Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam dynamics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Quadrupolar mode measurements for space charge dominated beams

On-line monitoring of beam quality requires non-invasive transverse phase space diagnostics. Emittance measurement is particularly challenging for high-intensity particle beams, since space charge complicates the beam dynamics during measurement. Quadrupolar mode measurements have been empirically shown to provide information about the beam emittance, but so far only for small relative space charge effects, where the results depend on a linear theory. We present a quadrupolar mode measurement for space charge dominated beams with unsplit tunes using multi-turn resonant excitation. Furthermore, results from experiments performed at the University of Maryland Electron Ring (UMER) are compared to both analytic and numerical analysis of the rms envelope equations.

43 PARTICLE ACCELERATORS↗

Fully plasma-based electron injector for a linear collider or XFEL

We demonstrate through high-fidelity particle-in-cell (PIC) simulations a simple approach for efficiently generating 20 + GeV electron beams with the necessary charge, energy spread, and emittance for use as an injector in a future linear collider or a next generation XFEL. A high quality injected bunch is generated by self-focusing an unmatched electron driver in a nonlinear plasma wakefield. Over pump depletion distances, the drive beam dynamics and self-loading effects lead to high energy, low-energy spread output beams. For plasma densities of 10 18 c⁢m −3 , PIC simulation results indicate that self-injected beams with 0.52 n⁢C charge can be accelerated to 20 GeV with projected core energy spreads of ≲ 1%, normalized slice emittances of 110n⁢m, peak normalized brightness of ≳ 10 19 A/m 2 /rad 2 , and transfer efficiencies of ≳ 44%.

Particle acceleration in plasmas↗

Improved DC Gun and Insulator Assembly

Many user facilities such as synchrotron radiation light sources and free electron lasers rely on DC high voltage photoguns with internal field gradients as high as 10 to 15 MV/m. These high gradients often lead to field emission which poses serious problems for the photocathode used to generate the electron beam and the ceramic insulators used to bias the photocathode at high voltage. Ceramic insulators are difficult to manufacture, require long commissioning times, and have poor reliability, in part because energetic electrons bury themselves in the ceramic causing a buildup of charge and eventual puncture, and also because large diameter ceramics are difficult to braze reliably. The lifetimes of photo cathodes inside high current DC guns exhibiting field emission are limited to less than a hundred hours. Reducing the surface gradients on the metals reduces the field emission, which serves to maintain the required ultrahigh vacuum condition. A novel gun design with gradients around 5 MV/m and operating at 350 kV, a major improvement over existing designs, was proposed that allows for the in-situ replacement of photo cathodes in axially symmetric designs using inverted ceramics. In this project, the existing JLAB CEBAF asymmetric gun design with an inverted ceramic support was modeled and the beam dynamics characterized. An improved structure was designed that reduces the surface gradients and improves the beam optics. To minimize the surface gradients, a number of electrostatic gun designs were studied to determine the optimum configuration of the critical electrodes within the gun structure. Coating experiments were carried out to create a charge dissipative coating for cylindrical ceramics. The phase II proposal, which was not granted, included the design and fabrication of an axially symmetric DC Gun with an inverted ceramic that would operate with less than 5 MV/m at 350 kV and would be designed with an in-situ replaceable photo-cathode.

43 PARTICLE ACCELERATORS↗

Analysis of HOM Problems in the C-ADS Main Linac

Excitation of higher-order modes (HOMs) in superconducting cavities may severely affect the operation of the main linac in the Chinese Accelerator Driven System (CADS). Preliminary analysis is made on the effects of beam dynamic, which includes possible longitudinal and transverse emittance enlargements, as well as the possibility of beam breakup. Suggestions are given for further investigation. Comparison is made between the C-ADS and the Fermilab Project X.

43 PARTICLE ACCELERATORS↗

Modeling of the amplified optical stochastic cooling experiment at IOTA

Optical Stochastic Cooling (OSC), a beam cooling technique based on Stochastic Cooling, is in the early stages of experimental development. It uses radiation produced by the beam in an undulator magnet (the pickup) to correct the momentum deviation of particles downstream in another undulator (the kicker). The OSC mechanism was recently demonstrated at Fermilab’s IOTA ring using a passive configuration. However, the cooling rate of OSC can be dramatically increased by first amplifying the undulator radiation before applying the corrective kick. In collaboration with the IOTA experiment, we developed a computational model of the OSC mechanism. This paper presents beam-dynamics simulations of the amplified-OSC configuration. We implement a model of intrabeam scattering and study the effects on beam equilibrium and diffusion rate as a function of bunch charge. Finally, we investigate the phase-space dynamics with various coupling configurations between the transverse and longitudinal planes.

