Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ultrasonic Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Hidden impact damage in thick composites

NASA is developing light-weight graphite/epoxy filament-wound cases (FWC) for the solid rocket motors of the Space Shuttle. The 12-foot-diameter FWC's are about 1.4 inches or more thick. Tests were conducted to determine the tension strength of an FWC after low-velocity impact. Impactors of various kinetic energies, masses, and shapes were used. The conditions that give minimum visual evidence of damage were emphasized. The capability to characterize impact damage with radiography and ultrasonic attenuation was also evaluated. After impact, the specimens were loaded uniaxially in tension to determine residual strengths.

Poe, C. C., Jr.↗

Characterization of damage modes in impacted thermoset and thermoplastic composites

Composite materials remain extremely vulnerable to out-of-plane impact loads, which may lead to severe losses in strength and stiffness. Impact induced damage is often a complex mixture of transverse cracks, delaminations and fiber failures. An experimental investigation was undertaken to quantify damage tolerance and resistance in composite materials impacted using the drop-weight method. Tests were conducted on laminates of several different carbon-fiber composite systems such as epoxies, modified epoxies, and amorphous and semicrystalline thermoplastics. In this paper, impacted composite specimens have been examined using destructive and nondestructive techniques to establish the characteristic damage states. Specifically, optical microscopy, ultrasonic and scanning electron microscopy techniques have been used to identify impact induced damage mechanisms. Damage propagation during post impact compression was also studied.

Srinivasan, K.↗

Ultrasonic Assessment of Impact-Induced Damage and Microcracking in Polymer Matrix Composites

The main objective of this NASA Faculty Awards for Research (FAR) project is to conduct ultrasonic assessment of impact-induced damage and microcracking in fiber-metal laminated (FML) composites at various temperatures. It is believed that the proposed study of impact damage assessment on FML composites will benefit several NASA's missions and current interests, such as ballistic impact testing of composite fan containment and high strain rate deformation modeling of polymer matrix composites. Impact-induced damage mechanisms in GLARE and ARALL fiber-metal laminates subject to instrumented drop-weight impacts at various temperatures were studied. GLARE and ARALL are hybrid composites made of alternating layers of aluminum and glass- (for GLARE) and aramid- (for ARALL) fiber reinforced epoxy. Damage in pure aluminum panels impacted by foreign objects was mainly characterized by large plastic deformation surrounding a deep penetration dent. On the other hand, plastic deformation in fiber-metal laminates was often not as severe although the penetration dent was still produced. The more stiff fiber-reinforced epoxy layers provided better bending rigidity; thus, enhancing impact damage tolerance. Severe cracking, however, occurred due to the use of these more brittle fiber-reinforced epoxy layers. Fracture patterns, e.g., crack length and delamination size, were greatly affected by the lay-up configuration rather than by the number of layers, which implies that thickness effect was not significant for the panels tested in this study. Immersion ultrasound techniques were then used to assess damages generated by instrumented drop-weight impacts onto these fiber-metal laminate panels as well as 2024-T3 aluminum/cast acrylic sandwich plates adhered by epoxy. Depending on several parameters, such as impact velocity, mass, temperature, laminate configuration, sandwich construction, etc., various types of impact damage were observed, including plastic deformation, radiating cracks emanating from the impact site, ring cracks surrounding the impact site, partial and full delamination, and combinations of these damages.

