Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transient Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Development and evaluation of the impulse transfer function technique

The development of the test/analysis technique known as the impulse transfer function (ITF) method is discussed. This technique, when implemented with proper data processing systems, should become a valuable supplement to conventional dynamic testing and analysis procedures that will be used in the space shuttle development program. The method can relieve many of the problems associated with extensive and costly testing of the shuttle for transient loading conditions. In addition, the time history information derived from impulse testing has the potential for being used to determine modal data for the structure under investigation. The technique could be very useful in determining the time-varying modal characteristics of structures subjected to thermal transients, where conventional mode surveys are difficult to perform.

Mantus, M.↗

Aeroelastic Modeling of a Nozzle Startup Transient

Lateral nozzle forces are known to cause severe structural damage to any new rocket engine in development during test. While three-dimensional, transient, turbulent, chemically reacting computational fluid dynamics methodology has been demonstrated to capture major side load physics with rigid nozzles, hot-fire tests often show nozzle structure deformation during major side load events, leading to structural damages if structural strengthening measures were not taken. The modeling picture is incomplete without the capability to address the two-way responses between the structure and fluid. The objective of this study is to develop a tightly coupled aeroelastic modeling algorithm by implementing the necessary structural dynamics component into an anchored computational fluid dynamics methodology. The computational fluid dynamics component is based on an unstructured-grid, pressure-based computational fluid dynamics formulation, while the computational structural dynamics component is developed under the framework of modal analysis. Transient aeroelastic nozzle startup analyses at sea level were performed, and the computed transient nozzle fluid-structure interaction physics presented,

Wang, Ten-See↗

Evaluation of BISON's Transient Fission Gas Release Model on High-Burnup UO 2 MiniFuel

BISON's fission gas release (FGR) model has been evaluated and tested over several hypothetical thermal transient cases at high burnup and validated against FGR experimental data from an annealing test at high burnup. Diffusion-controlled FGR is accounted for in the model by including several physical mechanisms such as the diffusion of fission gas to grain faces, grain boundary sweeping, grain growth, and intergranular bubble growth. Under temperature variations, FGR is increased due to the development of micro-cracks at grain faces. This existing transient capability, however, was developed based on transient fuel behavior during power ramps and the associated micro-cracking process. Nevertheless, a fraction of the FGR during temperature transients such as LOCA can ensue from different mechanisms (in particular, fuel fragmentation) and present an important dependency on local burnup and high burnup structure formation. It follows that the performance and necessary developments of the existing BISON fission gas model for the analysis of LOCA-type transients need to be investigated through a systematic assessment study. Such a study is performed in this work. The model shows an overall good qualitative agreement with experimental observations on FGR during annealing tests with different temperature conditions. It also accounts well for microstructural effects on FGR. When quantitatively compared to FGR data from previously irradiated 103 MWd/kgU UO 2 discs under thermal annealing, the model shows a less satisfactory agreement with the experimental data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modular high temperature gas reactor core modeling with RELAP5-3D/PHISICS – Optimization schemes for load following

The objective of this study is to develop a 3D/NK model to study the load following operation of a Modular High-Temperature Gas-Cooled Reactor (MHTGR). The selected design is the 350 MW prismatic, graphite moderated, helium cooled thermal reactor based on the MHTGR-350 transient benchmark led by the High-Temperature Gas-Cooled Reactor (HTGR) Methods Core Simulation Group at Idaho National Laboratory (INL) in the framework of the Organization for Economic Cooperation and Development Nuclear Energy Agency (OECD/NEA). This kind of reactor usually reacts very slowly to the perturbation of the core parameters due to the large amount of graphite in the core. This kind of behavior promotes the reactor stability but on the other hand limits the reactor load-following operability. Recently advances in gas reactor designs have made load-following in gas reactors a feasible and achievable goal. Modern nuclear reactors (such as the MHTGR-350) are designed to withstand the structural stresses associated with load-following. Operating the reactor in load-following mode will inevitably reduce the load factor. Although a higher load factor means more revenue and the best usage of the fuel, following the variable energy demand will increase the maximum achievable fraction of generated nuclear power, being no more limited to the base load power generation. In general, if low impact on material aging and the safe operability are demonstrated the plant economics will be minimally affected. In order to ensure that the system can be safely operated in a load-following mode an extensively study has been carried out. Some tests with linear coolant mass flow rate change demonstrated that the reactor behavior is suitable for operation in load following mode. This assumption has been confirmed by a 4 days load following transient test in which the reactor supplied the requested power with a negligible error.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Utility of Bromide and Heat Tracers for Aquifer Characterization Affected by Highly Transient Flow Conditions

