Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “below water”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Space Station Environmental Control and Life Support Systems: An Update on Waste Water Reclamation

Since the mid-1980's, work has been ongoing In the development of the various environmental control and life support systems (ECLSS) for the space station. Part of this effort has been focused on the development of a new subsystem to reclaim waste water that had not been previously required for shuttle missions. Because of the extended manned missions proposed, reclamation of waste water becomes imperative to avoid the weight penalties associated with resupplying a crew's entire water needs for consumption and daily hygiene. Hamilton Standard, under contract to Boeing Aerospace and Electronics, has been designing the water reclamation system for space station use. Since June of 1991, Hamilton Standard has developed a combined water processor capable of reclaiming potable quality water from waste hygiene water, used laundry water, processed urine, Shuttle fuel cell water, humidity condensate and other minor waste water sources. The system was assembled and then tested with over 27,700 pounds of 'real' waste water. During the 1700 hours of system operation required to process this waste water, potable quality water meeting NASA and Boeing specifications was produced. This paper gives a schematic overview of the system, describes the test conditions and test results and outlines the next steps for system development.

Ferner, Kathleen M.↗

The Dynamics of a Semi-Arid Region in Response to Climate and Water - Use Policy

The objectives of this project were to determine the response of semi-arid ecosystems to the combined forcings of climate variability and anthropogenic stress. Arid and semi-arid systems encompass close to 40% of the worlds land surface. The ecology of these regions are principally limited by water, and as the water resources wax and wane, so should the health and vigor of the ecosystems. Water, however, is a necessary and critical resource for humans living in these same regions. Thus for many and and semi-arid regions the natural systems and human systems are in direct competition for a limited resource. Increasing competition through development of and and semi-arid regions, export of water resources, as well as potential persistent changes in weather patterns are likely to lead to fundamental changes in carrying capacity, resilience, and ecology of these regions. A detailed understanding of these systems respond to forcing on a regional and local scale is required in order to better prepare for and manage future changes in the availability of water. In the Owens Valley CA, decadal changes in rainfall and increased use of groundwater resources by Los Angles (which derives 60-70% of its water from this region) have resulted in a large-scale experiment on the impacts of these changes in semi-arid ecosystems. This project works directly with the Inyo County Water Department (local water authority) and the Los Angles Department of Water and Power (regional demand on water resources) to understand changes, their causes, and impacts. Very detailed records have been kept for a number of selected sites in the valley which provide essential ground truth. These results are then scaled up through remote sensed data to regions scale to assess large scale patterns and link them to the fundamental decisions regarding the water resources of this region. A fundamental goal is to understand how resilient the native ecosystems are to large changes in water resources. Are they are on a spring (remove and return resources, do the systems return to the original state) or a vector (when water returns have the systems fundamentally changed).

Mustard, John F.↗

ICESat Observations of Inland Surface Water Stage, Slope, and Extent: a New Method for Hydrologic Monitoring

River discharge and changes in lake, reservoir and wetland water storage are critical terms in the global surface water balance, yet they are poorly observed globally and the prospects for adequate observations from in-situ networks are poor (Alsdorf et al., 2003). The NASA-sponsored Surface Water Working Group has established a framework for advancing satellite observations of river discharge and water storage changes which focuses on obtaining measurements of water surface height (stage), slope, and extent. Satellite laser altimetry, which can achieve centimeter-level elevation precision for single, small laser footprints, provides a method to obtain these inland water parameters and contribute to global water balance monitoring. Since its launch in January, 2003 the Ice, Cloud, and land Elevation Satellite (ICESat), a NASA Earth Observing System mission, has achieved over 540 million laser pulse observations of ice sheet, ocean surface, land topography, and inland water elevations and cloud and aerosol height distributions. By recording the laser backscatter from 80 m diameter footprints spaced 175 m along track, ICESat acquires globally-distributed elevation profiles, using a 1064 nm laser altimeter channel, and cloud and aerosol profiles, using a 532 nm atmospheric lidar channel. The ICESat mission has demonstrated the following laser altimeter capabilities relevant to observations of inland water: (1) elevation measurements with a precision of 2 to 3 cm for flat surfaces, suitable for detecting river surface slopes along long river reaches or between multiple crossings of a meandering river channel, (2) from the laser backscatter waveform, detection of water surface elevations beneath vegetation canopies, suitable for measuring water stage in flooded forests, (3) single pulse absolute elevation accuracy of about 50 cm (1 sigma) for 1 degree sloped surfaces, with calibration work in progress indicating that a final accuracy of about 12 cm (1 sigma) will be achieved for clear atmosphere conditions, suitable for detection of stage changes through time, (4) ability to precisely point the spacecraft so as to position the laser profile on the Earth the surface with a cross-track accuracy of 50 m (1 sigma), enabling small water bodies and specific locations to be targeted and re-observed through time, (5) adequate signal levels from specular water surfaces up to 5 degrees off-nadir, enabling complete global access to any location on the Earth's surface from the ICESat repeat orbit by off-nadir pointing, and (6) day and night operation with successful laser ranging to the Earth's surface through thin to moderate cloud cover, enabling more frequent measurements than can be achieved by passive optical sensors. Here we illustrate these capabilities by showing ICESat observations through time for selected river and lake locations.

