Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Effects of Selenium Doping in Zinc Telluride from First Principles

We report point defects and compensation in zinc telluride have been subjects of study for several decades due to the compound’s scientific/technological applications. Despite this, there remains some disagreement in the literature as to the fine details of its defect chemistry. Recently, it has also come under renewed interest due to the emerging Cd( 1–x )Zn x Te( 1–y )Se y material family, used in nuclear radiation detector applications. In this article, we use state-of-the-art computational tools to re-examine the native defect chemistry of ZnTe and explore how it changes upon addition of selenium using density functional theory with screened hybrid exchange–correlation functionals, thermochemical models of the equilibration environment, and statistical mechanics models of the point defect ensemble.

II-VI semiconductors↗

Role of ferroelectric polarization during growth of highly strained ferroelectric materials

In ferroelectric thin films and superlattices, the polarization is intricately linked to crystal structure. Here we show that it can also play an important role in the growth process, influencing growth rates, relaxation mechanisms, electrical properties and domain structures. This is studied by focusing on the properties of BaTiO 3 thin films grown on very thin layers of PbTiO 3 using x-ray diffraction, piezoforce microscopy, electrical characterization and rapid in-situ x-ray diffraction reciprocal space maps during the growth using synchrotron radiation. Using a simple model we show that the changes in growth are driven by the energy cost for the top material to sustain the polarization imposed upon it by the underlying layer, and these effects may be expected to occur in other multilayer systems where polarization is present during growth. This motivates the concept of polarization engineering as a complementary approach to strain engineering.

36 MATERIALS SCIENCE↗

Diagnosing hot-spot symmetry in surrogate ignition experiments via secondary DT-neutron spectroscopy at the NIF

The directional energy spectrum of neutrons generated from the in-flight fusion reaction of 1-MeV tritons contains information about the hot-spot symmetry. The National Ignition Facility (NIF) fields Symmetry Capsule (Symcap) implosions, which have historically measured the symmetry of the radiation, drive by measuring the hot-spot shape via x-ray self-emission. Symcaps are used to tune the hot-spot symmetry for ignition experiments at the NIF. This work shows the relationship between directional secondary DT-n spectra and x-ray imaging data for a large database of Symcap implosions. A correlation is observed between the relative widths of the DT-n spectra measured with nTOFs and the shape measured with x-ray imaging. A Monte Carlo model, which computes the directional secondary DT-n spectrum, is used to interpret the results. A comparison of the x-ray and secondary DT-n data with the Monte Carlo model indicates that 56% of the variance between the two datasets is explained by a P2 asymmetry. More advanced simulations using HYDRA suggest that the unaccounted variance is due to P1 and P4 asymmetries present in the hot spot. The comparison of secondary DT-n data and x-ray imaging data to the modeling shows the DT-n data contain important information that supplements current P2 measurements and contain new information about the P1 asymmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of the N ∥ Upshift in the DIII-D high field side lower hybrid current drive experiment

High field side lower hybrid current drive (LHCD) is one potential candidate for efficient non-inductive current drive in tokamak power plants, and the first test of this technology will occur on the DIII-D tokamak during the 2024 campaign. Previous LFS launch experiments operated in the multi-pass regime and relied on scrape-off layer interactions to close the spectral gap. In the DIII-D experiment, single-pass damping is achievable via an upshift in the parallel refractive index N ∥ caused by mode converting twice (slow → fast → slow). This mode conversion affects the ray trajectories and can lead to enhanced N ∥ upshift depending on where mode conversion occurs. Compared to multi-pass absorption experiments, the optimization of launched N ∥ and plasma parameters can be counter-intuitive: increased density may increase efficiency and smaller N ∥,launch tend to damp closer to the separatrix. A hard x-ray camera installed to measure the bremsstrahlung (50–250 keV) radiation from LHCD-generated fast electrons is capable of verifying the trends reporting in this paper through comparison to the ray-tracing/Fokker–Planck codes GENRAY/CQL3D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identifying Critical Mineral Binding Mechanisms and Distribution in Acid Mine Drainage Treatment Solids to Inform Targeted Recovery Methods

In this study, micro-X-ray Fluorescence and micro/bulk X-ray Adsorption Near Edge Spectroscopy were collected at Stanford Synchrotron Radiation Lightsource and the Advanced Photon Source to: (1) gain a detailed characterization of critical minerals in Fe/Mn (hydr)oxide host phases; and (2) investigate the Co/Ni coordination and redox speciation associated with Fe/Mn (hydr)oxides phases in AMD solids with diverse composition (e.g., Al-rich, Mn-rich, Al/Mn/Fe-rich). Preliminary results show co-location of Co/Ni within Mn-rich hotspots, while Fe-rich hotspots were associated with heavy REEs. In Al-rich solids, Mn speciation was mostly comprised of Mn+3/+4 oxides, while the Mn-rich solids contain predominately Mn+4. These results suggest the AMD matrix plays an important role in how Co/Ni are coordinated, which aids in evaluating the efficacy to utilize AMD solids as a resource, and informs other novel sorbent and recovery technologies.

