Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “closed loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

H ∞ Control for Energy Dispatch in Autonomous Nanogrid With Communication Delays

This paper proposes an optimal controller and estimator for energy dispatch to balance the power supply and demand considering communication delays. The proposed algorithm involves modeling an autonomous nanogrid (ANG) consisting of distributed energy resources, energy storage systems, loads, an $H$ ∞ controller with a reference power modulation technique, and a state estimator. The ANG was developed to express the dynamic supply-demand energy balance of a nanogird system. Reference power modulation was designed to generate the desired ESS power based on the imbalanced energy. Random communication delays were modeled using a stochastic variable satisfying the Bernoulli random binary distribution. The optimal $H$ ∞ controller and estimator were developed using a linear matrix inequality approach to exponentially stabilize the closed-loop system. Simulations were performed using real daily demand forecasts obtained from the Korea Meteorological Administration to demonstrate the effectiveness of the proposed real-time optimization algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution System Congestion Management - A Survey of Reliable Integration for Aggregated Resources and Microgrids

Rising penetration of consumer-owned Distribution Grid Resources (DGRs), increasingly managed by third party aggregators and enrolled in grid services and wholesale market programs, can create localized congestion in distribution networks. Managing these constraints is challenging due to a persistent coordination and information gap: utilities are accountable for reliability and have network topology and state visibility, while aggregators control the DGR capability needed to relieve congestion. This survey synthesizes congestion management solutions for distribution systems with high DGR penetration, covering both market-based mechanisms (distribution level markets, locational pricing, flexibility auctions) and non-market-based solutions (network reconfiguration, direct DGR control, demand response, curtailment, etc.). The literature is organized across three decision horizons: long term planning, operational planning, and real-time operation. Special attention is devoted to emerging distribution system operator architectures and coordination frameworks spanning transmission system operators, aggregators, and microgrids. Drawing on recent case studies and implementations, we distill best practices, identify key technical and economic barriers, and outline research directions. The evidence points to a shift toward integrated congestion management that combines market signals with technical controls, enabled by improved monitoring, forecasting, and closed loop control capabilities.

Active Distribution Networks (ADN)↗

Design of a Single Controller for Multiple Paralleled Inverters

Paralleling power electronics inverters is an effective way to increase dc-ac system power level. Accurately synchronized switching action and independent closed-loop regulator are necessary to prevent circulating current in paralleled inverters. There are many challenges for the controller design, when the number of paralleled inverters is large, and control period gets short for high switching frequency applications. This paper presents a single controller design based on DSP + FPGA that is suitable for paralleling multiple inverters. A simple synchronization scheme between DSP and FPGA based on universal parallel port (UPP) is proposed to eliminate the synchronization delay among inverters, and independent control of each converter can also be implemented. The controller is built for a system consisting of 4 paralleled three-level, three-phase high frequency ANPC inverters using space vector modulation, and it can be easily adopted to other topologies and modulations. Experimental results have demonstrated the effectiveness of this controller.

Niu, Jiahao↗

A Control Scheme to Mitigate the Dead-Time Effects in a Wireless Power Transfer System

In practice, a dead-time is always provided between the complementary switching instances of the inverter phase-leg devices. At higher operating frequencies, the dead-time issues in wireless power transfer (WPT) systems become critical, especially as the power level increases. In certain operating conditions, the dead-time effect in wireless power transfer system affects the switching characteristics. Consequently, the switching losses in the power semiconductor devices increase and also impact the efficiency of the overall system. In this paper, a simple control scheme is proposed to eliminate the dead-time effect (or voltage polarity reversal) in the WPT inverter. The proposed control scheme monitors the inverter output voltage, and the switching frequency is auto-tuned to eliminate the undesired switching instances in the inverter voltage. The proposed control scheme is validated using the closed-loop simulations in PLECS, and the experimental results on a 5.6 kW WPT prototype are also presented. After eliminating the voltage-polarity-reversal at the inverter output, the inverter losses were reduced by ~40%, and the overall system losses were reduced by ~17%.

