Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Results from Laboratory and Field Study of Thin Triple Pane Windows

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak cooling load of a home. In recent years, improvements in glass manufacturing have enabled the use of a very thin central pane of glass similar to a cell phone screen to produce a thin triple-pane window, for finished insulated glass units (IGUs) with an overall thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy sponsored laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. Thin triple pane windows were evaluated at the PNNL Lab Homes, a matched pair of manufactured houses located on PNNL’s campus in Richland, Washington and also at 16 different field study sites around the country. The experimental results include a comparison of heating, ventilation, and air-conditioning (HVAC) energy usage, condensation potential, occupant comfort, sound infiltration, and thermal performance. Field study data will be gathered through June of 2022; preliminary results are being shared in this paper. The lab houses are identical except that the reference house had standard double pane windows with assembly U-0.66 and the test house had thin triple pane windows with assembly U-0.19. Across the experimental test days, the daily HVAC savings ranged from 0.2 to 18.7 kWh (3%–18%) for the heating season and from 2.5 to 8.0 kWh (23%–41%) for the cooling season. The higher thermal performance of the thin triple-pane windows also reduced the condensation potential on the interior surface during winter months and provided more even distribution of temperatures throughout the home in comparison to the baseline. In addition to the added thermal performance, the thin triple-pane windows demonstrated significant acoustic benefits, reducing sound infiltration by 8 dB to 10 dB. For the field test portion of the project thin triple pane insulated glass units were produced by two different manufacturers, and then installed without modification into the ½” IGU pockets of the standard double pane frames of four other manufacturers. Field tests performed on existing homes in Washington, Montana, Colorado, and New York compared thin triple pane retrofits to original window conditions (before and after). Field tests at new construction sites in Minnesota, Michigan, and New York compared thin triple pane windows to commercially available solutions such as double pane or traditional triple pane (with a standard-thickness center pane). Field test work is ongoing, but preliminary results appear to follow the sound, surface temperature, and energy improvement results from the Lab Homes comparison. Additionally, reports from builders and installers indicate that thin triples require almost no added time or effort to install and look nearly identical to other windows, indicating the possibility of offering next-level performance with a product that requires very little modification to current production or installation practices, long considered a major barrier to technology uptake in the construction market.

energy efficiency, home retrofit, Windows, window ↗

Progressive Fracture of Fiber Composite Build-Up Structures

Damage progression and fracture of built-up composite structures is evaluated by using computational simulation. The objective is to examine the behavior and response of a stiffened composite (0/ +/- 45/90)(sub s6) laminate panel by simulating the damage initiation, growth, accumulation, progression and propagation to structural collapse. An integrated computer code, CODSTRAN, was augmented for the simulation of the progressive damage and fracture of built-up composite structures under mechanical loading. Results show that damage initiation and progression have significant effect on the structural response. Influence of the type of loading is investigated on the damage initiation, propagation and final fracture of the build-up composite panel.

Gotsis, Pascal K.↗

Progressive Fracture of Fiber Composite Build-Up Structures

Damage progression and fracture of built-up composite structures is evaluated by using computational simulation. The objective is to examine the behavior and response of a stiffened composite (0 +/-45/90)(sub s6) laminate panel by simulating the damage initiation, growth, accumulation, progression and propagation to structural collapse. An integrated computer code CODSTRAN was augmented for the simulation of the progressive damage and fracture of built-up composite structures under mechanical loading. Results show that damage initiation and progression to have significant effect on the structural response. Influence of the type of loading is investigated on the damage initiation, propagation and final fracture of the build-up composite panel.

Minnetyan, Levon↗

Grid-connected heat pump water heater benefits for low-income households in the Southeastern United States

