Energy Efficient Clothes Dryer with IR Heating and Electrostatic Precipitator

The project goal was to develop a revolutionary energy saving technology for residential clothes drying. The team developed an IR (infrared) heating system and NESP (Nebulizer and Electro-Static Precipitator) for integration into a ventless clothes dryer. The proposed technology addresses two of the major inefficiencies in current electric vented dryers by providing effective energy transfer for the removal of the water and recapture of the vapor latent heat. The IR heaters operating in the mid wave (2.5-10um) are very efficient as they target the 3-micron peak absorption of the water molecule. This allows direct energy absorption, unlike conventional element heaters where heat is transferred by convection. The low power NESP removes water vapor from the exhausted stream and recaptures the latent heat in the ESP (Electro-Static Precipitator) exchanger section. This allows the warm dry air to be recirculated back into the drum for additional efficiency savings. The remaining majority of the dryer hardware stays the same. Summing the efficiency gain from the two subcomponents we anticipated the EF (Efficiency Factor) to exceed the goal of 4.04. EF is obtained by dividing the weight (lbs) of water removed by the energy (kWhr) used, where the test load size is 8.45 lbs of bone dry clothing wetted to 57.5% or 4.8lbs of water, and dried to a remaining moisture content of 2.5-5%. Additional benefits include not having to recondition (heat or cool) the large amounts of make-up air to replace the air exhausted by a vented dryer. It was anticipated that the NESP/heat exchanger would be the most challenging and highest risk element in the program. Therefore, the team focused their efforts during Phase 1 of the program on the design, construction, testing, and optimization of the NESP/heat exchanger. At the end Phase 1, the team compared the performance of the NESP/heat exchanger with the system level requirements and made a Go/No-Go decision on proceeding with the second portion of the program. Phase 2 of the program was structured to develop the IR heating system and then integrate it and the NESP/heat exchanger into a residential clothes dryer prototype for final testing. The proposed technology utilizes heat recovery which is known to have the biggest impact on dryer efficiency. The two current mainstream recovery approaches are air to air exchangers and heat pump condenser systems. Air to air exchanges can be very efficient but require large surface areas which are prone to fouling from uncaptured lint. Dryers based on heat pump condenser recovery systems have shown efficiency improvements of 20–60% and are commercially available. The issue with a heat pump condenser approach is the added cost, as typical prices are twice that of standard vented dryers and they are only available in small to medium capacities. The energy factor (EF) for these systems is 5.50 to 6.88 pounds/kWh compared to conventional dryers at 2.75 to 3.67 pounds/kWh. The efficiency improvements for the proposed technology come from the use of IR heating and the NESP. As the concept is in its infancy, and these improvements were difficult to predict without experimental data, assumptions were made based on available literature. IR radiant drying times, when compared to convection, are typically 30% less. This is a result of the fact that radiant energy heats directly and is absorbed at and below the surface, unlike convection heating, that must conduct the heat through the boundary film of air at the clothes surface and rely on wicking of the moisture to the surface. The second area of improvement comes from the NESP. The NESP operation is as follows: 1. Highly charged, micron sized, droplets of water are injected into the dryer exhaust by the Nebulizer. 2. These charged droplets attract water molecules and continue to grow in size, until losing their charge. During this process, latent heat is rejected back into the air stream. 3. The large droplets enter the ESP, where they are recharged and drawn to the ESP wall, to be extracted at the bottom of the ESP. The warm dry air is then recirculated back into the dryer. The proposed technology, at the time of the proposal submission was estimated to have an EF of 4.79. At program completion we have designed, built, tested, integrated and optimized the proposed technologies into a prototype “high efficiency” residential clothes dryer. Testing of the integrated prototype dryer provided insight into the technical effectiveness and economic feasibility of the proposed technologies. The program has the potential of greatly impacting energy savings. The predicted EF of the proposed technology is 4.79, yielding an energy savings of 42% when compared to conventional electric vented dryers. Given there are approximately 84 million dryers in the US consuming ~64 billion kWh per year, a net savings of 27 billion kWh per year or 0.092 quads could be realized. Since the dryer is not vented, make up air from the room is not needed, adding an additional savings of ~1kWh per load, or 23.8 billion kWh per year. In addition, it is envisioned that the proposed ESP, when successful, would potentially find applications in industrial and residential dehumidification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Check-Testing of Manufacturer Self Reported Labeling Data& Compliance with MEPS

