Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “aberration correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Estimate Low and High Order Wavefront Using P1640 Calibrator Measurements

P1640 high contrast imaging system on the Palomar 200 inch Telescope consists of an apodized-pupil Lyot coronagraph, the PALM-3000 adaptive optics (P3K-AO), and P1640 Calibrator (CAL). Science images are recorded by an integral field spectrograph covering J-H bands for detecting and characterizing stellar companions. With aberrations from atmosphere corrected by the P3K-AO, instrument performance is limited mainly by the quasi-static speckles due to noncommon path wavefront aberrations for the light to propagate to the P3K-AO wavefront sensor and to the coronagraph mask. The non-common path wavefront aberrations are sensed by CAL, which measures the post-coronagraph E-field using interferometry, and can be effectively corrected by offsetting the P3K-AO deformable mirror target position accordingly. Previously, we have demonstrated using CAL measurements to correct high order wavefront aberrations, which is directly connected to the static speckles in the image plane. Low order wavefront, on the other hand, usually of larger amplitudes, causes light to leak through the coronagraph making the whole image plane brighter. Knowledge error in low order wavefront aberrations can also affect the estimation of the high order wavefront. Even though, CAL is designed to sense efficiently high order wavefront aberrations, the low order wavefront front can be inferred with less sensitivity. Here, we describe our method for estimating both low and high order wavefront aberrations using CAL measurements by propagating the post-coronagraph E-field to a pupil before the coronagraph. We present the results from applying this method to both simulated and experiment data.

aberrations↗

A novel electron mirror pulse compressor

An electron mirror-based pulse compressor design has been developed for improving the temporal resolution of dynamic/ultrafast transmission electron microscopes and ultrafast electron diffraction cameras. The improvement will enable electron microscopes and diffraction cameras to better resolve the dynamics of reactions in the areas of solid state physics, chemistry, and biology. The design utilizes a combination of mirror optics and a magnetic beam separator, which exploits the symmetry inherent in reversing the electron trajectory in the mirror in order to compress the pulse. This system can also simultaneously correct the spherical and chromatic aberration of the objective lens for improved spatial resolution. For pulsed experiments with a practical bunch charge, the correction of the chromatic aberration coefficient counters the spread in the electron energies induced by the space charge of the pulse to make possible the probing of the sample with high spatial resolution. The pulse compressor can accommodate pulses with a range of electron densities and energy spreads. Additionally, it is designed to fit into both ultrafast electron diffraction cameras and dynamic/ultrafast transmission electron microscopes. Consequently, this instrument is suitable for enhancing the study of the structure, composition, and bonding states of new materials at ultrafast time scales.

47 OTHER INSTRUMENTATION↗

First application of C{sub c} corrected imaging for high-resolution and energy-filtered TEM.

Contrast-transfer calculations indicate that C{sub c} correction should be highly beneficial for high-resolution and energy-filtered transmission electron microscopy. A prototype of an electron optical system capable of correcting spherical and chromatic aberration has been used to verify these calculations. A strong improvement in resolution at an acceleration voltage of 80 kV has been measured. Our first C{sub c}-corrected energy-filtered experiments examining a (LaAlO{sub 3}){sub 0.3}(Sr{sub 2}AlTaO{sub 6}){sub 0.7}/LaCoO{sub 3} interface demonstrated a significant gain for the spatial resolution in elemental maps of La.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PROGRESS IN BEAM FOCUSING AND COMPRESSION FOR WARM-DENSE MATTER EXPERIMENTS

The Heavy-Ion Fusion Sciences Virtual National Laboratory is pursuing an approach to target heating experiments in the Warm Dense Matter regime, using spacecharge-dominated ion beams that are simultaneously longitudinally bunched and transversely focused. Longitudinal beam compression by large factors has beendemonstrated in the Neutralized Drift Compression Experiment (NDCX) with controlledramps and forced neutralization. Using an injected 30-mA K+ ion beam with initialkinetic energy 0.3 MeV, axial compression leading to ~;;50-fold current amplification andsimultaneous radial focusing to beam radii of a few mm have led to encouraging energy deposition approaching the intensities required for eV-range target heating experiments. We discuss the status of several improvements to our Neutralized Drift Compression Experiment and associated beam diagnostics that are under development to reach the necessary higher beam intensities, including: (1) greater axial compression via a longer velocity ramp using a new bunching module with approximately twice the available voltseconds; (2) improved centroid control via beam steering dipoles to mitigate aberrations in the bunching module; (3) time-dependent focusing elements to correct considerable chromatic aberrations; and (4) plasma injection improvements to establish a plasma density always greater than the beam density, expected to be>1013 cm-3.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improvements in Ross type astrometric objectives

It is shown that aspheric deformations of the first and fourth elements of the four element Ross objective can be introduced to permit one to obtain improved color corrections for astrometric purposes. The usual monochromatic aberrations are as well corrected as for the standard Ross lens. In addition, one can eliminate or reduce additional aberrations, such as secondary spectrum, chromatic spherical aberration, chromatic coma and chromatic distortion. The resulting objectives are suitable for use as intermediate and long focus astrometric objectives covering large angle fields.