Energy efficient heat pump water heaters (HPWHs) reduce customer energy costs; grid-connected controls further increase HPWH value by enabling energy storage and shifting demand to cheaper, off-peak periods. However, a HPWH’s first cost premium can put it out of reach for low-income customers. This paper will present results of an ongoing study exploring the benefits of load shifting HPWHs for 24 low-income households, aiming to support increased product deployment in this demographic. The study uses EcoPort modules to shift HPWH load for a study sample consisting primarily of low-income adults and seniors in North Carolina. Building upon prior studies, the study’s HPWH operating schedules are designed to maximize shifted energy and minimize participant electricity costs based on local time-of-use rates. The study documents load profiles of grid-connected HPWHs in a less-studied demographic group and explores how certain groups may have particularly flexible loads due to their unique usage profiles. The results are relevant for HPWH product performance in the Southeast. The study will quantify HPWH load shifting performance during North Carolina’s hot summer, temperate shoulder, and occasionally sub-freezing winter seasons, and the study includes installations in conditioned, semi-conditioned, and unconditioned spaces. Finally, study results will also explore how controlled HPWHs can provide value to the regional grid by reducing seasonal peaks via demand response. Lessons learned include HPWH acceptance for low-income and senior users, best practices for maintaining HPWH connectivity among users without prior product experience, and strategies to leverage remote monitoring to ensure optimal operation and enhance HPWH reliability.

Urigwe, Daniela↗

Gateway Cities Unplugged: (em)Powering Affordable Housing (Final Technical Report)

The Gateway Cities Unplugged: (em)Powering Affordable Housing (the “Project”) was launched to address a critical challenge in the U.S. building and energy sectors: enabling multifamily buildings especially those serving low and moderate‑income (LMI) communities to actively support grid modernization through Grid‑Interactive Efficient Buildings (GEB). Multifamily housing represents a large share of national building energy consumption, yet the sector faces persistent barriers to adopting advanced load flexibility technologies, including capital constraints, aging infrastructure, and limited access to demand‑side management tools. This Project sought to overcome those barriers by defining, evaluating, and designing commercially viable GEB technology packages for six representative multifamily properties across Massachusetts, Connecticut, and New York.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental demonstration and performance evaluation of a complex fenestration system for daylighting and thermal harvesting

Two significant design strategies for mitigating building energy consumption are daylight redirection and solar energy harvesting. Effective daylighting implementation enhances the amount of useful natural light within a space and offsets the need for electric lighting. Solar energy harvesting systems can mitigate energy costs from mechanical systems by managing incoming thermal loads or capturing solar energy that can be used to supplement thermal systems in the building. While there are many available façade-based technologies that can perform daylighting or solar thermal energy harvesting, there remains a limitation in available systems that can perform both of them simultaneously. This paper, describes the design and experimental demonstration of a Liquid Filled Prismatic Louver (LFPL) system, which combines both energy-saving strategies. The LFPL system was installed in a south-facing room in New York City and evaluated for indoor daylight penetration and potential for thermal energy harvesting. Daylight redirection is achieved through the prismatic louver geometry and proper orientation, whereas thermal energy harvesting is achieved through IR absorption from the liquid (e.g., water) within the prisms. Daylighting performance was evaluated by illuminance measurements at key locations within the space, whereas thermal harvesting performance was evaluated through temperature measurements and thermal imaging analysis. We show that the LFPL system, with all prismatic elements oriented at the same angle, achieve a 2-fold and 8-fold enhancement in daylight redirection to the ceiling, for prism orientations of 10° and 20°, respectively. We also demonstrate the system’s capability to adjust to specific lighting needs, within the space, through the dynamic individual orientation of prismatic elements; thus, achieving a concentrated ceiling illuminance enhancement of ~100 times and ~200 times at 2.5 and 4.3 m away from the window sill, providing workplane illuminance enhancement of 6 and 2 times more than in the case of the control room with regular windows. Furthermore, we illustrate a reduction of potential heating loads at locations close to the window from the combination of infrared absorption in the water volume and the redirection of the incoming solar radiation, leading to a reduction of the workplane temperature by an average of 7–10 °C.

