Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Lunar Latitude and Terrain Radiator Sensitivity Study

The thermal environment on the moon is highly complex and diverse. The lunar surface near the equator develops extreme hot average temperatures during the lunar day due to solar flux vectors that are nearly orthogonal to the surface. The lunar poles have a cold and uniquely complex thermal environment with low solar elevation angles and permanently shadowed regions located just kilometers from some of the most highly illuminated regions of the moon. Likewise, the topography can range from very flat crater basins to dramatically tall features such as mountains and crater rims. Consequently, when sizing the radiators of a lunar surface vehicle, the specific thermal environment found in the targeted landing or deployment zone must be well understood to build robust, appropriately scaled thermal control systems. Here described are parametric studies that characterize the sensitivity of lunar radiator performance to lunar terrain and latitude. Heat rejection is calculated for different radiator tilt angles in a variety of terrain environments. Radiator performance as a function of underside thermal condition is also characterized at lunar latitudes ranging from equatorial to polar. Impacts of latitude and terrain on radiator performance are quantified, and regions are identified where the thermal environment is more or less favorable for specific radiator designs.

Lunar Vehicle Radiator↗

Lunar Latitude and Terrain Radiator Sensitivity Study

The thermal environment on the moon is highly complex and diverse. The lunar surface near the equator develops extreme hot average temperatures during the lunar day due to solar flux vectors that are nearly orthogonal to the surface. The lunar poles have a cold and uniquely complex thermal environment with low solar elevation angles and permanently shadowed regions located just kilometers from some of the most highly illuminated regions of the moon. Likewise, the topography can range from very flat crater basins to dramatically tall features such as mountains and crater rims. Consequently, when sizing the radiators of a lunar surface vehicle, the specific thermal environment found in the targeted landing or deployment zone must be well understood to build robust, appropriately scaled thermal control systems. Here described are parametric studies that characterize the sensitivity of lunar radiator performance to lunar terrain and latitude. Heat rejection is calculated for different radiator tilt angles in a variety of terrain environments. Radiator performance as a function of underside thermal condition is also characterized at lunar latitudes ranging from equatorial to polar. Impacts of latitude and terrain on radiator performance are quantified, and regions are identified where the thermal environment is more or less favorable for specific radiator designs.

Lunar Thermal Analysis↗

Lunar Latitude and Terrain Radiator Sensitivity Study

The thermal environment on the moon is highly complex and diverse. The lunar surface near the equator develops extreme hot average temperatures during the lunar day due to solar flux vectors that are nearly orthogonal to the surface. The lunar poles have a cold and uniquely complex thermal environment with low solar elevation angles and permanently shadowed regions located just kilometers from some of the most highly illuminated regions of the moon. Likewise, the topography can range from very flat crater basins to dramatically tall features such as mountains and crater rims. Consequently, when sizing the radiators of a lunar surface vehicle, the specific thermal environment found in the targeted landing or deployment zone must be well understood to build robust appropriately scaled thermal control systems. Here described are parametric studies that characterize the sensitivity of lunar radiator performance to lunar terrain and latitude. Heat rejection is calculated for different radiator tilt angles in a variety of terrain environments. Radiator performance as a function of underside thermal condition is also characterized at lunar latitudes ranging from equatorial to polar. Impacts of latitude and terrain on radiator performance are quantified, and regions are identified where the thermal environment is more or less favorable for specific radiator designs.

Lunar Vehicle Radiator↗

Coupling subsurface and above-surface models for optimizing the design of borefields and district heating and cooling systems in the presence of varying water-table depth. In: Proceedings, 46th Workshop on Geothermal Reservoir Engineering

