Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calculation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Effect of electron correlation in Sr(Ca)Ru{sub 1-x}Cr{sub x}O{sub 3}: Density functional calculation

We have investigated the electronic structure of Sr(Ca)Ru{sub 1-x}Cr{sub x}O{sub 3} using the full potential linearized augmented plane wave method by different approximation such as LSDA and LSDA+U. The LSDA calculation suggest that Cr{sup 4+}-Ru{sup 4+} hybridization is responsible for the high Curie temperature T{sub C} in SrRu{sub 1-x}Cr{sub x}O{sub 3}, but it cannot completely describe its physical behavior. Our LSDA+U DOS results for SrRu{sub 1-x}Cr{sub x}O{sub 3} clearly establishes renormalization of the intra-atomic exchange strength at the Ru sites, arising from the Cr-Ru hybridization. The antiferromagnetic coupling of Cr{sup 3+} with Ru{sup 4+,5+} lattice increases the screening, which is consistent with the low magnetic moment of the Ru ions. The more distorted Ca-based compounds as compared to the Sr-based systems shows that the hybridization mechanism is not relevant for these compounds. The bigger exchange splitting of Ru 4d and Cr 3d at the Fermi level with Ru{sup 4+,5+} and Cr{sup 3+,4+} orbital occupancies of CaRu{sub 0.75}Cr{sub 0.25}O{sub 3} in the LSDA+U calculation, compared with that of the LSDA calculation, shows that repulsion between electrons tend to keep the localized spins from overlapping. The low screening of the Ru t{sub 2g} electrons increases T{sub C} in the Ca-based systems, which is consistent with the both high Ru exchange splitting and magnetic moment. The insulating behavior of the high Cr-doped systems can be explained by considering the Ru{sup 4+}+Cr{sup 4+{yields}}Ru{sup 5+}+Cr{sup 3+} charge transfer. - Graphical Abstract: We have investigated the electronic structure of Sr(Ca)Ru{sub 1-x}Cr{sub x}O{sub 3} using different ab-initio calculation such as LSDA and LSDA+U approximation. The antiferromagnetic hybridization of Cr{sup 3+} with Ru{sup 4+,5+} lattice increases the screening, which is consistent with the low magnetic moment of the Ru ions. The LSDA+U calculation for the more distorted Cr impurity doped Ca-based ruthenate compounds as compared to the Sr-based systems shows repulsion between electrons, which tends to keep the localized spins from overlapping.

36 MATERIALS SCIENCE↗

String Method for Protein–Protein Binding Free-Energy Calculations

A powerful computational strategy to determine the equilibrium association constant of two macromolecules with explicit-solvent molecular dynamics (MD) simulations is the "geometric route", which considers the reversible physical separation of the bound complex in solution. Nonetheless, multiple challenges remain to render this type of methodology reliable and computationally efficient in practice. In particular, in one, formulation of the geometric route relies on the potential of mean force (PMF) for physically separating the two binding partners restrained along a straight axis, which must be selected prior to the calculation. However, practical applications indicate that the calculation of the separation PMF along the predefined rectilinear pathway may be suboptimal and slowly convergent. Recognizing that a rectilinear straight separation pathway is generally not representative of how the protein complex physically separates in solution, we put forth a novel theoretical framework for binding free-energy calculations, leaning on the optimal curvilinear minimum free-energy path (MFEP) determined from the string method. The proposed formalism is validated by comparing the results obtained using both rectilinear and curvilinear pathways for a prototypical host-guest complex formed by cucurbit[7]uril (CB[7]) binding benzene, and for the barnase-barstar protein complex. On the basis of multi-microsecond MD calculations, we find that the calculations following the traditional rectilinear pathway and the string-based curvilinear pathway agree quantitatively, but convergence is faster with the latter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visible Light Absorption of N-Doped TiO2 Rutile Using (LR/RT)-TDDFT and Active Space EOMCCSD Calculations