Hoffman, Colleen↗

Effect of Ion Irradiation on Amorphous and Crystalline Ge–Se and Their Application as Phase Change Temperature Sensor

Research on phase change materials is predominantly focused on their application as memory devices or for temperature control which requires low phase change temperature. The Ge–Se binary chalcogenide glass system with its wide glass-forming region is a potential candidate for high-temperature and high-radiation phase change applications. In this study, the concept of employing Ge x Se 100– x glasses to monitor high temperature (450–528 °C) using the phase change effect, is reported. Materials selection, device structure, and performance of prototype sensors are analyzed. In addition, the effect of heavy ion irradiation by Xe ions with energies of 200, 600, and 1000 keV (fluence ≈10 14 cm –2 ) on the Ge x Se 100– x ( x = 30, 33, 40) thin films and phase change devices is studied. The irradiation effect on the amorphous and crystalline structure of the thin films is evaluated by Raman spectroscopy and X-ray diffraction (XRD). Although the changes in the structural units of amorphous films are negligible, in crystalline films orthorhombic-GeSe 2 crystals are found to be most affected by irradiation and a new phase, orthorhombic GeSe is found in the thin films after irradiation. The performance of a sensor with an active film of Ge 40 Se 60 is also shown as an example.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rapid and efficient ambient temperature X-ray crystal structure determination at Turkish Light Source

High-resolution biomacromolecular structure determination is essential to better understand protein function and dynamics. Serial crystallography is an emerging structural biology technique which has fundamental limitations due to either sample volume requirements or immediate access to the competitive X-ray beamtime. Obtaining a high volume of well-diffracting, sufficient-size crystals while mitigating radiation damage remains a critical bottleneck of serial crystallography. As an alternative, we introduce the plate-reader module adapted for using a 72-well Terasaki plate for biomacromolecule structure determination at a convenience of a home X-ray source. We also present the first ambient temperature lysozyme structure determined at the Turkish light source (Turkish DeLight). The complete dataset was collected in 18.5 min with resolution extending to 2.39 Å and 100% completeness. Combined with our previous cryogenic structure (PDB ID: 7Y6A), the ambient temperature structure provides invaluable information about the structural dynamics of the lysozyme. Turkish DeLight provides robust and rapid ambient temperature biomacromolecular structure determination with limited radiation damage.

59 BASIC BIOLOGICAL SCIENCES↗

Initial design concepts for solid boron injection in ITER

As part of ITER’s consideration to change its first wall material from beryllium to tungsten, the ITER Organization has proposed studying the feasibility of real-time solid boron injection (SBI) into the plasma to coat the walls and divertor to supplement glow discharge boronization (GDB). Boron deposits getter oxygen and reduce sputtering of tungsten from plasma facing components (PFCs). Particularly in areas with significant plasma wall interactions, boron coatings are expected to be short-lived under high performance plasma conditions. The proposed SBI system aims to maintain boron layers in these areas to avoid excessive radiation from tungsten in the plasma as a risk mitigation to ensure ITER will be able to reach and sustain Q = 10 conditions. The system will be used sparingly, as redeposition of boron can lead to significant tritium retention, which must be minimized in ITER to comply with nuclear safety concerns. SBI is proposed to limit and precisely control the amount of boron injected in real-time during plasma operation. Here, some of the design requirements and initial concepts for an SBI system in ITER are presented based on previous results carried out with SBI systems on a number of tokamaks and stellarators around the world. Previous results using SBI systems installed by PPPL have injected boron particles from 5 µm–2 mm diameter at calibrated rates of 2–200 mg/s in real-time during plasma operation on AUG, DIII-D, EAST, KSTAR, LHD, TFTR, WEST, and W7-X, leading to improved wall conditions with reduced plasma impurity concentrations and radiated power and improved plasma performance. The boron is ionized in the plasma edge and then deposited on plasma-wetted surfaces. On AUG, EAST and WEST reduced tungsten sputtering sources were observed following several discharges with SBI. Extrapolation of these SBI results are presented to estimate the amount of boron needed for wall conditioning in ITER. Real-time SBI control requirements and plasma operation scenarios for ITER are also described.

