Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

ASCR@40

One page flyers on: A Revolution in Modeling and Simulation; Applying Equations to Complex Problems; Uncertainty Quantification; Moving Big Data; Grid Computing for High-Speed Collaboration; Making Sense of Big Data; Overcoming Scaling Challenges; Building Better Computers; World-Leading Computing Facilities; Supporting Science Through Open-Source Software; and Building the Computational Workforce. Content provided by Department of Energy multiprogram laboratory researchers. Prepared by the Krell Institute for the ASCAC Subcommittee on the 40-year History of ASCR.

97 MATHEMATICS AND COMPUTING↗

U.S.-China Clean Energy Research Center Building Energy Efficiency (CERC-BEE) Open-Source Retrofit Targeting Tool (CRADA FP00007338 Final Report)

To increase the cost-saving energy and carbon dioxide (CO 2 ) emissions reductions in buildings and portfolios at the scale and speed necessary to limit climate change, researchers at LBNL and Johnson Controls (JCI) developed the Building Efficiency Targeting Tool for Energy Retrofits (BETTER). BETTER is a software tool that consists of three components: (1) the BETTER analytical engine source code (which was developed with intellectual property provided by JCI under CRADA FP00007338); (2) the BETTER web application, developed by LBNL and McQuillen Interactive Pty. Ltd; and (3) the BETTER application programming interface (API), also developed by LBNL and McQuillen Interactive Pty. Ltd. BETTER enables building and portfolio owners, managers, and service providers worldwide to quickly, easily identify cost-saving energy efficiency retrofits in existing buildings and portfolios without expensive site visits or complex modeling. With minimal data input, the tool benchmarks a building’s electric and fossil energy usage against peers; quantifies energy, cost and greenhouse gas (GHG) emission reduction potentials at the building and portfolio levels; and recommends energy efficiency measures to decarbonize and electrify buildings and portfolios, targeting specific energy savings levels. No other tool so comprehensively analyzes buildings and portfolios with such ease. If fully implemented, it is estimated that BETTER could help reduce emissions equivalent to planting 1.3 billion trees globally by 2030. Moreover, an additional 50-75% of embodied GHG emissions could be avoided in each case where BETTER results in a building being retrofitted instead of demolished and replaced, providing substantial additional decarbonization benefits for the buildings sector. BETTER has garnered multiple awards and avid interest from investors. In 2020, it earned a R&D 100 Award for innovation and a LBNL Director’s Award for Technology Transfer. In 2021, BETTER was named an EarthX E-Capital Summit Climate Tech Prize semi-finalist

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Summary Report for Soil and Slab Sampling at Former Building 175