We have performed detailed ground and excited state calculations of pure and N-doped TiO2 rutile to model and analyze the experimentally observed UV/Vis spectrum. Using our embedding model we have performed both linear-response (LR) and real-time (RT) TDDFT calculations of the excited states of the pure and N-doped systems. We have also studied the lowest excitations using high-level active space equation-of-motion coupled cluster (EOMCC) approaches involving all single and inter-band double excitations. We compare and contrast the nature of the excitations in detail for the pure and doped systems and also provide an analysis of the excited-state density using our RT-TDDFT calculations. Our calculations indicate a lowering of the band gap and verify the role of the N3- states on the observed spectrum of N-doped TiO2 rutile as suggested by experimental findings. Both RT-TDDFT and EOMCC calculations show that the excitations in pure TiO2 are more delocalized compared with the N-doped system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Embolization Material in the Calculation of Dose Deposition in Arteriovenous Malformations

In this work it is studied the impact of the incorporation of high Z materials (embolization material) in the dose calculation for stereotactic radiosurgery treatment for arteriovenous malformations. A statistical analysis is done to establish the variables that may impact in the dose calculation. To perform the comparison pencil beam (PB) and Monte Carlo (MC) calculation algorithms were used. The comparison between both dose calculations shows that PB overestimates the dose deposited. The statistical analysis, for the quantity of patients of the study (20), shows that the variable that may impact in the dose calculation is the volume of the high Z material in the arteriovenous malformation. Further studies have to be done to establish the clinical impact with the radiosurgery result.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calculation of continuum damping of Alfvén eigenmodes in tokamak and stellarator equilibria

In an ideal magnetohydrodynamic (MHD) plasma, shear Alfvén eigenmodes may experience dissipationless damping due to resonant interaction with the shear Alfvén continuum. This continuum damping can make a significant contribution to the overall growth/decay rate of shear Alfvén eigenmodes, with consequent implications for fast ion transport. One method for calculating continuum damping is to solve the MHD eigenvalue problem over a suitable contour in the complex plane, thereby satisfying the causality condition. Such an approach can be implemented in three-dimensional ideal MHD codes which use the Galerkin method. Analytic functions can be fitted to numerical data for equilibrium quantities in order to determine the value of these quantities along the complex contour. This approach requires less resolution than the established technique of calculating damping as resistivity vanishes and is thus more computationally efficient. The complex contour method has been applied to the three-dimensional finite element ideal MHD Code for Kinetic Alfvén waves. In this paper, we discuss the application of the complex contour technique to calculate the continuum damping of global modes in tokamak as well as torsatron, W7-X and H-1NF stellarator cases. To the authors' knowledge, these stellarator calculations represent the first calculation of continuum damping for eigenmodes in fully three-dimensional equilibria. The continuum damping of global modes in W7-X and H-1NF stellarator configurations investigated is found to depend sensitively on coupling to numerous poloidal and toroidal harmonics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calculation of reinforced-concrete frame strength under a simultaneous static cross section load and a column lateral impact

When designing buildings with reinforced concrete that are planned to resist dynamic loads it is necessary to calculate this structural behavior under operational static and emergency impact and blast loads. Calculations of the structures under shock-wave loads can be performed by solving dynamic equations that do not consider static loads. Due to this fact the calculation of reinforced concrete frame under a simultaneous static and dynamic load in full 3d settings becomes a very non trivial and resource consuming problem. This problem can be split into two tasks. The first one is a shock-wave problem that can be solved using software package RANET-3, which allows solving the problem using finite elements method adapted for dynamic task. This method calculates strain-stress state of the material and its dynamic destruction, which is considered as growth and consolidation of micro defects under loading. On the second step the results of the first step are taken as input parameters for quasi static calculation of simultaneous static and dynamic load using finite elements method in AMP Civil Engineering-11.

36 MATERIALS SCIENCE↗

The origin of linear scaling Fock matrix calculation with density prescreening

A theorem was proven, which reads that the number of nonzero two-electron integrals scales linearly with respect to the number of basis functions for large molecular systems. This permits to show that linear scaling property of the Fock matrix calculation with using density prescreening arises due to linear scaling properties of the number of nonzero two-electron integrals and the number of leading matrix elements of density matrix. This property is reinforced by employing the density prescreening technique. The use of the density difference prescreening further improves the linear scaling property of the Fock matrix calculation method. As a result, the linear scaling regime of the Fock matrix calculation can begin from the number of basis functions of 2000–3000 in dependence on the basis function type in molecular calculations. It was also shown that the conventional algorithm of Fock matrix calculation from stored nonzero two-electron integrals with density prescreening possesses linear scaling property.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exact restoration of Galilei invariance in density functional calculations with quantum Monte Carlo