43 PARTICLE ACCELERATORS↗

SU-E-T-358: Monte Carlo Dose Calculation of Small Field Electron Beams

Purpose: Dynamic radiotherapy involving electron beams such as Dynamic Electron Arc Radiotherapy (DEAR) requires accurate dose modelling of small field sizes, similar to the requirement of IMRT field on the small photon field. The current commercial electron Monte Carlo algorithms such as eMC v11 in Eclipse were developed for standard field sizes and do not support the planning of dynamic therapy yet. The purpose of this study is to develop a method to accurately model small field electron beam dosimetry using Monte Carlo simulations. Methods: Comparison between eMC, phantom measurements (diode), and Monte Carlo (MC) simulations (BEAMnrc/DOSYZnrc) were performed for a Varian TrueBeam linac. MC simulations utilized Varian TrueBeam phase space files which had been validated in another study. Static single small field was assessed by comparing dose distributions in water for a 16 MeV beam for circular (2 cm diameter) and rectangular (1×10 cm{sup 2}) cut-out. MC was performed with a resolution of 2.5×2.5×2 mm{sup 2} and statistical uncertainty < 4%. The dose distribution was averaged over adjacent bins to improve precision. Depth dose and orthogonal profiles were evaluated. Results: Small field PDDs differ from those with standard cones. For both circular and rectangular cutouts, the difference in range R8 0-R1 0 is less than 2 mm and in dose within 2%. For the orthogonal profiles, field size and penumbra differences were within 1 mm at depth of maximum dose. The eMC displayed a distinctive “step” in the out-field dose profile in disagreement with both measurement and MC results and needs further investigation. Conclusion: MC was able to characterize the small field dosimetry with good agreement with the measurement data, and thus offers the opportunity for treatment planning of dynamic radiotherapy. Analyses for all other electron energies and cut-out sizes are under way and results will be included in the presentation.

07 ISOTOPE AND RADIATION SOURCES↗

Laser Wakefield Acceleration Experiments Using HERCULES Laser

Laser wakefield acceleration (LWFA) in a supersonic gas-jet using a self-guided laser pulse was studied by changing laser power and plasma electron density. The recently upgraded HERCULES laser facility equipped with wavefront correction enables a peak intensity of 6.1x10{sup 19} W/cm{sup 2} at laser power of 80 TW to be delivered to the gas-jet using F/10 focusing optics. We found that electron beam charge was increased significantly with an increase of laser power from 30 TW to 80 TW and showed density threshold behavior at a fixed laser power. We also studied the influence of laser focusing conditions by changing the f-number of the optics to F/15 and found an increase in density threshold for electron production compared to the F/10 configuration. The analysis of different phenomena such as betatron motion of electrons, side scattering of the laser pulse for different focusing conditions, the influence of plasma density down ramp on LWFA are shown.

43 PARTICLE ACCELERATORS↗

X-ray Free-electron Lasers

We review the present status and properties of X-ray free-electron lasers in operation or under construction in the nanometer and sub-nanometer wavelength range, and the novel possibilities they offer for the study of atomic and molecular processes. We also discuss recent developments in relativistic electron beam physics that give us the possibility of designing a new generation of X-ray free-electron lasers that: a. are more compact; b. reduce the radiation pulse duration to one femtosecond or below; c. extend the photon energy to the 50 keV region. These results are obtained by reducing the electron bunch charge while at same time maximizing the beam brightness and reducing the bunch length to a value near or smaller than the free-electron laser cooperation length. In the last case the radiation pulse is fully coherent in the longitudinal and transverse space. The increase in beam brightness can also be used to reduce the beam energy needed for a given radiation wavelength, when, at the same time, the undulator period is reduced. The simultaneous decrease in beam energy and undulator period leads to a more compact free-electron laser, while the high beam brightness reduces the gain length and increases the coherent radiation intensity.

