AEC-NASA Space Nuclear Propulsion Office instrumentation evaluation NRX-A2 tests
Performance evaluation for NRX-A2 reactor instrumentation kit
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Performance evaluation for NRX-A2 reactor instrumentation kit
Performance evaluation on spin and attitude control subsystem of small scientific satellite
Tests of metal erosion in operating engines show that addition of 5% tricresyl phosphate significantly reduces wear rate. Commercial 10W30 oil gives one tenth wear and degrades less with additive.
Tests on a high-speed single-cylinder engine are described. The regularity of the spark timing was varied by driving the timer from different engine shafts. A simple and reasonably accurate method of determining the spark timing is described. The results show that irregular spark timing may cause large errors in tests of the knocking properties of fuels. For the engine tested, it was found that a change of one crankshaft degree in spark restart was equivalent to an 0.85 inch Hg change in allowable inlet pressure.
My internship duties with Launch Control Systems required me to start performance testing of an Object Management Group's (OMG) Data Distribution Service (DDS) specification implementation by PrismTech Limited through the Java programming language application programming interface (API). DDS is a networking middleware for Real-Time Data Distribution. The performance testing involves latency, redundant publishers, extended duration, redundant failover, and read performance. Time constraints allowed only for a data throughput test. I have designed the testing applications to perform all performance tests when time is allowed. Performance evaluation data such as megabits per second and central processing unit (CPU) time consumption were not easily attainable through the Java programming language; they required new methods and classes created in the test applications. Evaluation of this product showed the rate that data can be sent across the network. Performance rates are better on Linux platforms than AIX and Sun platforms. Compared to previous C++ programming language API, the performance evaluation also shows the language differences for the implementation. The Java API of the DDS has a lower throughput performance than the C++ API.
The Orion Optical Navigation System, which is designed to perform the navigation which will allow the crew to return safely to Earth in the event of a permanent loss of communications with the ground, has been matured through analysis and testing. This paper will detail the extensive tests and analysis that have gone into fleshing out the performance of the system in the face of numerous constraints placed on the optical navigation system.
The Pacific Northwest National Laboratory (PNNL) located in Richland, Washington, hosted and administered Phase II Flaw Detection Performance Tests in August 2018 that allowed the newly matured ultrasonic guided wave phased-array (GWPA) air-slot NDE sensor—“Hanford-Probe A”—developed by Guidedwave to be evaluated for its flaw detection capability and repeatability. A portion of the Phase II Flaw Detection Performance Tests was performed on a subset of test flaws on which the original GWPA sensor was evaluated during Phase I Sensor Effectiveness Testing (SET) to facilitate a comparison in flaw detection performance between Hanford-Probe A and the original GWPA sensor demonstrated in Phase I. The objective of the performance comparison was to determine the extent to which GWPA sensor design changes impacted the flaw detection performance upon which selection of the sensor technology was originally based for the purpose of determining whether the flaw detection performance of the newly matured Hanford-Probe A GWPA air-slot NDE sensor is at least equal to that of the original GWPA sensor evaluated under Phase I SET. This technical letter report presents the results produced by the new Hanford-Probe A on the Phase I test flaws and the results of the flaw detection performance comparison between Hanford-Probe A and the original GWPA sensor demonstrated in Phase I.
This report summarizes work performed in setting up and performing tests on a regenerator test rig. An earlier status report presented test results, together with heat transfer correlations, for four regenerator samples (two woven screen samples and two felt metal samples). Lessons learned from this testing led to improvements to the experimental setup, mainly instrumentation as well as to the test procedure. Given funding and time constraints for this project it was decided to complete as much testing as possible while the rig was set up and operational, and to forego final data reduction and analysis until later. Additional testing was performed on several of the previously tested samples as well an on five newly fabricated samples. The following report is a summary of the work performed at OU, with many of the final test results included in raw data form.
The results of the Coastal Zone Color Scanner protoflight tests are examined in detail while some of the test results are evaluated with respect to expected performance. Performance characteristics examined include spectral response, signal to noise ratio as a function of radiance input, radiance response, the modulation transfer function, and the field of view and coregistration. The results of orbital sequence tests are also included. The in orbit performance or return of radiometric data in the six spectral bands is evaluated along with the data processing sequence necessary to derive the final data products. Examples of the raw data are given and the housekeeping or diagnostic data which provides information on the day to day health or status of the instrument are discussed.
A series of 5 cm by 5 cm bi-supported Solid Oxide Electrolysis Cells (SOEC) were produced by NASA for the Idaho National Laboratory (INL) and tested under the INL High Temperature Steam Electrolysis program. The results from the experimental demonstration of cell operation for both hydrogen production and operation as fuel cells is presented. An overview of the cell technology, test apparatus and performance analysis is also provided. The INL High Temperature Steam Electrolysis laboratory has developed significant test infrastructure in support of single cell and stack performance analyses. An overview of the single cell test apparatus is presented. The test data presented in this paper is representative of a first batch of NASA's prototypic 5 cm by 5 cm SOEC single cells. Clearly a significant relationship between the operational current density and cell degradation rate is evident. While the performance of these cells was lower than anticipated, in-house testing at NASA Glenn has yielded significantly higher performance and lower degradation rates with subsequent production batches of cells. Current post-test microstructure analyses of the cells tested at INL will be published in a future paper. Modification to cell compositions and cell reduction techniques will be altered in the next series of cells to be delivered to INL with the aim to decrease the cell degradation rate while allowing for higher operational current densities to be sustained. Results from the testing of new batches of single cells will be presented in a future paper.
