Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tank testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Study of Hydrogen Fuel Cell Technology for Freight Rail Propulsion and Review of Relevant Industry Standards.

Alternatives to conventional diesel electric propulsion are currently of interest to rail operators. In the U.S., smaller railroads have implemented natural gas and other railroads are exploring hydrogen technology as a cleaner alternative to diesel. Diesel, battery, hydrogen fuel cell, or track electrification all have trade-offs for operations, economics, safety, and public acceptability. A framework to compare different technologies for specific applications is useful to optimize the desired results. Standards from the Association of American Railroads (AAR) and other industry best practices were reviewed for applicability with hydrogen fuel cell technology. Some technical gaps relate to the physical properties of hydrogen, such as embrittlement of metals, invisible flames, and low liquid temperatures. A reassessment of material selection, leak/flame detection, and thermal insulation methods is required. Hydrogen is less dense and diffuses more easily than natural gas, and liquid hydrogen is colder than liquefied natural gas. Different densities between natural gas and hydrogen require modifications to tank designs and flow rates. Leaked hydrogen will rise rather than pool on the ground like diesel, requiring a modification to the location of hydrogen tanks on rolling stock. Finally, the vibration and shock experienced in the rail environment is higher than light-duty vehicles and stationary applications for which current fuel cell technology has been developed, requiring a modification in tank design requirements and testing.

08 HYDROGEN↗

Filtration of Hanford Tank 241-AN-107 Supernatant at 16 °C

Approximately 9 liters of supernatant from Hanford waste tank 241-AN-107 was delivered by Washington River Protection Solutions to the Radiochemical Processing Laboratory (RPL) at Pacific Northwest National Laboratory. The thirty-six AN-107 sample bottles consisted of six sets of six samples, with each set pulled from a unique tank sampling level. Prior to testing, samples from each level were composited to provide nominally level-independent feed for dead end filtration and ion exchange testing. The composited 241-AN-107 supernatant was chilled to 16 °C for 1 week prior to testing. Filtration testing was then conducted using a backpulse dead-end filter (BDEF) system equipped with a feed vessel and a Mott inline filter Model 6610 (Media Grade 5) in the hot cells of the RPL. The purpose of this testing is to a) demonstrate dead-end filtration (DEF) of AN-107 feed at reduced temperature to obtain prototypic tank side cesium removal (TSCR) flux rates and identify issues that may impact filtration after dilution to 5.5M Na, and b) provide feed for a follow on ion exchange unit operation. The feed was filtered through the BDEF system at a targeted flux of 0.065 gpm/ft 2 . During filtration the differential pressure required to effect filtration at 0.065 gpm/ft 2 was slow to increase for most of the filtration campaign. After all the feed bottles had been pumped into the slurry reservoir, the bottoms of the bottles were added to the reservoir and transmembrane pressure (TMP) reached 2.0 psid (the TSCR action limit). The prototypic filter cleaning process was unable to effectively restore filter performance, and cleaning with oxalic acid was required before flow through the filter could be restored. This indicates that the Media Grade 5 filter may require an alternative cleaning protocol when processing AN-107 supernatant. After completing filtration of the AN-107 feed, the filter was cleaned. Solids concentrated from the backpulse solutions were composed of natrophosphate, Mn-Fe phases, and fluoro-natrophosphate that occurred as particle agglomerates. The individual particles were in some cases 100s of micrometers across which is consistent with prior observations from AN-107 supernate waste characterizations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wind tunnel investigation of a Centaur standard shroud compartment vent from Mach number of 0.70 to 1.96

An experimental investigation was conducted in the Lewis Research Center 8- by 6-foot supersonic wind tunnel to determine the vent discharge coefficient for the Centaur standard shroud/liquid hydrogen tank compartment vent. The test was conducted from Mach 0.70 to 1.96 with the vent mounted in a flat plate. Full scale simulated flight hardware, such as the vent, corrugations, aft field joint ring and ice bag clip was used. Air was discharged from a plenum chamber, located on the tunnel sidewall behind the plate, through five 6.35 cm diameter vent orifices into the free stream. Boundary layer thickeners, analytically predicted displacement thickness for the vehicle nominal flight trajectory could be simulated over the Mach number range. The highest vent discharge coefficient for any given Mach number and vent pressure ratio generally occurred at the maximum displacement thickness.