A tracer test using both bromide and heat tracers conducted at the Integrated Field Research Challenge site in Hanford 300 Area (300A), Washington, provided an instrument for evaluating the utility of bromide and heat tracers for aquifer characterization. The bromide tracer data were critical to improving the calibration of the flow model complicated by the highly dynamic nature of the flow field. However, most bromide concentrations were obtained from fully screened observation wells, lacking depth-specific resolution for vertical characterization. On the other hand, depth-specific temperature data were relatively simple and inexpensive to acquire. However, temperature-driven fluid density effects influenced heat plume movement. Moreover, the temperature data contained “noise” caused by heating during fluid injection and sampling events. Using the hydraulic conductivity distribution obtained from the calibration of the bromide transport model, the temperature depth profiles and arrival times of temperature peaks simulated by the heat transport model were in reasonable agreement with observations. This suggested that heat can be used as a cost-effective proxy for solute tracers for calibration of the hydraulic conductivity distribution, especially in the vertical direction. However, a heat tracer test must be carefully designed and executed to minimize fluid density effects and sources of noise in temperature data. A sensitivity analysis also revealed that heat transport was most sensitive to hydraulic conductivity and porosity, less sensitive to thermal distribution factor, and least sensitive to thermal dispersion and heat conduction. This indicated that the hydraulic conductivity remains the primary calibration parameter for heat transport.

Ma, Rui↗

System for measuring transients in fluid flow

When test valve is actuated, piston is moved by pressurized fluid, and displacement is monitored by electro-optical tracking system and recorded by oscilloscope camera. Electro-optical monitor produces output voltage proportional to displacement of piston.

Pearson, D. J.↗

Vibration Performance Comparison Study on Current Fiber Optic Connector Technologies

Fiber optic cables are increasingly being used in harsh environments where they are subjected to vibration. Understanding the degradation in performance under these conditions is essential for integration of the fibers into the given application. System constraints oftentimes require fiber optic connectors so subsystems can be removed or assembled as needed. In the present work, various types of fiber optic connectors were monitored in-situ during vibration testing to examine the transient change in optical transmission and the steady-state variation following the event. Inspection of the fiber endfaces and connectors was performed at chosen intervals throughout the testing.

Ott, Melanie N.↗

Development of a Cryogenic Thermal Distortion Measurement Facility for Testing the James Webb Space Telescope Instrument Support Integration Module 2-D Test Assemblies

The James Webb Space Telescope Instrument Support Integration Module (ISIM) is being designed and developed at the Goddard Space Flight Center. The ISM Thermal Distortion Testing (ITDT) program was started with the primary objective to validate the ISM mechanical design process. The ITDT effort seeks to establish confidence and demonstrate the ability to predict thermal distortion in composite structures at cryogenic temperatures using solid element models. This-program's goal is to better ensure that ISIM meets all the mechanical and structural requirements by using test results to verify or improve structural modeling techniques. The first step to accomplish the ITDT objectives was to design, and then construct solid element models of a series 2-D test assemblies that represent critical building blocks of the ISIM structure. Second, the actual test assemblies consisting of composite tubes and invar end fittings were fabricated and tested for thermal distortion. This paper presents the development of the GSFC Cryo Distortion Measurement Facility (CDMF) to meet the requirements of the ISIM 2-D test. assemblies, and other future ISIM testing needs. The CDMF provides efficient cooling with both a single, and two-stage cryo-cooler. Temperature uniformity of the test assemblies during thermal transients and at steady state is accomplished by using sapphire windows for all of the optical ports on the radiation shields and by using .thermal straps to cool the test assemblies. Numerical thermal models of the test assemblies were used to predict the temperature uniformity of the parts during cooldown and at steady state. Results of these models are compared to actual temperature data from the tests. Temperature sensors with a 0.25K precision were used to insure that test assembly gradients did not exceed 2K lateral, and 4K axially. The thermal distortions of two assemblies were measured during six thermal cycles from 320K to 35K using laser interferometers. The standard deviation for all of the distortion measurements is less than 0.5 microns, which falls within the ISIM requirement of 3 microns.