Harding, David J.↗

Modeling the interaction Between Ethylene Diamine and Water Films on the Surface of a Carbon Nanotube

It has been observed that a carbon nanotube (CNT) AFM tip coated with ethylene diamine (EDA) penetrates the liquid water-air interface more easily than an uncoated nanotube tip. The EDA coating remains intact through repeated cycles of dipping and removal. In order to understand the physical basis for this observation, we use ab initio quantum chemistry calculations to study the EDA-CNT-water interaction and to parameterize a force field describing this system. Molecular dynamics (MD) simulations are carried out for EDA-water mixtures and an EDA-coated carbon nanotube immmed in water. These simulations are similar to our earlier MD study that characterized the CNT-water interface. The attractive CNT-EDA and CNT-water interactions arise primarily from van der Waals forces, and the EDA-EDA, EDA-water and water-water interactions are mainly due to hydrogen bond formation. The binding energ of single EDA molecule to the nanotube is nearly three times larger than the corresponding value found for water (4.3 versus 1.5 kcal mol, respectively). The EDA molecules readily stick to and diffuse along the CNT surface. As a resulf mixing of the EDA and water films does not occur on the timescale of the MD simulations. The EDA film reduces the hydrophobicity of the nanotube surface and acts like a prototypical surfactant in stabilizing the suspension of carbon nanotubes in water. For this presentation, we use the MD simulations to determine how the presence of the carbon nanotube surface perturbs the properties of EDA-water mixtures.

Jaffe, Richard L.↗

Establishing the Global Fresh Water Sensor Web

This paper presents an approach to measuring the major components of the water cycle from space using the concept of a sensor-web of satellites that are linked to a data assimilation system. This topic is of increasing importance, due to the need for fresh water to support the growing human population, coupled with climate variability and change. The net effect is that water is an increasingly valuable commodity. The distribution of fresh water is highly uneven over the Earth, with both strong latitudinal distributions due to the atmospheric general circulation, and even larger variability due to landforms and the interaction of land with global weather systems. The annual global fresh water budget is largely a balance between evaporation, atmospheric transport, precipitation and runoff. Although the available volume of fresh water on land is small, the short residence time of water in these fresh water reservoirs causes the flux of fresh water - through evaporation, atmospheric transport, precipitation and runoff - to be large. With a total atmospheric water store of approx. 13 x 10(exp 12)cu m, and an annual flux of approx. 460 x 10(exp 12)cu m/y, the mean atmospheric residence time of water is approx. 10 days. River residence times are similar, biological are approx. 1 week, soil moisture is approx. 2 months, and lakes and aquifers are highly variable, extending from weeks to years. The hypothesized potential for redistribution and acceleration of the global hydrological cycle is therefore of concern. This hypothesized speed-up - thought to be associated with global warming - adds to the pressure placed upon water resources by the burgeoning human population, the variability of weather and climate, and concerns about anthropogenic impacts on global fresh water availability.