Gyekanyesi, John↗

Phase Calibration of Microphones by Measurement in the Free-field

Over the past several years, significant effort has been expended at NASA Langley developing new Micro-Electro-Mechanical System (MEMS)-based microphone directional array instrumentation for high-frequency aeroacoustic measurements in wind tunnels. This new type of array construction solves two challenges which have limited the widespread use of large channel-count arrays, namely by providing a lower cost-per-channel and a simpler method for mounting microphones in wind tunnels and in field-deployable arrays. The current generation of array instrumentation is capable of extracting accurate noise source location and directivity on a variety of airframe components using sophisticated data reduction algorithms [1-2]. Commercially-available MEMS microphones are condenser-type devices and have some desirable characteristics when compared with conventional condenser-type microphones. The most important advantages of MEMS microphones are their size, price, and power consumption. However, the commercially-available units suffer from certain important shortcomings. Based on experiments with array prototypes, it was found that both the bandwidth and the sound pressure limit of the microphones should be increased significantly to improve the performance and flexibility of the microphone array [3]. It was also desired to modify the packaging to eliminate unwanted Helmholtz resonance s exhibited by the commercial devices. Thus, new requirements were defined as follows: Frequency response: 100 Hz to 100 KHz (+/-3dB) Upper sound pressure limit: Design 1: 130 dB SPL (THD less than 5%) Design 2: 150-160 dB SPL (THD less than 5%) Packaging: 3.73 x 6.13 x 1.3 mm can with laser-etched lid. In collaboration with Novusonic Acoustic Innovation, NASA modified a Knowles SiSonic MEMS design to meet these new requirements. Coupled with the design of the enhanced MEMS microphones was the development of a new calibration method for simultaneously obtaining the sensitivity and phase response of the devices over their entire broadband frequency range. Traditionally, electrostatic actuators (EA) have been used to characterize air-condenser microphones; however, MEMS microphones are not adaptable to the EA method due to their construction and very small diaphragm size [4]. Hence a substitution based, free-field method was developed to calibrate these microphones at frequencies up to 80 kHz. The technique relied on the use of a random, ultrasonic broadband centrifugal sound source located in a small anechoic chamber. The free-field sensitivity (voltage per unit sound pressure) was obtained using the procedure outlined in reference 4. Phase calibrations of the MEMS microphones were derived from cross spectral phase comparisons between the reference and test substitution microphones and an adjacent and invariant grazing-incidence 1/8-inch standard microphone. The free-field calibration procedure along with representative sensitivity and phase responses for the new high-frequency MEMS microphones are presented here.

Shams, Qamar A.↗

Current Status of Martian Moons eXploration (MMX) Contamination Control and Curation Activity

Martian Moons eXploration (MMX) is a sample return mission from the Martian moon Phobos. The MMX spacecraft is scheduled to launch in 2026 and return to Earth in 2031. The main science goals of MMX are “to reveal the origin of the Martian moons and make progress in the understanding of planetary system formation and material transport in the solar system, and to observe processes that impact the circumplanetary and surface environments of Mars”. MMX has two sampling systems: coring (C)-sampler and pneumatic (P)-sampler and plans to bring back >10 g of Phobos sample. The retuned sample in the sample capsule will be transferred to the curation facility in ISAS/JAXA for sample curation and subsequent sample analysis. Contamination control of the sample return mission requires special care to prevent terrestrial contamination to the spacecraft, which would ruin the scientific value of the returned sample. Retaining the pristineness of the retuned sample is an important task of the MMX Curation and Sampler Science teams. The basis of the contamination control is (1) to minimize and understand the nature and amount of contaminants, (2) to perform contamination assessment and evaluate the effect of contaminants in the spacecraft on the retuned sample, (3) to employ a contamination knowledge (CK) material coupon in the spacecraft to identify the contaminants in the returned samples. In the MMX contamination control plan, the allowable contamination level for each contaminant is carefully defined. They are mostly set to be 1/1000 of the expected amount of each material in the returned sample and are divided into two main categories: organic and inorganic. The allowable atmospheric leakage rate to the sample container is also defined. The allowable contamination level of the organic materials is based on the composition of carbonaceous chondrites. The target contaminants are amino acids, aliphatic and aromatic hydrocarbons, carboxylic acids, etc. In case of the inorganic materials, the target contaminants are important elements to permit distinguishing the origin of the Martian moon by nucleosynthetic isotope anomalies (Cr, Ti, and Mo) and to reveal the evolution of the Martian moon by chronology (Hf, W, U, Pb, Rb, Sr, Sm, and Nd). The key instrument of contamination control in the sample return mission is the sampler system. The C-sampler has been developed by JAXA and the P-sampler was provided by Honeybee/NASA. In MMX, materials used in the two samplers (C- and P- sampler) were carefully selected to avoid potential contamination from the design stage of the system. The individual parts of the C-sampler FM (Flight Model) were thoroughly cleaned at the curation facility in ISAS/JAXA by the full-course cleaning procedure, which is an ultrasonic cleaning with organic solvents and ultrapure water in several steps. The equivalent level of cleaning was also carried out on the P-Samper FM as well by Honeybee Robotics in the USA. Now, MMX is in the critical phase for contamination control called ATLO: Assembly, Test, and Launch Operations. During the ATLO phase, sampler FM is constantly purged with nitrogen gas and maintained at positive pressure to prevent environmental contamination. The surrounding environments of the sampler FM are also simultaneously monitored using the CK Monitoring Coupon Set, which consists of several witness materials such as a glass petri dish, sapphire glass disk, and carbon adhesive tape (Figure 1). The detailed environmental assessment of each clean room used for the assembly and test of the sampler FM has also been conducted. This assessment includes microbial analysis, which was performed for OSIRIS-REx. Regarding the sample recovery and sample curation, we have started the designing of Sample Container Disassembling Instrument for the sample recovery from the sample container and the MMX curation chamber for sample curation. The curation protocol for the Phobos returned sample has also been discussed by the MMX Sample Analysis Working Team (SAWT). The MMX curation protocol consists of three phases: (1) quick analysis, (2) pre-basic characterization, and (3) basic characterization. (1) is extraction of the sample gas from the sample container and analysis by mass spectrometry, (2) is observation in bulk level, and (3) is observation in grain level and allocation of the sample aliquots. In parallel with the curation protocol, the returned sample undergoes preliminary examination for scientific investigations to achieve science goals. In addition, the CK witness plates made of sapphire glass are on board the sampler system. The CK witness plates will be recovered from the sampler system and analyzed by SAWT for the assessment of in-flight contamination.