Miller, Franklin↗

Impact Testing and Simulation of a Sinusoid Foam Sandwich Energy Absorber

A sinusoidal-shaped foam sandwich energy absorber was developed and evaluated at NASA Langley Research Center through multi-level testing and simulation performed under the Transport Rotorcraft Airframe Crash Testbed (TRACT) research project. The energy absorber, designated the "sinusoid," consisted of hybrid carbon- Kevlar® plain weave fabric face sheets, two layers for each face sheet oriented at +/-45deg with respect to the vertical or crush direction, and a closed-cell ELFOAM(TradeMark) P200 polyisocyanurate (2.0-lb/ft3) foam core. The design goal for the energy absorber was to achieve an average floor-level acceleration of between 25- and 40-g during the full-scale crash test of a retrofitted CH-46E helicopter airframe, designated TRACT 2. Variations in the design were assessed through quasi-static and dynamic crush testing of component specimens. Once the design was finalized, a 5-ft-long subfloor beam was fabricated and retrofitted into a barrel section of a CH-46E helicopter. A vertical drop test of the barrel section was conducted onto concrete to evaluate the performance of the energy absorber prior to retrofit into TRACT 2. Finite element models were developed of all test articles and simulations were performed using LSDYNA ®, a commercial nonlinear explicit transient dynamic finite element code. Test analysis results are presented for the sinusoid foam sandwich energy absorber as comparisons of load-displacement and acceleration-time-history responses, as well as predicted and experimental structural deformations and progressive damage for each evaluation level (component testing through barrel section drop testing).

Jackson, Karen E.↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

ABSTRACT: Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Effect of transient winds on the flow quality of an open-circuit wind-tunnel model

The effect of a transient wind on the test-section flow quality of an open-circuit wind tunnel was investigated experimentally. The investigation was restricted to transient wind effects associated with the inlet. A small open-circuit wind tunnel was placed outside in the real wind environment. Test-section speed and angularity as well as wind speed and direction was measured by high-response instrumentation. The inlet configuration was varied with a set of screens, a removable honeycomb, and a removable inlet lip. Acceptable flow was obtained at all wind angles and for wind- to test-section-velocity ratios up to 0.4 with an inlet configuration having five screens, a honeycomb, and a lip. With inlet configurations sensitive to winds, a transient wind parallel to the tunnel axis produced local fluctuations in test-section speed and angularity; however, oscillation of the average test-section speed was not evident. The effect of wind direction was negligible up to wind angles of 45 deg relative to the tunnel axis. At larger wind angles, flow distortions occurred primarily on the windward side of the test section.

Breunlin, D. C.↗

Tundra SGS – Critical Importance of Site-Specific Injectivity Testing for Carbon Dioxide Injection Well Simulation Calibration

Paper presented at 16th International Conference on Greenhouse Gas Control Technologies (GHGT-16), October 23–27, 2022, Lyon, France. Brine injectivity tests were conducted on both the Broom Creek (BC) and Deadwood (DW) storage formations in one of the cored stratigraphic test wells prior to finalized simulations. The injectivity tests entailed injection of brine into the formations, followed by shutting in the wells. The shut-in duration represents the fall-off period which was used to carry out pressure transient analyses of the tests. The analysis of injectivity tests indicated that core-indicated and modeled permeability distributions should be conservatively multiplied by 2.5× and 5× in the BC and DW geologic models, respectively, prior to numerical simulations of CO 2 injection using Computer Modelling Group’s (CMG’s) GEM equation-of-state reservoir simulator. The scaler permeability multipliers allowed the fluid flow simulations to fully represent well test-measured injection well rates in the respective formations.

