Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acceptance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

SU-F-J-23: Field-Of-View Expansion in Cone-Beam CT Reconstruction by Use of Prior Information

Purpose: Cone-beam CT (CBCT) has become an integral part of online patient setup in an image-guided radiation therapy (IGRT). In addition, the utility of CBCT for dose calculation has actively been investigated. However, the limited size of field-of-view (FOV) and resulted CBCT image with a lack of peripheral area of patient body prevents the reliability of dose calculation. In this study, we aim to develop an FOV expanded CBCT in IGRT system to allow the dose calculation. Methods: Three lung cancer patients were selected in this study. We collected the cone-beam projection images in the CBCT-based IGRT system (X-ray volume imaging unit, ELEKTA), where FOV size of the provided CBCT with these projections was 410 × 410 mm{sup 2} (normal FOV). Using these projections, CBCT with a size of 728 × 728 mm{sup 2} was reconstructed by a posteriori estimation algorithm including a prior image constrained compressed sensing (PICCS). The treatment planning CT was used as a prior image. To assess the effectiveness of FOV expansion, a dose calculation was performed on the expanded CBCT image with region-of-interest (ROI) density mapping method, and it was compared with that of treatment planning CT as well as that of CBCT reconstructed by filtered back projection (FBP) algorithm. Results: A posteriori estimation algorithm with PICCS clearly visualized an area outside normal FOV, whereas the FBP algorithm yielded severe streak artifacts outside normal FOV due to under-sampling. The dose calculation result using the expanded CBCT agreed with that using treatment planning CT very well; a maximum dose difference was 1.3% for gross tumor volumes. Conclusion: With a posteriori estimation algorithm, FOV in CBCT can be expanded. Dose comparison results suggested that the use of expanded CBCTs is acceptable for dose calculation in adaptive radiation therapy. This study has been supported by KAKENHI (15K08691).

60 APPLIED LIFE SCIENCES↗

Community Response to Concentrating Solar Power in the San Luis Valley: October 9, 2008 - March 31, 2010

This report is about the social acceptance of utility-scale concentrating solar power (CSP) plants in the San Luis Valley, approximately 200 miles southwest of Denver, Colorado. The research focused on social factors that may facilitate and impede the adoption and implementation of CSP. During the winter of 2008-2009, interviews were conducted with a purposive sample of 25 CSP-related stakeholders inside and outside the Valley. Interviews focused on the perceived advantages and disadvantages of siting a hypothetical 100-MW CSP facility in the Valley, the level of community support and opposition to CSP development, and related issues, such as transmission. State policy recommendations based on the findings include developing education programs for Valley residents, integrating Valley decision makers into an energy-water-land group, providing training for Valley decision makers, offering workforce training, evaluating models of taxation, and forming landholder energy associations. In addition, the SLV could become a laboratory for new approaches to CSP facility and transmission siting decision-making. The author recommends that outside stakeholders address community concerns and engage Valley residents in CSP decisions. Engaging the residents in CSP and transmission decisions, the author says, should take parallel significance with the investment in solar technology.

14 SOLAR ENERGY↗

Search for New Physics with a Dijet plus Missing Transverse Energy Signature in p-pbar Collisions at sqrt(s) = 1.96 TeV

We present results of a signature-based search for new physics using a dijet plus missing transverse energy (E{sub T}) data sample collected in 2 fb{sup -1} of p{bar p} collisions at {radical}s = 1.96 TeV with the CDF II detector at the Fermilab Tevatron. We observe no significant event excess with respect to the standard model prediction and extract a 95% C.L. upper limit on the cross section times acceptance for a potential contribution from a non-standard model process. Based on this limit the mass of a potential first or second generation scalar leptoquark is constrained to be above 187 GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling binary CO{sub 2}/CH{sub 4} flow through coal media