Kavimandan, Utkarsh↗

A Novel AC to AC Wireless Power Transfer System for EV Charging Applications

In this paper, a novel ac to ac wireless power transfer (WPT) system is introduced for electric vehicle (EV) charging applications to reduce cost and design complexity. The presented wireless power transfer concept achieves unity power factor (UPF) on the grid-side by using a hybrid frequency ac / ac converter without an additional converter stage and closed loop control compared to the conventional systems. Due to inherent merit of the proposed ac / ac converter, ac input with 60 Hz grid frequency can be directly transferred to the load by superimposing with high frequency switching signal through the wireless coils. To validate the theoretical analysis of the proposed WPT system, the experimental results of the proposed converter are provided for 650 W output power by using 6 inches air gap between the couplers with the input of 110 VRMS ac source. The system overall efficiency is measured 89 % achieving 0.99 power factor (PF) and 1.5 % current total harmonic distortion (THD).

Asa, Erdem↗

Poloidal flux profile reconstruction from pointwise measurements via extended Kalman filtering in the DIII-D Tokamak

The accuracy of the internal states of a tokamak, which usually cannot be measured directly, is of crucial importance for feedback control of the plasma dynamics. A first-principles-driven plasma response model could provide an estimation of the internal states given the boundary conditions on the magnetic axis and at plasma boundary. However, the estimation would highly depend on initial conditions, which may not always be known, disturbances, and non-modeled dynamics. Here in this work, a closed-loop state observer for the poloidal magnetic flux is proposed based on a very limited set of real-time measurements by following an Extended Kalman Filtering (EKF) approach. Comparisons between estimated and measured magnetic flux profiles are carried out for several discharges in the DIII-D tokamak. The experimental results illustrate the capability of the proposed observer in dealing with incorrect initial conditions and measurement noise.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Invited: Software defined accelerators from learning tools environment

Next generation systems, such as edge devices, will need to provide efficient processing of machine learning (ML) algorithms along several metrics, including energy, performance, area, and latency. However, the quickly evolving field of ML makes it extremely difficult to generate accelerators able to support a wide variety of algorithms. At the same time, designing accelerators in hardware description languages (HDLs) by hand is hard and time consuming, and does not allow quick exploration of the design space. In this paper we present the Software Defined Accelerators From Learning Tools Environment (SODALITE), an automated open source high-level ML framework-to-verilog compiler targeting ML Application-Specific Integrated Circuits (ASICs) chiplets. The SODALITE approach will implement optimal designs by seamlessly combining custom components generated through high-level synthesis (HLS) with templated and fully tunable Intellectural Properties (IPs) and macros, integrated in an extendable resource library. Through a closed loop design space exploration engine, developers will be able to quickly explore their hardware designs along different dimensions.

High-Level Synthesis, Accelerators, Hardware-Softw↗

A Novel Discharging Control Strategy for Modular Multilevel Converter Submodules without Using External Circuit

A novel discharging control strategy is proposed and implemented for submodules in modular multilevel converters (MMCs). By sequentially controlling the arm currents of a MMC to the arm resistors, all submodule capacitors are discharged safely and rapidly without adding additional devices and circuits, resulting in improved performance and reduced cost. Both open- and closed-loop control methods are evaluated for effectiveness of the new control strategy. Simulation and experimental results are provided to validate the new control strategy.