China first adopted minimum energy performance standards (MEPS) in 1989. Today, there are standards for a wide range of domestic, commercial and selected industrial equipment. In 1999, China launched a voluntary endorsement label, which has grown to cover over 40 products including water-saving products. Further, in 2005, China started a mandatory energy information label that initially covered two products and in 2007 was extended to cover four products total including: air conditioners; household refrigerators; clothes washers; and unitary air conditioners. These programs have had an important impact in reducing the energy consumption of appliances in China. China has built up a strong infrastructure to develop and implement standards. Historically, however, the government's primary focus has been on the technical requirements for specifying efficiency performance. Less attention has been paid to monitoring and enforcement with a minimal commitment of resources and little expansion of administrative capacity in this area. Thus, market compliance with both mandatory standard and labeling programs has been questionable. Furthermore, actual energy savings have quite possibly been undermined as a result. The establishment of a regularized monitoring system for tracking compliance with the mandatory standard and energy information label programs in China is a major area for program improvement. Over the years, the Collaborative Labeling and Appliance Standards Program (CLASP) has partnered with several Chinese institutions to promote energy-efficient products in China. CLASP, together with its implementing partner Lawrence Berkeley National Laboratory (LBNL), has assisted China in developing and updating the above-mentioned standards and labeling programs. Because of the increasing need for the development of a monitoring system to track compliance with the standard, CLASP, with support from Japan's Ministry of Economy, Trade and Industry (METI) and the Institute of Energy Economics, Japan (IEEJ), has expanded its on-going collaboration with the China National Institute of Standards (CNIS) to include enforcement and monitoring. CNIS has already begun working on the issue of compliance. In early 2007, LBNL compiled a report, with the support of METI, summarizing the findings from these activities and indicating China's progress to date. The report concluded that although the existing legal basis for monitoring and enforcement is sufficient- with multiple laws and regulations defining the responsibility of each government agency and specifying a system of fines and penal-ties for non-compliance-compared with international best practices, there is still a big gap in China's monitoring and enforcement efforts for mandatory standards and labels. In sum, the report concludes that while the sample size is far smaller than the mid-term goal of developing a regular check testing program for 20 percent of the market for each of the three products, this study provides highly valuable feedback on manufacturer compliance rates in the absence of a large-scale national testing program. With METI/IEEJ support, CLASP could assist the China Energy Label Center (CELC) in expanding its verification testing programs to cover more models and products, and in developing a plan for ramping up the national verification testing program over the next three to five years. This is particularly important as the information labeling program gains more visibility and expands to additional product categories. CLASP could also assist CELC to plan for a round-robin testing scheme-first among three national laboratories with sub-sequent expansion of this program to other regional test laboratories--with the goal of improving the consistency of testing results from different testing laboratories.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detecting flash drought events to inform adaptive water management

Abstract: Flash droughts are characterized by a rapid onset of drought conditions, a common feature among various indicators of these events. The lack of a standardized definition and indicator makes flash droughts particularly challenging to predict and manage. We test six state-of-the-art flash drought indicators using 41 years of daily data across all Hydrological Unit Code 4 (HUC4) regions in the contiguous United States. Our results show substantial disagreements among indicators, suggesting that the detection of a flash drought event strongly depends on the choice of indicator. From the perspective of informing management and operations, an open challenge remains: which flash drought indicator should be used to trigger operational adaptations? To this end, we propose a methodological framework that informs adaptive actions by regionally assessing the level of agreement between different indicators. The regional differences in hydroclimatic conditions are expected to be reflected in the level of agreement between indicators. To better inform adaptive actions, the framework will also consider the impacted sectoral water uses and their varying response times. The insights gained from this study improve the understanding of how these different flash drought indicators capture the different aspects of regional differences and impacted sectors. Furthermore, this information can support more targeted adaptive actions to mitigate adverse impacts through improved preparedness and response strategies.