Haruna Sugahara↗

Preparation and Characterization Methods of Thin Layer Samples for Standoff Detection

Detection of analytes deposited on surfaces is crucial for many applications: Development of methods to prepare thin layers (e.g. ~5 to 100 µm) is important for both system design and field studies. In this work, solid and liquid analytes were deposited on painted and bare substrates including aluminum, glass, plastic, and concrete using an ExactaCoat ultrasonic spray coater. Laboratory hemispherical reflectance (HRF) spectra were collected for samples with different layer thicknesses so as to characterize both the composition and layer thickness. Preliminary results demonstrate that to prepare homogenous layers on surfaces, parameters such as substrate type, analyte solubility, vapor pressure, paint color, surface porosity, and surface roughness are all important. Liquid chemicals posed several issues during deposition: Diisopropyl methyl phosphonate evaporated from surfaces more quickly than the other chemicals and was thus not detected in the HRF experiments. Less volatile liquids, such as tributylphosphate, remained on the surface for the duration of the test, but a uniform layer thickness could not be obtained as the liquid pooled to one side when mounted at an angle. The deposition of solids (e.g., acetaminophen, caffeine and methylphosphonic acid) from volatile solvents such as chloroform also proved problematic due to streaking caused by rapid solvent evaporation. Solids deposited from ethanol, however, worked well on bare substrates. For most samples plotting the integrated infrared band strength vs. surface thicknesses showed a linear relationship, confirming that the surface loading can be controlled by programming the concentration and the number of passes on the ultrasonic sprayer.

Thin layer, deposition, infrared standoff, Hemisph↗

NASA Tech Briefs, November 2011

The topics include: 1) Flight Test Results from the Rake Airflow Gage Experiment on the F-15B; 2) Telemetry and Science Data Software System; 3) CropEx Web-Based Agricultural Monitoring and Decision Support; 4) High-Performance Data Analysis Tools for Sun-Earth Connection Missions; 5) Experiment in Onboard Synthetic Aperture Radar Data Processing; 6) Microfabrication of a High-Throughput Nanochannel Delivery/Filtration System; 7) Improved Design and Fabrication of Hydrated-Salt Pills; 8) Monolithic Flexure Pre-Stressed Ultrasonic Horns; 9) Cryogenic Quenching Process for Electronic Part Screening; 10) Broadband Via-Less Microwave Crossover Using Microstrip-CPW Transitions; 11) Wheel-Based Ice Sensors for Road Vehicles; 12) G-DYN Multibody Dynamics Engine; 13) Multibody Simulation Software Testbed for Small-Body Exploration and Sampling; 14) Propulsive Reaction Control System Model; 15) Licklider Transmission Protocol Implementation; 16) Core Recursive Hierarchical Image Segmentation; 17) Two-Stage Centrifugal Fan; 18) Combined Structural and Trajectory Control of Variable-Geometry Planetary Entry Systems; 19) Pressure Regulator With Internal Ejector Circulation Pump, Flow and Pressure Measurement Porting, and Fuel Cell System Integration Options; 20) Temperature-Sensitive Coating Sensor Based on Hematite; 21) Standardization of a Volumetric Displacement Measurement for Two-Body Abrasion Scratch Test Data Analysis; 22) Detection of Carbon Monoxide Using Polymer-Carbon Composite Films; 23) Substituted Quaternary Ammonium Salts Improve Low-Temperature Performance of Double-Layer Capacitors; 24) Sustainably Sourced, Thermally Resistant, Radiation Hard Biopolymer; 25) Integrated Lens Antennas for Multi-Pixel Receivers; 26) 180-GHz Interferometric Imager; 27) Maturation of Structural Health Management Systems for Solid Rocket Motors; 28) Validating Phasing and Geometry of Large Focal Plane Arrays; 29) Transverse Pupil Shifts for Adaptive Optics Non-Common Path Calibration; 30) Qualification of Fiber Optic Cables for Martian Extreme Temperature Environments; 31) Solid-State Spectral Light Source System; 32) Multiple-Event, Single-Photon Counting Imaging Sensor; 33) Surface Modeling to Support Small-Body Spacecraft Exploration and Proximity Operations; and 34) Achieving Exact and Constant Turnaround Ratio in a DDS-Based Coherent Transponder.

