Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coherence imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Merging single-shot XFEL diffraction data from inorganic nanoparticles: a new approach to size and orientation determination

X-ray free-electron lasers (XFELs) provide new opportunities for structure determination of biomolecules, viruses and nanomaterials. With unprecedented peak brilliance and ultra-short pulse duration, XFELs can tolerate higher X-ray doses by exploiting the femtosecond-scale exposure time, and can thus go beyond the resolution limits achieved with conventional X-ray diffraction imaging techniques. Using XFELs, it is possible to collect scattering information from single particles at high resolution, however particle heterogeneity and unknown orientations complicate data merging in three-dimensional space. Using the Linac Coherent Light Source (LCLS), synthetic inorganic nanocrystals with a core–shell architecture were used as a model system for proof-of-principle coherent diffractive single-particle imaging experiments. To deal with the heterogeneity of the core–shell particles, new computational methods have been developed to extract the particle size and orientation from the scattering data to assist data merging. The size distribution agrees with that obtained by electron microscopy and the merged data support a model with a core–shell architecture.

36 MATERIALS SCIENCE↗

Bimodal imaging of functional changes in blood flow using optoacoustic and optical coherent angiography

The results of a complementary study of functional changes of the blood flow in human superficial tissues using optoacoustic (OA) microscopy and angiographic optical coherent tomography (OCT-A) during an occlusive test are demonstrated for the first time. OA microscopy data allow one to estimate the increase in blood content during the occlusive test, while OCT-A data demonstrate a decrease in the number of vessels with a functioning blood flow in the area of interest. The combined approach reported in the paper can be employed in experimental and clinical medicine to study the functional changes of microcirculation in diagnostics of vascular pathologies of superficial tissues and to evaluate the microcirculation response to treatment. (paper)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Rayleigh-Taylor Instability: Statistics on Rising Bubbles and Falling Spikes

The analysis of coherent structures in Rayleigh-Taylor simulations is a challenging task as the lack of a precise definition of these structures is compounded by the massive size of the datasets. In an earlier work, we used techniques from image analysis to count these coherent structures in two high-resolution simulations, one a large-eddy simulation with 30 terabytes of analysis data, and the other a direct numerical simulation with 80 terabytes of analysis data. Our analysis indicated that there were four distinct regimes in the process of the mixing of the two fluids, starting from the initial linear stage, followed by the non-linear stage with weak turbulence, the mixing transition stage, and the final stage of strong turbulence. In this paper, we extend our earlier work to focus on only the rising bubbles and the falling spikes. We first consider different ways in which we can constrain the bubble and spike definitions and then extract various statistics on them. Our results on the rising bubble and falling spike counts again show that there are four regimes in the process of fluid mixing, each characterized by an integer-valued slope. Further, the average bubble heights and spike depths are related to similar results obtained using a threshold-based definition. Finally, the ratio of the rising bubbles to all bubbles is very similar in character to the ratio of the falling spikes to all spikes, with near constant values over part of the simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic-Resolution Imaging with a Sub-50-pm Electron Probe

Using a highly coherent focused electron probe in a fifth-order aberration-corrected transmission electron microscope, we report on resolving a crystal spacing less than 50 pm. Based on the geometrical source size and residual coherent and incoherent axial lens aberrations, an electron probe is calculated, which is theoretically capable of resolving an ideal 47 pm spacing with 29% contrast. Our experimental data show the 47 pm spacing of a Ge <114> crystal imaged with 11%-18% contrast at a 60%-95% confidence level, providing the first direct evidence for sub-50-pm resolution in annular dark-field scanning transmission electron microscopy imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Incorrect support and missing center tolerances of phasing algorithms

In x-ray diffraction microscopy, iterative algorithms retrieve reciprocal space phase information, and a real space image, from an object's coherent diffraction intensities through the use of a priori information such as a finite support constraint. In many experiments, the object's shape or support is not well known, and the diffraction pattern is incompletely measured. We describe here computer simulations to look at the effects of both of these possible errors when using several common reconstruction algorithms. Overly tight object supports prevent successful convergence; however, we show that this can often be recognized through pathological behavior of the phase retrieval transfer function. Dynamic range limitations often make it difficult to record the central speckles of the diffraction pattern. We show that this leads to increasing artifacts in the image when the number of missing central speckles exceeds about 10, and that the removal of unconstrained modes from the reconstructed image is helpful only when the number of missing central speckles is less than about 50. In conclusion, this simulation study helps in judging the reconstructability of experimentally recorded coherent diffraction patterns.