Hildebrand, Peter H.↗

Crew Exploration Vehicle (CEV) Potable Water System Verification Description

The Crew Exploration Vehicle (CEV), also known as Orion, will ferry a crew of up to six astronauts to the International Space Station (ISS), or a crew of up to four astronauts to the moon. The first launch of CEV is scheduled for approximately 2014. A stored water system on the CEV will supply the crew with potable water for various purposes: drinking and food rehydration, hygiene, medical needs, sublimation, and various contingency situations. The current baseline biocide for the stored water system is ionic silver, similar in composition to the biocide used to maintain quality of the water transferred from the Orbiter to the ISS and stored in Contingency Water Containers (CWCs). In the CEV water system, the ionic silver biocide is expected to be depleted from solution due to ionic silver plating onto the surfaces of the materials within the CEV water system, thus negating its effectiveness as a biocide. Since the biocide depletion is expected to occur within a short amount of time after loading the water into the CEV water tanks at the Kennedy Space Center (KSC), an additional microbial control is a 0.1 micron point of use filter that will be used at the outlet of the Potable Water Dispenser (PWD). Because this may be the first time NASA is considering a stored water system for longterm missions that does not maintain a residual biocide, a team of experts in materials compatibility, biofilms and point of use filters, surface treatment and coatings, and biocides has been created to pinpoint concerns and perform testing to help alleviate those concerns related to the CEV water system. Results from the test plans laid out in the paper presented to SAE last year (Crew Exploration Vehicle (CEV) Potable Water System Verification Coordination, 2008012083) will be detailed in this paper. Additionally, recommendations for the CEV verification will be described for risk mitigation in meeting the physicochemical and microbiological requirements on the CEV PWS.

Peterson, Laurie↗

Water Detection Based on Sky Reflections

This software has been designed to detect water bodies that are out in the open on cross-country terrain at mid- to far-range (approximately 20 100 meters), using imagery acquired from a stereo pair of color cameras mounted on a terrestrial, unmanned ground vehicle (UGV). Non-traversable water bodies, such as large puddles, ponds, and lakes, are indirectly detected by detecting reflections of the sky below the horizon in color imagery. The appearance of water bodies in color imagery largely depends on the ratio of light reflected off the water surface to the light coming out of the water body. When a water body is far away, the angle of incidence is large, and the light reflected off the water surface dominates. We have exploited this behavior to detect water bodies out in the open at mid- to far-range. When a water body is detected at far range, a UGV s path planner can begin to look for alternate routes to the goal position sooner, rather than later. As a result, detecting water hazards at far range generally reduces the time required to reach a goal position during autonomous navigation. This software implements a new water detector based on sky reflections that geometrically locates the exact pixel in the sky that is reflecting on a candidate water pixel on the ground, and predicts if the ground pixel is water based on color similarity and local terrain features

Rankin, Arturo L.↗

Module for Oxygenating Water without Generating Bubbles

A module that dissolves oxygen in water at concentrations approaching saturation, without generating bubbles of oxygen gas, has been developed as a prototype of improved oxygenators for water-disinfection and water-purification systems that utilize photocatalyzed redox reactions. Depending on the specific nature of a water-treatment system, it is desirable to prevent the formation of bubbles for one or more reasons: (1) Bubbles can remove some organic contaminants from the liquid phase to the gas phase, thereby introducing a gas-treatment problem that complicates the overall water-treatment problem; and/or (2) in some systems (e.g., those that must function in microgravity or in any orientation in normal Earth gravity), bubbles can interfere with the flow of the liquid phase. The present oxygenation module (see Figure 1) is a modified version of a commercial module that contains >100 hollow polypropylene fibers with a nominal pore size of 0.05 m and a total surface area of 0.5 m2. The module was originally designed for oxygenation in a bioreactor, with no water flowing around or inside the tubes. The modification, made to enable the use of the module to oxygenate flowing water, consisted mainly in the encapsulation of the fibers in a tube of Tygon polyvinyl chloride (PVC) with an inside diameter of 1 in. (approx.=25 mm). In operation, water is pumped along the insides of the hollow fibers and oxygen gas is supplied to the space outside the hollow tubes inside the PVC tube. In tests, the pressure drops of water and oxygen in the module were found to be close to zero at water-flow rates ranging up to 320 mL/min and oxygen-flow rates up to 27 mL/min. Under all test conditions, no bubbles were observed at the water outlet. In some tests, flow rates were chosen to obtain dissolved-oxygen concentrations between 25 and 31 parts per million (ppm) . approaching the saturation level of approx.=35 ppm at a temperature of 20 C and pressure of 1 atm (approx.=0.1 MPa). As one would expect, it was observed that the time needed to bring a flow of water from an initial low dissolved-oxygen concentration (e.g., 5 ppm) to a steady high dissolved-oxygen concentration at or near the saturation level depends on the rates of flow of both oxygen and water, among other things. Figure 2 shows the results of an experiment in which a greater flow of oxygen was used during the first few tens of minutes to bring the concentration up to approx.=25 ppm, then a lesser flow was used to maintain the concentration.