14 SOLAR ENERGY↗

Multi-Agent Reinforcement Learning for Distribution System Critical Load Restoration: Preprint

Grid resilience has become a critical topic recently because of the increasing occurrence of extreme events and the growing integration of intermittent renewable energy sources. To build a resilient distribution system, this paper develops a multi-agent reinforcement learning-based (MARL) method to coordinate distribution energy resources (DERs) dispatch, load pickup, and network reconfiguration for load restoration after a system outage. With the help of two types of control agents, namely critical load restoration (CLR) and coordination (COR) agents, system loads can be restored efficiently, given available resources. The effectiveness and superiority of the proposed algorithm are demonstrated through simulations and comparative studies on a real distribution feeder in Western Colorado.

distribution system↗

Concorde noise-induced building vibrations: International Airport Dulles

A series of studies were conducted to assess the noise-induced building vibrations associated with Concorde operations. The vibration levels of windows, walls, and floors were measured along with the associated noise levels of Concorde, subsonic aircraft and some nonaircraft events. Test sites included Sully Plantation which is adjacent to Dulles International Airport and three residential homes located in Montgomery County, Maryland. The measured vibration response levels due to Concorde operations were found to be: (1) higher than the levels due to other aircraft, (2) less than the levels due to certain household events which involve direct impulsive loading such as door and window closing, (3) less than criteria levels for building damage, and (4) comparable to levels which are perceptible to people.

Mayes, W. H.↗

Managing Army Plug Load Equipment Energy Use: Office Equipment

Office equipment covers a large and diverse group of plug load devices. Policies focused on equipment purchase, power management, and usage limitations can save the Army more than 10 million kWh and $620K per year within just four building categories. This represents a top opportunity for energy- and cost-savings identified by a recent Army plug load study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vectorization of CMSSW offline software

The CMS experiment has been utilizing vectorization, or SIMD, in parts of its data processing applications for over a decade. On x86 platforms the vectorization level is still SSE3. In the past attempts to use wider vector instruction sets such as AVX or AVX-512 have, in practice, not resulted in improvements in the overall event processing throughput, because the CPUs scale down their frequency when processing AVX instructions. In addition, a notable part of the global pool of CMS’ resources has been old systems either not supporting AVX, or where the CPU frequency downscaling impacts all cores of the CPU. CMS has nevertheless continued to vectorize more of its application code, and in this work we review profiling methods we have found effective to find out pieces of code that would benefit from vectorization, and techniques to transform those codes such that the GCC compiler is able to auto-vectorize those codes. The build system used for CMSSW, Scram, has also been enha nced to be able to build code for multiple CPU microarchitectures such that the shared libraries of desired microarchitecture level can be loaded based on the CPU of the system. This multi-microarchitecture setup is invisible to the workflow management system, which makes its deployment straightforward. We describe in detail how this multi-microarchitecture build is set up, and measure the impact of using wider vector units than SSE3 on the event processing throughput of CMS applications such as simulation and reconstruction on recent x86 CPUs.

Gartung, Patrick↗

Alfalfa

Alfalfa-based testbeds enable building equipment, control products, and workforce development tools to interact with dynamic building simulations representing the desired building, system, weather, and grid configuration. Alfalfa is used to de-risk implementation of load flexibility prior to field deployment, reducing the costs and timelines associated with adoption of decarbonization technology at the grid edge.

building energy modeling↗

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. A lookup table was created using GHEDesigner to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on energy bills for building owners (agents). This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of future cost and price scenarios. Initial results for statewide analysis (for Vermont) and nationwide (for United States) are provided. Future work includes expanding the module to consider mixed residential and commercial districts as well as evaluating multiple cost scenarios.

ambient-temperature loop↗

Advances in the Co-Simulation of Detailed Electrical and Whole-Building Energy Performance

This article describes recent co-simulation advances for the simultaneous modeling of detailed building electrical distribution systems and whole-building energy performance. The co-simulation architecture combines the EnergyPlus® engine for whole-building energy modeling with a new Modelica library for building an electrical distribution system model that is based on harmonic power flow. This new library allows for a higher-fidelity modeling of electrical power flows and losses within buildings than is available with current building electrical modeling software. We demonstrate the feasibility of the architecture by modeling a simple, two-zone thermal chamber with internal power electronics converters and resistive loads, and we validate the model using experimental data. The proposed co-simulation capability significantly expands the capabilities of building electrical distribution system models in the context of whole-building energy modeling, thus enabling more complex analyses than would have been possible with individual building performance simulation tools that are used to date.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation into the instantaneous centre of rotation for enhanced design of floating offshore wind turbines