Dynamic energy simulation is important for the design and sizing of district heating and cooling systems with geothermal heat exchange. Current modeling approaches in building and district energy simulation tools typically consider heat conduction through the ground between boreholes, without flow of groundwater. On the other hand, detailed simulation tools for subsurface heat and mass transfer exist, but these fall short in simulating above-surface energy systems. To support the design and operation of such systems, we have developed a coupled model including a software package for building and district energy simulation, and software for detailed heat and mass transfer in the ground. For the first, we use the open-source Modelica Buildings Library, which includes dynamic simulation models for building and district energy and control systems. For the heat and mass transfer in the soil, we use the TOUGH simulator. TOUGH can model heat and multi-phase, multi-component mass transport for a variety of fluid systems, as well as chemical reactions, in fractured porous media. In previous work, we described the coupling of these software packages, including how time-dependent boundary conditions for the borehole walls are synchronized for use in Modelica and TOUGH. We verified that the coupled Modelica/TOUGH code produced consistent results with the original Modelica code for an idealized problem in which heat transfer was purely by conduction in a uniform geologic medium. Here, we examine less idealized problems for which TOUGH’s advanced capabilities for modeling fluid flow are required. The first problem has a shallow vadose zone, and the second problem has a thicker vadose zone with a water-table depth that varies in time, which requires a fine vertical grid discretization for the TOUGH model.

Doughtry, Christine↗

IEEE P2988: Recommended Practice of Use and Functions of Virtual Synchronous Machines

Power systems are going through a paradigm shift from centralized generation to distributed generation. This brings unprecedented challenges to power systems stability, reliability, and security. Operating power electronic converters as Virtual Synchronous Machines (VSMs) can bring backward compatibility to power systems, unify and harmonize the integration and interaction of future power systems players, and improve power system stability, reliability, and security. This is vital for the large-scale adoption of distributed energy resources, the advancement of sustainability, and the development of a low-carbon economy. This IEEE 2988 Recommended Practice will define the fundamental principles, mandatory functions, and optional functions of a VSM, i.e., a power electronic converter that is operated to behave like conventional synchronous machines. It will not describe or specify power semiconductor devices, hardware topologies, or micro-controllers that are used to build a VSM. This talk will discuss the activities and development plan for IEEE 2988 with the aim to engaging broad stakeholders and widening participation.

Zhong, Qing-Chang↗

Future Opportunities for LWR Irradiations in US Test Reactors

After several years of relatively low activity in the field of Light Water Reactor (LWR) fuel development, the Department of Energy again began to engage in developing new fuel technologies and irradiation performance data prompted by the Fukushima Daichi nuclear accidents. New competencies for irradiation testing in material test reactors in the United States began to be developed at this time using the Advanced Test Reactor (ATR), High Flux Isotope Reactor (HFIR), Massachusetts Institute of Technology Reactor (MITR), and the Transient Reactor Test Facility (TREAT). Capsules for testing fuel and cladding materials in ATR and HFIR were deployed, a Pressurized Water Reactor (PWR) condition loop for testing fuel rods was established in ATR, cladding corrosion studies were performed using a water loop in MITR, and TREAT pulse testing capabilities were commissioned for fuel rods in water capsules. The more recent and unexpected closure of the Halden Boiling Water Reactor (HBWR) also prompted further investments in Loss of Coolant Accident (LOCA) testing capabilities at TREAT. New configurations of these test devices show further potential in enhanced steam condition control and other investigations are building toward a flowing water loop for testing transient to dryout conditions. The closure of HBWR also prompted a major project currently underway to construct additional water loops in ATR where a novel approach is being pursued to enable Boiling Water Reactor (BWR) conditions. A meaningful collaborative project was awarded to MITR which, amidst an unexpected major overhaul of the reactor, has expanded cladding corrosion test capabilities at MITR. New explorations have led to methods for unique experiments at HFIR including channel box irradiations. New device developments are also bridging toward future potential for instrumented capsule irradiation tests in ATR and HFIR. Finally, a new project referred to as the System Physics Advanced Reactor Critical facility (SPARC) is gaining traction towards a large zero-power reactor able to produce physics validation data for LWR fuel bundle designs with increased enrichment and enhanced absorbers for 24-month operation cycles. This paper provides a brief summary of the status of these irradiation testbed capabilities with an emphasis on current efforts toward future capabilities to obtain new data and maximize the performance potential of LWR fuel technologies.