43 PARTICLE ACCELERATORS↗

THz pulses from 4th generation X-ray light sources: Perspectives for fully synchronized THz pump X-ray probe experiments

In this paper the prospects of terahertz (THz) pulses generated at 4th generation X-ray light sources are presented on the example of recent results from a prototype set-up at the soft X-ray FEL FLASH. It is shown, that the THz pulses from the relativistic ultra short electron bunches have unique properties, that at FLASH are utilized for novel THz pump X-ray probe experiments with a robust few fs resolution. Based on these experiences it is discussed, how future facilities can benefit from implementation of similar or further improved instrumentation.

43 PARTICLE ACCELERATORS↗

IR and THz Beamlines at the Metrology Light Source of the PTB

The low-energy electron storage ring Metrology Light Source (MLS), a dedicated synchrotron radiation source, is in user operation since April 2008. As a special option it provides coherent synchrotron radiation (CSR) in the THz range when it is operated in a low-alpha mode with short electron bunches. At the MLS three beamlines dedicated to the use of IR and THz radiation were designed, built and commissioned.

43 PARTICLE ACCELERATORS↗

Controlling the betatron oscillations of a wakefield-accelerated electron beam by temporally asymmetric laser pulses

Based on two-dimensional particle-in-cell simulations, we investigated the electron beam's transverse oscillations by temporally asymmetric laser pulses in laser wakefield acceleration. Of particular interest in this article are the effects of ultrashort laser pulses having sharp rising and slow falling time scales. In this situation, the accelerated electron beam interacts directly with the laser field and undergoes transverse oscillations due to a phase-slip with the laser field. This oscillation can be matched with the betatron oscillation due to the focusing force of the ions, which can lead to a large transverse oscillation amplitude due to the resonance between them. Furthermore, in this case, the electron beam can be microbunched at the laser wavelength, which may provide the possibility for generation of a coherent synchrotron radiation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic evolution of ultracold electron beams from nanostructured cathodes

Dynamic Coulomb expansion of dense, nonuniform particle beamlets can lead to causticlike formations in the charge density profile of the resultant beam. Such features only occur for cold beams where thermal diffusion of the particles is minimized. These phenomena have been observed experimentally for select cases with ion beams but not yet for electron beams as the electron dynamics occur over far faster timescales. We simulate the interaction of electron bunches while varying the initial transverse temperature and density profiles to determine the thresholds that characterize this pattern formation. Furthermore, we extend the simulations to geometric arrangements that are more pertinent to the nanotip cathode application and consider the effects of asymmetries and the impact of a low-density halo on the overall process. The simulations are conducted using a previously documented high-fidelity algorithm for collisional particle dynamics. These studies identify the temperature and density thresholds required for caustic formation and provide guidance for optimizing the design of nanoscale structured cathodes. We also demonstrate that the correlation between the final density patterns and the underlying beam parameters enables a virtual diagnostic tool for measuring ultralow emittance beams solely based on a transverse charge density profile.

43 PARTICLE ACCELERATORS↗

MULTI-OBJECTIVE ONLINE OPTIMIZATION OF BEAM LIFETIME AT APS

In this paper, online optimization of beam lifetime at the APS (Advanced Photon Source) storage ring is presented. A general genetic algorithm (GA) is developed and employed for some online optimizations in the APS storage ring. Sextupole magnets in 40 sectors of the APS storage ring are employed as variables for the online nonlinear beam dynamics optimization. The algorithm employs several optimization objectives and is designed to run with topup mode or beam current decay mode. Up to 50\% improvement of beam lifetime is demonstrated, without affecting the transverse beam sizes and other relevant parameters. In some cases, the top-up injection efficiency is also improved.

APS↗

APS-U LATTICE DESIGN FOR OFF-AXIS ACCUMULATION

A 67-pm hybrid-seven-bend achromat (H7BA) lattice is being proposed for a future Advanced Photon Source (APS) multi-bend-achromat (MBA) upgrade project. This lattice design pushes for smaller emittance and requires use of a swap-out (on-axis) injection scheme due to limited dynamic acceptance. Alternate lattice design work has also been performed for the APS upgrade to achieve better beam dynamics performance than the nominal APS MBA lattice, in order to allow off-axis accumulation. Two such alternate H7BA lattice designs, which target a still-low emittance of 90 pm, are discussed in detail in this paper. Although the single-particle-dynamics performance is good, simulations of collective effects indicate that surprising difficulty would be expected accumulating high single-bunch charge in this lattice. The brightness of the 90-pm lattice is also a factor of two lower than the 67-pm H7BA lattice.