We investigate some aspects of the connection between mean-field and ab-initio calculations for any-nucleon systems employing the Gogny effective interaction. In particular, we present variational Monte Carlo calculations of 4 He and 16 O, for which we extended the formalism of the linear method to the case of a density-dependent Hamiltonian. Monte Carlo calculations using an uncorrelated basis reduce to Hartree-Fock ones, but Galilean invariance can be preserved, contrary to the usual treatment. An analysis of the results obtained with the Gogny force when used in conjunction with correlated wave functions has also been performed. Here, the calculations show the collapse of the deuteron, leading to a set of unphysical predictions for the structure of heavier nuclei. This behavior remarks the different role of the Gogny effective interaction as compared to bare interactions typically used in fully microscopic calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast calculation of diffraction patterns from an ensemble of aligned molecules

We report an algorithm to calculate electron diffraction patterns for molecules with anisotropic angular distribution, which is significantly faster than existing methods. The algorithm uses a transform to convert the molecular orientation distribution, which is a function of three Euler angles, to the atom-pair distribution functions which depend on the polar and azimuthal angles. The diffraction signal can then be calculated from the atom-pair distributions. We demonstrate the computation method numerically by calculating electron diffraction patterns for a symmetric top molecule (trifluoroiodomethane) and an asymmetric top molecule (formaldehyde) and show that it reduces the calculation time by approximately two orders of magnitude compared to the standard brute-force method. Here, the method can also be applied to the calculation of x-ray diffraction patterns.

74 ATOMIC AND MOLECULAR PHYSICS↗

Discrete beta dose kernel matrices for nuclides applied in targeted radionuclide therapy (TRT) calculated with MCNP5

Purpose: Radiopharmaceuticals administered in targeted radionuclide therapy (TRT) rely to a great extent not only on beta-emitting nuclides but also on emitters of monoenergetic electrons. Recent advances like combined PET/CT devices, the consequential coregistration of both data, the concept of using beta couples for diagnosis and therapy, respectively, as well as the development of voxel models offer a great potential for developing TRT dose calculation systems similar to those available for external beam treatment planning. The deterministic algorithms in question for this task are based on the convolution of three-dimensional matrices, one representing the activity distribution and the other the dose point kernel. This study aims to report on three-dimensional kernel matrices for various nuclides used in TRT. Methods: The Monte Carlo code MCNP5 was used to calculate discrete dose kernels of beta particles including the contributions from their respective secondary radiation in soft tissue for the following nuclides: {sup 32}P, {sup 33}P, {sup 67}Cu, {sup 89}Sr, {sup 90}Y, {sup 103}Rh{sup m}, {sup 131}I, {sup 177}Lu, {sup 186}Re, and {sup 188}Re. For each nuclide a kernel cube of 10x10x10 mm{sup 3} was calculated, the dimensions of a voxel being 1 mm{sup 3}. Additional kernels with voxel sizes of 3x3x3 mm{sup 3} were simulated. Results: Comparison with the S-value data regarding {sup 32}P, {sup 89}Sr, {sup 90}Y, and {sup 131}I of the MIRD committee which were calculated with the EGS4 code showed a very good agreement, the secondary particle transport of {sup 90}Y being the only exception. Documented analytical kernels on the other side show deviations very close and very far to the source. Conclusions: The good accordance with the only discrete dose kernels published up to date justifies the method chosen. Together with the additional six nuclides, this report provides a considerable database for three-dimensional kernel matrices with regard to beta radionuclides applied in TRT. In contrast to analytical dose point kernels, the discrete kernels elude the problem of overestimation near the source and take energy depositions into account, which occur beyond the range of the continuous-slowing-down approximation (csda range). Recalculation of the 1x1x1 mm{sup 3} kernels to other dose kernels with varying voxel dimensions, cubic or noncubic, is shown to be easily manageable and thereby provides a resolution-independent system of dose calculation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-67: Clinical Implementation and Evaluation of the Acuros Dose Calculation Algorithm