Source record↗

Ultrasonic Monitor

MicroUltrasonics PLR-1000 is a refined microprocessor-controlled version (usable on bolts, plates, liquids and gases) of the P2L2 developed by Langley Research Center. New technique is for nondestructive measurement of residual stress in various types of structures, for example, nuclear pressure vessels, pipes in nuclear reactors, offshore platforms, bridges, railroad tracks and wheels, aircraft wings, and engines. The instrument produces sound tone pulses that travel through a test specimen. PLR-1000 precisely measures speeds as stress increases speed of sound, tone changes, making precise measurements possible.

Source record↗

Ultrasonic Dynamic Vector Stress Sensor

Stress inferred from measurements in specimens rather than in bonded gauges. Ultrasonic dynamic vector stress sensor (UDVSS) measures changes in dynamic directional stress occurring in material or structure at location touched by device when material or structure put under cyclic load. Includes phase-locked loop, synchronous amplifier, and contact probe. Useful among manufacturers of aerospace and automotive structures for stress testing and evaluation of designs.

Heyman, Joseph S.↗

NASA Tech Briefs, March 2006

Topics covered include: Medical Signal-Conditioning and Data-Interface System; Instruments for Reading Direct-Marked Data-Matrix Symbols; Processing EOS MLS Level-2 Data; Ground Processing of Data From the Mars Exploration Rovers; Estimating Total Electron Content Using 1,000+ GPS Receivers; NASA Solar Array Demonstrates Commercial Potential; Improved Control of Charging Voltage for Li-Ion Battery; Programmable Pulse-Position-Modulation Encoder; Wavelength-Agile External-Cavity Diode Laser for DWDM; Pattern-Recognition Processor Using Holographic Photopolymer; Submicrosecond Power-Switching Test Circuit; Three-Function Logic Gate Controlled by Analog Voltage; Integrated System for Autonomous Science; Montage Version 3.0; Utilizing AI in Temporal, Spatial, and Resource Scheduling; Satellite Image Mosaic Engine; Architecture for Control of the K9 Rover; HFGMC Enhancement of MAC/GMC; Automated Activation and Deactivation of a System Under Test; Cleaning Carbon Nanotubes by Use of Mild Oxygen Plasmas; Generating Aromatics From CO2 on Mars or Natural Gas on Earth; Attaching Thermocouples by Peening or Crimping; Heat Treatment of Friction-Stir-Welded 7050 Aluminum Plates; Generating Breathable Air Through Dissociation of N2O; High-Performance Scanning Acousto-Ultrasonic System; Correction for Thermal EMFs in Thermocouple Feedthroughs; Using Quasiparticle Poisoning To Detect Photons; Estimating Resolution Lengths of Hybrid Turbulence Models; Education and Training Module in Alertness Management; Cargo-Positioning System for Next-Generation Spacecraft; Micro-Imagers for Spaceborne Cell-Growth Experiments; Holographic Solar Photon Thrusters; Plasma-Based Detector of Outer-Space Dust Particles; and Generation of Data-Rate Profiles of Ka-Band Deep-Space Links.