Gonzalez-Martin, Anuncia↗

ISS Potable Water Quality for Expeditions 26 through 30

International Space Station (ISS) Expeditions 26-30 spanned a 16-month period beginning in November of 2010 wherein the final 3 flights of the Space Shuttle program finished ISS construction and delivered supplies to support the post-shuttle era of station operations. Expedition crews relied on several sources of potable water during this period, including water recovered from urine distillate and humidity condensate by the U.S. water processor, water regenerated from humidity condensate by the Russian water recovery system, and Russian ground-supplied potable water. Potable water samples collected during Expeditions 26-30 were returned on Shuttle flights STS-133 (ULF5), STS-134 (ULF6), and STS-135 (ULF7), as well as Soyuz flights 24-27. The chemical quality of the ISS potable water supplies continued to be verified by the Johnson Space Center s Water and Food Analytical Laboratory (WAFAL) via analyses of returned water samples. This paper presents the chemical analysis results for water samples returned from Expeditions 26-30 and discusses their compliance with ISS potable water standards. The presence or absence of dimethylsilanediol (DMSD) is specifically addressed, since DMSD was identified as the primary cause of the temporary rise and fall in total organic carbon of the U.S. product water that occurred in the summer of 2010.

Straub, John E., II↗

International Space Station Potable Water Characterization for 2013

In this post-construction, operational phase of International Space Station (ISS) with an ever-increasing emphasis on its use as a test-bed for future exploration missions, the ISS crews continue to rely on water reclamation systems for the majority of their water needs. The onboard water supplies include US Segment potable water from humidity condensate and urine, Russian Segment potable water from condensate, and ground-supplied potable water, as reserve. In 2013, the cargo returned on the Soyuz 32-35 flights included archival potable water samples collected from Expeditions 34-37. The Water and Food Analytical Laboratory at the NASA Johnson Space Center continued its long-standing role of performing chemical analyses on ISS return water samples to verify compliance with potable water quality specifications. This paper presents and discusses the analytical results for potable water samples returned from Expeditions 34-37, including a comparison to ISS quality standards. During the summer of 2013, the U.S. Segment potable water experienced an anticipated temporary rise and fall in total organic carbon (TOC) content, as the result of organic contamination breaking through the water system's treatment process. Analytical results for the Expedition 36 archival samples returned on Soyuz 34 confirmed that dimethylsilanediol was once again the responsible contaminant, just as it was for comparable TOC rises in 2010 and 2012. Discussion herein includes the use of the in-flight Total Organic Carbon Analyzer (TOCA) as a key monitoring tool for tracking these TOC rises and scheduling appropriate remediation action.

Straub, John E. II↗

International Space Station Potable Water Characterization for 2013

In this post-construction, operational phase of International Space Station (ISS) with an ever-increasing emphasis on its use as a test-bed for future exploration missions, the ISS crews continue to rely on water reclamation systems for the majority of their water needs. The onboard water supplies include U.S. Segment potable water from humidity condensate and urine, Russian Segment potable water from condensate, and ground-supplied potable water, as reserve. In 2013, the cargo returned on the Soyuz 32-35 flights included archival potable water samples collected from Expeditions 34-37. The former Water and Food Analytical Laboratory (now Toxicology and Evironmental Chemistry Laboratory) at the NASA Johnson Space Center continued its long-standing role of performing chemical analyses on ISS return water samples to verify compliance with potable water quality specifications. This paper presents and discusses the analytical results for potable water samples returned from Expeditions 34-37, including a comparison to ISS quality standards. During the summer of 2013, the U.S. Segment potable water experienced a third temporary rise and fall in total organic carbon (TOC) content, as the result of organic contamination breaking through the water system's treatment process. Analytical results for the Expedition 36 archival samples returned on Soyuz 34 confirmed that dimethylsilanediol was once again the responsible contaminant, just as it was for the previous comparable TOC rises in 2010 and 2012. Discussion herein includes the use of the in-flight total organic carbon analyzer (TOCA) as a key monitoring tool for tracking these TOC rises and scheduling appropriate remediation.