CO{sub 2} can be sequestered in coal seams considering the environmental issues. By means of injecting CO{sub 2} into the coal seams, both sequestration of CO{sub 2} and the enhanced recovery of methane inside the coal seam can be realized. One-dimensional simulation regarding the binary CO{sub 2}/CH{sub 4} flow in a coal seam core was studied by using an analytical solution method. The simulation results were compared with experimental data by matching the effluent concentrations of CO{sub 2} and CH{sub 4}. The transport parameters such as longitudinal dispersion coefficient, retardation factor, and distribution coefficient were determined. It was seen that the amount of CO{sub 2} captured inside the coal sample during binary displacement was much lower than the maximum adsorption capacity of the coal at the same pressure. Then the transport behavior of CO{sub 2} and CH{sub 4} inside the coal seam was simulated. The results of analytical solution were in good agreement with the measured ones within the acceptable error range.

01 COAL, LIGNITE, AND PEAT↗

Measurement of the top quark-antiquark pair charge asymmetry in events with highly boosted top quarks in proton-proton collisions at 13 TeV with the CMS detector

The top quark is the heaviest elementary particle, making it a unique tool to search for new physics. In this talk, I will present a new measurement of the top quark pair charge asymmetry for highly boosted top quarks decaying to a single lepton, missing transverse momentum and jets. The analysis is performed on 13TeV proton-proton collision data recorded by the CMS experiment during Run 2. We have defined a dedicated phase space that selects top quark-antiquark pairs with invariant mass greater than 750GeV in a semileptonic final state where the lepton is not necessarily isolated. This highly boosted sample is enhanced in valence quark production and thus expected to be more sensitive to deviations in the charge asymmetry caused by BSM processes. Dedicated tagging techniques are used to identify the decay products of hadronic top quarks and W bosons. An unfolding procedure is used to correct for detector resolution and acceptance, and inefficiencies in the event reconstruction. The result is presented in the full phase space at parton level and can be used as input to global EFT interpretations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of Precipitate Reactor Feed Tank (PRFT) Batches 15, 22, and 26 from the Defense Waste Processing Facility (DWPF)

The Savannah River Site (SRS) Defense Waste Processing Facility (DWPF) processes a Monosodium Titanate/Sludge Solids (MST/SS) waste stream received from the Salt Waste Processing Facility (SWPF) via the Precipitate Reactor Feed Tank (PRFT). During processing, DWPF is required to provide evidence of compliance with the Waste Acceptance Product Specifications (WAPS) to ensure acceptance of their vitrified high-level waste (HLW) into the Civilian Radioactive Waste Management System. Production Records must document the constituents of the MST/SS material in the PRFT from each salt batch (StB) processed at SWPF. Savannah River Mission Completion (SRMC) has requested Savannah River National Laboratory (SRNL) to analyze PRFT samples representing each SWPF salt batch for thirty-two radionuclides. Additionally, elemental analysis of PRFT slurry and MST/SS solids was performed to aid SRMC in further refinement of the inputs and assumptions used in future frit development and Material Tracking Program calculations. The analyses of PRFT Batches 15, 22, and 26, which corresponds to material from the processing of StB4, StB5, and StB7, respectively, are reported herein. The unwashed dried solids of the PRFT batches were found to be 86-87% MST. Additionally, the total sulfur values are well below the assumed 982 mg of sulfate/kg of PRFT slurry used in Material Tracking Program calculations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The U.S. national nuclear forensics library, nuclear materials information program, and data dictionary