Source record↗

Functional fiber-optic sensors embedded in stainless steel components using ultrasonic additive manufacturing for distributed temperature and strain measurements

The nuclear industry is progressing toward microreactors that can be factory assembled and deployed to remote regions for reliable, scalable power generation. However, the reduced power output requires enhanced monitoring capabilities to reduce staffing and eventually move toward autonomous control to improve the economics of microreactors. The ability to embed sensors such as fiber-optics, which can provide spatially distributed temperature and strain measurements, within microreactor components for real-time health monitoring would be particularly advantageous. Recent advances in ultrasonic additive manufacturing (UAM) have demonstrated the successful embedding of fiber-optics in soft materials such as Al and Cu by placing the sensors in machined cavities and ultrasonically welding over the top with thin foils. This article reports the first successful embedment of fiber-optic sensors and thermocouples within a common nuclear reactor material, SS304, via UAM. UAM parameters were first explored with simple plate geometries before moving to more complex geometries, such as pipes and other test articles for heat pipe–based microreactors. Select samples were sectioned for microscopy to evaluate the sensor/foil and foil/foil interfaces from samples fabricated by using 100% SS304 foils vs. foils plated with a Ni coating to improve UAM bonding. Furthermore, embedding metal-coated, low-bend loss fibers resulted in greatly reduced signal attenuation and adequate compressive residual strain in the embedded region to ensure successful strain coupling. Pipe specimen functional testing was performed by monitoring temperature and strain during transient and steady-state thermal testing.

36 MATERIALS SCIENCE↗

Reducing Wear of Steel Rolling Against Ti6Al4V Operating in Vacuum

This work was motivated by a qualification test of a mechanism for a space telescope. During the test undesired wear debris was formed. In this project alterative materials and coatings were tested with intent to reduce wear and debris when steel has a misaligned rolling contact against Ti6Al4V. Testing was done using a vacuum roller rig mimicking the mechanism's contact conditions. Ten configurations were tested. Most configurations resulted in significant debris. A sputtered 1-micrometer-thick nan-ocomposite molybdenum disulfide (MoS2) film provided the best wear protection. The best configuration made use of the MoS2 coating on both materials, and in preparing for sputtering the anodized Ti6Al4V working surface was smoothed using an ultrasonic process.

Krantz, Timothy L.↗

Solid-State Joining of Magnesium Sheet to High-Strength Steel

Increasing the use of lightweight materials and implementing enabling manufacturing technologies are the two primary paths toward automotive weight reduction. In many situations, the ability to substitute light weight material requires a need to attach and join light weight material to existing steel substructures requiring dissimilar joining technologies. Dissimilar joining methods currently available in cost range for high volume automotive manufacturing face multiple challenges. The problem is exacerbated in the case of Magnesium alloy to steel joints because of their highly dissimilar nature and lack of mutual miscibility. Additionally, Magnesium’s poor room temperature ductility complicates the use of point fastening technologies. Two emerging solid-state joining technologies Friction Stir assisted Scribe welding (FaST) and Ultrasonic Welding (USW) that employ large amount of plastic deformation at the interface were used to investigate, develop, and understand dissimilar joints between Magnesium Alloy to DP590 Steel. Various process responses including interface temperatures, process forces, strain fields were captured during the development of the welding process. Variety of welded samples were tested and characterized to understand the relationship between welding conditions and joints microstructure and mechanical properties.

36 MATERIALS SCIENCE↗

A transmission oscillator ultrasonic spectrometer

A continuous wave ultrasonic instrument capable of measuring very small changes in acoustic attenuation and phase velocity is described. This transmission oscillator ultrasonic spectrometer (TOUS) exhibits high sensitivity because it oscillates marginally. In spite of this high sensitivity, the TOUS system is relatively simple, compact, and inexpensive. These features suggest that the TOUS is suitable not only for precise laboratory measurements of the physical properties of materials, but also for field applications in nondestructive testing.