Scrubbers required to reduce N2O4 contamination of nitrogen vent gas streams to a safe level to preclude health hazard to personnel and to preclude adverse environmental effects were developed. The scrubber principle involved is to absorb and neutralize the N2O4 component in a closed circuit circulating water/chemical solution in a vertical counter-flow, packed-tower configuration. The operational and performance test requirements for the scrubbers consist of demonstrating that the exit gas contamination level from the scrubbers does not exceed 150 ppm oxidizer under any flow conditions up to 400 scfm with inlet concentrations of up to 100,000 ppm oxidizer. Several problems were encountered during the performance testing that led to a series of investigations and supplementary testing. It was finally necessary to change the scrubber liquors in oxidizer scrubber to successfully achieve performance requirements. The scrubbers, the test configuration, and the various tests performed are described.
The James Webb Space Telescope (JWST) primary mirror (PM) is 6.6 meters in diameter and consists of 18 hexagonal segments, each 1.5 meters point-to-point. Each segment has a 6 degree-of-freedom hexapod actuation system and a radius-of-curvature (ROC) actuation system. The full telescope was tested at its cryogenic operating temperature at Johnson Space Center (JSC) in 2017. This testing included center-of-curvature measurements of the PM wavefront error using the Center-of-Curvature Optical Assembly (COCOA), along with the Absolute Distance Meter Assembly (ADMA). The COCOA included an interferometer, a reflective null, an interferometer-null calibration system, coarse and fine alignment systems, and two displacement measuring interferometer systems. A multiple-wavelength interferometer was used to enable alignment and phasing of the PM segments. By combining measurements at two laser wavelengths, synthetic wavelengths up to 15 millimeters could be achieved, allowing mirror segments with millimeter-level piston errors to be phased to the nanometer level. The ADMA was used to measure and set the spacing between the PM and the focus of the COCOA null (i.e., the PM center-of-curvature) for determination of the ROC. This paper describes the COCOA, the PM test setup, the testing performed, the test results, and the performance of the COCOA in aligning & phasing the PM segments and measuring the final PM wavefront error.
Implementing enhanced geothermal systems (EGS) will require improvements in understanding stimulation of crystalline rock to create appropriate flow pathways, and the ability to effectively simulate both the stimulation and the flow and transport processes in the resulting fracture network. The US Department of Energy (DOE) is addressing these and other challenges at multiple scales. The EGS Collab project, addressed here, is performing tests and modeling at the 10 m scale. The FORGE project is performing tests at the full reservoir scale. The EGS Collab team created an underground testbed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, at a depth of approximately 1.5 km to examine hydraulic fracturing (Experiment 1). We are currently building a second testbed at SURF at a depth of about 1.25 km aimed at investigating shear stimulation (Experiment 2). In Experiment 1, we drilled eight boreholes in a well-characterized phyllite and installed geophysical sensors in six of them to create a well-instrumented testbed to allow careful monitoring of stimulation events and flow tests. Numerical simulation was used to answer key experimental design questions, to forecast fracture propagation trajectories and extents, and to analyze and evaluate results both in near-real-time and in detailed process studies. Stimulations performed in this testbed allowed quantification of processes occurring during stimulation and the examination of dynamic flow occurrences. Long-term ambient temperature and chilled water flow tests were performed in addition to many tracer tests to examine system behavior. Our second testbed, targeted at shear stimulation, is currently being built at the SURF Facility at a depth of about 1.25 km in amphibolite under a different set of stress and fracture conditions than Experiment 1.
The development model test program was written to provide guidance for essential star tracker test support to the Space Shuttle Orbiter Program. The program organization included test equipment preparation, prototype baseline/acceptance tests, prototype total performance tests, and prototype special tests. Test configurations, preparation phase, documentation, scheduling, and manpower requirements are discussed. The test program permits an early evaluation of the tracker's performance prior to completion and testing of the final flight models.
The superconducting RF linac for Linac Coherent Light Source-II calls for 1.3 GHz 9-cell cavities with an average intrinsic quality factor Q{sub 0} of 2.7 × 10{sup 10} at 2.0 K and 16 MV/m accelerating gradient. Two niobium 9 cell cavities, prepared with nitrogen-doping at Fermilab, were assembled into the Cornell Horizontal Test Cryomodule (HTC) to test cavity performance in a cryomodule that is very similar to a full LCLS-II cryomodule. The cavities met LCLS-II specifications with an average quench field of 17 MV/m and an average Q{sub 0} of 3 × 10{sup 10}. The sensitivity of the cavities' residual resistance to ambient magnetic field was determined to be 0.5 nΩ/mG during fast cool down. In two cool downs, a heater attached to one of the cavity beam tubes was used to induce large horizontal temperature gradients. Here, we report on the results of these first tests of nitrogen-doped cavities in a cryomodule, which provide critical information for the LCLS-II project.