36 MATERIALS SCIENCE↗

Microsecond Carrier Lifetimes in Polycrystalline CdSeTe Heterostructures and in CdSeTe Thin Film Solar Cells

We report significant advances in understanding and reducing nonradiative Shockley-Read-Hall recombination in polycrystalline CdSe x Te 1-x , leading to microsecond charge carrier lifetimes. In undoped Al 2 O 3 -passivated heterostructures we find external radiative efficiency 0.2%, quasi-Fermi level splitting 950 mV, mobility 100 cm 2 /(Vs), and diffusion length 14 µm. In solar cells measured lifetimes can exceed 1 µs. We interpret this data to indicate MgZnO/CdSeTe interface recombination velocity <; 100 cm/s. Based on our results, it appears CdTe PV technology has potentially overcome longstanding “recombination lifetime” limitation and in the near future will transition to improving other aspects of device design.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Characterization of high-flux cadmium zinc telluride detectors coupled to MM-PAD readout ASICs for high-flux X-ray applications

High-flux cadmium zinc telluride (HF-CZT) is a promising material for next-generation X-ray imaging due to its high stopping power, wide bandgap, and improved resistance to radiation-induced polarization [1]. We bonded 2 mm thick HF-CZT sensors with Cornell's Mixed-Mode Pixel Array ASICs, which combine analog charge integration and in-pixel digital counting to achieve single X-ray sensitivity, large full well capacity, and frame rates up to 10 kHz [2,3]. Detector characterization showed stable electron collection above 150 V bias, while hole collection remained limited by trapping even at 700 V. Temporal studies revealed non-negligible afterglow, with an unexpected increase in afterglow at higher biases, which was reduced by infrared illumination, suggesting that injected carriers reduce trapping near contact interfaces. Polarization measurements confirmed improved stability compared to conventional CZT, though polarization effects persisted, particularly with hole collection, with up to 5% signal loss and spatial distortion at high doses.

36 MATERIALS SCIENCE↗

Unraveling the size fluctuation and shrinkage of nanovoids during in situ radiation of Cu by automatic pattern recognition and phase field simulation

Void formation is an important aspect of irradiation response of metals. In situ transmission electron microscopy observation for void evolution during irradiation is an effective technique for studying void evolution. However, the amount of data collected during in situ studies drastically overwhelm the current capability for manual data analyses. Here, we used a data-driven approach where a convolutional neural network combined with greedy matching to detect and track nanovoid evolutions and migrations. This approach was able to discover the surprising phenomena of void size fluctuation and shrinkage during irradiation of Cu with pre-existing nanovoids. Phase–field simulations revealed the fundamental mechanism behind this in situ observed phenomenon of void size fluctuation.

36 MATERIALS SCIENCE↗

Coherent energy loss effects in dihadron azimuthal angular correlations in Deep Inelastic Scattering at small x

We perform an exploratory study of the role of coherent, medium-induced energy loss in azimuthal angular correlations in dihadron production in Deep Inelastic Scattering (DIS) at small x where the target proton/nucleus is modeled as a Color Glass Condensate. In this approach coherent radiative energy loss is part of the higher order corrections to the leading order dihadron production cross section. We include the effects of both gluon saturation and coherent radiative energy loss and show that radiative cold-matter energy loss has a significant effect on the so-called coincidence probability for the back-to-back production of dihadrons in DIS. In conclusion, we also define a double ratio of coincidence probabilities for a nucleus and proton targets and show that it is very robust against higher order radiative corrections.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Power loss analysis for the optical cavity of an x-ray laser oscillator

We investigate properties of optical elements in the optical cavity of an x-ray laser oscillator with emphasis on the power loss of a monochromatic Gaussian radiation beam upon passing through them using analytical and numerical approaches. Here we assume the optical cavity comprises of refractive lenses and Bragg crystals exploiting symmetric Bragg scattering. For the lens, we include focusing and curvature effects while we include angular filtering due to finite Darwin width of the Bragg crystal. Our results indicate the feasibility of x-ray power out-coupling in the range of 0.5%–28% with intracavity reflectivity of 67%–95% at 10.321 keV for nominal (≥ 65% reflectivity) cases. We also show the possibility of achieving high out-coupling of 35%–80% while restricting the intracavity reflectivity in the 19%–62% by adopting lossy cavities with 10–20 μ⁢m thin crystals.