Conradi, M. S.↗

Percussive Augmenter of Rotary Drills (PARoD)

A percussive augmenter is being developed and it is designed to add ultrasonic hammering to a conventional commercial rotary drill through an adapter using a piezoelectric actuator. The combination of ultrasonic hammering and rotation creates a drill that requires low power and low axial load while providing faster penetration than conventional rotary-only drills. These characteristics make percussive augmentation of rotary drills ideal for not only planetary exploration but commercial applications as well. The purpose of this internship was to produce, test, and optimize an augmenter that drives a 2 inch diameter bit. This task was part of the percussive augmenter's phase II of an ongoing contract and it involved increasing the capability of the .25 inch version of the augmenter prototype that was developed in phase I. Due to fabrication delays of the augmenter, an extensive part of the test effort was conducted using previous rotary and hammer drill prototypes. These tests focused on drilling deep over long periods of time to provide for effective stress test of the drill. Modifications were made to the drill, its components, and the testing procedure to achieve desired borehole depths. These results were used to start initial testing on the 2 inch augmenter and provide preliminary data on the augmenter's ability to significantly improve penetration rate over conventional rotary-only drills.

rotraty hammer↗

Thermography Inspection for Detection and Tracking of Composite Cylinder Damage During Load Testing

Two thermography techniques, passive and active, are used to detect damage initiation and progression in a cyclically loaded composite cylinder. The passive thermography tracks damage progression in real time during cyclic loading. Active flash thermography, using a flash tube enclosed within the cylinder, images delaminations in a cylinder under different loads. A differential thermography processing technique eliminates normal material variations and improves sensitivity to and sizing of delaminations. The thermography results were compared to nonimmersion ultrasonic results.

Zalameda, J. N.↗

TASK3 Laboratory Experiments Data

Laboratory Experiments Data of TASK3 of DOE project DE- FE0031686. Each signal has its own excel file. 150 signals are sent through the rock sample per each load configuration. There were approximately 50 to 150 load combinations tested during the experiments. Experiments were repeated after changing the polarity direction of the transducers. Signals of these repeats are in separate folders called "Reverse". There are three formations tested from the Michigan Core and four formations tested from the FutureGen site. The "Code" folder contains the Python code developed to analyze the signals. Large Dataset, please contact EDXSupport@netl.doe.gov

core↗

Apollo 6, Anomaly Report No. 6: Abnormal Structural Performance During Launch Phase

Approximately 2 minutes 13 seconds after lift-off of the Apollo 6 mission, abrupt changes of strain, vibration, and acceleration measurements were indicated in the S-IVB, instrument unit, adapter, lunar module, and command and service modules; photographs showed objects coming from the area of the adapter. The adapter, however, continued to sustain the required loads with no impairment of the mission. The investigation was first focused upon the understanding of the coupled vibration modes and characteristics of the launch vehicle and spacecraft.' Extensive test programs were conducted. It was eventually concluded that the adapter failure was not caused by vibration. Extensive study of the airborne photography and other evidence indicated that a large area of the adapter had lost inner facesheet from the honeycomb sandwich panels. Loads and stresses resulting from vibration were determined to be insufficient to initiate such a failure. The investigation was then directed toward determining the range of pressures that could have been trapped in the Apollo 6 adapter sandwich panels, and toward determining the tolerance of the panels to withstand pressure with various degrees of flaws such as adhesive voids and facesheet dents. The degradation effects of moisture and heat exposure on the adhesive strength were also studied and tested. These tests and analyses led to the conclusion that pressure internal to the sandwich panels could have caused the failure, if a large flaw existed. The pressure buildup would have been caused by aerodynamic heating effects on air and moisture trapped in the panel. The probable cause of the failure was found in the original ultrasonic inspection scan record of the affected adapter panel. In the center of the region where the adapter failed, horizontally along the station 709 panel splice, the record contained two thick anomalous lines extending several feet. Without an X-ray record of this region, the significance of this particular scan record cannot be fully understood. However, since all other evidence had indicated that the adhesive had to be weakened in a rather large area to initiate the failure, the investigation was focused intently upon the station 709 splices of other adapters. Sufficient information was developed to verify that deficient assembly techniques have consistently resulted in abnormalities in the structure at this station. These abnormalities were identified in adapters 12, 13, 14, 15, and 16. Before the splice abnormalities were pinpointed, corrective action was taken to reduce pressure "buildup in the honeycomb panels and to reduce heat degrading effects on the adhesive. This was done by drilling vent holes in the inner facesheet and covering the outer facesheet with cork. The adapters having identified abnormalities in the station 709 splice are being repaired, and the contractor is investigating ways of avoiding these -abnormalities in panels yet to be bonded.

Source record↗