Johns, A. L.↗

Optical zero-differential pressure switch and its evaluation in a multiple pressure measuring system

The design of a clamped-diaphragm pressure switch is described in which diaphragm motion is detected by a simple fiber-optic displacement sensor. The switch was evaluated in a pressure measurement system where it detected the zero crossing of the differential pressure between a static test pressure and a tank pressure that was periodically ramped from near zero to fullscale gage pressure. With a ramping frequency of 1 hertz and a full-scale tank pressure of 69 N/sq cm gage (100 psig), the switch delay was as long as 2 milliseconds. Pressure measurement accuracies were 0.25 to 0.75 percent of full scale. Factors affecting switch performance are also discussed.

Powell, J. A.↗

Study of liquid slosh in the tracking and data relay satellite hydrazine tanks

An experimental study was conducted to provide data for evaluation of the parameters for an analytical mechanical model representation of liquid/interface dynamics in the TDRSS propellant tanks. Models were developed for two liquid-under ullage (forward tank) configurations and for one liquid-over-ullage (aft tank) configuration. However, additional test runs were conducted with liquids of different densities in both cases to allow separation of bladder stiffness and gravity effects under various simulated steady acceleration conditions. Both static and dynamic parameters are evaluated to provide a good prediction of observed results.

Kana, D. D.↗

The Harp probe - An in situ Bragg scattering sensor

A wave sensor, consisting of parallel, evenly spaced capacitance wires, whose output is the sum of the water surface deflections at the wires, has been built and tested in a wave tank. The probe output simulates Bragg scattering of electromagnetic waves from a water surface with waves; it can be used to simulate electromagnetic probing of the sea surface by radar. The study establishes that the wave probe, called the 'Harp' for short, will simulate Bragg scattering and that it can also be used to study nonlinear wave processes.

Mollo-Christensen, E.↗

Elastomer Compound Developed for High Wear Applications

The U.S. Army is currently spending 300 million dollars per year replacing rubber track pads. An experimental rubber compound has been developed which exhibits 2 to 3 times greater service life than standard production pad compounds. To improve the service life of the tank track pads various aspects of rubber chemistry were explored including polymer, curing and reinforcing systems. Compounds that exhibited superior physical properties based on laboratory data were then fabricated into tank pads and field tested. This paper will discuss the compounding studies, laboratory data and field testing that led to the high wear elastomer compound.

Crawford, D.↗

The wave suppressor used in the N.A.C.A. tank

So long a time was required for the disturbed water to become quiet after a model had been towed down the N.A.C.A. tank, that only 12 to 18 runs a day could be made. In order to shorten the time lost in waiting between runs, several different methods of suppressing the waves were tried. The most effective form of wave suppressor developed consists of wooden frames covered with fine copper screening and secured horizontally just beneath the surface of the water at the sides of the tank. With these suppressor placed every 50 feet along the length of the tank, 40 to 60 test runs a day can be made.