Lawrence Livermore National Security (LLNS) and the U.S. Department of Energy (DOE) are in the process of returning the area where Building 175 existed to beneficial use for future site development. The completed assessment will help LLNS and DOE to outline project scope and costs associated with the removal, characterization, and disposal of materials generated when the concrete slab for the former building and any associated remaining subsurface structures are demolished. Slab removal under the Transition & Disposition process requires full screening for potential site contamination to determine appropriate future land use. Borehole locations and depths were designed to correctly assess DOE’s future liability for characterizing residual vadose zone contamination. If a residual source area is identified at depth, DOE will need to evaluate the additional cost of future subsurface cleanup (with limited access) due to planned development. This is necessary to leave the location in a “ready-to-build” status. As a result, Phase II sampling requirements may in some cases extend beyond the construction zone required for slab removal to ensure the necessary due diligence. To avoid the potential spread of contamination and/or the creation of an environmental release by impacting the integrity of known contamination areas (e.g., pit within room 102 and the east to west boundary seam), these locations were not sampled for this project. During demolition of the slab, these locations and their underlying soils should be further evaluated. The assessment was conducted in accord with the May 2022 Lawrence Livermore National Laboratory Former Building 175 Assessment Soil Sampling and Analysis Plan / Quality Assurance Plan. Thirty-six, direct-push borings were advanced, along with collecting concrete (where present) and soil samples for laboratory analyses. Thirty-two of the borings were advanced to a depth of 25 feet below ground (bgs), and four borings were advanced to a depth of 55 feet bgs. The concrete slab for former Building 175 ranged from approximately 8 inches to over two feet in thickness. Soils encountered during the investigation consisted primarily of clayey silt, with interbeds of sandy gravel and silty sand to the total depth explored of 55 feet bgs. Field photoionization detector readings – checking for volatile organic compound (VOC) vapors in soils, ranged from zero (0) to a peak of 33 parts per million at 25 feet bgs in boring PC-B175- 028. The cause for the peak reading is unknown, however, no visually discolored or odorous soils were encountered during the assessment and all VOC results were below Lawrence Livermore National Laboratory’s (LLNL’s) Soil Screening and Management Plan (SSMP) soil screening levels (SSL). Groundwater was not encountered during the assessment and is expected to occur at roughly 65 feet bgs in the project area. No metals were detected at concentrations of concern in the concrete core samples collected and analyzed. Low gross alpha and beta activity concentrations were detected in the concrete core samples collected and analyzed. The detected activity concentrations would appear to be from naturally occurring radioactive isotopes, i.e., potassium 40, present in the raw materials used to make concrete and not artificially added. Tritium was not detected above the testing laboratory's Method Detection Limit (MDL) in any of the concrete core samples collected and analyzed. The radioactive isotopes - actinium 228, bismuth 214, lead 212, lead 214, potassium 40, radium 226, radium 228, and thallium 208, were detected at low activity concentrations in the concrete core samples analyzed. Based on the detected activity concentrations, the isotopes would appear to be naturally occurring in the raw materials used to make concrete and not artificially added. Acetone – a common laboratory contaminant, was detected in nine of the soil samples collected and analyzed. Concentrations of two other volatile organic compounds (benzene and tetrachloroethene) were detected in five of the soil samples analyzed. All concentrations were below SSLs. Total petroleum hydrocarbons as diesel range organics were detected at 43.9 milligrams per kilogram (mg/kg) in the 20-foot bgs duplicate sample from boring PC-B175-007. Total petroleum hydrocarbons as motor oil were detected at 7.20 mg/kg in the 15-foot bgs routine sample from boring PC-B175-001, and at 20.7 mg/kg in the 20-foot bgs duplicate sample from boring PC-B175-007. The SSL for diesel-range TPHs is 260 mg/kg. LLNL does not have an SSL for motor oil range TPHs. No indications of a release, e.g., visibly stained, or odorous soil, were present at the boring locations. No samples collected contained polychlorinated biphenyls (PCBs) in concentrations above the laboratory reporting limit. Arsenic was detected above its SSL of 8.51 mg/kg in the 25-foot bgs routine sample collected from boring PC-B175-023. Nickel was detected above its SSL of 86.0 mg/kg in the 10-foot bgs routine sample from boing PC-B175-005, the 20-foot bgs routine sample from boring PC-B175-025, and the 25-foot bgs routine sample from boring PC-B175-034. The detected concentrations, however, were well below ten times (10x) their respective STLCs. Gross alpha and/or gross beta were detected above their respective SSL activity concentrations in three routine soil samples. Retesting (two per sample) of the samples showed that the initial reported activity concentrations were anomalous. Tritium was not detected in any of the routine or duplicate soil samples collected and analyzed during the investigation. The radioactive isotopes - actinium 228, bismuth 212 and 214, lead 212 and 214, potassium 40, radium 224, 226 and 228, thallium 208, thorium 234 and uranium, were detected at low activity concentrations in the soil samples analyzed for radioactive constituents. The detected isotopes and their associated activity concentrations are typical of those naturally occurring in the marine-type sedimentary deposits underlying the Livermore Valley. No radiological controls are necessary for the soil evaluated.

54 ENVIRONMENTAL SCIENCES↗

GHG Emissions Reduction Audit: A Checklist for Owners

This guidance and accompanying checklist detail recommended services and deliverables for a building-level greenhouse gas (GHG) emissions reduction audit focused on Scope 1 and 2 GHG emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Materials in Extremes [Slides]

Goals: Realization of advanced predictive models that capture aspects of processing structure-properties-performance (PSPP) in ways that build on scale bridging, data science, and transformational physics insights from experiments; Based on a robust and seamless integration of sample manufacturing, characterization (pre- and post-mortem), theory and simulation, and novel experiments; Ultimately we want to be able to reliably predict performance, and control the functionality of materials in extreme environments.