Straub, John E., II↗

2014 ISS Potable Water Characterization and Continuation of the DMSD Chronicle

During 2014 the crews from Expeditions 38-41 were resident on the International Space Station (ISS). In addition to the U.S. potable water reclaimed from humidity condensate and urine, the other water supplies available for their use were Russian potable water reclaimed from condensate and Russian ground-supplied potable water. Beginning in June of 2014, and for the fourth time since 2010, the product water from the U.S. Water Processor Assembly (WPA) experienced a rise in the total organic carbon (TOC) level due to organic contaminants breaking through the water treatment process. Results from ground analyses of ISS archival water samples returned on Soyuz 38 confirmed that dimethylsilanediol (DMSD) was once again the contaminant responsible for the rise. With this confirmation in hand and based upon the low toxicity of DMSD, a waiver was approved to allow the crew to continue to consume the water after the TOC level exceeded the U.S. Segment limit of 3 mg/L. Several weeks after the WPA multifiltration beds were replaced, as anticipated based upon experience from previous rises, the TOC levels returned to below the method detection limit of the onboard TOC analyzer (TOCA). This paper presents and discusses the chemical analysis results for the ISS archival potable water samples returned in 2014 and analyzed by the Johnson Space Center's Toxicology and Environmental Chemistry laboratory. These results showed compliance with ISS potable water quality standards and indicated that the potable water supplies were acceptable for crew consumption. Although DMSD levels were at times elevated they remained well below the 35 mg/L health limit, so continued consumption of the U.S potable water was considered a low risk to crew health and safety. Excellent agreement between inflight and archival sample TOC data confirmed that the TOCA performed optimally and it continued to serve as a vital tool for monitoring organic breakthrough and planning remediation action.

Straub, John E., II↗

A Water Rich Mars Surface Mission Scenario

The surface of Mars once had abundant water flowing on its surface, but now there is a general perception that this surface is completely dry. Several lines of research have shown that there are sources of potentially large quantities of water at many locations on the surface, including regions considered as candidates for future human missions. Traditionally, system designs for these human missions are constrained to tightly recycle water and oxygen, and current resource utilization strategies involve ascent vehicle oxidizer production only. But the assumption of relatively abundant extant water may change this. Several scenarios were constructed to evaluate water requirements for human Mars expeditions to assess the impact to system design if locally produced water is available. Specifically, we have assessed water resources needed for 1) ascent vehicle oxidizer and fuel production, 2) open-loop water and oxygen life support requirements along with more robust usage scenarios, and 3) crew radiation protection augmentation. In this assessment, production techniques and the associated chemistry to transform Martian water and atmosphere into these useful commodities are identified, but production mass and power requirements are left to future analyses. The figure below illustrates the type of water need assessment performed and that will be discussed. There have been several sources of feedstock material discussed in recent literature that could be used to produce these quantities of water. This paper will focus on Mars surface features that resemble glacier-like forms on Earth. Several lines of evidence indicate that some of these features are in fact buried ice, likely remnants from an earlier ice age on Mars. This paper examines techniques and hardware systems used in the polar regions of Earth to access this buried ice and withdraw water from it. These techniques and systems will be described to illustrate options available. A technique known as a Rodriguez Well is assessed as a likely method for extracting water from these bodies of ice. The figure below is a sample of results from this assessment that will be discussed.

