to the operation of a high-power laser with large-aperture collimating optics. It is shown that the scanned format as well as the diameter of the scanning beam may be increased by simple design modifications and that higher scan rates can be achieved at the expense of resolution by employing acousto-optic deflectors with different relay optics.

Callen, W. R.↗

Dust-contamination monitor

Compact instrument gives instantaneous reading of accumulation of small particles on glass plate. Instrument is sensitive to particles as small as one hundred microns and should be adaptable to monitoring particulate air pollution or dust levels in semiconductor clean rooms. Dual collimated light sources produce highly monochromatic radiation direct at grazing single angle onto glass plate.

Claysmith, C. R.↗

Industrial ion source technology

A 30 cm electron bombardment ion source was designed and fabricated for micromachining and sputtering applications. This source has a multipole magnetic field that employs permanent magnets between permeable pole pieces. An average ion current density of 1 ma/sq cm with 500 eV argon ions was selected as a design operating condition. The ion beam at this operating condition was uniform and well collimated, with an average variation of plus or minus 5 percent over the center 20 cm of the beam at distances up to 30 cm from the ion source. A variety of sputtering applications were undertaken with a small 10 cm ion source to better understand the ion source requirements in these applications. The results of these experimental studies are also included.

Kaufman, H. R.↗

The O(3P) and N(4S) density measurement at 225 km by ultraviolet absorption and fluorescence in the Apollo-Soyuz test project

The densities of O(3P) and N(4S) at 225 km were determined during the Apollo Soyuz Test Project by a resonance absorption/fluorescence technique in which OI and NI line radiation produced and collimated on board the Apollo was reflected from the Soyuz back to the Apollo for spectral analysis. The two spacecraft maneuvered so that a range of observation angles of plus or minus 15 deg with respect to the normal to the orbital velocity vector was scanned. The measurements were made at night on two consecutive orbits at spacecraft separations of 150 and 500 m. The resulting relative counting rates as function of observation angle were compared to calculated values to determine the oxygen value. This value agrees with mass spectrometric measurements made under similar conditions. The nitrogen value is in good agreement with other measurements and suggests a smaller diurnal variation than is predicted by present models.

Kaufman, F.↗

Pseudo-backscatter laser Doppler velocimeter employing antiparallel-reflector in the forward direction

A laser Doppler velocimeter for measuring the velocity of a flowing fluid was discussed. It comprises laser means for providing first and second beams of collimated coherent monochromatic electromagnetic radiation which are focused to intersect at a predetermined location in a flowing fluid. The movement of the particles of the fluid serve to scatter radiation in substantially all directions. The scattered radiation is shifted in frequency from that of the first beam by an amount corresponding to the velocity of the fluid at the predetermined location. A corner cube is disposed generally forward of the predetermined location, the corner cube responding to a portion of the radiation scattered in the forward direction and being operative to reflect the portion in a direction substantially antiparallel to the forward direction.

Gunter, W. D., Jr.↗

Method and apparatus for producing an image from a transparent object

The contrast produced from a photographic transparency is controlled by placing the transparency between a pair of partially reflecting mirrors forming walls of an optical cavity. Mirrors trap a collimated laser beam illuminating the transparency so that at least a portion of the beam energy is passed through the transparency plural times. The distance that the light beam travels between the mirrors is controlled as a function of the wavelength of the beam energy to control the phase of light interference in the beam passing through the transparency, thereby controlling the intensity of the beam derived from the mirror downstream of the transparency.

Lee, S. H.↗

Application of ion thruster technology to a 30-cm multipole sputtering ion source

A 30-cm electron-bombardment ion source has been designed and fabricated for micromachining and sputtering applications. This source has a multipole magnetic field that employs permanent magnets between permeable pole pieces. An average ion current density of 1 ma/sq cm with 500-eV argon ions was selected as a design operating condition. The ion beam at this operating condition was uniform and well collimated, with an average variation of + or -5 percent over the center 20 cm of the beam at a distance up to 30 cm from the ion source.

Robinson, R. S.↗