NASA is developing the X-38 vehicle that will demonstrate the technologies required for a potential crew return vehicle for the International Space Station. This vehicle would serve both as an ambulance for medical emergencies and as an evacuation vehicle for the space station. Control surfaces on the X-38 (body flaps and rudder/fin assemblies) require high temperature seals to limit hot gas ingestion and the transfer of heat to underlying low temperature structures. Working with the NASA Johnson Space Center, the Seals Team at the NASA Glenn Research Center completed a series of tests to further characterize baseline seal designs for the rudder/fin interfaces of the X-38. The structures of the rudder/fin assembly and its associated seals are shown in the the preceding illustration. Tests performed at Glenn indicated that exposure of the seals in a compressed state at simulated seal re-entry temperatures resulted in a large permanent set and loss of seal resiliency. This could be of concern because the seals are required to maintain contact with the sealing surfaces while the vehicle goes through the maximum re-entry heating cycle to prevent hot gases from leaking past the seals and damaging interior low-temperature structures. To simulate conditions in which the seals may become unloaded during use, such as when they take on a large permanent set, Glenn researchers performed room temperature flow and compression tests to determine seal flow rates, resiliency, and unit loads under minimal loads. Flow rates through an unloaded (i.e., 0-percent compression) double seal arrangement were twice those of a double seal compressed to the 20-percent design compression level. These flow rates are being used in thermal analyses to predict the effect of flow through the seals on over-all seal temperatures. Compression test results showed that seal unit loads and contact pressures were below the limits that Johnson had set as goals for the seals. In the rudder/fin seal location, the seals are in contact with shuttle thermal tiles and are moved across the tiles as the rudder is rotated during re-entry. Low seal unit loads and contact pressures are required to limit the loads on these tiles and minimize any damage that the seals could cause. A series of tests were performed on these seals in NASA Ames Research Center's arc jet facility. The arc jet facility approximates relevant thermal environments that a seal or other structure would be subjected to during extreme heating conditions such as those experienced during space vehicle re-entry. Eleven tests were completed, including one test in which no seal was installed in the gap to examine the flow of heat down into the gap. The seal was compressed between stationary insulation tiles and a movable elevon that was rotated during the test to deflect the arc jet exhaust into the seal gap. Peak seal temperatures as high as 2000 F were reached during the 5-min tests. Results of these tests indicate satisfactory performance of the seal for single-use (e.g., X-38) applications. The results of these tests were shared with the NASA Johnson Space Center and are being used to validate aerothermostructural analysis codes that predict seal temperatures under these conditions. The tests performed at Glenn have provided valuable information to Johnson about the performance of the seals that they are considering using in the rudder/fin location of the X-38 vehicle. Glenn and Johnson are currently defining what additional work needs to be done to develop the final rudder/fin seal design for the X-38 vehicle.
The primary objective of this project is to measure and model the performance of optical fibers in intense radiation fields when subjected to very high temperatures. This research will pave the way for fiber optic and optically based sensors under conditions expected in future high-temperature gas-cooled reactors. Sensor life and signal-to-noise ratios are susceptible to attenuation of the light signal due to scattering and absorbance in the fibers. This project will provide an experimental and theoretical study of the darkening of optical fibers in high-radiation and high-temperature environments. Although optical fibers have been studied for moderate radiation fluence and flux levels, the results of irradiation at very high temperatures have not been published for extended in-core exposures. Several previous multi-scale modeling efforts have studied irradiation effects on the mechanical properties of materials. However, model-based prediction of irradiation-induced changes in silica's optical transport properties has only recently started to receive attention due to possible applications as optical transmission components in fusion reactors. Nearly all damage-modeling studies have been performed in the molecular-dynamics domain, limited to very short times and small systems. Extended-time modeling, however, is crucial to predicting the long-term effects of irradiation at high temperatures, since the experimental testing may not encompass the displacement rate that the fibers will encounter if they are deployed in the VHTR. The project team will pursue such extended-time modeling, including the effects of the ambient and recrystallization. The process will be based on kinetic MC modeling using the concept of amorphous material consisting of building blocks of defect-pairs or clusters, which has been successfully applied to kinetic modeling in amorphized and recrystallized silicon. Using this procedure, the team will model compensation for rate effects, and the interplay of rate effects with the effects of annealing, to accurately predict the fibers' reliability and expected lifetime
The separation tests performed during the qualification test program of the Ariane 4 Payload Fairing are described. This is the first fairing structure to be developed using carbon fiber technology. Two separation tests were performed under vacuum conditions. The primary objectives of these tests were to verify compliance with the vehicle imposed requirements and to establish the behavioral characteristics of the fairing structure itself.