Nuclear forensics assessments to determine material process history requires careful comparison of sample data to both measured and modeled nuclear material characteristics. Developing centralized databases, or nuclear forensics libraries, to house this information is an important step to ensure all relevant data will be available for comparison during a nuclear forensics analysis and help expedite the assessment of material history. The approach most widely accepted by the international community at this time is the implementation of National Nuclear Forensics libraries, which would be developed and maintained by individual nations. This is an attractive alternative toan international database since it provides an understanding that each country has data on materials produced and stored within their borders, but eliminates the need to reveal any proprietary or sensitive information to other nations. To support the concept of National Nuclear Forensics libraries, the United States Department of Energy has developed a model library, based on a data dictionary, or set of parameters designed to capture all nuclear forensic relevant information about a nuclear material. Specifically, information includes material identification, collection background and current location, analytical laboratories where measurements were made, material packaging and container descriptions, physical characteristics including mass and dimensions, chemical and isotopic characteristics, particle morphology or metallurgical properties, process history including facilities, and measurement quality assurance information. While not necessarily required, it may also be valuable to store modeled data sets including reactor burn-up or enrichment cascade data for comparison. It is fully expected that only a subset of this information is available or relevant to many materials, and much of the data populating a National Nuclear Forensics library would be process analytical or material accountability measurement data as opposed to a complete forensic analysis of each material in the library.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

RCRA Part B Permit Application Nevada National Security Site (NNSS) for Waste Management Activities at the NNSS Hazardous Waste Storage Unit (HWSU)

This volume of the permit application by the DOE’s National Nuclear Security Administration Nevada Field Office (NNSA/NFO) to the Nevada Division of Environmental Protection (NDEP) focuses on the Area 5 Hazardous Waste Storage Unit (HWSU). The HWSU was established to support testing, research, and remediation activities at the Nevada National Security Site (NNSS), a large-quantity generator of hazardous waste. The HWSU, located adjacent to the Area 5 Radioactive Waste Management Complex (RWMC), is a prefabricated, rigid steel-framed, roofed shelter used to store hazardous nonradioactive waste generated on the NNSS. No offsite-generated wastes are managed at the HWSU. Waste managed at the HWSU includes the following: Flammables/Combustibles, Acid Corrosives, Alkali Corrosives, Oxidizers/Reactives, Toxics/Poisons, and Other Regulated Materials (ORMs). A list of regulated waste codes accepted for storage at the HWSU is provided in this volume. Hazardous wastes are stored at the HWSU in containers that are compliant with U.S. Department of Transportation (DOT) regulations and compatible with the stored waste. Waste packages (e.g., drums) without inner closed containers of waste remain closed except during inspection or sampling. Transfer of uncontainerized waste between waste packages at the HWSU is prohibited. Closed inner containers may be transferred or consolidated into larger waste packages, and small closed containers may be placed into larger containers. Containers are stored on secondary containment pallets, and the unit is inspected monthly. For safety and security reasons, some of the contents of the full application are not available for public viewing. This public version of the application contains most, but not all, of the contents as submitted to the regulatory agencies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Productivity Is a Poor Predictor of Plant Species Richness.

For more than 30 years, the relationship between net primary productivity and species richness has generated intense debate in ecology about the processes regulating local diversity. The original view, which is still widely accepted, holds that the relationship is hump-shaped, with richness first rising and then declining with increasing productivity. Although recent meta-analyses questioned the generality of hump-shaped patterns, these syntheses have been criticized for failing to account for methodological differences among studies. We addressed such concerns by conducting standardized sampling in 48 herbaceous-dominated plant communities on five continents. We found no clear relationship between productivity and fine-scale (meters-2) richness within sites, within regions, or across the globe. Ecologists should focus on fresh, mechanistic approaches to understanding the multivariate links between productivity and richness.