36 MATERIALS SCIENCE↗

DOE BSSD Performance Management Metrics Report Q3

Microbiome data is complex, spanning information from microbial genomes within diverse communities, protein and metabolite readouts, and contextual information (metadata) captured from the environments from which these samples were collected. While the variety and scale of microbiome data generation has dramatically expanded over the past twenty years, infrastructure to support data management, sharing, and access has lagged. New ways to improve interoperability across existing resources and advancing community standards are necessary to support how researchers create, use, and reuse data. The National Microbiome Data Collaborative (NMDC) aims to advance a microbiome data sharing network through infrastructure, data standards, and community building.

54 ENVIRONMENTAL SCIENCES↗

A method for modeling battery-temperature-aware EV power profiles utilizing Next-Gen Profile data

With the expected increase in the number of electric vehicles (EVs) on the road in the coming years, it is important that analysis tools are capable of modeling and predicting the expected load on the power grid due to both individual EV charging sessions as well as large populations of vehicles. To do this accurately, the power profile of an EV charge session must be accurately modeled, including for scenarios where the temperature is above or below the ideal, and also take into account the nuances of manufacturer charging preferences. This paper introduces a method that utilizes the data in the Next-Gen Profile (NGP) data collection project to build a model of EV charging that takes into account the variations in charging power that occur due to off-nominal battery temperature and manufacturer preferences that limit power due to cold temperatures or high battery state-of-charge.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Optimization and stabilization of Fermilab Booster using hybrid Bayesian/RL framework

PIPII project will raise Fermilab Booster intensity and ramp rate. Beam losses will limit average power and are hard to simulate. Presently, Booster uses operator-guided empirical tuning. This task is challenging due to high dimensionality, multiple objectives, critical safety constraints, and drifts. We developed a synergistic suite of Bayesian optimization (BO) and reinforcement learning (RL) tools to optimize and stabilize beam losses. First, active learning was used to build a rough model. Data was collected parasitically using two novel safety constraint types – nonlinear input space restrictions (based on optics model), and uncertainty constraints (to stop bad steps/beam aborts). We then applied online multi-objective BO with scalarized objectives and fitting to improve/rebalance losses, increasing safety margins by 25%. Using BO model as a safety veto, we tried several on/off-policy RL agents for long term stabilization; SAC had best performance. We found that adding contextual (state) information further improved performance, eventually integrating key knobs like linac phase and temperature into the parameter space. Long term testing is ongoing to enable operational use.

Kuklev, Nikita [Fermilab]↗

Plant Engineers Solar Energy Handbook: Southern California Region

Discussed in order after the introduction are solar components and systems (collectors, storage, service hot water systems, space heating with liquid and air systems, space cooling, heat pumps and controls); computer programs for system optimization; local solar and weather data; a description of buildings and plants in Southern California applying solar technology; current Federal and California solar legislation; standards, codes and performance testing information; a listing of manufacturers, distributors, and professional services available in Southern California region; and information access. Finally, solar design check lists for those engineers who wish to design their own systems. The program for the Solar Workshop for the Plant Engineer, March 30, 1978, Los Angeles, California is included.

14 SOLAR ENERGY↗

KBase Silver Case Study: Determining Media Formulation Requirements for Isolation of Microbiome Constituents

KBase has powerful tools for extracting microbial genomes from metagenomes and performing phylogenomic analysis and metabolic modeling. These tools can be used to predict key media ingredients for isolating uncultured members of microbiomes. Essential to this process are high-quality genomes extracted from metagenomic assemblies, and Kbase has a tool for assessing the quality of genomes too. Below we identify growth factors for a myxobacteria ("slime bacteria") yet to be isolated from the rhizosphere of Miscanthus xgiganteus (hybrid of "Silvergrass"), cultivated at the Kellogg Biological Station in Michigan. Data was transferred with Globus from JGI-IMG. This narrative and the "KBase Gold Case Study: Can you find Delftia?" make up the Silver and Gold Narrative Set for teaching metagenomics concepts to students in the BIT 477/577 course at North Carolina State University. This tutorial will guide the user through the process of extracting and annotating high-quality genomes from a metagenomic data, performing phylogenomic analysis, building a metabolic model, and using these to predict nutrient requirments for growth and isolation of corresponding microbes.