Woolstenhulme, Nicolas [Idaho National Laboratory ↗

Simulation-based assessment of ASHRAE Guideline 36, considering energy performance, indoor air quality, and control stability

This study assesses American Society of Heating, Refrigerating and Air-Conditioning Engineers Guideline 36 (G36) with a typical medium office building. Specifically, this study employed a Modelica model of a variable air volume (VAV) system that serves this building, which includes components for representing indoor virus transmission and filtration. It then implemented the G36 control sequences for both water-side and air-side equipment in Python. After that, this study conducted the assessment by co-simulating G36 and the Modelica model using the Building Operations Testing Framework. Unlike existing works, this work has three unique features: (1) It considers the interactions between control sequences for water-side and air-side equipment of the studied VAV system. (2) It assesses the performance of G36 from the perspective of IAQ. (3) It examines the short-term behaviors of the studied building under G36 to understand the control stability. This assessment confirms significant energy savings from G36, largely because of the interaction between supply air temperature and hot water controls. It also reveals a trade-off between the ability to slow the spread of virus and the energy performance via demand controlled ventilation. Lastly, it emphasizes the necessity of tuning local feedback control when implementing G36.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Point to Point Control of the Hydrogen Mixer

We continue to build on the theoretical modelling of a liquid hydrogen (LH2) and gas hydrogen (GH2) mixer subsystem. The mixer described in this work is responsible for combining high pressure LH2 and GH2 to produce a hydrogen flow that meets certain thermodynamic properties. The desired properties are maintained by precise control of the LH2 and GH2 flows. The mixer is modelled as a general multi-flow lumped volume for single constituent fluids using density and internal energy as states. The set of nonlinear differential equations is modelled in the SIMULINK environment including a table look-up feature of the fluid thermodynamic properties. A small signal (linear) model is developed based on the nonlinear model and simulated as well. Pulse disturbances are introduced to the valve positions and the quality of the linear model is ascertained by comparing its behavior against the nonlinear model simulations. Valve control strategies that simulate an operator-in-the-loop scenario are then explored demonstrating the need for automatic feedback control. Finally, optimal single-output and multi-output Proportional/Integral controllers are designed based on the linear model and applied to the nonlinear model with excellent results to track simultaneous, constant setpoint changes in desired exit flow, exit temperature, and mixer pressure, as well as to reject unmeasureable but bounded additive step perturbations in the valve positions.

Barbieri, Enrique↗

Enhanced modeling features within TREETOPS

The original motivation for TREETOPS was to build a generic multi-body simulation and remove the burden of writing multi-body equations from the engineers. The motivation of the enhancement was twofold: (1) to extend the menu of built-in features (sensors, actuators, constraints, etc.) that did not require user code; and (2) to extend the control system design capabilities by linking with other government funded software (NASTRAN and MATLAB). These enhancements also serve to bridge the gap between structures and control groups. It is common on large space programs for the structures groups to build hi-fidelity models of the structure using NASTRAN and for the controls group to build lower order models because they lack the tools to incorporate the former into their analysis. Now the controls engineers can accept the hi-fidelity NASTRAN models into TREETOPS, add sensors and actuators, perform model reduction and couple the result directly into MATLAB to perform their design. The controller can then be imported directly into TREETOPS for non-linear, time-history simulation.

Vandervoort, R. J.↗

Controlling distributed energy resources via deep reinforcement learning for load flexibility and energy efficiency

Behind-the-meter distributed energy resources (DERs), including building solar photovoltaic (PV) technology and electric battery storage, are increasingly being considered as solutions to support carbon reduction goals and increase grid reliability and resiliency. However, dynamic control of these resources in concert with traditional building loads, to effect efficiency and demand flexibility, is not yet commonplace in commercial control products. Traditional rule-based control algorithms do not offer integrated closed-loop control to optimize across systems, and most often, PV and battery systems are operated for energy arbitrage and demand charge management, and not for the provision of grid services. More advanced control approaches, such as MPC control have not been widely adopted in industry because they require significant expertise to develop and deploy. Recent advances in deep reinforcement learning (DRL) offer a promising option to optimize the operation of DER systems and building loads with reduced setup effort. However, there are limited studies that evaluate the efficacy of these methods to control multiple building subsystems simultaneously. Additionally, most of the research has been conducted in simulated environments as opposed to real buildings. This paper proposes a DRL approach that uses a deep deterministic policy gradient algorithm for integrated control of HVAC and electric battery storage systems in the presence of on-site PV generation. The DRL algorithm, trained on synthetic data, was deployed in a physical test building and evaluated against a baseline that uses the current best-in-class rule-based control strategies. Performance in delivering energy efficiency, load shift, and load shed was tested using price-based signals. The results showed that the DRL-based controller can produce cost savings of up to 39.6% as compared to the baseline controller, while maintaining similar thermal comfort in the building. The project team has also integrated the simulation components developed during this work as an OpenAIGym environment and made it publicly available so that prospective DRL researchers can leverage this environment to evaluate alternate DRL algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of Helical Slow-Wave Circuit Variations on TWT Cold-Test Characteristics

