Laser damage by ns and sub-ps pulses on hafnia/silica anti-reflection coatings on fused silica double-sided polished using zirconia or ceria and washed with or without an alumina wash step.

Sandia's Large Optics Coating Operation has extensive results of laser induced damage threshold (LIDT) testing of its anti-reflection (AR) and high reflection coatings on substrates pitch polished using ceria and washed in a process that includes an alumina wash step. The purpose of the alumina wash step is to remove residual polishing compound to minimize its role in laser damage. These LIDT tests are for multi longitudinal mode, ns class pulses at 1064 nm and 532 nm (NIF-MEL protocol) and mode locked, sub-ps class pulses at 1054 nm (Sandia measurements), and show reasonably high and adequate laser damage resistance for coatings in the beam trains of Sandia's Z-Backlighter terawatt and petawatt lasers. An AR coating in addition to coatings of our previous reports confirms this with LIDTs of 33.0 J/cm{sup 2} for 3.5 ns pulses and 1.8 J/cm{sup 2} for 350 fs pulses. In this paper, we investigate both ceria and zirconia in doublesided polishing (common for large flat Z-Backlighter laser optics) as they affect LIDTs of an AR coating on fused silica substrates washed with or without the alumina wash step. For these AR coated, double-sided polished surfaces, ceria polishing in general affords better resistance to laser damage than zirconia polishing and laser damage is less likely with the alumina wash step than without it. This is supported by specific results of laser damage tests with 3.5 ns, multi longitudinal mode, single shot pulses at 1064 nm and 532 nm, with 7.0 ns, single and multi longitudinal mode, single and multi shot pulses at 532 nm, and with 350 fs, mode-locked, single shot pulses at 1054 nm.

36 MATERIALS SCIENCE↗

Universal Common Communication Substrate (UCCS) Specification; Universal Common Communication Substrate (UCCS) Implementation

Universal Common Communication Substrate (UCCS) is a low-level communication substrate that exposes high-performance communication primitives, while providing network interoperability. It is intended to support multiple upper layer protocol (ULPs) or programming models including SHMEM,UPC,Titanium,Co-Array Fortran,Global Arrays,MPI,GASNet, and File I/O. it provides various communication operations including one-sided and two-sided point-to-point, collectives, and remote atomic operations. In addition to operations for ULPs, it provides an out-of-band communication channel required typically required to wire-up communication libraries.

Source record↗

BDS thin film damage competition

A laser damage competition was held at the 2008 Boulder Damage Symposium in order to determine the current status of thin film laser resistance within the private, academic, and government sectors. This damage competition allows a direct comparison of the current state-of-the-art of high laser resistance coatings since they are all tested using the same damage test setup and the same protocol. A normal incidence high reflector multilayer coating was selected at a wavelength of 1064 nm. The substrates were provided by the submitters. A double blind test assured sample and submitter anonymity so only a summary of the results are presented here. In addition to the laser resistance results, details of deposition processes, coating materials, and layer count will also be shared.

42 ENGINEERING↗

Verification of Maximal Oxygen Uptake in Active Military Personnel During Treadmill Running