Purpose: The main aim of the current study is to present a detailed description of the implementation of the Acuros XB Dose Calculation Algorithm, and subsequently evaluate its clinical impacts by comparing it with AAA algorithm. Methods: The source models for both Acuros XB and AAA were configured by importing the same measured beam data into Eclipse treatment planning system. Both algorithms were evaluated by comparing calculated dose with measured dose on a homogeneous water phantom for field sizes ranging from 6cm × 6cm to 40cm × 40cm. Central axis and off-axis points with different depths were chosen for the comparison. Similarly, wedge fields with wedge angles from 15 to 60 degree were used. In addition, variable field sizes for a heterogeneous phantom were used to evaluate the Acuros algorithm. Finally, both Acuros and AAA were tested on VMAT patient plans for various sites. Does distributions and calculation time were compared. Results: On average, computation time is reduced by at least 50% by Acuros XB compared with AAA on single fields and VMAT plans. When used for open 6MV photon beams on homogeneous water phantom, both Acuros XB and AAA calculated doses were within 1% of measurement. For 23 MV photon beams, the calculated doses were within 1.5% of measured doses for Acuros XB and 2% for AAA. When heterogeneous phantom was used, Acuros XB also improved on accuracy. Conclusion: Compared with AAA, Acuros XB can improve accuracy while significantly reduce computation time for VMAT plans.

60 APPLIED LIFE SCIENCES↗

SU-C-BRF-04: Delivered 4D Dose Calculation for Lung-VMAT Patients Using In- Treatment CBCT and LINAC Log Data

Purpose: To verify the delivered four-dimensional (4D) dose distribution for the lung VMAT using in-treatment 4D cone-beam CT (CBCT) and LINAC log data. Methods: Three patients for lung stereotactic radiotherapy (SRT) were treated by single-arc volumetric modulated arc therapy (VMAT) created by SmartArc in Pinnacle v9.2 (Philips, USA).Kilovoltage (kV) projection images were acquired during VMAT delivery using the x-ray volumetric imager, XVI (Elekta, UK). LINAC log data were also recorded via iCom interface (Elekta, UK). Subsequently, the iCom data format was converted to Pinnacle data format, thereby allowing Pinnacle to read actual MLC positions, jaw positions, gantry angles and MUs. These parameters were categorized into four groups according to patient's respiratory phase. The patient respiratory phase was determined from kV-projection images by in-house phase recognizing software. By exporting these data back to Pinnacle, in-treatment dose distributions for each respiratory phase were obtained by combining calculated dose having a particular phase. The 4D CBCT were reconstructed by in-house program. The density in the structures on the CBCT was overridden by the average density in the corresponding structures on the planning CT for the dose calculation. The dose indexes, such as maximum, minimum, mean dose in the target were compared among the plan, in-treatment 3D calculation, and in-treatment 4D calculation. Results: The day-to-day variation of the delivered dose was observed for all three patients. The maximum difference was 5.9% for the minimum dose in the target. Difference for the mean dose was found to be small (1.1% at maximum). Conclusion: We have obtained in-treatment dose distribution for each of the different respiratory phases using in-treatment 4D CBCT and LINAC log data during lung VMAT delivery. Our result indicate a small but significant dose difference between the 3D and 4D calculations for the case of large target traveling.

60 APPLIED LIFE SCIENCES↗

SU-E-T-37: A GPU-Based Pencil Beam Algorithm for Dose Calculations in Proton Radiation Therapy

Purpose: Recent developments in radiation therapy have been focused on applications of charged particles, especially protons. Over the years several dose calculation methods have been proposed in proton therapy. A common characteristic of all these methods is their extensive computational burden. In the current study we present for the first time, to our best knowledge, a GPU-based PBA for proton dose calculations in Matlab. Methods: In the current study we employed an analytical expression for the protons depth dose distribution. The central-axis term is taken from the broad-beam central-axis depth dose in water modified by an inverse square correction while the distribution of the off-axis term was considered Gaussian. The serial code was implemented in MATLAB and was launched on a desktop with a quad core Intel Xeon X5550 at 2.67GHz with 8 GB of RAM. For the parallelization on the GPU, the parallel computing toolbox was employed and the code was launched on a GTX 770 with Kepler architecture. The performance comparison was established on the speedup factors. Results: The performance of the GPU code was evaluated for three different energies: low (50 MeV), medium (100 MeV) and high (150 MeV). Four square fields were selected for each energy, and the dose calculations were performed with both the serial and parallel codes for a homogeneous water phantom with size 300×300×300 mm3. The resolution of the PBs was set to 1.0 mm. The maximum speedup of ∼127 was achieved for the highest energy and the largest field size. Conclusion: A GPU-based PB algorithm for proton dose calculations in Matlab was presented. A maximum speedup of ∼127 was achieved. Future directions of the current work include extension of our method for dose calculation in heterogeneous phantoms.