climate resilience↗

Pulsed-Power Innovations for Next-Generation, High-Current Drivers

There are proposals to build larger high-current drivers to be used for high-energy-density physics (HEDP), inertial confinement fusion (ICF), radiation effects testing, and basic science. Drivers significantly larger than the Z Machine at Sandia National Laboratories, Albuquerque, NM, USA, encounter increasing difficulties in water power flow, insulator performance, and vacuum power flow. The physics requirements of imploding loads limit a designer’s flexibility in choosing machine parameters, such as current rise time, driving impedance, and total inductance. This article enumerates these physics constraints and shows how they impact driver design. Here, we conclude that advances in pulsed-power capabilities are needed to control risk and to build a cost-effective driver at peak currents of ~60 MA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Limited-In-Scope Comparison of Subsidence Scenarios For 3D Vadose Zone PORFLOW Trench Models

This technical memorandum summarizes the results from two separate sequences of 3D PORFLOW vadose zone flow and contaminant transport models that were used to test the impact of different spatial distributions of subsidence boundary conditions. More specifically, the two simulation setups used a general conceptual model for an engineered trench (ET): one with a subsided region specified in the center of the trench and one with a subsided region located at the end of the trench. Both subsided regions had the same geometric specifications (e.g., length, width, orientation), but used water infiltration rate boundary conditions that appropriately accounted for surface runoff and lateral drainage from the adjacent upslope intact regions of the final closure cap. Because of the substantially higher water infiltration rate associated with the subsided region at the end of the trench, this geometry produced higher absolute peak fluxes to the water table for all six radionuclides that were simulated. However, the slower release rate of the centrally located subsided hole geometry produced a higher flux to the water table in the time period subsequent to the absolute peak. A third model was implemented as a control, where the water infiltration rate that corresponds to the centrally located subsided region was applied at the end of the trench to highlight the purely geometric effects. The results show that a higher water infiltration rate produces a sharper peak, while a lower infiltration rate leads to a broader peak. A centrally located hole impacts more of the waste zone, producing a higher peak when an equal infiltration rate is applied. These generalized qualitative differences, and their impacts on the overall modeling workflow (i.e., from vadose zone models to limits and dose calculations), should receive appropriate consideration during the development of conceptual models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of radiolytic hydrogen generation and impact of drying treatments on reactor exposed and surrogate aluminum materials

Technical challenges associated with dry storage of Aluminum-clad Spent Nuclear Fuel (ASNF) include a need to better understand the potential extent of gaseous molecular hydrogen (H 2 ) production through radiolytic degradation of the aluminum (oxy)hydroxide films present on ASNF. The characterization of radiolytic gas generation from ASNF (oxy)hydroxide layers has been identified as a key knowledge gap which poses a technical challenge to the long-term storage of ASNF. Task 2 of the action plan for the extended (>50 years) dry storage of ASNF addresses this gap. Previous radiolysis studies performed under Task 2 established baseline estimates of H 2 generation rates from the attendant hydrated oxides. The results confirmed that net radiolytic H 2 production has a dependency on absorbed gamma dose, as well as relative humidity and cover gas composition (air, nitrogen, and argon). Further experiments revealed that the physisorbed water on the samples may significantly impact the radiolytic H 2 yield. This phenomenon complicates the determination of H 2 generation rates for hydrated oxides, which may lead to inaccurate modeling predictions of the long-term H 2 yields in sealed storage systems containing ASNF, particularly when compared to spent fuel casks which have undergone some drying process intended to remove physically- and chemically-bound water. This report describes the testing methods utilized and the hydrogen generation results obtained in an investigation of the effects of gamma irradiation on aluminum materials for a variety of (oxy)hydroxide surface compositions and drying conditions. The testing methods included small-area aluminum material testing in ampules, and large-area aluminum material testing in steel vessels. Test material preparation, irradiation, and radiolytic H 2 measurement methods are summarized. The measured H 2 concentrations, which reflect the variable initial hydrated inventory and drying treatments, are compared to one another as well as to previously published data, to identify the primary factors affecting radiolytic H 2 generation rates and potential equilibrium H 2 concentrations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Geant4 Simulations and Experimental Results for the Pacific-Ocean Neutrino Experiment (P-ONE)