60 APPLIED LIFE SCIENCES↗

Molecular Reaction Imaging of a Surface Recombination Process Explains Performance Variation Among Smooth MoS 2 Photoelectrodes

Transition metal dichalcogenides (TMD) such as WSe 2 and MoS 2 are highly efficient and stable light absorbers in TMD∣I − ,I 3 − ∣Pt liquid junction solar cells. It is generally accepted that TMD crystals with a large fraction of exposed edge sites exhibit lower power conversion efficiencies (PCEs) than apparently smooth crystals. However, one open question is why does the PCE vary significantly from one crystal to another? Answering this critical question could lead to robust syntheses for high quality and uniform TMD samples. In this work, we apply nanoscale photoelectrochemical microscopy techniques to study n-type TMD nanoflake∣I − ,I 3 − ∣Pt cells. Using a combination of near-diffraction-limited photocurrent mapping and molecular reaction imaging techniques, we reveal a previously hidden surface recombination process: photogenerated holes in hidden p-type domains travel micron-scale distances parallel to the solid/liquid interface and preferentially react with iodide at step-edges. The overall efficiency of the nanoflake, as evidenced from whole nanoflake-level photoelectrochemical measurements, is dictated by the size, efficiency, and location of n- and p-type domains. Furthermore, these results provide a unifying view of efficiency losses in smooth TMD photoelectrodes and open the possibility to design electrode architectures that leverage the long-range lateral charge transport property for photoelectrocatalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dijet production in s = 7 TeV p p collisions with large rapidity gaps at the ATLAS experiment

CERN-LHC. Measurements of the pseudorapidity gap and xi distributions for dijet production in diffractive events which are defined by large gaps devoid of activity seen in the ATLAS detector, based on a sample of proton-proton collisions at a centre-of-mass energy of 7 TeV of integrated luminosity of 6.8 nb-1 collected in 2010. The final state consists of two jets found by the anti-kt jet algorithm with transverse momentum greater than 20 GeV and empty regions in the acceptance of the ATLAS detector. The pseudorapidity gap variable, denoted here as DELTA(C=RAPGAP), is defined as the larger of the pseudorapidity regions extending to the limits of the ATLAS detector sensitivity at eta=+-4.8, in which no final state particles are observed above a (transverse) momentum threshold. The xi variable is calculated using M**2/S and for Single Diffraction DELTA(C=RAPGAP)~=-ln(xi). See PLBXX (2015) YY for more details.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of Harrell Monosodium Titanate Lot #s 46000606120, 46000722120, AND 46000808120

Monosodium titanate (MST) for use in the Actinide Removal Process (ARP) must be qualified and verified in advance. A single qualification sample for each batch of material is sent to SRNL for analysis, as well as a statistical sampling of verification samples. The Harrell Industries Lot #s 46000706120, 46000722120, and 460008081120 qualification and verification samples met each of the selected specification requirements that were tested with the exception of a few pails being marginally below the lower weight percent solids limit. These deviations from the specifications are viewed as negligible since the corresponding density of the slurries indicates no appreciable shortage of MST solids. Therefore, SRNL recommends acceptance and use of these pails.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury Emission Measurement at a CFB Plant

In response to pending regulation to control mercury emissions in the United States and Canada, several projects have been conducted to perform accurate mass balances at pulverized coal (pc)-fired utilities. Part of the mercury mass balance always includes total gaseous mercury as well as a determination of the speciation of the mercury emissions and a concentration bound to the particulate matter. This information then becomes useful in applying mercury control strategies, since the elemental mercury has traditionally been difficult to control by most technologies. In this instance, oxidation technologies have proven most beneficial for increased capture. Despite many years of mercury measurement and control projects at pc-fired units, far less work has been done on circulating fluidized-bed (CFB) units, which are able to combust a variety of feedstocks, including cofiring coal with biomass. Indeed, these units have proven to be more problematic because it is very difficult to obtain a reliable mercury mass balance. These units tend to have very different temperature profiles than pc-fired utility boilers. The flexibility of CFB units also tends to be an issue when a mercury balance is determined, since the mercury inputs to the system come from the bed material and a variety of fuels, which can have quite variable chemistry, especially for mercury. In addition, as an integral part of the CFB operation, the system employs a feedback loop to circulate the bed material through the combustor and the solids collection system (the primary cyclone), thereby subjecting particulate-bound metals to higher temperatures again. Despite these issues, CFB boilers generally emit very little mercury and show good native capture. The Energy & Environmental Research Center is carrying out this project for Metso Power in order to characterize the fate of mercury across the unit at Rosebud Plant, an industrial user of CFB technology from Metso. Appropriate solids were collected, and flue gas samples were obtained using the Ontario Hydro method, mercury continuous emission monitors, and sorbent trap methods. In addition, chlorine and fluorine were determined for solids and in the flue gas stream. Results of this project have indicated a very good mercury mass balance for Rosebud Plant, indicating 105 {+-} 19%, which is well within acceptable limits. The mercury flow through the system was shown to be primarily in with the coal and out with the flue gas, which falls outside of the norm for CFB boilers.