Baker, J.↗

Spherical mirror grazing incidence x-ray optics

An optical system for x-rays combines at least two spherical or near spherical mirrors for each dimension in grazing incidence orientation to provide the functions of a lens in the x-ray region. To focus x-ray radiation in both the X and the Y dimensions, one of the mirrors focusses the X dimension, a second mirror focusses the Y direction, a third mirror corrects the X dimension by removing comatic aberration and a fourth mirror corrects the Y dimension. Spherical aberration may also be removed for an even better focus. The order of the mirrors is unimportant.

Cash, Jr., Webster C.↗

Effects of Optical Artifacts in a Laser-Based Spacecraft Navigation Sensor

Testing of the Advanced Video Guidance Sensor (AVGS) used for proximity operations navigation on the Orbital Express ASTRO spacecraft exposed several unanticipated imaging system artifacts and aberrations that required correction to meet critical navigation performance requirements. Mitigation actions are described for a number of system error sources, including lens aberration, optical train misalignment, laser speckle, target image defects, and detector nonlinearity/noise characteristics. Sensor test requirements and protocols are described, along with a summary of test results from sensor confidence tests and system performance testing.

LeCroy, Jerry E.↗

Effects of Optical Artifacts in a Laser-Based Spacecraft Navigation Sensor

Testing of the Advanced Video Guidance Sensor (AVGS) used for proximity operations navigation on the Orbital Express ASTRO spacecraft exposed several unanticipated imaging system artifacts and aberrations that required correction to meet critical navigation performance requirements. Mitigation actions are described for a number of system error sources, including lens aberration, optical train misalignment, laser speckle, target image defects, and detector nonlinearity/noise characteristics. Sensor test requirements and protocols are described, along with a summary of test results from sensor confidence tests and system performance testing.

LeCroy, Jerry E.↗

Effects of Optical Artifacts in a Laser-Based Spacecraft Navigation Sensor

Testing Of the Advanced Video Guidance Sensor (AVGS) used for proximity operations navigation on the Orbital Express ASTRO spacecraft exposed several unanticipated imaging system artifacts and aberrations that required correction, to meet critical navigation performance requirements. Mitigation actions are described for a number of system error sources, including lens aberration, optical train misalignment, laser speckle, target image defects, and detector nonlinearity/noise characteristics. Sensor test requirements and protocols are described, along with a summary ,of test results from sensor confidence tests and system performance testing.

LeCroy, Jerry E.↗

Optimizing coronagraph designs to minimize their contrast sensitivity to low-order optical aberrations

The presence of optical aberrations in the entrance pupil of a coronagraph causes the stellar light to scatter about the occulting spot, reducing the effective contrast achievable. Even if these aberrations are sufficiently corrected with a deformable mirror to enable planet detection, small drifts in the optical alignment of the telescope introduce additional low-order aberrations.

Shaklan, Stuart B.↗

On the Fringe Field of Wide Angle LC Optical Phased Array

For free space laser communication, light weighted large deployable optics is a critical component for the transmitter. However, such an optical element will introduce large aberrations due to the fact that the surface figure of the large optics is susceptable to deformation in the space environment. We propose to use a high-resolution liquid crystal spatial light modulator to correct for wavefront aberrations introduced by the primary optical element, and to achieve very fine beam steering and shaping at the same time. A 2-D optical phased array (OPA) antenna based on a Liquid Crystal on Silicon (LCOS) spatial light modulator is described. This device offers a combination of low cost, high resolution, high accuracy, high diffraction efficiency at video speed. To quantitatively understand the influence factor of the different design parameters, a computer simulation of the device is given by the 2-D director simulation and the Finite Difference Time domain (FDTD) simulation. For the 1-D OPA, we define the maximum steering angle to have a grating period of 8 pixel/reset scheme; as for larger steering angles than this criterion, the diffraction efficiency drops dramatically. In this case, the diffraction efficiency of 0.86 and the Strehl ratio of 0.9 are obtained in the simulation. The performance of the device in achieving high resolution wavefront correction and beam steering is also characterized experimentally.