The Pacific-Ocean Neutrino Experiment (P-ONE) is an upcoming large-volume neutrino telescope planned to be built off the coast of Vancouver Island, Canada. It aims to detect high-energy neutrinos via the Cherenkov radiation produced in water by secondary particles born from high-energy neutrino interactions. Its first set of detectors is planned to be commissioned this year. However, since the telescope is still in its early stages of development, many tests and simulations must still be run to characterize the efficacy of the detectors. One necessary simulation must be devoted towards examining whether the polarization of the incoming Cherenkov light impacts the strength of the signals by the PMTs, and it must be supported by experimental data. In this report, I detail what I have completed during my SULI internship at the Los Alamos National Lab (LANL); I present the preliminary results of a Geant4 polarization simulation as well as preliminary laboratory measurements that will later be used to inform the future P-ONE design.

74 ATOMIC AND MOLECULAR PHYSICS↗

SERFE Water Quality Results

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is underdevelopment to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. Water quality, and how that impacts the performance of the life support system hardware, are areas where improvements could greatly help to achieve these goals. The Suit Water Membrane Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal loop technologies was developed and has been under test in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack since November of 2020. In addition to the SWME, The SWME EXPRESS Rack Flight Experiment (SERFE) contains several technology demonstrations from the xEMU project and has been demonstrating their performance in micro-gravity and over an extended duration. This paper will summarize the results of the water quality analysis performed to date throughout the SERFE testing program. Special care was taken to select materials, process hardware, and control the quality of the feedwater used in SERFE testing so that it would be representative of a thermal control system that could be used on a spacesuit for a lunar mission. In addition, the testing schedule, including periods of quiescence in between tests, was also selected to simulate a real mission profile in ways that would be critical to water quality. Results include data and analysis on microbial activity, biocidal iodine, metals, organic carbon, and several other customary indicators of water quality in an operational system. Testing spans over a year and a half of wetted life of the SERFE Flight Unit and the SERFE Ground Unit.

Colin Campbell↗

Effect of Curing Environment on the Performance Properties of Saltstone - 13335

At the Savannah River Site (SRS), the low level radioactive waste (LLW) salt solution is immobilized as a cementitious waste form known as Saltstone. Depending on the Saltstone formulation, disposal unit size, environmental conditions and pour schedule, the waste form temperature, due to exothermic hydration reactions, can gradually increase by 30 deg. C to 50 deg. C above the starting temperature. Previous studies at Savannah River National Laboratory (SRNL) have shown that curing temperature has a negative impact on the hydraulic conductivity and other performance properties of Saltstone; specifically, these studies have shown that curing at elevated temperatures results in faster hydraulic conductivities than what is modeled in the Saltstone Performance Assessment (PA). SRNL is currently testing the performance of laboratory prepared Saltstone cured under controlled conditions (i.e. controlling relative humidity). The PA assumes that the Saltstone remains saturated; therefore, some samples are being kept completely saturated while others have a surface exposed to a high humidity environment. The formulation of these samples has been varied to continue studying the impact of processing parameters on the performance properties of Saltstone. The final water to premix (w/p) ratio of the Saltstone formulation does affect the density, porosity, and compressive strength of the cured Saltstone. The Saltstone formulations with 0.59 w/p ratios and lower had higher densities, lower porosities, and higher compressive strength than samples formulated at a higher w/p ratio. There is a general trend that the samples formulated at high w/p ratios (0.67 and higher) have the lowest density, highest porosity and lowest strength. However, for hydraulic conductivity, the curing environment had a greater effect on the results than the formulation. Therefore, the impact of elevated temperature is not as detrimental to the performance of the waste form as originally concluded, provided the curing environment is controlled and the waste form is not dried out. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Potential Advantages to Employing an Onsite Laboratory at FUSRAP Sites Contaminated with Radionuclides and Metals - 20353