36 MATERIALS SCIENCE↗

A Design Report for the Optical Transition Radiation Imager for the LCLS Undulator

The Linac Coherent Light Source (LCLS), a free-electron x-ray laser, is under design and construction. Its high-intensity electron beam, 3400 A in peak current and 46 TW in peak power, is concentrated in a small area (37 micrometer in rms radius) inside its undulator. Ten optical transition radiation (OTR) imagers are planned between the undulator segments for characterizing the transverse profiles of the electron beam. In this note, we report on the optical and mechanical design of the OTR imager. Through a unique optical arrangement, using a near-normal-incidence screen and a multi-layer coated mirror, this imager will achieve a fine resolution (12 micrometer or better) over the entire field of view (8 mm x 5 mm), with a high efficiency for single-shot imaging. A digital camera will be used to read out the beam images in a programmable region (5 mm x 0.5 mm) at the full beam repetition rate (120 Hz), or over the entire field at a lower rate (10 Hz). Its built-in programmable amplifier will be used as an electronic intensity control.

43 PARTICLE ACCELERATORS↗

SISGR: Room Temperature Single-Molecule Detection and Imaging by Stimulated Emission Microscopy

Single-molecule spectroscopy has made considerable impact on many disciplines including chemistry, physics, and biology. To date, most single-molecule spectroscopy work is accomplished by detecting fluorescence. On the other hand, many naturally occurring chromophores, such as retinal, hemoglobin and cytochromes, do not have detectable fluorescence. There is an emerging need for single-molecule spectroscopy techniques that do not require fluorescence. In the last proposal period, we have successfully demonstrated stimulated emission microscopy, single molecule absorption, and stimulated Raman microscopy based on a high-frequency modulation transfer technique. These first-of-a- kind new spectroscopy/microscopy methods tremendously improved our ability to observe molecules that fluorescence weakly, even to the limit of single molecule detection for absorption measurement. All of these methods employ two laser beams: one (pump beam) excites a single molecule to a real or virtual excited state, and the other (probe beam) monitors the absorption/emission property of the single. We extract the intensity change of the probe beam with high sensitivity by implementing a high-frequency phase-sensitive detection scheme, which offers orders of magnitude improvement in detection sensitivity over direct absorption/emission measurement. However, single molecule detection based on fluorescence or absorption is fundamentally limited due to their broad spectral response. It is important to explore other avenues in single molecule detection and imaging which provides higher molecular specificity for studying a wide variety of heterogeneous chemical and biological systems. This proposal aimed to achieve single-molecule detection sensitivity with near resonance stimulated Raman scattering (SRS) microscopy. SRS microscopy was developed in our lab as a powerful technique for imaging heterogeneous samples based on their intrinsic vibrational contrasts, which provides much higher molecular specificity than absorption and fluorescence. Current sensitivity limit of SRS microscopy has not yet reached single molecule detection. We proposed to capitalize on our state-of-the-art SRS microscopy and develop near-resonance enhanced SRS for single molecule detection of carotenoids and heme proteins. The specific aims we pursued are: (1) building the next SRS generation microscope that utilizes near resonance enhancement to allow detection and imaging of single molecules with undetectable fluorescence, such as -carotene. (2) using near-resonance SRS as a contrast mechanism to study dye-sensitize semiconductor interface, elucidating the heterogeneous electron ejection kinetics with high spatial and temporal resolution. (3) studying the binding and unbinding of oxygen in single hemoglobin molecules in order to gain molecular level understanding of the long-standing issue of cooperativity. The new methods developed in the fund period of this grant have advanced the detection sensitivity in many aspects. Near-resonance SRS improved the signal by using shorter wavelengths for SRS microscopy. Frequency modulation and multi-color SRS target the reduction of background to improve the chemical specificity of SRS while maintaining the high imaging speed. Time-domain coherent Raman scattering microscopy targets to reduce the noise floor of coherent Raman microscopy. These methods have already demonstrated first-of-a-kind new applications in biology and medical research. However, we are still one order of magnitude away from single molecule limit. It is important to continue to improve the laser specification and develop new imaging methods to finally achieve label-free single molecule microscopy.