APS-U↗

Simulations of space charge neutralization in a magnetized electron cooler

Magnetized electron cooling at relativistic energies and Ampere scale current is essential to achieve the proposed ion luminosities in a future electron-ion collider (EIC). Neutralization of the space charge in such a cooler can significantly increase the magnetized dynamic friction and, hence, the cooling rate. The Warp framework is being used to simulate magnetized electron beam dynamics during and after the build-up of neutralizing ions, via ionization of residual gas in the cooler. The design follows previous experiments at Fermilab as a verification case. We also discuss the relevance to EIC designs.

Gerity, James↗

Dynamics of a high-current relativistic electron beam

The dynamics of a high-current relativistic electron beam is studied experimentally and by numerical simulation. The beam is formed in a magnetically insulated diode with a transverse-blade explosive-emission cathode. It is found experimentally that the radius of a 500-keV beam with a current of 2 kA and duration of 500 ns decreases with time during the beam current pulse. The same effect was observed in numerical simulations. This effect is explained by a change in the shape of the cathode plasma during the current pulse, which, according to calculations, leads to a change in the beam parameters, such as the electron pitch angle and the spread over the longitudinal electron momentum. These parameters are hard to measure experimentally; however, the time evolution of the radial profile of the beam current density, which can be measured reliably, coincides with the simulation results. This allows one to expect that the behavior of the other beam parameters also agrees with numerical simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-305: Clinical Effects of Dosimetric Leaf Gap (DLG) Values Between Matched Varian Truebeam (TB) Linacs

Purpose: The dosimetric leaf gap (DLG) is an important parameter to be measured for dynamic beam delivery of modern linacs, like the Varian Truebeam (TB). The clinical effects of DLG-values on IMRT and/or VMAT commissioning of two “matched” TB linacs will be presented.Methods and Materials: The DLG values on two TB linacs were measured for all energy modalities (filtered and FFF-modes) as part of the dynamic delivery mode commissioning (IMRT and/or VMAT. After the standard beam data was modeled in eclipse treatment planning system (TPS) and validated, IMRT validation was performed based on TG1191 benchmark, IROC Head-Neck (H&N) phantom and sample of clinical cases, all measured on both linacs. Although there was a single-set of data entered in the TPS, a noticeable difference was observed for the DLG-values between the linacs. The TG119, IROC phantom and selected patient plans were furnished with DLG-values of TB1 for both linacs and the delivery was performed on both TB linacs for comparison. Results: The DLG values of TB1 was first used for both linacs to perform the testing comparisons. The QA comparison of TG119 plans revealed a great dependence of the results to the DLG-values used for the linac for all energy modalities studied, especially when moving from 3%/3mm to 2%/2mm γ-analysis. Conclusion: The DLG-values have a definite influence on the dynamic dose, delivery that increases with the plan complexity. We recommend that the measured DLG-values are assigned to each of the “matched” linacs, even if a single set of beam data describes multiple linacs. The user should perform a detail test of the dynamic delivery of each linac based on end-to-end benchmark suites like TG119 and IROC phantoms.1Ezzel G., et al., “IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119.” Med. Phys. 36:5359–5373 (2009). partly supported by CAMC Cancer Center and Alliance Oncology.

60 APPLIED LIFE SCIENCES↗

Phase-Space Manipulation of Ultracold Ion Bunches with Time-Dependent Fields

All applications of high brightness ion beams depend on the possibility to precisely manipulate the trajectories of the ions or, more generally, to control their phase-space distribution. We show that the combination of a laser-cooled ion source and time-dependent acceleration fields gives new possibilities to perform precise phase-space control. We demonstrate reduction of the longitudinal energy spread and realization of a lens with control over its focal length and sign, as well as the sign of the spherical aberrations. This creates new possibilities to correct for the spherical and chromatic aberrations which are presently limiting the spatial resolution.

43 PARTICLE ACCELERATORS↗