Various factors that support an evaluation of the relative costs, advantages and disadvantages of utilizing an onsite laboratory or an offsite laboratory for remediation of Formerly Utilized Sites Remedial Action Program (FUSRAP) sites contaminated with radionuclides and metals are presented. In terms of how much more quickly an onsite laboratory provides results versus an offsite laboratory, the results of this study provide tools for calculating the amount of cost savings per day for excavation of contaminated soils for various scenarios including: - State, municipal or local property remediation where the remediation schedule becomes time-critical due to the extra cost and inconvenience to the town or municipality caused by the need for increased security and safety personnel, possible road closures and detours, and the inconvenience to the public due to modified or decreased services of State or municipal facilities; - Residential property where the remediation schedule becomes time-critical due to the inconvenience to the homeowner as well as the importance of maintaining good community relations; - Commercial property where the remediation schedule becomes time-critical due to the hardship and potential loss of revenue endured by the property owner; - Open area where treatment of excavation water is required, and - Open area where treatment of excavation water is not required. For every scenario, the number of matrices, radionuclide and metal contaminants of concern and the project duration are important factors. The costs for the onsite laboratory included the capital costs associated with setting up the lab such as trailer(s) or building(s), power and water hookup, analytical testing equipment, balances, computers, desks and bookcases; support equipment such as hot plates, filtration assemblies, safety equipment, ovens, etc.; and supplies such as glassware, pipettes, filters, etc. and ongoing costs such as labor, chemicals and reagents, standards, cost of the laboratory obtaining certification and maintenance. Offsite laboratory sample testing costs are generally very competitive and typically substantially lower than onsite laboratory costs if only the sample testing costs are considered. The great disadvantage of using an offsite laboratory is that they often cannot guarantee rapid turnaround times for results which creates project delays associated with the remediation process including delays determining the completeness of the characterization and remediation processes, delays in backfilling a property and additional costs for treating wastewater (excavation water, stormwater or both). These costs will vary greatly depending upon the area of the country in which the project is located due to the wide range of labor costs for the onsite laboratory and field workers, as well as the contaminants of interest, matrices and most importantly the size of the impacted area and the number of properties located in that area. This paper provides guidelines for calculating the cost savings that may be realized if an onsite laboratory can generate results more quickly than an offsite laboratory by estimating the costs associated with the remediation process for the various scenarios noted above such as work crew labor costs, excavator and dump truck equipment rentals, wastewater treatment costs (if applicable) and the additional costs incurred by homeowners, commercial property owners and towns/municipalities that are reimbursed by the potentially responsible parties. Key assumptions involve the typical quickest turnaround time provided by the onsite and offsite laboratories. Costs for the operation of a wastewater treatment system and the remediation of a site area or property were provided by personnel who have been involved in the operation of a large FUSRAP site in New Jersey for many years. This study provides valuable information for determining the most cost-effective approach for analysis of project samples and therefore may be used on upcoming FUSRAP projects. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Milestone 1.2.11: H 2 Production from Surrogate Non-Native Corrosion Plumes on Aluminum 6061-T6 Fuel Cladding Surrogates