47 OTHER INSTRUMENTATION↗

Reflectance spectra from eutrophic Mono Lake California, measured with the Airborne Visible and Infrared Imaging Spectrometer (AVIRIS)

An AVIRIS image was obtained for Mono Lake, California, on May 26, 1989, a day with excellent visibility. Atmospherically-corrected reflectance spectra derived from the image indicate a spectral signature for chlorophyll a, the dominant photosynthetic pigment in the phytoplankton of the lake. Chlorophyll a concentrations in the lake were about 22 mg/cu m, and the upwelling radiance was low with a peak reflectance at about 570 nm of about 5 percent. Coherent noise appeared in the image as regular variations of 0.1 to 0.2 microwatts/sq cm per str oriented diagonally to the flight line. A simple ratio of two spectral bands removed the conspicuous undulations, but modifications of the shielding within the instrument are needed to improve the signal especially over dark targets such as lakes.

Melack, John M.↗

Spectrally filtered fast imaging of internal magnetohydrodynamic activity in the DIII-D tokamak

The detailed poloidal structure of internal magnetohydrodynamic (MHD) modes is imaged using broadband visible bremsstrahlung emission from the core of the DIII-D tokamak. Spectral analysis of individual pixel time series recorded by a fast framing camera (up to 26 000 frames/s at 256x256 spatial resolution) is used to reconstruct two-dimensional images of mode amplitude. Application of this spectrally filtered fast imaging (SFFI) technique reveals spatially extended coherent structures that correspond to a (m,n)=(1,1) kink mode and a (2,1) neoclassical tearing mode rotating in the laboratory frame. The SFFI technique produces images with significantly less noise than images produced with the commonly used background subtraction method. Extension of SFFI to other core MHD events and coherent fluctuations in general is straightforward and could lead to further understanding of core MHD activity in fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility study of an optically coherent telescope array in space

Numerical methods of image construction which can be used to produce very high angular resolution images at optical wavelengths of astronomical objects from an orbiting array of telescopes are discussed and a concept is presented for a phase-coherent optical telescope array which may be deployed by space shuttle in the 1990's. The system would start as a four-element linear array with a 12 m baseline. The initial module is a minimum redundant array with a photon-counting collecting area three times larger than space telescope and a one dimensional resolution of better than 0.01 arc seconds in the visible range. Later additions to the array would build up facility capability. The advantages of a VLBI observatory in space are considered as well as apertures for the telescopes.

Traub, W. A.↗

Interference Mitigation Effects on Synthetic Aperture Radar Coherent Data Products

For synthetic aperture radars radio frequency interference from sources external to the radar system and techniques to mitigate the interference can degrade the quality of the image products. Usually the radar system designer will try to balance the amount of mitigation for an acceptable amount of interference to optimize the image quality. This dissertation examines the effect of interference mitigation upon coherent data products of fine resolution, high frequency synthetic aperture radars using stretch processing. Novel interference mitigation techniques are introduced that operate on single or multiple apertures of data that increase average coherence compared to existing techniques. New metrics are applied to evaluate multiple mitigation techniques for image quality and average coherence. The underlying mechanism for interference mitigation techniques that affect coherence is revealed.