01 COAL, LIGNITE, AND PEAT↗

Evaluation of Final Radiological Conditions at Areas of the Niagara Falls Storage Site Remediated under the Formerly Utilized Sites Remedial Action Program - 12184

The U.S. Department of Energy (DOE) methods and protocols allow evaluation of remediation and final site conditions to determine if remediated sites remain protective. Two case studies are presented that involve the Niagara Falls Storage Site (NFSS) and associated vicinity properties (VPs), which are being remediated under the Formerly Utilized Sites Remedial Action Program (FUSRAP). These properties are a part of the former Lake Ontario Ordnance Works (LOOW). In response to stakeholders concerns about whether certain remediated NFSS VPs were putting them at risk, DOE met with stakeholders and agreed to evaluate protectiveness. Documentation in the DOE records collection adequately described assessed and final radiological conditions at the completed VPs. All FUSRAP wastes at the completed sites were cleaned up to meet DOE guidelines for unrestricted use. DOE compiled the results of the investigation in a report that was released for public comment. In conducting the review of site conditions, DOE found that stakeholders were also concerned about waste from the Separations Process Research Unit (SPRU) at the Knolls Atomic Power Laboratory (KAPL) that was handled at LOOW. DOE agreed to determine if SPRU waste remained at that needed to be remediated. DOE reviewed records of waste characterization, historical handling locations and methods, and assessment and remediation data. DOE concluded that the SPRU waste was remediated on the LOOW to levels that pose no unacceptable risk and allow unrestricted use and unlimited exposure. This work confirms the following points as tenets of an effective long-term surveillance and maintenance (LTS and M) program: - Stakeholder interaction must be open and transparent, and DOE must respond promptly to stakeholder concerns. - DOE, as the long-term custodian, must collect and preserve site records in order to demonstrate that remediated sites pose no unacceptable risk. - DOE must continue to maintain constructive relationships with the U.S. Army Corps of Engineers and state and federal regulators. After review of historical site documentation, DOE reports, and USACE radiological data, DOE concluded the following: - DOE had access to adequate documentation to evaluate site conditions at the former LOOW. This is important to confirm now, while institutional knowledge of early FUSRAP work remains available. - DOE remediated the completed VPs to conditions that are protective for unrestricted residential use. Sample and walkover gamma scan results indicate that no wastes remain that exceed cleanup criteria. - Process knowledge and field observations establish that Cs-137 is the predominant radionuclide in the KAPL waste stream. Cs-137, a strong gamma emitter, was used as an indicator for remediation of KAPL waste. Other radionuclides were present in much lower relative concentrations and were likely also removed during remediation of the VPs. - KAPL contaminants were removed during remedial activities at the former LOOW as either co-located or co-mingled with other radionuclides. - For the active VPs (VP-E, VP-E', and VP-G), results of DOE's cleanup of the accessible portions of these properties indicate that KAPL waste does not remain at concentrations greater than the DOE cleanup limit: - Inaccessible areas were not associated with historic KAPL waste handling. Therefore, it is unlikely that KAPL waste remains on the active VPs. - Because gamma activity was used by DOE during remediation/verification activities for excavation control, additional USACE cleanup of FUSRAP wastes on these properties will likely result in the remediation of any co-located residual KAPL wastes to acceptable levels or identification of KAPL waste that is not co-located. - Although USACE has not established a cleanup level for Cs-137 on the active NFSS VPs, DOE assessment and remediation data indicate that assessed Cs-137 was remediated and significant Cs-137 is unlikely to remain. Because of the low likelihood of encountering significant KAPL waste on the active NFSS VPs, additional remediation is not anticipated at these properties. - USACE assessment soil sampling results on the NFSS proper indicate that KAPL waste does not exceed the DOE cleanup level for Cs-137. USACE has not established a cleanup level for Cs-137 on NFSS proper. The USACE cleanup of FUSRAP wastes on the NFSS proper will likely result in the remediation of any co-located residual KAPL wastes or identification of KAPL waste that is not co-located. DOE is drafting a report of the investigation of KAPL waste at LOOW. The report will be released to the public for comment when the draft is complete. DOE responses to stakeholder inquiries resulted in a common understanding of site conditions and site risk. DOE expects additional interaction with stakeholders at the former LOOW as USACE completes remediation of the active VPs and the NFSS proper, and these relationships will hopefully have built trust between DOE and the stakeholders that DOE will perform its duties in an open and transparent manner that includes stakeholders as stewards for remediated FUSRAP sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CONSTRAINING THE MILKY WAY'S HOT GAS HALO WITH O VII AND O VIII EMISSION LINES