Hoffman, Stephen↗

2014 ISS Potable Water Characterization and Continuation of the Dimethylsilanediol Chronicle

During 2014 the crews from Expeditions 38-41 were in residence on the International Space Station (ISS). In addition to the U.S. potable water reclaimed from humidity condensate and urine, the other water supplies available for their use were Russian potable water reclaimed from condensate and Russian ground-supplied potable water. Beginning in June of 2014 and for the fourth time since 2010, the product water from the U.S. water processor assembly (WPA) experienced a rise in the total organic carbon (TOC) level due to organic contaminants breaking through the water treatment process. Results from ground analyses of ISS archival water samples returned on Soyuz 38 confirmed that dimethylsilanediol was once again the contaminant responsible for the rise. With this confirmation in hand and based upon the low toxicity of dimethylsilanediol, a waiver was approved to allow the crew to continue to consume the water after the TOC level exceeded the U.S. Segment limit of 3 mg/L. Several weeks after the WPA multifiltration beds were replaced, the TOC levels returned to below the method detection limit of the onboard TOC analyzer (TOCA) as anticipated based upon experience from previous rises. This paper presents and discusses the chemical analysis results for the ISS archival potable-water samples returned in 2014 and analyzed by the Johnson Space Center's Toxicology and Environmental Chemistry laboratory. These results showed compliance with ISS potable water quality standards and indicated that the potable-water supplies were acceptable for crew consumption. Although dimethylsilanediol levels were at times elevated, they remained well below the 35 mg/L health limit so the continued consumption of the U.S. potable water was considered a low risk to crew health and safety. Excellent agreement between in-flight and archival sample TOC data confirmed that the TOCA performed optimally and continued to serve as a vital tool for monitoring organic breakthrough and planning remediation action.

Straub, John E., II↗

Simultaneous Ice Water Content Measurements at Multiple Locations on the NASA DC-8 Aircraft during the 2018 HIWC RADAR Flight Campaign

Ice water content measurements were made simultaneously at three locations on the NASA DC-8 in natural, glaciated conditions during the 2018 High Ice Water Content RADAR flight campaign. The purpose of these measurements was to further evaluate efficiency factors of hot-wire total water content probes in glaciated conditions and investigate the enhancement of ice crystal concentrations near fuselage surfaces due to flow field inertial effects, and ice crystals impacting the nose, breaking up, and flowing downstream. The total water content measurements were made using either Science Engineering Associates Ice Crystal Detectors or Robust Probes. Three common sensors were mounted on an underwing canister considered to be in near free-flow conditions, a standoff from a fuselage window, and the nose of the fuselage near the pitot probes. The Ice Crystal Detector total water content sensor and Robust Probe sensor collection and retention efficiencies were evaluated through comparisons with the underwing Ice Crystal Detector and Robust Probe measurements to the IKP2 isokinetic evaporator probe, which provided the reference ice water content measurement. Local ice water content at the nose position was evaluated by comparing ratios of the nose and underwing ice crystal detectors to the IKP2. Local ice water content at the window-standoff location was also evaluated by comparing total water content sensor measurements from the window ice crystal detector to the measurements made with the underwing and nose Ice Crystal Detectors The key findings were: 1) the Ice Crystal Detector total water content sensor ice water content efficiency factor was similar to previous estimates, but reduced with increased ice crystal median mass diameter; 2) the ice water content at the fuselage nose location near the DC-8 pitot probes was approximately 2.5 times the freestream values – although this estimate is affected by a higher probe efficiency factor due to smaller particles in the debris cloud from impacts upstream of the probe; and 3) the ice water content at the 17” standoff from the port window varied from about 50% to 3 times freestream values in a complicated manner. Similar measurement locations are not uncommon on cloud research aircraft, where ice particle measurements may be subject to similar uncertainties.

Aircraft Icing↗

Simultaneous Ice Water Content Measurements at Multiple Locations on the NASA DC-8 Aircraft during the 2018 HIWC RADAR Flight Campaign