Thick, localized, “non-native” corrosion plumes have been identified on Advanced Test Reactor fuel elements, raising concern on their impact on the radiolytic formation of molecular hydrogen gas (H 2 ) from aluminum-clad spent nuclear fuel (ASNF) under proposed extended (> 50 years) dry storage conditions. Here, we report our findings on H 2 generation from the gamma irradiation (up to 52 MGy) of surrogate “non-native” corrosion plume coupons: ambient-temperature-corroded (~350 days in water) aluminum alloy 6061 (AA6061) coupons in helium gas environments with ~0% added relative humidity. Additionally, we provide a comparison of proposed ASNF drying techniques— vacuum drying only, vacuum drying + 100 °C for 4 hr, and vacuum drying + 220 °C for 4 hr—on the yield of H 2 from these surrogate systems. The presented data indicates that similar amounts of H 2 (~2 × 10–3 µmol J–1) are formed from gamma irradiated AA6061 coupons corroded under different temperature regimes, i.e., ambient/350 days vs. 90 C/30 days. These findings validate current, complimentary modelling predictions based on high-temperature-corrosion irradiation data only. Further, the application of a heat treatment procedure (100 and 220 °C), in conjunction with vacuum drying, accelerated the rate at which a steady-state H 2 yield was attained, in comparison to vacuum only, due to the removal of H 2 precursors in the form of adsorbed waters. Interestingly, within the confidence limits of our measurements, negligible difference in total H 2 yield was found between the two investigated heat treatment procedures.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Cost Competitive Process of Battery Grade Oxides Preparation from Aged LIBS

The increasing demand for lithium-ion batteries (LIBs ) is driving development of advanced recycling and refining methods. In this project, new cathode active materials are prepared from recycled lithium battery materials and subsequently electrochemically evaluated in coin cells. In detail, scrap LIBs were mechanically processed into a metal rich black mass, then reductive acid leached into an aqueous metal solution, and finally high-purity metal hydroxide precursor materials were prepared by selective electrochemical flow precipitation. Closed-loop LIB recycling into active electrode materials will enable US manufacturers to break their reliance on foreign sources of critical materials. For example, electroextraction process used here has potential to significantly reduce chemical & water use as compared to traditional metallurgic techniques. To this end, electroextracted materials refined from used batteries were collected and processed to be tested as precursor cathode active material (pCam).During this project ,samples of high-purity recycled NMC hydroxide (~2kg each) were received from Nth Cycle. In the first received batch some impurities like cadmium, calcium, and sodium are present in quantities that would negatively impact battery performance. Nth Cycle indicated that the impurities such as cadmium are present due to poor battery separation and co-shredding of NiCd batteries with with LIB. Cadmium was not present in the two subsequent batches as Nth Cycle processed cadmium free black mass. Thus, effective recycled battery sorting is critical to closed-loop LIB recycling into active electrode materials.

99 GENERAL AND MISCELLANEOUS↗

Experimental Study of Supercooled Large Droplet Impingement Effects

Typically, ice accretion results from small supercooled droplets (droplets cooled below freezing), usually 5 to 50 microns in diameter, which can freeze upon impact with an aircraft surface. Recently, ice accretions resulting from supercooled large droplet (SLD) conditions have become a safety concern. Current ice accretion codes have been extensively tested for Title 14 Code of Federal Regulations Part 25, Appendix C icing conditions but have not been validated for SLD icing conditions. This report presents experimental methods for investigating large droplet impingement dynamics and for obtaining small and large water droplet impingement data.