Figueiredo, PS, Looney, DP, Pryor, JL, Doughty, EM, McClung, HL, Vangala, SV, Santee, WR, Beidleman, BA, and Potter, AW. Verification of maximal oxygen uptake in active military personnel during treadmill running. J Strength Cond Res 36(4): 1053–1058, 2022—It is unclear whether verification tests are required to confirm “true” maximal oxygen uptake ($\dot{V}_{o2}$max) in modern warfighter populations. Our study investigated the prevalence of $\dot{V}_{o2}$max attainment in U.S. Army soldiers performing a traditional incremental running test. In addition, we examined the utility of supramaximal verification testing as well as repeated trials for familiarization for accurate $\dot{V}_{o2}$max assessment. Sixteen U.S. Army soldiers (1 woman, 15men; age, 21±2 years; height, 1.73±0.06m; body mass, 71.6±10.1 kg) completed 2 laboratory visits, each with an incremental running test (modified Astrand protocol) and a verification test (110% maximal incremental test speed) on a motorized treadmill. We evaluated $\dot{V}_{o2}$max attainment during incremental testing by testing for the definitive $\dot{V}_{o2}$ plateau using a linear least-squares regression approach. Peak oxygen uptake ($\dot{V}_{o2}$peak) was considered statistically equivalent between tests if the 90% confidence interval around the mean difference was within 62.1 ml·kg -1 ·min -1 . Oxygen uptake plateaus were identified in 14 of 16 volunteers for visit 1 (87.5%) and all 16 volunteers for visit 2 (100%). Peak oxygen uptake was not statistically equivalent, apparent from the mean difference in $\dot{V}_{o2}$peak measures between the incremental test and verification test on visit 1 (2.3 ml·kg -1 ·min -1 , [1.3–3.2]) or visit 2 (1.1 ml·kg -1 ·min -1 [0.2–2.1]). Interestingly, $\dot{V}_{o2}$peak was equivalent, apparent from the mean difference in $\dot{V}_{o2}$peak measures between visits for the incremental tests (0.0ml·kg -1 ·min -1 [-0.8to 0.9]) but not the verification tests (-1.2 ml·kg -1 ·min -1 [-2.2 to -0.2]). Modern U.S. Army soldiers can attain $\dot{V}_{o2}$max by performing a modified Astrand treadmill running test. Additional familiarization and verification tests for confirming $\dot{V}_{o2}$max in healthy active military personnel may be unnecessary.

60 APPLIED LIFE SCIENCES↗

Sensitivity of Induced Seismic Sequences to Rate-and-State Frictional Processes

It is well established that subsurface injection of fluids increases pore fluid pressures that may lead to shear failure along a preexisting fault surface. Concern among oil and gas, geothermal, and carbon storage operators has risen dramatically over the past decade due to the increase in the number and magnitude of induced earthquakes. Efforts to mitigate the risk associated with injection-induced earthquakes include modeling of the interaction between fluids and earthquake faults. Here we investigate this relationship with simulations that couple a geomechanical reservoir model and RSQSim, a physics-based earthquake simulator. RSQSim employs rate- and state-dependent friction (RSF) that enables the investigation of the time-dependent nature of earthquake sequences. We explore the effect of two RSF parameters and normal stress on the spatiotemporal characteristics of injection-induced seismicity. We perform >200 simulations to systematically investigate the effect of these model components on the evolution of induced seismicity sequences and compare the spatiotemporal characteristics of our synthetic catalogs to observations of induced earthquakes. We find that the RSF parameters control the ability of seismicity to migrate away from the injection well, the total number and maximum magnitude of induced events. Additionally, the RSF parameters control the occurrence/absence of premonitory events. Finally, we find that earthquake stress drops can be modulated by the normal stress and/or the RSF parameters. Insight gained from this study can aid in further development of models that address best practice protocols for injection operations, site-specific models of injection-induced earthquakes, and probabilistic hazard and risk assessments.

58 GEOSCIENCES↗

Methods for Carbon Mass Closure in Polyolefin Hydrocracking

Heterogeneous catalytic hydrocracking of polyolefins is a promising approach for the processing of postconsumer plastics, but product quantification methods remain inconsistent across the literature. In systems that generate a large fraction of vapor-phase products, typical product capture methods can result in large carbon balance deficits, exceeding 50%, compromising reported yields and selectivities. Here, we identify the major sources of product loss and develop enhanced capture methods to improve the quantification accuracy. Seven supplemental techniques were evaluated, targeting either increased vapor recovery (by increasing the volatility or system volume) or enhanced retention in the liquid phase (by decreasing volatility). Among these, a flow collection approach using a continuous helium sweep and downstream gas sampling bag capture yielded the highest recovery, achieving a 96 ± 9.2% carbon balance closure. We show that the efficacy of these methods is strongly dependent on product distribution. In general, solvent addition was most effective when condensable species dominate the product distribution, while flow collection was preferred when both condensable species and light gases are present in high concentrations. These results highlight the need for method-specific workup strategies and demonstrate that no single protocol is universally optimal. We provide general guidelines for selecting and implementing robust product capture techniques, enabling accurate yield and selectivity determinations in polyolefin hydrocracking systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Certified randomness using a trapped-ion quantum processor