20 FOSSIL-FUELED POWER PLANTS↗

Direct Utilization of Coal Syngas in High Temperature Fuel Cells

This EPSCoR project had two primary goals: (i) to build infrastructure and work force at WVU to support long-term research in the area of fuel cells and related sciences; (ii) study effects of various impurities found in coal-syngas on performance of Solid Oxide Fuel Cells (SOFC). As detailed in this report the WVU research team has made significant accomplishments in both of these areas. What follows is a brief summary of these accomplishments: State-of-the-art test facilities and diagnostic tools have been built and put into use. These include cell manufacturing, half-cell and full-cell test benches, XPS, XRD, TEM, Raman, EDAX, SEM, EIS, and ESEM equipment, unique in-situ measurement techniques and test benches (Environmental EM, Transient Mass-Spectrometer-MS, and IR Optical Temperature measurements). In addition, computational capabilities have been developed culminating in a multi-scale multi-physics fuel cell simulation code, DREAM-SOFC, as well as a Beowulf cluster with 64 CPU units. We have trained 16 graduate students, 10 postdoctoral fellows, and recruited 4 new young faculty members who have actively participated in the EPSCoR project. All four of these faculty members have already been promoted to the tenured associate professor level. With the help of these faculty and students, we were able to secure 14 research awards/contracts amounting to a total of circa $5.0 Million external funding in closely related areas of research. Using the facilities mentioned above, the effects of PH3, HCl, Cl2, and H2S on cell performance have been studied in detail, mechanisms have been identified, and also remedies have been proposed and demonstrated in the laboratory. For example, it has been determined that PH3 reacts rapidly with Ni to from secondary compounds which may become softer or even melt at high temperature and then induce Ni migration to the surface of the cell changing the material and micro-structural properties of the cell drastically. It is found that the extent of steam and current load accelerate the degradation caused by PH3. A unique filtering technique has been proposed to reduce the effect of PH3. In addition, various cell materials have been proposed to reduce the rate of degradation caused by H2S. Furthermore, a three-dimensional, transient multi-physics model has been formulated to describe primary transport processes and electro-chemical reactions occurring within the cell. This model has been validated using data gathered from accelerated tests. The validated model then has been used to study the degradation rates under a range of operating conditions and impurity levels. This has resulted in a procedure that uses both experiments and simulations to predict the life-time of a cell operating with syngas with known concentration of trace impurities. Finally all the experience and knowledge gained has been disseminated via 39 journal papers and 43 presentations/posters/conference papers.

01 COAL, LIGNITE, AND PEAT↗

Simulation of IST Turbomachinery Power-Neutral Tests with the ANL Plant Dynamics Code

The validation of the Plant Dynamics Code (PDC) developed at Argonne National Laboratory (ANL) for the steady-state and transient analysis of supercritical carbon dioxide (sCO2) systems has been continued with new test data from the Naval Nuclear Laboratory (operated by Bechtel Marine Propulsion Corporation) Integrated System Test (IST). Although data from three runs were provided to ANL, only two of the data sets were analyzed and described in this report. The common feature of these tests is the power-neutral operation of the turbine-compressor shaft, where no external power through the alternator was provided during the tests. Instead, the shaft speed was allowed to change dictated by the power balance between the turbine, the compressor, and the power losses in the shaft. The new test data turned out to be important for code validation for several reasons. First, the power-neutral operation of the shaft allows validation of the shaft dynamics equations in asynchronous mode, when the shaft is disconnected from the grid. Second, the shaft speed control with the compressor recirculation (CR) valve not only allows for testing the code control logic itself, but it also serves as a good test for validation of both the compressor surge control and the turbine bypass control actions, since the effect of the CR action on the loop conditions is similar for both of these controls. Third, the varying compressor-inlet temperature change test allows validation of the transient response of the precooler, a shell-and-tube heat exchanger. The first transient simulation of the compressor-inlet temperature variation Test 64661 showed a much slower calculated response of the precooler in the calculations than the test data. Further investigation revealed an error in calculating the heat exchanger tube mass for the PDC dynamic equations that resulted in a slower change in the tube wall temperature than measured. The transient calculations for both tests were done in two steps. The first step was done in the same fashion as the FY15 IST analysis, where the CR valve position and the turbine-compressor shaft speed were specified through the PDC input based on the test values. On the second step, the turbine-compressor shaft dynamics equations were invoked by specifying that the shaft is disconnected from the grid. In addition, the CR valve control was used to control the shaft speed, based on the turbine bypass control logic already implemented in the PDC. For the shaft power balance, the friction (windage) loss is calculated based on the shaft balance at the steady-state conditions and is assumed to be scaled to the third power of shaft speed in the transient. Both the steady-state and transient simulations of both tests showed good agreement with the test data. The only significant difference was the turbine performance, which was not predicted as well as it was in the previous IST simulation, resulting in the prediction of a somewhat different flow split between the two turbines. This flow split difference is believed to be the result of not addressing the recent turbine modifications in the model. In addition, the full simulation of the turbine-compressor speed variation Test 65261-P with shaft speed control showed greater a difference with the test data later in the transient than the other test. Further analysis of the results revealed that this difference is most likely due to scaling the shaft windage losses only with the shaft speed and ignoring its dependency on the fluid density in the shaft cavity. Based on the results of steady state and transient calculations of the Tests 64661 and 65216-P, several areas of future improvements for the PDC simulation of the IST are identified.