Wang, Xighua↗

High-resolution cryo-EM reconstructions in the presence of substantial aberrations

Here, an analysis is performed of how uncorrected antisymmetric aberrations, such as coma and trefoil, affect cryo-EM single-particle reconstruction (SPR) results, and an analytical formula quantifying information loss owing to their presence is inferred that explains why Fourier-shell coefficient-based statistics may report significantly overestimated resolution if these aberrations are not fully corrected. The analysis is validated with reference-based aberration refinement for two cryo-EM SPR data sets acquired with a 200 kV microscope in the presence of coma exceeding 40 µm, and 2.3 and 2.7 Å reconstructions for 144 and 173 kDa particles, respectively, were obtained. The results provide a description of an efficient approach for assessing information loss in cryo-EM SPR data acquired in the presence of higher order aberrations, and address inconsistent guidelines regarding the level of aberrations that is acceptable in cryo-EM SPR experiments.

3D reconstruction and image processing↗

Autonomous Phase Retrieval Calibration

The Palomar Adaptive Optics System actively corrects for changing aberrations in light due to atmospheric turbulence. However, the underlying internal static error is unknown and uncorrected by this process. The dedicated wavefront sensor device necessarily lies along a different path than the science camera, and, therefore, doesn't measure the true errors along the path leading to the final detected imagery. This is a standard problem in adaptive optics (AO) called "non-common path error." The Autonomous Phase Retrieval Calibration (APRC) software suite performs automated sensing and correction iterations to calibrate the Palomar AO system to levels that were previously unreachable.

Estlin, Tara A.↗

HST image restoration: A comparison of pre- and post-servicing mission results

A variety of image restoration techniques (e.g., Wiener filter, Lucy-Richardson, MEM) have been applied quite successfully to the aberrated HST images. The HST servicing mission (scheduled for late 1993 or early 1994) will install a corrective optics system (COSTAR) for the Faint Object Camera and spectrographs and replace the Wide Field/Planetary Camera with a second generation instrument (WF/PC-II) having its own corrective elements. The image quality is expected to be improved substantially with these new instruments. What then is the role of image restoration for the HST in the long term? Through a series of numerical experiments using model point-spread functions for both aberrated and unaberrated optics, we find that substantial improvements in image resolution can be obtained for post-servicing mission data using the same or similar algorithms as being employed now to correct aberrated images. Included in our investigations are studies of the photometric integrity of the restoration algorithms and explicit models for HST pointing errors (spacecraft jitter).

Hanisch, R. J.↗

A comparison of carbon impurities in pre- and post-melt uranium Part 2: Scanning/Transmission electron microscopy analysis

We report the speciation and morphology of U carbide inclusions in pre- and post-melt U metal have been explored using high-resolution analytical electron microscopy (AEM). This report presents Part 2 of our study, in which aberration (C s ) corrected transmission and scanning transmission electron microscopy (S)TEM was used to elementally and crystallographically characterize C-containing impurities and defect features in U samples for comparison with results obtained by scanning electron microscopy (SEM) in Part 1, previously published by this journal. Elemental mapping and unit cell matching of inclusions by (S)TEM are consistent with phases observed by SEM, and new dislocations can be observed associating with some inclusion morphologies and not others.

36 MATERIALS SCIENCE↗

Heavy-ion transfer reactions at large internuclear distance

The transfer reaction for the {sup 116}Sn+{sup 60}Ni system has been studied using the PRISMA magnetic spectrometer at different bombarding energies from above to well below the Coulomb barrier. The experiment has been done in inverse kinematics and light target-like ions have been detected with PRISMA placed at very forward angles. Good mass, nuclear charge and kinetic energy resolutions have been achieved. Sufficient statistics has been accumulated to extract angular distributions for different bombarding energies have been extracted and the response function of the spectrometer has been studied to correct for the aberration due to the transport of the ions in PRISMA. The comparison between the present case and the previously measured {sup 96}Zr+{sup 40}Ca system, superfluid and near closed shells nuclei, respectively, should significantly improve our understanding of nucleon-nucleon correlation properties in multinucleon transfer processes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Meter-scale plasma waveguides for multi-GeV laser wakefield acceleration

Here, we present results from two new techniques for the generation of meter-scale, low density (~10 17 cm -3 on axis) plasma waveguides, the “two-Bessel” technique, and the “self-waveguiding” technique. Plasma waveguides of this density and length range are needed for demonstration of a ~10 GeV laser wakefield accelerator module, key for future staging for a ~TeV lepton collider. Both techniques require the use of high quality ultrashort pulse Bessel beams to efficiently and uniformly ionize hydrogen gas in meter-scale supersonic gas jets via optical field ionization. We review these two techniques, describe our meter-scale gas jets, and present a new method for correction of optical aberrations in Bessel beams. Finally, we briefly present results from recent experiments employing one of our techniques, demonstrating quasi-monoenergetic acceleration of ~5 GeV electron bunches in 20 cm long, low density plasma waveguides.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