Although quantum computers can perform a wide range of practically important tasks beyond the abilities of classical computers, realizing this potential remains a challenge. An example is to use an untrusted remote device to generate random bits that can be certified to contain a certain amount of entropy. Certified randomness has many applications but is impossible to achieve solely by classical computation. Here we demonstrate the generation of certifiably random bits using the 56-qubit Quantinuum H2-1 trapped-ion quantum computer accessed over the Internet. Our protocol leverages the classical hardness of recent random circuit sampling demonstrations: a client generates quantum ‘challenge’ circuits using a small randomness seed, sends them to an untrusted quantum server to execute and verifies the results of the server. We analyse the security of our protocol against a restricted class of realistic near-term adversaries. Using classical verification with measured combined sustained performance of 1.1 × 10 18 floating-point operations per second across multiple supercomputers, we certify 71,313 bits of entropy under this restricted adversary and additional assumptions. Our results demonstrate a step towards the practical applicability of present-day quantum computers.

computer science↗

Quantum Kolmogorov complexity and bounded quantum memory

The effect of bounded quantum memory in a primitive information protocol has been examined using the quantum Kolmogorov complexity as a measure of information. We employed a toy two-party protocol in which Bob, by using a bounded quantum memory and an unbounded classical memory, estimates a message that was encoded in qubits by Alice in one of the bases X or Z. Our theorem gave a nontrivial effect of the memory boundedness. In addition, a generalization of the uncertainty principle in the presence of quantum memory has been obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of a free-running synchronization artifact correction for MV-imaging with aSi:H flat panels

Purpose: Solid state flat panel electronic portal imaging devices (EPIDs) are widely used for megavolt (MV) photon imaging applications in radiotherapy. In addition to their original purpose in patient position verification, they are convenient to use in quality assurance and dosimetry to verify beam geometry and dose deposition or to perform linear accelerator (linac) calibration procedures. However, native image frames from amorphous silicon (aSi:H) detectors show a range of artifacts which have to be eliminated by proper correction algorithms. When a panel is operated in free-running frame acquisition mode, moving vertical stripes (periodic synchronization artifacts) are a disturbing feature in image frames. Especially for applications in volumetric intensity modulated arc therapy (VMAT) or motion tracking, the synchronization (sync) artifacts are the limiting factor for potential and accuracy since they become even worse at higher frame rates and at lower dose rates, i.e., linac pulse repetition frequencies (PRFs). Methods: The authors introduced a synchronization correction method which is based on a theoretical model describing the interferences of the panel's readout clocking with the linac's dose pulsing. Depending on the applied PRF, a certain number of dose pulses is captured per frame which is readout columnwise, sequentially. The interference of the PRF with the panel readout is responsible for the period and the different gray value levels of the sync stripes, which can be calculated analytically. Sync artifacts can then be eliminated multiplicatively in precorrected frames without additional information about radiation pulse timing. Results: For the analysis, three aSi:H EPIDs of various types were investigated with 6 and 15 MV photon beams at varying PRFs of 25, 50, 100, 200, and 400 pulses per second. Applying the sync correction at panels with gadolinium oxysulfide scintillators improved single frame flood field image quality drastically [improvement of the signal-to-noise ratio (SNR) up to 66.1 dB for 6 MV and 66.0 dB for 15 MV]. Also for the EPID with a caesium iodide scintillator, the noise for the lower PRFs could be reduced (SNR at 6 MV of up to 56.3 dB and at 15 MV up to 46.7 dB). However, the simplistic readout interference model fails at higher PRFs, where image lag and ghosting effects due to trapped charges in the thin film transistor and scintillator postglowing require additional corrections. Conclusions: The presented free-running sync correction method improves SNR of single frames and enables imaging applications, like low-dose rate imaging at increased image frame rates (e.g., to track moving gold fiducials in the lung). Adaptive image guided radiotherapy protocols become even feasible in VMAT plans. Also simultaneous kilovolt and MV imaging applications can benefit from new possibilities of MV scatter removal in x-ray images.

60 APPLIED LIFE SCIENCES↗

SU-G-206-08: How Should Focal Spot Be Chosen for Optimized CT Imaging with Dose Modulation?