59 BASIC BIOLOGICAL SCIENCES↗

Metagenomic Insight into Environmentally Challenged Methane-Fed Microbial Communities

In this study, we aimed to investigate, through high-resolution metagenomics and metatranscriptomics, the composition and the trajectories of microbial communities originating from a natural sample, fed exclusively with methane, over 14 weeks of laboratory incubation. This study builds on our prior data, suggesting that multiple functional guilds feed on methane, likely through guild-to-guild carbon transfer, and potentially through intraguild and intraspecies interactions. We observed that, under two simulated dioxygen partial pressures—low versus high—community trajectories were different, with considerable variability among the replicates. In all microcosms, four major functional guilds were prominently present, representing Methylococcaceae (the true methanotrophs), Methylophilaceae (the nonmethanotrophic methylotrophs), Burkholderiales, and Bacteroidetes. Additional functional guilds were detected in multiple samples, such as members of Opitutae, as well as the predatory species, suggesting additional complexity for methane-oxidizing communities. Metatranscriptomic analysis suggested simultaneous expression of the two alternative types of methanol dehydrogenases in both Methylococcaceae and Methylophilaceae, while high expression of the oxidative/nitrosative stress response genes suggested competition for dioxygen among the community members. The transcriptomic analysis further suggested that Burkholderiales likely feed on acetate that is produced by Methylococcaceae under hypoxic conditions, while Bacteroidetes likely feed on biopolymers produced by both Methylococcaceae and Methylophilaceae.

59 BASIC BIOLOGICAL SCIENCES↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Agenda for Multimodal Foundation Models for Earth Observation

Archives of remote sensing (RS) data are increasing swiftly as new sensing modalities with enhanced spatiotemporal resolution become operational. While promising new breakthroughs, the sheer volume of RS archives stretches the limits of human analysts and existing AI tools, as most models are: i) limited to single data modalities; ii) task-specific; iii) heavily reliant on labeled data. The emerging Foundation Models (FMs) have the potential to address these limitations. Trained on vast unlabeled datasets through self-supervised learning, FMs enable generic feature extraction that facilitate specialization to a wide variety of downstream tasks. This paper describes a vision towards an FM for multimodal Earth Observation data (FM4EO), discussing key building blocks and open challenges. We put particular emphasis on multimodal reasoning, a topic underexplored in EO. Our ultimate goal is a practical path toward FM4EO with capacity to unlock breakthroughs in few-shot learning scenarios, multimodal geographic knowledge integration, synthesis, and hypothesis generation.

Ambrozio Dias, Philipe↗

Interactive Rotated Object Detection for Novel Class Detection in Remotely Sensed Imagery

In this paper we propose IRTR-DETR an Interactive and Real-Time Rotated DEtection TRansformer that extends IRTDETR to predict rotated bounding boxes. IRTR-DETR maintains the Human-In-The-Loop (HIL) workflow of IRTDETR but introduces rotation-aware heads for improved detection of objects with arbitrary orientations. Similarly to IRTDETR IRTR-DETR can be trained with a small labeled sample set in an interactive setting but we show that it can also be pretrained on related but not identical data--such as a building damage dataset--before being applied to tasks like identifying buildings under construction. We demonstrate the efficacy of our approach on the publicly available Tiny-DOTA and xBD dataset as well as two study-cases on proprietary datasets of greenhouses and houses under construction ("waffle homes"). Detecting greenhouses is highly relevant in the context of damage assessment while "waffle homes" aid understanding typical floorplans and building codes in different areas both thereby supporting population modeling emergency response and policy planning. Our method outperforms the state of the art in interactive rotated object detection on the Tiny-DOTA dataset by 5.7 percent and improves upon the non interactive RTDETR by 7.85 to 19.39 percent (depending on the number of provided samples) while maintaining its real-time efficiency.