Ice water content measurements were made simultaneously at three locations on the NASA DC-8 in natural, glaciated conditions during the 2018 High Ice Water Content RADAR flight campaign. The purpose of these measurements was to further evaluate efficiency factors of hot-wire total water content probes in glaciated conditions and investigate the enhancement of ice crystal concentrations near fuselage surfaces due to flow field inertial effects, and ice crystals impacting the nose, breaking up, and flowing downstream. The total water content measurements were made using either Science Engineering Associates Ice Crystal Detectors or Robust Probes. Three common sensors were mounted on an underwing canister considered to be in near free-flow conditions, a standoff from a fuselage window, and the nose of the fuselage near the pitot probes. The Ice Crystal Detector total water content sensor and Robust Probe sensor collection and retention efficiencies were evaluated through comparisons with the underwing Ice Crystal Detector and Robust Probe measurements to the IKP2 isokinetic evaporator probe, which provided the reference ice water content measurement. Local ice water content at the nose position was evaluated by comparing ratios of the nose and underwing ice crystal detectors to the IKP2. Local ice water content at the window-standoff location was also evaluated by comparing total water content sensor measurements from the window ice crystal detector to the measurements made with the underwing and nose Ice Crystal Detectors The key findings were: 1) the Ice Crystal Detector total water content sensor ice water content efficiency factor was similar to previous estimates, but reduced with increased ice crystal median mass diameter; 2) the ice water content at the fuselage nose location near the DC-8 pitot probes was approximately 2.5 times the freestream values – although this estimate is affected by a higher probe efficiency factor due to smaller particles in the debris cloud from impacts upstream of the probe; and 3) the ice water content at the 17” standoff from the port window varied from about 50% to 3 times freestream values in a complicated manner. Similar measurement locations are not uncommon on cloud research aircraft, where ice particle measurements may be subject to similar uncertainties.

o Aircraft Icing↗

System and method of water purification utilizing an ionomer membrane

A water purification system utilizes an ionomer membrane and mild vacuum to draw water from source water through the membrane. A water source may be salt water or a contaminated water source. The water drawn through the membrane passes across the condenser chamber to a condenser surface where it is condensed into purified water. The condenser surface may be metal or any other suitable surface and may be flat or pleated. In addition, the condenser surface may be maintained at a lower temperature than the water on the water source side of the membrane. The ionomer membrane may be configured in a cartridge, a pleated or flat plate configuration. A latent heat loop may be configured to carry the latent heat of vaporization from the condenser back to the water source side of the ionomer membrane. The source water may be heated by a solar water heater.

Bahar, Bamdad↗

Redefining Net-Zero Water for Resilient Aquifers

Groundwater has long been a critical source of potable water, supplying one-third of all global water withdrawals and providing strategic reserves in times of drought (Konikow, 2012; Famiglietti, 2014). The risk in relying on groundwater is that it is often pumped at rates far greater than it can be naturally replenished. With increasing population and a changing climate, the depletion of potable water supplies has become an ever-growing concern (Srinivasan et al., 2012). Recently, the concept of “resilience” has been applied to groundwater, leaving many questions to be explored in terms of what resilience should mean for aquifers (Foster and MacDonald, 2014; Grönwall and Oduro-Kwarteng, 2017). The term is commonly used to indicate resilience to impacts of climate change specifically, but here we consider resilience in the context of more general water insecurity. Relatedly, the concept of “sustainable yield” has emerged in an attempt to determine a metric that can ensure the long-term resilience of groundwater systems, but the definition is fraught with inherent uncertainties and its quantification poses challenges (Rudestam and Langridge, 2014; Grönwall and Oduro-Kwarteng, 2017). At the heart of these concepts is a focus on sustainable management of aquifers. A sustainable approach to managing groundwater resources usually involves balancing long-term abstraction with the long-term recharge taking into account the needs for environmental flows and implementing drought-preparedness measures (Robins et al. 2006; Foster and MacDonald, 2014). At a high level, a sustainable balance of groundwater abstraction versus aquifer recharge may be considered “Net Zero” (NZ) or “Net Positive” (NP) in cases where recharge is equal to or in excess of abstraction, respectively. However, NZ/NP water management programs that address these concerns have varied definitions of compliance, which include considerations for the application at hand (ILFI, 2020; USGBC, 2020). Locations with high risk of low or poor water supply may be particularly interested in pursuing NZ/NP water. The AQUEDUCT Water Risk Atlas (World Resources Institute, 2019) indicates long-term availability, providing risk levels for quantity and quality of water at specific locations across the globe, for existing and predicted future conditions. This paper follows the U.S. Department of Energy (DOE) Federal Energy Management Program (FEMP) NZ water definition adopted by the U.S. Army for use at their installations, including Army Reserve Centers (ARCs). This definition also relates to the U.S. Army’s current focus on water resilience, which includes short-term and long-term availability of water resources.

net zero water, HUC12, Saipan, American Samoa, Mau↗