Purpose: To choose the preferred focal spot for achieving optimized CT image quality with balanced tube heating considerations. Methods: An anthropomorphic pelvic phantom was scanned using a GE Discovery CT750 HD at 120 and 140kVp, 0.8s rotation time, and pitch of 0.984. “Smart mA” was enabled to simulate a routine abdomen–pelvis CT scan. Permissible mA values at 120 and 140 kVp were obtained from the Serial Load Rating table (for mimicking a busy CT clinical operation) in the scanner Technical Reference Manual. At each kVp station and two Noise Index levels, the mA Upper Limit was set above/below the permissible mA values. Scanned mA values and focal spot (FS) used were obtained from the DICOM header of each image, and the FS-mA relationship was analyzed. For visual confirmation beyond recorded FS information, a CatPhan with a fat-ring attached for mimicking patient size/shape was scanned at 120kVp. A group of radiologists/physicists compared a pair of CatPhan images qualitatively. Lastly, a number of patient cases were evaluated to confirm the FS-mA relationship. Results: When preset Upper Limit values were above the permissible mA values, the Large FS (labeled 1.2) was used in scans, even if the maximum scanned mA values were much lower than the permissible values at both 120 and 140 kVp. Otherwise the Small FS (labeled 0.7) was used. Visual evaluation of the high contrast module of CatPhan and additional analysis of patient cases further confirmed that the preset Upper Limit determines which focal spot is to be used, not the actual maximum mA value to be scanned. Conclusion: Specific FS can be selected by setting up appropriate mA Upper Limit in a protocol. CT protocols could be optimized by selecting appropriate FS for improving patient image quality, especially benefiting the small size and pediatric patients.

60 APPLIED LIFE SCIENCES↗

Towards long-term standardised carbon and greenhouse gas observations for monitoring Europe’s terrestrial ecosystems: A review

Research infrastructures play a key role in launching a new generation of integrated long-term, geographically distributed observation programmes designed to monitor climate change, better understand its impacts on global ecosystems, and evaluate possible mitigation and adaptation strategies. The pan-European Integrated Carbon Observation System combines carbon and greenhouse gas (GHG; CO 2 , CH 4 , N 2 O, H 2 O) observations within the atmosphere, terrestrial ecosystems and oceans. High-precision measurements are obtained using standardised methodologies, are centrally processed and openly available in a traceable and verifiable fashion in combination with detailed metadata. The Integrated Carbon Observation System ecosystem station network aims to sample climate and land-cover variability across Europe. In addition to GHG flux measurements, a large set of complementary data (including management practices, vegetation and soil characteristics) is collected to support the interpretation, spatial upscaling and modelling of observed ecosystem carbon and GHG dynamics. The applied sampling design was developed and formulated in protocols by the scientific community, representing a trade-off between an ideal dataset and practical feasibility. Finally, the use of open-access, high-quality and multi-level data products by different user communities is crucial for the Integrated Carbon Observation System in order to achieve its scientific potential and societal value.

54 ENVIRONMENTAL SCIENCES↗

A flexible framework for secure and efficient program obfuscation.

In this paper, we present a modular framework for constructing a secure and efficient program obfuscation scheme. Our approach, inspired by the obfuscation with respect to oracle machines model of [4], retains an interactive online protocol with an oracle, but relaxes the original computational and storage restrictions. We argue this is reasonable given the computational resources of modern personal devices. Furthermore, we relax the information-theoretic security requirement for computational security to utilize established cryptographic primitives. With this additional flexibility we are free to explore different cryptographic buildingblocks. Our approach combines authenticated encryption with private information retrieval to construct a secure program obfuscation framework. We give a formal specification of our framework, based on desired functionality and security properties, and provide an example instantiation. In particular, we implement AES in Galois/Counter Mode for authenticated encryption and the Gentry-Ramzan [13]constant communication-rate private information retrieval scheme. We present our implementation results and show that non-trivial sized programs can be realized, but scalability is quickly limited by computational overhead. Finally, we include a discussion on security considerations when instantiating specific modules.