60 APPLIED LIFE SCIENCES↗

SU-F-T-148: Are the Approximations in Analytic Semi-Empirical Dose Calculation Algorithms for Intensity Modulated Proton Therapy for Complex Heterogeneities of Head and Neck Clinically Significant?

Purpose: Evaluate the differences in dose distributions between the proton analytic semi-empirical dose calculation algorithm used in the clinic and Monte Carlo calculations for a sample of 50 head-and-neck (H&N) patients and estimate the potential clinical significance of the differences. Methods: A cohort of 50 H&N patients, treated at the University of Texas Cancer Center with Intensity Modulated Proton Therapy (IMPT), were selected for evaluation of clinical significance of approximations in computed dose distributions. H&N site was selected because of the highly inhomogeneous nature of the anatomy. The Fast Dose Calculator (FDC), a fast track-repeating accelerated Monte Carlo algorithm for proton therapy, was utilized for the calculation of dose distributions delivered during treatment plans. Because of its short processing time, FDC allows for the processing of large cohorts of patients. FDC has been validated versus GEANT4, a full Monte Carlo system and measurements in water and for inhomogeneous phantoms. A gamma-index analysis, DVHs, EUDs, and TCP and NTCPs computed using published models were utilized to evaluate the differences between the Treatment Plan System (TPS) and FDC. Results: The Monte Carlo results systematically predict lower dose delivered in the target. The observed differences can be as large as 8 Gy, and should have a clinical impact. Gamma analysis also showed significant differences between both approaches, especially for the target volumes. Conclusion: Monte Carlo calculations with fast algorithms is practical and should be considered for the clinic, at least as a treatment plan verification tool.

60 APPLIED LIFE SCIENCES↗

Poster - 08: Preliminary Investigation into Collapsed-Cone based Dose Calculations for COMS Eye Plaques

Purpose: To investigate the accuracy of model-based dose calculations using a collapsed-cone algorithm for COMS eye plaques loaded with I-125 seeds. Methods: The Nucletron SelectSeed 130.002 I-125 seed and the 12 mm COMS eye plaque were incorporated into a research version of the Oncentra® Brachy v4.5 treatment planning system which uses the Advanced Collapsed-cone Engine (ACE) algorithm. Comparisons of TG-43 and high-accuracy ACE doses were performed for a single seed in a 30×30×30 cm{sup 3} water box, as well as with one seed in the central slot of the 12 mm COMS eye plaque. The doses along the plaque central axis (CAX) were used to calculate the carrier correction factor, T(r), and were compared to tabulated and MCNP6 simulated doses for both the SelectSeed and IsoAid IAI-125A seeds. Results: The ACE calculated dose for the single seed in water was on average within 0.62 ± 2.2% of the TG-43 dose, with the largest differences occurring near the end-welds. The ratio of ACE to TG-43 calculated doses along the CAX (T(r)) of the 12 mm COMS plaque for the SelectSeed was on average within 3.0% of previously tabulated data, and within 2.9% of the MCNP6 simulated values. The IsoAid and SelectSeed T(r) values agreed within 0.3%. Conclusions: Initial comparisons show good agreement between ACE and MC doses for a single seed in a 12 mm COMS eye plaque; more complicated scenarios are being investigated to determine the accuracy of this calculation method.