42 ENGINEERING↗

Imaging population transfer in atoms with ultrafast electron pulses

Here, we propose the use of ultrafast electron diffraction (UED) to image a controllable, laser-driven coherent electron population transfer in lithium atoms with currently available femtosecond electron pulses. Our simulations demonstrate the ability of ultrafast electrons to image such an electronic population transfer, thus validating UED as a direct means of investigating electron dynamics. Provided the incident electron pulses have sufficient temporal resolution, the diffraction images are shown to resolve also the relative phases of the target electronic wave functions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Real-time incoherent-to-coherent optical converter

Description of a real-time incoherent-to-coherent optical converter designed for application in image processing systems. The converter utilizes the photoconductivity effect of the compound Bi(12)SiO(20) for spatial modulation of electrical polarization in the compound. An optically absorbed write-in image is stored as an image polarization pattern in the device. Readout is effectuated electrooptically by using phase retardation in a polarized coherent light beam during the passage through the crystal. The operating mode required for achieving continuous image conversion with a high-speed recyclability is discussed. The performance characteristics of the converter are given and the fabrication technology is described.

Vohl, P.↗

Doppler optical coherence microscopy and tomography applied to inner ear mechanics

While it is clear that cochlear traveling waves underlie the extraordinary sensitivity, frequency selectivity, and dynamic range of mammalian hearing, the underlying micromechanical mechanisms remain unresolved. Recent advances in low coherence measurement techniques show promise over traditional laser Doppler vibrometry and video microscopy, which are limited by low reflectivities of cochlear structures and restricted optical access. Doppler optical coherence tomography (DOCT) and Doppler optical coherence microscopy (DOCM) both utilize a broadband source to limit constructive interference of scattered light to a small axial depth called a coherence gate. The coherence gate can be swept axially to image and measure sub-nanometer motions of cochlear structures throughout the cochlear partition. The coherence gate of DOCT is generally narrower than the confocal gate of the focusing optics, enabling increased axial resolution (typically 15 μm) within optical sections of the cochlear partition. DOCM, frequently implemented in the time domain, centers the coherence gate on the focal plane, achieving enhanced lateral and axial resolution when the confocal gate is narrower than the coherence gate. We compare these two complementary systems and demonstrate their utility in studying cellular and micromechanical mechanisms involved in mammalian hearing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rapid and noncontact photoacoustic tomography imaging system using an interferometer with high-speed phase modulation technique

We designed, fabricated, and tested a rapid and noncontact photoacoustic tomography (PAT) imaging system using a low-coherence interferometer with high-speed phase modulation technique. Such a rapid and noncontact probing system can greatly decrease the time of imaging. The proposed PAT imaging system is experimentally verified by capturing images of a simulated tissue sample and the blood vessels within the ear flap of a mouse (pinna) in vivo. The axial and lateral resolutions of the system are evaluated at 45 and ∼15 μm, respectively. The imaging depth of the system is 1 mm in a special phantom. Our results show that the proposed system opens a promising way to realize noncontact, real-time PAT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging with a 90 frames/s microbolometer focal plane array and high-power terahertz free electron laser

An uncooled microbolometer focal plane array (FPA) has been developed and used for imaging of objects illuminated by monochromatic coherent radiation of a free electron laser tunable in the range of 1.25-2.5 THz. A sensitivity threshold of 1.3x10{sup -3} W/cm{sup 2} was obtained for the FPA with a homemade absolute interferometric power meter. Videos up to 90 frames/s were recorded in both transmission and reflection/scattering modes. When objects were illuminated by laser radiation scattered by a rough metal surface, speckled images were observed. Good quality terahertz images were achieved through the fast rotation of the scatterer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multigrid Optimization for Large-Scale Ptychographic Phase Retrieval

Ptychography is a popular imaging technique that combines diffractive imaging with scanning microscopy. The technique consists of a coherent beam that is scanned across an object in a series of overlapping positions, leading to reliable and improved reconstructions. Ptychographic microscopes allow for large fields to be imaged at high resolution at the cost of additional computational expense. Herein, we propose a multigrid-based optimization framework to reduce the computational burdens of large-scale ptychographic phase retrieval. Our proposed method exploits the inherent hierarchical structures in ptychography through tailored restriction and prolongation operators for the object and data domains. Our numerical results show that our proposed scheme accelerates the convergence of its underlying solver and outperforms the ptychographical iterative engine, a workhorse in the optics community.

97 MATHEMATICS AND COMPUTING↗