ICE ACCRETION CODE↗

Drying of Spent Nuclear Fuel: Considerations and Examples

A recently revised American Society for Testing and Materials consensus standard guide for drying of spent nuclear fuel (SNF) provides considerations and guidance for preparing SNF for its safe storage in a sealed dry storage system. The standard discusses (1) needs for drying, (2) techniques to dry, and (3) demonstration of adequate dryness. No specific approach is prescribed since the effective techniques and needs for drying depend on the specifics of the fuel and dry storage system. Here, this paper discusses these topics using examples for both Zr-alloy-clad commercial SNF and for aluminum-alloy-clad research reactor SNF. Residual water can include free water (liquid and/or vapor), physisorbed water bound to internal surfaces, and chemisorbed water incorporated into surface films, such as (oxy)hydroxides. The potential impacts of these residual waters are corrosion/oxidation, radiolytic breakdown into gaseous and/or reactive species, and canister pressurization. For commercial SNF, inadvertent free water, even up to large amounts (e.g., 10+ mol), is not predicted to cause adverse corrosion degradation, except possible fuel oxidation for breached SNF. For aluminum-clad SNF, the production of radiolytic hydrogen with contribution from the chemisorbed water in its hydrated oxides is a primary consideration. For both SNF systems, canister pressurization is predicted to be well within the canister design, and flammability would not pose a safety concern using an oxygen limit of 5 vol % criterion. (Flammability control can be achieved by limiting either hydrogen or oxygen, and an oxygen limit is expected to be easier to meet in the presence of radiolytic H 2 generation.) The two primary technologies for SNF drying, vacuum drying and forced-gas dehydration, are described herein, and drying tests and campaigns using these methods are cited. Dryness criteria and the methods used to detect and measure residual (free) water are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

WASTE SOLIDIFICATION BUILDING BENCH SCALE HIGH ACTIVITY WASTE SIMULANT VARIABILITY STUDY FY2008

The primary objective of this task was to perform a variability study of the high activity waste (HAW) acidic feed to determine the impact of feed variability on the quality of the final grout and on the mixability of the salt solution into the dry powders. The HAW acidic feeds were processed through the neutralization/pH process, targeting a final pH of 12. These fluids were then blended with the dry materials to make the final waste forms. A secondary objective was to determine if elemental substitution for cost prohibitive or toxic elements in the simulant affects the mixing response, thus providing a more economical simulant for use in full scale tests. Though not an objective, the HAW simulant used in the full scale tests was also tested and compared to the results from this task. A statistically designed test matrix was developed based on the maximum molarity inputs used to make the acidic solutions. The maximum molarity inputs were: 7.39 HNO{sub 3}, 0.11618 gallium, 0.5423 silver, and 1.1032 'other' metals based on their NO{sub 3}{sup -} contribution. Substitution of the elements aluminum for gallium and copper for silver was also considered in this test matrix, resulting in a total of 40 tests. During the NaOH addition, the neutralization/pH adjustment process was controlled to a maximum temperature of 60 C. The neutralized/pH adjusted simulants were blended with Portland cement and zircon flour at a water to cement mass ratio of 0.30. The mass ratio of zircon flour to Portland cement was 1/12. The grout was made using a Hobart N-50 mixer running at low speed for two minutes to incorporate and properly wet the dry solids with liquid and at medium speed for five minutes for mixing. The resulting fresh grout was measured for three consecutive yield stress measurements. The cured grout was measured for set, bleed, and density. Given the conditions of preparing the grout in this task, all of the grouts were visually well mixed prior to preparing the grouts for measurements. All of the cured grouts were measured for bleed and set. All of the cured grouts satisfied the bleed and set requirements, where no bleed water was observed on any of the grout samples after one day and all had set within 3 days of curing. This data indicates, for a well mixed product, bleed and set requirement are satisfied for the range of acidic feeds tested in this task. The yield stress measurements provide both an indication on the mixability of the salt solution with dry materials and an indication of how quickly the grout is starting to form structure. The inability to properly mix these two streams into a well mixed grout product will lead to a non-homogeneous mixture that will impact product quality. Product quality issues could be unmixed regions of dry material and hot spots having high concentrations of americium 241. Mixes that were more difficult to incorporate typically resulted in grouts with higher yield stresses. The mixability from these tests will provide Waste Solidification Building (WSB) an indication of which grouts will be more challenging to mix. The first yield stress measurements were statistically compared to a list of variables, specifically the batched chemicals used to make the acidic solutions. The first yield stress was also compared to the physical properties of the acidic solutions, physical and pH properties of the neutralized/pH adjusted solutions, and chemical and physical properties of the grout.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Novel Thin Film Composite Nanofiltration Membrane Using Monoethanolamine (MEA) and Diethanolamine (DEA) with m-Phenylenediamine (MPD)