Modular multilevel converter, discharging method, ↗

Model-based Cyber-attack Detection for Voltage Source Converters in Island Microgrids

With the upgrading of communication and control in microgrids, cyber threats on the power converters are increasing. Here, in this paper, a novel model-based cyber-attack detection methodology is proposed for each voltage source converter in microgrids. The Harmonics State Space Matrix (H-Matrix) is used to build the closed-loop transfer function, providing model-based estimation with the grid voltage and control reference. Then, the space phase model (SPM) is used to calculate residual to detect cyber-attacks in voltage source converter (VSC). As controller and converter parameters are included in the H-matrix, the proposed method also could detect cyber-attacks when voltage fluctuation occurs in the grid. To verify the feasibility of the proposed method, several attacks targeting VSC in an islanded microgrid are simulated in MATLAB. Simulation and detection results are introduced to demonstrate the resilience and feasibility of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control and Grid Support Function Evaluation for a Three-Phase Back-to-Back Modular Multilevel Converter System

This paper focuses on the evaluation of advanced inverter controls for a 500kW back-to-back (B2B), silicon carbide, multilevel modular converter (MMC) used as a direct-connected medium-voltage grid intertie. A decentralized hierarchical controller architecture for the MMC system is presented, which uses the main controller to implement higher level grid interconnection functions per the IEEE 1547–2018 standards and the local controllers to execute lower level closed-loop functionality of the MMC stages. This paper presents and elaborates on the grid functionalities are elaborated and presented. The back-to-back converter system is equipped with local controllers and their corresponding functionalities are presented. Case study results for the corresponding functionalities presented show the effectiveness of the proposed architecture. To enhance the operation capabilities of the system, a parameter update scheme has been implemented and utilized in unison with the controller.

decentralized control↗

Demand Driven Energy Management for PIPO Auxiliary Power Supply Architecture

In this paper, a demand driven energy management (DDEM) technique is implemented on modular parallel input parallel output DC/DC auxiliary power supply (APS) structure. In this method, modules are brought in/out of the operation making them operate under high loading conditions, avoiding low efficiency under light load. Such a method finds its application in power conservative systems with variable load. Implementation of DDEM and the energy saved is shown using APS comprised of two 15W commercially off-the-shelf DC-DC modules, with 100–1000 VDC input and 24 V output voltage. Along with the DDEM, the lifetime of the power stage devices is controlled minimizing their junction temperature swing through control of cooling system. This control method uses digital twin as interface to virtualize the power devices loading operation/ health condition. Accordingly, no extra sensor or closed loop control required to measure the junction temperature of the devices or feedback the losses to the cooling flow.

Azadeh, Yalda↗

On Stability of PQ-Controlled Grid-Following and Droop-Control Grid-Forming Inverters

In this paper, the nonlinearity impacts of PQ-control schemes and LCL filter parameter variations on the stability of grid-interactive inverters are studied under weak grid conditions. This work demonstrates that the control nonlinearity and parameter variations can cause unexpected instability at low power levels. This instability issue in the nominal operating range may occur under specific control parameters due to the shift of the low-frequency eigenvalues of PQ-controlled inverters. A full-order small-signal model for PQ-controlled inverters is applied to analyze this instability issue. Furthermore, the impacts of the droop coefficients on the stability of the droop-controlled grid-forming inverter are also investigated using the closed-loop inverter model. The findings are experimentally verified using a small-scale two-level 208 V, 5 kVA inverter feeding a 12 kW NHR 9410 power grid emulator and a hardware setup of a microgrid fed by two 5 kVA 208V inverters.

Hossen, Tareq↗

Output Current Estimation and Control in Primary Side LCC Secondary Side Series Compensated Wireless Power Transfer System without Secondary Side Sensors

The estimation (and control) of the output variables is often challenging for wireless power transfer (WPT) systems. This paper presents a secondary side sensor-less closed loop estimation technique to estimate the output current in a primary side LCC and secondary side series compensated WPT system. Using information of primary side variables, the proposed estimation can estimate the output current over a wide range of load current variations. Results are presented to verify the efficacy of the proposed estimation.