Recent advances in the state of the art of computer modeling offer the possibility for the first time to evaluate the effect that slow-wave structure parameter variations, such as manufacturing tolerances, have on the cold-test characteristics of helical traveling-wave tubes (TWT's). This will enable manufacturers to determine the cost effectiveness of controlling the dimensions of the component parts of the TWT, which is almost impossible to do experimentally without building a large number of tubes and controlling several parameters simultaneously. The computer code MAFIA is used in this analysis to determine the effect on dispersion and on-axis interaction impedance of several helical slow-wave circuit parameter variations, including thickness and relative dielectric constant of the support rods, tape width, and height of the metallized films deposited on the dielectric rods. Previous computer analyses required so many approximations that accurate determinations of the effect of many relevant dimensions on tube performance were practically impossible.

Kory, Carol L.↗

Effect of Helical Slow-Wave Circuit Variations on TWT Cold-Test Characteristics

Recent advances in the state of the art of computer modeling offer the possibility for the first time to evaluate the effect that slow-wave structure parameter variations, such'as manufacturing tolerances, have on the cold-test characteristics of helical traveling-wave tubes (TWT's). This will enable manufacturers to determine the cost effectiveness of controlling the dimensions of the component parts of the TWT, which is almost impossible to do experimentally without building a large number of tubes and controlling several parameters simultaneously. The computer code MAxwell's equations by the Finite Integration Algorithm (MAFIA) is used in this analysis to determine the effect on dispersion and on-axis interaction impedance of several helical slow-wave circuit parameter variations, including thickness and relative dielectric constant of the support rods, tape width, and height of the metallized films deposited on the dielectric rods. Previous computer analyzes required so many approximations that accurate determinations of the effect of many relevant dimensions on tube performance were practically impossible.

Kory, Carol L.↗

Effect of Helical Slow-Wave Circuit Variations on TWT Cold-Test Characteristics

Recent advances in the state of the art of computer modeling offer the possibility for the first time to evaluate the effect that slow-wave structure parameter variations, such as manufacturing tolerances, have on the cold-test characteristics of helical traveling-wave tubes (TWT's). This will enable manufacturers to determine the cost effectiveness of controlling the dimensions of the component parts of the TWT, which is almost impossible to do experimentally without building a large number of tubes and controlling several parameters simultaneously. The computer code MAFIA is used in this analysis to determine the effect on dispersion and on-axis interaction impedance of several helical slow-wave circuit parameter variations, including thickness and relative dielectric constant of the support rods, tape width, and height of the metallized films deposited on the dielectric rods. Previous computer analyzes required so many approximations that accurate determinations of the effect of many relevant dimensions on tube performance were practically impossible.

Kory, Carol L.↗

AI-Driven Smart Community Control for Accelerating PV Adoption and Enhancing Grid Resilience

Rapid deployment of residential photovoltaic (PV) systems helps decarbonize our electricity supplies, but under certain circumstances, high-penetration PV may pose challenges to the electrical distribution grid. In a project funded by the U.S. Department of Energy's Solar Energy Technologies Office and Building Technologies Office, the National Renewable Energy Laboratory and its partners studied how flexible building loads and battery storage, when coordinated at home-level and community-level scales, can be used to address those challenges and enhance grid resilience. In this webinar, we will discuss the methodology, simulation and field pilot results, insights from partners, and lessons learned from the project.