Solis, John Hector↗

RESULTS FROM A DEMONSTRATION OF RF-BASED UF6 CYLINDER ACCOUNTING AND TRACKING SYSTEM INSTALLED AT A USEC FACILITY

Approved industry-standard cylinders are used globally for storing and transporting uranium hexafluoride (UF{sub 6}) at uranium enrichment plants and processing facilities. To verify that no diversion or undeclared production of nuclear material involving UF{sub 6} cylinders at the facility has occurred, the International Atomic Energy Agency (IAEA) conducts periodic, labor-intensive physical inspections to validate facility records, cylinder identities, and cylinder weights. A reliable cylinder monitoring system that would improve overall inspector effectiveness would be a significant improvement to the current international safeguards inspection regime. Such a system could include real-time unattended monitoring of cylinder movements, situation-specific rules-based event detection algorithms, and the capability to integrate with other types of safeguards technologies. This type of system could provide timely detection of abnormal operational activities that may be used to ensure more appropriate and efficient responses by the IAEA. A system of this type can reduce the reliance on paper records and have the additional benefit of facilitating domestic safeguards at the facilities at which it is installed. A radio-frequency (RF)-based system designed to track uranium hexafluoride (UF{sub 6}) cylinders during processing operations was designed, assembled, and tested at the United States Enrichment Corporation (USEC) facility in Portsmouth, Ohio, to determine the operational feasibility and durability of RF technology. The overall objective of the effort was to validate the robustness of RF technology for potential use as a future international safeguards tool for tracking UF6 cylinders at uranium-processing facilities. The results to date indicate that RF tags represent a feasible technique for tracking UF{sub 6} cylinders in operating facilities. Additional work will be needed to improve the operational robustness of the tags for repeated autoclave processing and to add tamper-indicating and data authentication features to some of the pertinent system components. Future efforts will focus on these needs along with implementing protocols relevant to IAEA safeguards. The work detailed in this report demonstrates the feasibility of constructing RF devices that can survive the operational rigors associated with the transportation, storage, and processing of UF6 cylinders. The system software specially designed for this project is called Cylinder Accounting and Tracking System (CATS). This report details the elements of the CATS rules-based architecture and its use in safeguards-monitoring and asset-tracking applications. Information is also provided on improvements needed to make the technology ready, as well as options for improving the safeguards aspects of the technology. The report also includes feedback from personnel involved in the testing, as well as individuals who could utilize an RF-based system in supporting the performance of their work. The system software was set up to support a Mailbox declaration, where a declaration can be made either before or after cylinder movements take place. When the declaration is made before cylinders move, the operators must enter this information into CATS. If the IAEA then shows up unexpectedly at the facility, they can see how closely the operational condition matches the declaration. If the declaration is made after the cylinders move, this provides greater operational flexibility when schedules are interrupted or are changed, by allowing operators to declare what moves have been completed. The IAEA can then compare where cylinders are with where CATS or the system says they are located. The ability of CATS to automatically generate Mailbox declarations is seen by the authors as a desirable feature. The Mailbox approach is accepted by the IAEA but has not been widely implemented (and never in enrichment facilities). During the course of this project, we have incorporated alternative methods for implementation.

Pickett, Chris A↗

RoboCount{sup TM} 2020 - A Robotic Non-Destructive Waste Assay System - 19331

A robotic system for non-destructive assay of radioactive waste - RoboCount{sup TM} 2020ab - has been designed, manufactured, and a prototype delivered to a customer. RoboCount{sup TM} 2020 is based on an industrial 6-axis articulating robot platform, combined with a dedicated waste package platform and a high-resolution HPGe gamma spectrometer. The system enables measurement of waste packages including drums (100-l, 200-l, 400-l), crates (up to 1200 x 800 x 800 mm), 1 m{sup 3} flexible intermediate bulk containers (FIBC), and others. Assay type can be freely defined, ranging from currently accepted protocols such as segmented gamma scan (SGS) or integral gamma scan (IGS) to new protocols developed for specific non-cylindrical waste packages, e.g., measurement of FIBCs from all four sides and the top. As a result of the robotic hardware flexibility, reconfiguration of the system for a new task is a matter of software changes only. In addition, while primarily geared towards waste characterization, the system can be configured for free release (clearance) by installing a second detector and field-of-view shielding. The prototype is currently in operation at a NPP site in Europe where it is used for D and D waste characterization in crates and FIBCs. Additional features beyond the basic functionality have been implemented such as an automatic lead collimator change based on measured HPGe detector dead time and an automatic liquid nitrogen refill, performed by the robot via a docking station at predefined time intervals. (Use of electrically cooled HPGe detectors is also possible). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optically levitating dielectrics in the quantum regime: Theory and protocols