42 ENGINEERING↗

Failure Modes in Capacitors When Tested Under a Time-Varying Stress

Steady step surge testing (SSST) is widely applied to screen out potential power-on failures in solid tantalum capacitors. The test simulates the power supply's on and off characteristics. Power-on failure has been the prevalent failure mechanism for solid tantalum capacitors for decoupling applications. On the other hand, the SSST can also be reviewed as an electrically destructive test under a time-varying stress. It consists of rapidly charging the capacitor with incremental voltage increases, through a low resistance in series, until the capacitor under test is electrically shorted. Highly accelerated life testing (HALT) is usually a time-efficient method for determining the failure mechanism in capacitors; however, a destructive test under a time-varying stress like SSST is even more effective. It normally takes days to complete a HALT test, but it only takes minutes for a time-varying stress test to produce failures. The advantage of incorporating specific time-varying stress into a statistical model is significant in providing an alternative life test method for quickly revealing the failure modes in capacitors. In this paper, a time-varying stress has been incorporated into the Weibull model to characterize the failure modes. The SSST circuit and transient conditions to correctly test the capacitors is discussed. Finally, the SSST was applied for testing polymer aluminum capacitors (PA capacitors), Ta capacitors, and multi-layer ceramic capacitors with both precious metal electrode (PME) and base-metal-electrodes (BME). It appears that testing results are directly associated to the dielectric layer breakdown in PA and Ta capacitors and are independent on the capacitor values, the way the capacitors being built, and the manufactures. The testing results also reveal that ceramic capacitors exhibit breakdown voltages more than 20 times the rated voltage, and the breakdown voltages are inverse proportional to the dielectric layer thickness. The possibility of ceramic capacitors in front-end decoupling applications to block the surge noise from a power supply is also discussed.

Liu, David (Donhang)↗

Inverter Ground Fault Overvoltage Testing

This report describes testing conducted at NREL to determine the duration and magnitude of transient overvoltages created by several commercial PV inverters during ground fault conditions. For this work, a test plan developed by the Forum on Inverter Grid Integration Issues (FIGII) has been implemented in a custom test setup at NREL. Load rejection overvoltage test results were reported previously in a separate technical report.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Functional fiber-optic sensors embedded in stainless steel components using ultrasonic additive manufacturing for distributed temperature and strain measurements

The nuclear industry is progressing toward microreactors that can be factory assembled and deployed to remote regions for reliable, scalable power generation. However, the reduced power output requires enhanced monitoring capabilities to reduce staffing and eventually move toward autonomous control to improve the economics of microreactors. The ability to embed sensors such as fiber-optics, which can provide spatially distributed temperature and strain measurements, within microreactor components for real-time health monitoring would be particularly advantageous. Recent advances in ultrasonic additive manufacturing (UAM) have demonstrated the successful embedding of fiber-optics in soft materials such as Al and Cu by placing the sensors in machined cavities and ultrasonically welding over the top with thin foils. This article reports the first successful embedment of fiber-optic sensors and thermocouples within a common nuclear reactor material, SS304, via UAM. UAM parameters were first explored with simple plate geometries before moving to more complex geometries, such as pipes and other test articles for heat pipe–based microreactors. Select samples were sectioned for microscopy to evaluate the sensor/foil and foil/foil interfaces from samples fabricated by using 100% SS304 foils vs. foils plated with a Ni coating to improve UAM bonding. Furthermore, embedding metal-coated, low-bend loss fibers resulted in greatly reduced signal attenuation and adequate compressive residual strain in the embedded region to ensure successful strain coupling. Pipe specimen functional testing was performed by monitoring temperature and strain during transient and steady-state thermal testing.

36 MATERIALS SCIENCE↗