36 MATERIALS SCIENCE↗

Collagen Fibril Orientation in Tissue Specimens From Atherosclerotic Plaque Explored Using Small Angle X-Ray Scattering

Atherosclerotic plaques can gradually develop in certain arteries. Disruption of fibrous tissue in plaques can result in plaque rupture and thromboembolism, leading to heart attacks and strokes. Collagen fibrils are important tissue building blocks and tissue strength depends on how fibrils are oriented. Fibril orientation in plaque tissue may potentially influence vulnerability to disruption. While X-ray scattering has previously been used to characterize fibril orientations in soft tissues and bones, it has never been used for characterization of human atherosclerotic plaque tissue. This study served to explore fibril orientation in specimens from human plaques using small angle X-ray scattering (SAXS). Additionally, plaque tissue was extracted from human femoral and carotid arteries, and each tissue specimen contained a region of calcified material. Three-dimensional (3D) collagen fibril orientation was determined along scan lines that started away from and then extended toward a given calcification. Fibrils were found to be oriented mainly in the circumferential direction of the plaque tissue at the majority of locations away from calcifications. However, in a number of cases, the dominant fibril direction differed near a calcification, changing from circumferential to longitudinal or thickness (radial) directions. Further study is needed to elucidate how these fibril orientations may influence plaque tissue stress–strain behavior and vulnerability to rupture.

60 APPLIED LIFE SCIENCES↗

PyPhase – a Python package for X-ray phase imaging

X-ray propagation-based imaging techniques are well established at synchrotron radiation and laboratory sources. However, most reconstruction algorithms for such image modalities, also known as phase-retrieval algorithms, have been developed specifically for one instrument by and for experts, making the development and diffusion of such techniques difficult. Here, PyPhase, a free and open-source package for propagation-based near-field phase reconstructions, which is distributed under the CeCILL license, is presented. PyPhase implements some of the most popular phase-retrieval algorithms in a highly modular framework supporting its deployment on large-scale computing facilities. This makes the integration, the development of new phase-retrieval algorithms, and the deployment on different computing infrastructures straightforward. Its capabilities and simplicity are presented by application to data acquired at the synchrotron source MAX IV (Lund, Sweden).

36 MATERIALS SCIENCE↗

A refraction correction for buried interfaces applied to in situ grazing-incidence X-ray diffraction studies on Pd electrodes

In situ characterization of electrochemical systems can provide deep insights into the structure of electrodes under applied potential. Grazing-incidence X-ray diffraction (GIXRD) is a particularly valuable tool owing to its ability to characterize the near-surface structure of electrodes through a layer of electrolyte, which is of paramount importance in surface-mediated processes such as catalysis and adsorption. Corrections for the refraction that occurs as an X-ray passes through an interface have been derived for a vacuum–material interface. In this work, a more general form of the refraction correction was developed which can be applied to buried interfaces, including liquid–solid interfaces. Furthermore, the correction is largest at incidence angles near the critical angle for the interface and decreases at angles larger and smaller than the critical angle. Effective optical constants are also introduced which can be used to calculate the critical angle for total external reflection at the interface. This correction is applied to GIXRD measurements of an aqueous electrolyte–Pd interface, demonstrating that the correction allows for the comparison of GIXRD measurements at multiple incidence angles. This work improves quantitative analysis of d-spacing values from GIXRD measurements of liquid–solid systems, facilitating the connection between electrochemical behavior and structure under in situ conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Inverse Method for Noninvasive Material Discrimination with Multienergy X-Ray Radiography

Active x-ray inspections have great potential for noninvasive detection of illicit materials. Dual-energy x-ray radiography, in particular, has been used to determine material composition by utilizing the energy-dependence of the x-ray attenuation coefficients. However, current implementations of this method are limited in their ability to determine the material composition of composite objects. Here, in this paper, we present an inverse algorithm that uses multienergy x-ray radiography data to noninvasively reconstruct the contents of a container. A critical feature of the current contribution is that material identification can be performed using conventional detectors and x-ray spectra with different endpoint energies produced by varying nothing more than the tube voltage. Adaptive regularization is used to increase the accuracy of material estimations from multienergy data sets. The utility of these methods is demonstrated with experimentally acquired radiographs obtained using a tunable x-ray source that produces spectra with endpoint energies of 100–450 keV. The object inspected is a scale model of a nuclear materials storage container composed of three-dimensional printed plastic and stainless-steel spheres inside a thin-walled steel container. Reconstructions of the steel sphere thicknesses are within a root-mean-square error of 0.37 cm.

47 OTHER INSTRUMENTATION↗