We provide a general quantum theory to describe the coupling of light with the motion of a dielectric object inside a high-finesse optical cavity. In particular, we derive the total Hamiltonian of the system as well as a master equation describing the state of the center-of-mass mode of the dielectric and the cavity-field mode. In addition, a quantum theory of elasticity is used to study the coupling of the center-of-mass motion with internal vibrational excitations of the dielectric. This general theory is applied to the recent proposal of using an optically levitating nanodielectric as a cavity optomechanical system [see Romero-Isart et al., New J. Phys. 12, 033015 (2010); Chang et al., Proc. Natl. Acad. Sci. USA 107, 1005 (2010)]. On this basis, we also design a light-mechanics interface to prepare non-Gaussian states of the mechanical motion, such as quantum superpositions of Fock states. Finally, we introduce a direct mechanical tomography scheme to probe these genuine quantum states by time-of- flight experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Blunt Chest Trauma: A Radiologic Approach and Review

Blunt chest trauma, a frequent component of trauma admissions, is the second leading cause of death in motor-vehicle accidents. Additionally, it may be associated with significant morbidity in those who survive. Radiography, ultrasonography, and computed tomography (CT) have a widespread role in evaluating blunt chest trauma, importantly aiding in the diagnosis and management of injury. Herein, we discuss the most common salient injuries, imaging protocol considerations and imaging findings associated with acute blunt chest trauma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of the ChIMES Force Field to Nonreactive Molecular Systems: Water at Ambient Conditions

We demonstrate development of the Chebyshev Interaction Model for Efficient Simulation (ChIMES) for molecular systems through application to water under ambient conditions (298 K, 1 g/cm 3 ). These models, which are comprised of linear combinations of Chebyshev polynomials explicitly describing two- and three-body interactions, are largely fit by force matching to Kohn–Sham Density Functional Theory (DFT). Protocols for selecting user-specified parameters and inclusion of stress tensor data are investigated, and structural and dynamical property prediction for resulting models is benchmarked against DFT. We show that the present ChIMES force fields yield excellent agreement with DFT without the need for additional terms such as those for Coulomb interactions. Overall, we show that tractable parametrization and subsequent accuracy of the present models make ChIMES an ideal candidate for extension of DFT dynamics to larger system sizes and longer time scales.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High resolution ENDOR spectroscopy combined with quantum chemical calculations reveals the structure of the nitrogenase Janus intermediate E4(4H)

We have shown that the key state in N2 reduction to two NH3 by the enzyme nitrogenase is the E4(4H), ‘Janus’ intermediate, which has accumulated four [e-/H+] and is poised to undergo reductive elimination of H2 coupled to N2 binding and activation. Initial 1H and 95Mo ENDOR studies of freeze-trapped E4(4H) revealed the catalytic multi-metallic cluster (FeMo-co) binds two Fe-bridging hydrides, [Fe-H-Fe]. However, the analysis failed to provide a satisfactory picture of structure - the relative spatial relationships of the two [Fe-H-Fe]. Our recent density functional theory (DFT) study yielded a lowest-energy form, denoted E4(4H)(a), with two parallel Fe-H-Fe planes bridging pairs of ‘anchor’ Fe on the Fe2,3,6,7 face of FeMo-co. However, the relative energies of structures E4(4H)(b), with one bridging and one terminal hydride, and E4(4H)(c), with one pair of anchor Fe supporting two bridging hydrides, were not beyond the uncertainties of the calculation. Moreover, a structure of V-dependent nitrogenase resulted in a proposed structure analogous to E4(4H)(c), and additional structures have been proposed by DFT studies of others. To resolve the nature of hydride binding to the Janus intermediate, we performed exhaustive, high-resolution CW-stochastic 1H-ENDOR experiments using improved instrumentation, Mims 2H ENDOR, and a pulsed-ENDOR protocol (‘PESTRE’) to obtain absolute hyperfine-interaction signs. These measurements are coupled to DFT structural models through an analytical point-dipole Hamiltonian for the hydride electron-nuclear dipolar coupling to its ‘anchoring’ Fe ions, an approach that overcomes limitations inherent in both experimental interpretation and computational accuracy. The result: the freeze-trapped, lowest-energy Janus intermediate structure is E4(4H)(a).

Hoeke, Veronica↗