60 APPLIED LIFE SCIENCES↗

MCNP5 Calculations Replicating ARH-600 Nitrate Data

This report serves to extend the previous document: "MCNP Calculations Replicating ARH-600 Data" by replicating the nitrate curves found in ARH-600. This report includes the MCNP models used, the calculated critical dimension for each analyzed parameter set, and the resulting data libraries for use with the CritView code. As with the ARH-600 data, this report is not meant to replace the analysis of the fissile systems by qualified criticality personnel. The MCNP data is presented without accounting for the statistical uncertainty (although this is typically less than 0.001) or bias and, as such, the application of a reasonable safety margin is required. The data that follows pertains to the uranyl nitrate and plutonium nitrate spheres, infinite cylinders, and infinite slabs of varying isotopic composition, reflector thickness, and molarity. Each of the cases was modeled in MCNP (version 5.1.40), using the ENDF/B-VI cross section set. Given a molarity, isotopic composition, and reflector thickness, the fissile concentration and diameter (or thicknesses in the case of the slab geometries) were varied. The diameter for which k-effective equals 1.00 for a given concentration could then be calculated and graphed. These graphs are included in this report. The pages that follow describe the regions modeled, formulas for calculating the various parameters, a list of cross-sections used in the calculations, a description of the automation routine and data, and finally the data output. The data of most interest are the critical dimensions of the various systems analyzed. This is presented graphically, and in table format, in Appendix B. Appendix C provides a text listing of the same data in a format that is compatible with the CritView code. Appendices D and E provide listing of example Template files and MCNP input files (these are discussed further in Section 4). Appendix F is a complete listing of all of the output data (i.e., all of the analyzed dimensions and the resulting k eff values).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Real-time POD-CFD Wind-Load Calculator for PV Systems

The primary objective of this project is to create an accurate web-based real-time wind-load calculator. This is of paramount importance for (1) the rapid and accurate assessments of the uplift and downforce loads on a PV mounting system, (2) identifying viable solutions from available mounting systems, and therefore helping reduce the cost of mounting hardware and installation. Wind loading calculations for structures are currently performed according to the American Society of Civil Engineers/ Structural Engineering Institute Standard ASCE/SEI 7; the values in this standard were calculated from simplified models that do not necessarily take into account relevant characteristics such as those from full 3D effects, end effects, turbulence generation and dissipation, as well as minor effects derived from shear forces on installation brackets and other accessories. This standard does not include provisions that address the special requirements of rooftop PV systems, and attempts to apply this standard may lead to significant design errors as wind loads are incorrectly estimated. Therefore, an accurate calculator would be of paramount importance for the preliminary assessments of the uplift and downforce loads on a PV mounting system, identifying viable solutions from available mounting systems, and therefore helping reduce the cost of the mounting system and installation. The challenge is that although a full-fledged three-dimensional computational fluid dynamics (CFD) analysis would properly and accurately capture the complete physical effects of air flow over PV systems, it would be impractical for this tool, which is intended to be a real-time web-based calculator. CFD routinely requires enormous computation times to arrive at solutions that can be deemed accurate and grid-independent even in powerful and massively parallel computer platforms.

14 SOLAR ENERGY↗

Evaluation of the NSUF Reactor Activation and Damage (RAD) Calculator damage component

The Nuclear Science User Facilities (NSUF) provide researchers access to nuclear research facilities and expertise all over the United States and at the Belgian Center for Nuclear Research (SCK/CEN). One special capability of the NSUF is providing access to nuclear research and test reactors often used for conducting material testing experiments. These services are provided at no cost to the researcher through a competitive, peer-reviewed process. With so many proposals being submitted simultaneously, an NSUF information management resource called the Combined Materials Experiment Toolkit (CoMET) was implemented to speed up the review process and give users access to the information and tools necessary for designing meaningful experiments and writing the best proposals possible. One of CoMET’s tools is the Reactor Activation and Damage (RAD) Calculator. For those with little or no background in it, neutron irradiation in research and test reactors can be a challenging subject to include in a proposal. That is why the RAD Calculator was created to assist users with providing estimates of irradiation and post-irradiation conditions, enabling them to select the best neutron irradiation and post-irradiation examination facilities for reaching their experiment goals. The RAD Calculator is a general scoping tool that estimates radiation damage in terms of DPA, in addition to the resulting radioactivity of the material post-irradiation. This report evaluates the neutron damage component of the RAD Calculator. The evaluation of the activation component of the calculator is covered in report INL/EXT-20-58080.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