A novel thin-film composite (TFC) nanofiltration membrane was prepared by interfacial polymerization of polyamide layer on a polyethersulfone support, using monoethanolamine (MEA) and diethanolamine (DEA) with m-phenylenediamine as monomers and trimesoyl chloride (TMC) as crosslink agent. The membrane surface before and after using aminoalcohol monomers (MEA and DEA) was investigated in detail using ATR-FTIR, TGA, AFM and SEM. The AFM and SEM images showed that addition of MEA and DEA had a strong impact on surface morphology. The polyamide layer thickness of control and modified TFC membranes based on MEA and DEA were calculated to be in 180–230 nm range and the mean pore sizes were about 0.35–1.2 nm. The RO performance tests indicated that addition of MEA and DEA can increase the NaCl and Na{sub 2}SO{sub 4} rejection remarkably with little decline in the pure water permeation flux.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fracture Sustainability in Enhanced Geothermal Systems: Experimental and Modeling Constraints

Enhanced geothermal systems (EGS) offer the potential for a much larger energy source than conventional hydrothermal systems. Hot, low-permeability rocks are prevalent at depth around the world, but the challenge of extracting thermal energy depends on the ability to create and sustain open fracture networks. Laboratory experiments were conducted using a suite of selected rock cores (granite, metasediment, rhyolite ash-flow tuff, and silicified rhyolitic tuff) at relevant pressures (uniaxial loading up to 20.7 MPa and fluid pressures up to 10.3 MPa) and temperatures (150–250 °C) to evaluate the potential impacts of circulating fluids through fractured rock by monitoring changes in fracture aperture, mineralogy, permeability, and fluid chemistry. Because a fluid in disequilibrium with the rocks (deionized water) was used for these experiments, there was net dissolution of the rock sample: this increased with increasing temperature and experiment duration. Thermal-hydrological-mechanical-chemical (THMC) modeling simulations were performed for the rhyolite ash-flow tuff experiment to test the ability to predict the observed changes. These simulations were performed in two steps: a thermal-hydrological-mechanical (THM) simulation to evaluate the effects of compression of the fracture, and a thermal-hydrological-chemical (THC) simulation to evaluate the effects of hydrothermal reactions on the fracture mineralogy, porosity, and permeability. Furthermore, these experiments and simulations point out how differences in rock mineralogy, fluid chemistry, and geomechanical properties influence how long asperity-propped fracture apertures may be sustained. Such core-scale experiments and simulations can be used to predict EGS reservoir behavior on the field scale.

15 GEOTHERMAL ENERGY↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 07: A mould room in a box – 3D scanning and printing technology in the radiotherapy clinic

Purpose: We describe the process by which our centre is currently implementing 3D printing and scanning technology for treatment accessory fabrication. This technology can increase efficiency and accuracy of accessory design, production and placement during daily use. Methods: A low-cost 3D printer and 3D optical scanner have been purchased and are being commissioned for clinical use. Commissioning includes assessing: the accuracy of the 3D scanner through comparison with high resolution CT images; the dosimetric characteristics of polylactic acid (PLA) for electron beams; the clinical utility of the technology, and; methods for quality assurance. Results: The agreement between meshes generated using the 3D scanner and CT data was within 2 millimeters for an anthropomorphic head phantom. In terms of electron beam attenuation, 1 centimetre of printed PLA was found equivalent to 1.17 cm of water. In proof-of-concept tests, several types of treatment accessories have been prototyped to date that will benefit from this technology. These include electron and photon bolus for areas with complex surface contours including the ear for electron treatments, the extremities for photon treatments and lead shielding for orthovoltage treatments. Imaging with CT and x-ray showed minimal defects, which will have no significant clinical impact. Geometric fidelity and fit to volunteers and patients was found to be excellent. Conclusions: 3D Printing and scanning can increase efficiency in the clinic for treatments requiring custom accessories. Customized boluses and shielding had excellent fit and reduced uncertainty in positioning.

60 APPLIED LIFE SCIENCES↗