Mukherjee, Subho [ORNL] (ORCID:0009000672297925)↗

Real-time Simulation Model of a Vanadium Redox Flow Battery Energy Storage System with Power Electronics Integration

This paper presents a real-time (RT) model of a 20 kW multi-stack vanadium redox flow battery (VRFB) system including power electronics converters in a single real-time framework. Implemented on a Typhoon HIL 604 device, this model is designed to simulate the operation of the flow battery with system-level controls. To provide a realistic overview of a VRFB system, the model incorporates a closed-loop control system for managing the speeds of two centrifugal pumps and an electro-thermal model of the battery stacks, enabling realtime temperature estimation. Furthermore, a two-stage power electronics topology and associated control solution are presented, operating with distinct strategies for interfacing the battery model with the main grid and a local load. Results from simulations demonstrate that the VRFB model is well suited for RT environment, and system can manage power during both charging and discharging cycles, while a SCADA monitor is used to display critical variables for safe, efficient, and reliable operation of the VRFB systems.

Rezende Da Costa Reis Kimpara, Renata [ORNL] (ORCI↗

Ground Vehicle Generalized Forces and Moment Governor Design Via Noncertainty-Equivalent Adaptive Prescribed Performance Control

Torque-vectoring technology demonstrates great potential in improving the safety and performance of ground vehicles. In this paper, a novel generalized forces and moment governor for torque vectoring is suggested. The proposed solution strategically combines prescribed performance control, noncertainty equivalent adaptive control design, and a smooth projection operator. The main advantage of the proposed control strategy lies in its capability to guarantee both the transient performance and prompt recovery of the desired deterministic behavior of the closed-loop adaptive system, even in the presence of parametric uncertainties. ASM simulation results are presented to validate the efficacy of the proposed generalized forces and moment governor and to demonstrate its superiority over a baseline solution.

Zhou, Xingyu↗

Adaptive Path-Following Control for Ground Vehicles Using a Switching Non-Quadratic Lyapunov Function

The application of adaptive control techniques in the development of control systems for intelligent vehicles, especially for ground vehicle path-following controllers, has gained popularity due to their ability to handle large-scale parametric uncertainties. However, the use of a standard quadratic Lyapunov function in existing adaptive control-based path-following controllers can lead to poor transient performance, such as slow convergence and/or large overshoot. To address this limitation, this study proposes the use of a switching non-quadratic Lyapunov function to design a model reference adaptive path-following controller that aims to provide superior transient performance. The stability and signal convergence of the closed-loop system are demonstrated through a Lyapunov-like analysis. Through dSPACE ASM simulation, the effectiveness of the proposed controller is illustrated, which confirms improved tracking performance over a baseline solution.

Zhou, Xingyu↗

Establishing Models for Digital Twin of Hydropower Systems Using Probability Density Function Shaping

This paper introduces a digital twin modeling method for hydropower systems with Kaplan turbines using probability density function (PDF) shaping. We first use multilayer perceptron (MLP) model to build the discretized openloop Kaplan unit, where the MLP is trained by historical data. Then we use a proportional integral double derivative (PIDD) controller and a lead-lag exciter to test the obtained digital twin model in a closed-loop fashion. Simulation results show that the proposed digital twin modeling method can accurately capture the dynamics of the Kaplan hydropower unit. Finally, we show that the obtained digital twin can help to optimize the PIDD parameters. Compared with the original PIDD controller, the optimized one can achieve an over 90% improvement on the mean square tracking error.

Yin, Zhun [New York University]↗

Permanent Magnet Synchronous Condenser for Wind Power Plant Grid Connection Support: Preprint

A synchronous condenser (SC) using a permanent magnet synchronous generator (PMSG) is proposed for providing necessary reactive power to a wind power plant to support its connection to a weak grid. A PMSG has the advantage of higher efficiency and reliability. Because of its lack of a field winding, a PMSG is typically controlled by a full-power converter, which can be costly. In the proposed system, the reactive power of the SC is controlled by a serially connected compensator operating in a closed-loop configuration. The compensator also damps the PMSG's tendency to oscillate. The compensator's VA rating is only a fraction of the rating of the SC and the PMSG. In this initial investigation, the proposed scheme is shown to be effective by computer simulations.

17 WIND ENERGY↗