The dynamic behaviour of floating offshore wind turbines (FOWTs) involves complex interactions of multivariate loads from wind, waves, and currents, which result in complex motion characteristics. Although methods for analysing global motion responses are well-established, the time- and location-dependent kinematics remain underexplored. This paper investigates the instantaneous centre of rotation (ICR), a point of zero velocity at a time instance of general plane motion. Understanding and strategically positioning the ICR can reduce the dynamic motion in critical structural locations, enhancing the performance and structural robustness of FOWTs. The paper presents a method for computing the ICR using time-domain simulation results and proposes a statistical analysis approach suitable for design studies. Building on prior research, it examines the sensitivity of the ICR to external loading and design features, providing insights into how these factors influence motion response and how the motion response influences the statistics of the ICR, structural loads, and other performance metrics of interest. The study explores two FOWT configurations, a spar and a semisubmersible, identifying design variables that most effectively control the ICR statistics and identifying the ICR statistics most correlated with the responses of interest. Finally, through two case studies, we demonstrate how to apply these new insights in a practical design scenario. By adjusting the design variables most correlated with the ICR (fairlead vertical position and centre of mass for the spar and mooring line length and offset column diameter for the semisubmersible), we successfully modified the designs of the floating support structures to reduce the loads in the mooring lines, tower base, and blade roots, improving the ultimate strength and fatigue characteristics compared to the original designs.

17 WIND ENERGY↗

Grid Planning for Building Electrification: A Report by the Energy Systems Integration Group’s Grid Planning for Building Electrification Task Force

The increased electrification of buildings across the United States is being driven by technical advancements, cost reductions for some building technologies, consumer preferences, and policy goals for decarbonization. However, the effects of this load growth on the electric distribution system are often only a minor consideration in policymaking and long-term planning studies. The long lead time and useful life of power system equipment means that the decisions taken today are expected to support our society well into the 2060s and beyond. Distribution planning stakeholders can take steps today to establish a grid foundation that captures the new challenges presented by building electrification. This report focuses on building electrification for the residential and commercial sectors, focusing most heavily on space heating, as this end use stands to most strongly impact demand.1 Across all end uses, building electrification could require somewhere between 10% and 70% more electricity generation capacity than exists today depending on technology adoption and energy efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Software for Building Models of 3D Objects via the Internet

The Virtual EDF Builder (where EDF signifies Electronic Development Fixture) is a computer program that facilitates the use of the Internet for building and displaying digital models of three-dimensional (3D) objects that ordinarily comprise assemblies of solid models created previously by use of computer-aided-design (CAD) programs. The Virtual EDF Builder resides on a Unix-based server computer. It is used in conjunction with a commercially available Web-based plug-in viewer program that runs on a client computer. The Virtual EDF Builder acts as a translator between the viewer program and a database stored on the server. The translation function includes the provision of uniform resource locator (URL) links to other Web-based computer systems and databases. The Virtual EDF builder can be used in two ways: (1) If the client computer is Unix-based, then it can assemble a model locally; the computational load is transferred from the server to the client computer. (2) Alternatively, the server can be made to build the model, in which case the server bears the computational load and the results are downloaded to the client computer or workstation upon completion.

Schramer, Tim↗

Computational analysis of high resolution unsteady airloads for rotor aeroacoustics

The study of helicopter aerodynamic loading for acoustics applications requires the application of efficient yet accurate simulations of the velocity field induced by the rotor's vortex wake. This report summarizes work to date on the development of such an analysis, which builds on the Constant Vorticity Contour (CVC) free wake model, previously implemented for the study of vibratory loading in the RotorCRAFT computer code. The present effort has focused on implementation of an airload reconstruction approach that computes high resolution airload solutions of rotor/rotor-wake interactions required for acoustics computations. Supplementary efforts on the development of improved vortex core modeling, unsteady aerodynamic effects, higher spatial resolution of rotor loading, and fast vortex wake implementations have substantially enhanced the capabilities of the resulting software, denoted RotorCRAFT/AA (AeroAcoustics). Results of validation calculations using recently acquired model rotor data show that by employing airload reconstruction it is possible to apply the CVC wake analysis with temporal and spatial resolution suitable for acoustics applications while reducing the computation time required by one to two orders of magnitude relative to that required by direct calculations. Promising correlation with this body of airload and noise data has been obtained for a variety of rotor configurations and operating conditions.

Quackenbush, Todd R.↗