Burges, Marvin [ORNL] (ORCID:0000000312690769)↗

Comparing simulated demand flexibility against actual performance in commercial office buildings

Commercial building energy benchmarking has been used as a mechanism to evaluate energy use of a single building over time, relative to other similar buildings, or to simulations of a reference building conforming to various energy standards. Lack of empirical demand flexibility data and consistent flexibility metrics has limited the ability to compare demand flexibility performance with estimated demand flexibility in buildings. In this study, we collected demand response performance data for a total of 831 demand response events from 192 sites as a first step to build such a building demand flexibility dataset, and propose a standard core data schema to consolidate field data from different sources. We also performed parametric simulations of a control strategy called “global temperature adjustment” using commercial office prototype building models. We then compared the simulated demand flexibility performance against the actual data for offices with global temperature adjustment strategy implemented. During demand response events with an average outside air temperature of 34 °C (range 23 °C–42 °C), the measured demand decrease intensity of the demand flexibility metrics were 6.1 watts per square meter (W/m 2 ), 10.0 W/m 2 , 11.1 W/m 2 , 7.1 W/m 2 , and 4.7 W/m 2 for small, small–medium, medium, medium–large, and large office buildings, respectively. Compared to the measured data in medium- and large-size buildings, the simulated demand decrease intensity was 0.7 W/m 2 (17%) lower on average. The discrepancy between simulated and measured peak demand intensities fell within one standard deviation of the mean measured data. Here, the comparison results validate the credibility of simulations in capturing real building data for assessing the technical potential of building demand flexibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential of Data Center Controls in Grid Services

The rapid proliferation of large data centers brings both challenges and opportunities for grid reliability. The data center resources and their potential flexibility have the potential to contribute resources to grid operations. Through capabilities like energy shifting and resource coordination, data centers can help reduce their net demand on the transmission network, as well as provide additional grid services to support reliable operation on the grid. While transient and long-term grid planning and operations are the scenarios that draw most attention, the quasi-steady state timeseries (QSTS) operation of data centers and grid bring interesting scenarios that can help evaluate the data center controls to aid grid services. This work is focused on modeling data centers for QSTS applications – incorporating the AI data center load profiles and building on the PNNL digital twin model for the thermal management loads to enable simulation studies to reveal the impact of data center controls on grid performance. This includes the integration of a QSTS battery and natural gas generator model to incorporate local resource impacts to the system. The simulation study is performed with a modified IEEE 24-Bus transmission system. Scenarios are focused on evaluating the data center load impacts on the transmission system and leveraging both data center and local generation controls to mitigate those impacts and provide additional grid services. The data center controls revealed the ability to contribute to two main kinds of grid services: preventing congestion on a weak grid by coordinating the data center resources with the collocated BESS and onsite generation; and the ability to help the grid operations during stressed times of operation like during a contingency. Leveraging these and other capabilities has the potential to help data centers become grid responsive assets, aiding in both their integration into the power system and grid reliability.

power grid simulation↗

City-Scale Building Anthropogenic Heating during Heat Waves

More frequent and longer duration heat waves have been observed worldwide and are recognized as a serious threat to human health and the stability of electrical grids. Past studies have identified a positive feedback between heat waves and urban heat island effects. Anthropogenic heat emissions from buildings have a crucial impact on the urban environment, and hence it is critical to understand the interactive effects of urban microclimate and building heat emissions in terms of the urban energy balance. Here we developed a coupled-simulation approach to quantify these effects, mapping urban environmental data generated by the mesoscale Weather Research and Forecasting (WRF) coupled to Urban Canopy Model (UCM) to urban building energy models (UBEM). We conducted a case study in the city of Los Angeles, California, during a five-day heat wave event in September 2009. We analyzed the surge in city-scale building heat emission and energy use during the extreme heat event. We first simulated the urban microclimate at a high resolution (500 m by 500 m) using WRF-UCM. We then generated grid-level building heat emission profiles and aggregated them using prototype building energy models informed by spatially disaggregated urban land use and urban building density data. The spatial patterns of anthropogenic heat discharge from the building sector were analyzed, and the quantitative relationship with weather conditions and urban land-use dynamics were assessed at the grid level. The simulation results indicate that the dispersion of anthropogenic heat from urban buildings to the urban environment increases by up to 20% on average and varies significantly, both in time and space, during the heat wave event. The heat dispersion from the air-conditioning heat rejection contributes most (86.5%) of the total waste heat from the buildings to the urban environment. We also found that the waste heat discharge in inland, dense urban districts is more sensitive to extreme events than it is in coastal or suburban areas. The generated anthropogenic heat profiles can be used in urban microclimate models to provide a more accurate estimation of urban air temperature rises during heat waves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