The Milky Way hosts a hot (≈2 × 10{sup 6} K), diffuse, gaseous halo based on detections of z = 0 O VII and O VIII absorption lines in quasar spectra and emission lines in blank-sky spectra. Here we improve constraints on the structure of the hot gas halo by fitting a radial model to a much larger sample of O VII and O VIII emission line measurements from XMM-Newton/EPIC-MOS spectra compared to previous studies (≈650 sightlines). We assume a modified β-model for the halo density distribution and a constant-density Local Bubble from which we calculate emission to compare with the observations. We find an acceptable fit to the O VIII emission line observations with χ{sub red}{sup 2} (dof) = 1.08 (644) for best-fit parameters of n{sub o}r{sub c}{sup 3β}=1.35±0.24 cm{sup –3} kpc{sup 3β} and β = 0.50 ± 0.03 for the hot gas halo and negligible Local Bubble contribution. The O VII observations yield an unacceptable χ{sub red}{sup 2} (dof) = 4.69 (645) for similar best-fit parameters, which is likely due to temperature or density variations in the Local Bubble. The O VIII fitting results imply hot gas masses of M(<50 kpc) = 3.8{sub −0.3}{sup +0.3}×10{sup 9} M{sub ⊙} and M(<250 kpc) = 4.3{sub −0.8}{sup +0.9}×10{sup 10} M{sub ⊙}, accounting for ≲50% of the Milky Way's missing baryons. We also explore our results in the context of optical depth effects in the halo gas, the halo gas cooling properties, temperature and entropy gradients in the halo gas, and the gas metallicity distribution. The combination of absorption and emission line analyses implies a sub-solar gas metallicity that decreases with radius, but that also must be ≥0.3 Z {sub ☉} to be consistent with the pulsar dispersion measure toward the Large Magellanic Cloud.

79 ASTRONOMY AND ASTROPHYSICS↗

SPRUCE Bud Cold Hardiness of Trees and Shrubs in Experimental Plots, Marcell Experimental Forest, Minnesota, 2021-2025