artificial intelligence↗

Human-System Interface Design Review Guidelines

The U.S. Nuclear Regulatory Commission (NRC) staff reviews the human factors engineering (HFE) aspects of nuclear power plants in accordance with the Standard Review Plan (NUREG-0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition). The Human Factors Engineering Program Review Model (NUREG-0711, Revision 3, issued November 2012) contains detailed design review procedures. As part of the review process, the interfaces between plant personnel and the plant's systems and components are evaluated for conformance with HFE guidelines. This document, Human-System Interface Design Review Guidelines (NUREG-0700, Revision 3), provides the guidelines necessary to perform this evaluation. The review guidelines address the physical and functional characteristics of human-system interfaces (HSIs). Because these guidelines only address the HFE aspects of design and not other related considerations, such as instrumentation and control and structural design, they are referred to as HFE guidelines. In addition to the review of actual HSIs, the NRC staff can use the NUREG-0700 guidelines to evaluate a design-specific HFE guidelines document or style guide. The HFE guidelines are organized into four basic parts, which are divided into sections. Part I contains guidelines for the basic HSI elements: information displays, user-interface interaction and management, and analog displays and controls. These elements are used as building blocks to develop HSI systems to serve specific functions. Part II contains the guidelines for reviewing the following HSI systems: alarm system, safety parameter display system, group-view display system, soft control system, computer-based procedure system, automation system, and communication system. Part III provides guidelines for the review of workstations and workplaces. Part IV provides guidelines for the review of HSI support (i.e., maintainability of digital systems and degraded HSI and instrumentation and control conditions).

42 ENGINEERING↗

A three-year dataset supporting research on building energy management and occupancy analytics

Abstract This paper presents the curation of a monitored dataset from an office building constructed in 2015 in Berkeley, California. The dataset includes whole-building and end-use energy consumption, HVAC system operating conditions, indoor and outdoor environmental parameters, as well as occupant counts. The data were collected during a period of three years from more than 300 sensors and meters on two office floors (each 2,325 m 2 ) of the building. A three-step data curation strategy is applied to transform the raw data into research-grade data: (1) cleaning the raw data to detect and adjust the outlier values and fill the data gaps; (2) creating the metadata model of the building systems and data points using the Brick schema; and (3) representing the metadata of the dataset using a semantic JSON schema. This dataset can be used in various applications—building energy benchmarking, load shape analysis, energy prediction, occupancy prediction and analytics, and HVAC controls—to improve the understanding and efficiency of building operations for reducing energy use, energy costs, and carbon emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy conservation and analysis and evaluation

The survey assembled and made recommendations directed at conserving utilities and reducing the use of energy at the Slidell Computer Complex. Specific items included were: (1) scheduling and controlling the use of gas and electricity, (2) building modifications to reduce energy, (3) replacement of old, inefficient equipment, (4) modifications to control systems, (5) evaluations of economizer cycles in HVAC systems, and (6) corrective settings for thermostats, ductstats, and other temperature and pressure control devices.

Source record↗

Design description of the Tangaye Village photovoltaic power system

The engineering design of a stand alone photovoltaic (PV) powered grain mill and water pump for the village of Tangaye, Upper Volta is described. The socioeconomic effects of reducing the time required by women in rural areas for drawing water and grinding grain were studied. The suitability of photovoltaic technology for use in rural areas by people of limited technical training was demonstrated. The PV system consists of a 1.8-kW (peak) solar cell array, 540 ampere hours of battery storage, instrumentation, automatic controls, and a data collection and storage system. The PV system is situated near an improved village well and supplies d.c. power to a grain mill and a water pump. The array is located in a fenced area and the mill, battery, instruments, controls, and data system are in a mill building. A water storage tank is located near the well. The system employs automatic controls which provide battery charge regulation and system over and under voltage protection. This report includes descriptions of the engineering design of the system and of the load that it serves; a discussion of PV array and battery sizing methodology; descriptions of the mechanical and electrical designs including the array, battery, controls, and instrumentation; and a discussion of the safety features. The system became operational on March 1, 1979.

Martz, J. E.↗