Truscott, Starr↗

Hydrodynamic and Aerodynamic Tests of a Family of Models of Seaplane Floats with Varying Angles of Dead Rise - N.A.C.A. Models 57-A, 57-B, and 57-C

Three models of V-bottom floats for twin-float seaplanes (N.A.C.A. models 57-A, 57-B, and 57-C) having angles of dead rise of 20 degrees, 25 degrees, and thirty degrees, respectively, were tested in the N.A.C.A. tank and in the N.A.C.A. 7- by 10-foot wind tunnel. Within the range investigated, the effect of angle of dead rise on water resistance was found to be negligible at speeds up to and including the hump speed, and water resistance was found to increase with angle of dead rise at planing speeds. The height of the spray at the hump speed decreased with increase in angle of dead rise and the aerodynamic drag increased with dead rise. Lengthening the forebody of model 57-B decreased the water resistance and the spray at speeds below the hump speed. Spray strips provided an effective means for the control of spray with the straight V sections used in the series but considerably increased the aerodynamic drag. Charts for the determination of the water resistance and the static properties of the model with 25 degrees dead rise and for the aerodynamic drag of all the models are included for use in design.

Parkinson, John B↗

Transportation of liquid fluorine

In tests of a portable tank specially designed and constructed under Air Force Contract AF 33(616)-2229, liquid fluorine was safely transported and stored. The investigation included 82 hours of transportation in a total storage time of 2570 hours.

Ordin, Paul M↗

The Effect of Spray Strips on the Take-off Performance of a Model of a Flying-Boat Hull

The effect on the take-off performance of a model of the hull of a typical flying boat, Navy PH-1, of fitting spray strips of four different widths, each at three different angles, was determined by model tests in the NACA Tank. Spray strips of widths up to 3 percent of the beam improve the general performance at speeds near the hump and reduce the spray thrown. A downward angle of 30 degrees to 45 degrees in the neighborhood of the step seems most favorable for the reduction of the spray. The spray strips have a large effect in reducing the trimming moments at speeds near the hump speed, but have little effect on them at high speeds.

Truscott, Starr↗

Designing Space Station

An overview of preparations for the construction of Space Station Freedom (SSF) is presented. The video includes footage of astronauts testing materials for erectable structures in space both in the Shuttle bay while in orbit and in a neutral buoyancy tank at McDonald Douglas' Underwater Test Facility. Also shown are footage of robot systems that will assist the astronauts in building SSF, a computer simulation of an Orbiting Maneuvering Vehicle, solar dynamic mirrors that will power SSF, and mockups of the living quarters of the SSF.

Source record↗

The Effect of Lower Surface Spoilers on the Transonic Trim Change of a Wind-Tunnel Model of a Fighter Airplane Having a Modified Delta Wing

In an attempt to find an aerodynamic means of counteracting the transonic trim change of a fighter airplane, lower surface spoilers were tested on a 0.055-scale wind-tunnel model. The Mach number range of the tests was 0.8 to 1.2 at Reynolds numbers of approximately 4 million. Although the spoilers produced a moderate decrease in the trim change at low altitudes, they also produced a large increase in drag. Pressure-distribution tests with external fuel tanks showed large pressure changes on the lower surface of the wing due to the tanks.

Robinson, Robert C.↗

Polymer Matrix Composite Material Oxygen Compatibility

Carbon fiber/polymer matrix composite materials look promising as a material to construct liquid oxygen (LOX) tanks. Based on mechanical impact tests the risk will be greater than aluminum, however, the risk can probably be managed to an acceptable level. Proper tank design and operation can minimize risk. A risk assessment (hazard analysis) will be used to determine the overall acceptability for using polymer matrix composite materials.

Owens, Tom↗

Analysis of a Circular Composite Disk Subjected to Edge Rotations and Hydrostatic Pressure

The structural analysis results for a graphite/epoxy quasi-isotropic circular plate subjected to a forced rotation at the boundary and pressure is presented. The analysis is to support a specialized material characterization test for composite cryogenic tanks. Finite element models were used to ensure panel integrity and determine the pressure necessary to achieve a predetermined equal biaxial strain value. The displacement results due to the forced rotation at the boundary led to a detailed study of the bending stiffness matrix [D]. The variation of the bending stiffness terms as a function of angular position is presented graphically, as well as, an illustrative technique of considering the laminate as an I-beam.

Oliver, Stanley T.↗