This dataset contains bud cold hardiness measurements from the Spruce and Peatland Responses Under Changing Environments (SPRUCE) experimental site (Hanson et al, 2017) within the Marcell Experimental Forest in northern Minnesota, USA. Cold hardiness was quantified as the temperature at which low temperature exotherms (LTEs) were identified (i.e., the temperature at which supercooled water within a bud freezes) measured by differential thermal analysis (DTA). Buds were sampled at semi-regular intervals from September 2021 through May 2025 (2021-09-25 to 2025-05-21) across four seasons (2021-2022 through 2024-2025) for four co-occurring boreal peatland tree and shrub species: Picea mariana (PIMA), Larix laricina (LALA), Rhododendron groenlandicum (RHGR), and Chamaedaphne calyculata (CHCA). Samples were collected across the experiment's warming gradient (ambient to +9 degrees Celsius (C)) and pooled by species within each enclosure. These data were used to assess the species- and season-specific effects of experimental warming on cold hardiness and cold damage risk in boreal peatland vegetation (Campos-Arguedas et al, accepted). This dataset contains one data file in comma-separate values (*.csv) format. Additional metadata are provided: a data dictionary and a file-level metadata file in comma-separate values (*.csv) format and a user guide in PDF (*.pdf) format.

Chamaedaphne calyculata↗

Standardized Testing Program for Solid-State Hydrogen Storage Technologies

In the US and abroad, major research and development initiatives toward establishing a hydrogen-based transportation infrastructure have been undertaken, encompassing key technological challenges in hydrogen production and delivery, fuel cells, and hydrogen storage. However, the principal obstacle to the implementation of a safe, low-pressure hydrogen fueling system for fuel-cell powered vehicles remains storage under conditions of near-ambient temperature and moderate pressure. The choices for viable hydrogen storage systems at the present time are limited to compressed gas storage tanks, cryogenic liquid hydrogen storage tanks, chemical hydrogen storage, and hydrogen absorbed or adsorbed in a solid-state material (a.k.a. solid-state storage). Solid-state hydrogen storage may offer overriding benefits in terms of storage capacity, kinetics and, most importantly, safety. The fervor among the research community to develop novel storage materials had, in many instances, the unfortunate consequence of making erroneous, if not wild, claims on the reported storage capacities achievable in such materials, to the extent that the potential viability of emerging materials was difficult to assess. This problem led to a widespread need to establish a capability to accurately and independently assess the storage behavior of a wide array of different classes of solid-state storage materials, employing qualified methods, thus allowing development efforts to focus on those materials that showed the most promise. However, standard guidelines, dedicated facilities, or certification programs specifically aimed at testing and assessing the performance, safety, and life cycle of these emergent materials had not been established. To address the stated need, the Testing Laboratory for Solid-State Hydrogen Storage Technologies was commissioned as a national-level focal point for evaluating new materials emerging from the designated Materials Centers of Excellence (MCoE) according to established and qualified standards. Working with industry, academia, and the U.S. government, SwRI set out to develop an accepted set of evaluation standards and analytical methodologies. Critical measurements of hydrogen sorption properties in the Laboratory have been based on three analytical capabilities: 1) a high-pressure Sievert-type volumetric analyzer, modified to improve low-temperature isothermal analyses of physisorption materials and permit in situ mass spectroscopic analysis of the sample’s gas space; 2) a static, high-pressure thermogravimetric analyzer employing an advanced magnetic suspension electro-balance, glove-box containment, and capillary interface for in situ mass spectroscopic analysis of the sample’s gas space; and 3) a Laser-induced Thermal Desorption Mass Spectrometer (LTDMS) system for high thermal-resolution desorption and mechanistic analyses. The Laboratory has played an important role in down-selecting materials and systems that have emerged from the MCoEs.

08 HYDROGEN↗

Extraction, scrub, and strip test results for the solvent transfer to salt waste processing facility

The Savannah River National Laboratory (SRNL) prepared approximately 240 gallons of Caustic-Side Solvent Extraction (CSSX) solvent for use at the Salt Waste Processing Facility (SWPF). An Extraction, Scrub, and Strip (ESS) test was performed on a sample of the prepared solvent using a salt solution prepared by Parsons to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams. This data will be used by Parsons to help qualify the solvent for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 15.5, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