Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TANK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

In-tank recirculating arsenic treatment system

A low-cost, water treatment system and method for reducing arsenic contamination in small community water storage tanks. Arsenic is removed by using a submersible pump, sitting at the bottom of the tank, which continuously recirculates (at a low flow rate) arsenic-contaminated water through an attached and enclosed filter bed containing arsenic-sorbing media. The pump and treatment column can be either placed inside the tank (In-Tank) by manually-lowering through an access hole, or attached to the outside of the tank (Out-of-Tank), for easy replacement of the sorption media.

42 ENGINEERING↗

Cesium Removal from AP-105 Hanford Tank Waste Using Spherical Resorcinol Formaldehyde Resin

Spherical resorcinol formaldehyde (SRF) resin is planned to be used to remove cesium (137Cs) from the aqueous phases of Hanford tank wastes in preparation for their vitrification at the Waste Treatment and Immobilization Plant. SRF is an elutable organic ion exchanger that is projected to be used in up to 30multiple process cycles (load/elute/regeneration) before being disposal . Only two full process cycles have been tested using SRF on Hanford tank waste. This paper describes the test results of six complete load/elute cycles using the SRF in a lead/lag column format with 12 liters of Hanford tank waste supernatant collected from Tank AP-105. The testing exposed the SRF to the combined sources of degradation: chemical attack from dissolved oxygen, nitric acid, and tank waste components; physical stress from resin expansion and contraction; and beta and gamma radiolytic exposure. Process conditions, dictated by Washington River Protection Solutions, featured loading until the lag column effluent reached 10% of the waste acceptance criteria (a Cs decontamination factor of 6,000). Under these conditions the lead column was nearly fully loaded and the lag column was loaded with about 20% of the input Cs. Variations in process flowrates and elution volumes were investigated as part of the testing. Characteristics examined included degradation with cycling, mass transfer zones as a function of flowrate, Cs leakage into the ensuing process cycle, and analyte mass fractionation.

spherical resorcincol formaldehyde, ion exchange, ↗

Ostwald Ripening and Its Effect on PuO2 Particle Size in Hanford Tank Waste

Between 1944 and 1989, the Hanford Site produced 60 percent (54.5 metric tons) of the United States weapons plutonium and produced an additional 12.9 metric tons of fuels-grade plutonium. High activity wastes, including plutonium lost from the separations processes used to isolate the plutonium, were discharged to underground storage tanks during these operations. Plutonium in the Hanford tank farms is estimated to be {approx}700 kg but may be up to {approx}1000 kg. Despite these apparent large quantities, the average plutonium concentration in the {approx}200 million liter tank waste volume is only about 0.003 grams per liter ({approx}0.0002 wt%). The plutonium is largely associated with low solubility metal hydroxide/oxide sludges where its low concentration and intimate mixture with neutron-absorbing elements (e.g., iron) are credited in nuclear criticality safety. However, concerns have been expressed that plutonium, in the form of plutonium hydrous oxide, PuO{sub 2} {center_dot} xH{sub 2}O, could undergo sufficient crystal growth through Ostwald ripening in the alkaline tank waste to potentially be separable from neutron absorbing constituents by settling or sedimentation. It was found that plutonium that entered the alkaline tank waste by precipitation through neutralization from acid solution is initially present as 2- to 3-nm (0.002- to 0.003-{mu}m) scale PuO{sub 2} {center_dot} xH{sub 2}O crystallite particles and grows from that point at exceedingly slow rates, posing no risk to physical segregation. These conclusions are reached by both general considerations of Ostwald ripening and specific observations of the behaviors of PuO{sub 2} and PuO{sub 2} {center_dot} xH{sub 2}O upon aging in alkaline solution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Literature Review on the Sorption of Plutonium, Uranium, Neptunium, Americium and Technetium to Corrosion Products on Waste Tank Liners

The Savannah River Site (SRS) has conducted performance assessment (PA) calculations to determine the risk associated with closing liquid waste tanks. The PA estimates the risk associated with a number of scenarios, making various assumptions. Throughout all of these scenarios, it is assumed that the carbon-steel tank liners holding the liquid waste do not sorb the radionuclides. Tank liners have been shown to form corrosion products, such as Fe-oxyhydroxides (Wiersma and Subramanian 2002). Many corrosion products, including Fe-oxyhydroxides, at the high pH values of tank effluent, take on a very strong negative charge. Given that many radionuclides may have net positive charges, either as free ions or complexed species, it is expected that many radionuclides will sorb to corrosion products associated with tank liners.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulant Development for Hanford Double-Shell Tank Mixing and Waste Feed Delivery Testing

The U.S. Department of Energy Office of River Projection manages the River Protection Project, which has the mission to retrieve and treat the Hanford tank waste for disposal and close the tank farms (Certa et al. 2011). Washington River Protection Solutions, LLC (WRPS) is responsible for a primary objective of this mission which is to retrieve and transfer tank waste to the Hanford Waste Treatment and Immobilization Plant (WTP). A mixing and sampling program with four separate demonstrations is currently being conducted to support this objective and also to support activities in a plan for addressing safety concerns identified by the Defense Nuclear Facilities Safety Board related to the ability of the WTP to mix, sample, and transfer fast settling particles. Previous studies have documented the objectives, criteria, and selection of non-radioactive simulants for these four demonstrations. The identified simulants include Newtonian suspending liquids with densities and viscosities that span the range expected in waste feed tanks. The identified simulants also include non-Newtonian slurries with Bingham yield stress values that span a range that is expected to bound the Bingham yield stress in the feed delivery tanks. The previous studies identified candidate materials for the Newtonian and non-Newtonian suspending fluids, but did not provide specific recipes for obtaining the target properties and information was not available to evaluate the compatibility of the fluids and particles or the potential for salt precipitation at lower temperatures. The purpose of this study is to prepare small batches of simulants in advance of the demonstrations to determine specific simulant recipes, to evaluate the compatibility of the liquids and particles, and to determine if the simulants are stable for the potential range of test temperatures. The objective of the testing, which is focused primarily on the Newtonian and non-Newtonian fluids, is to determine the composition of simulant materials that give the desired density and viscosity or rheological parameters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Double-Shell Tank Inspection Annual Report - Calendar Year 2012

The double-shell tanks (DSTs) were constructed between 1968 and 1986. They will have exceeded their design life before the waste can be removed and transferred to the Waste Treatment and Immobilization Plant for vitrification. The Double-Shell Tank Integrity Project has been established to evaluate tank aging, and ensure that each tank is structurally sound for continued use. This is the first issue of the Double-Shell Tank Inspection Annual Report. The purpose of this issue is to summarize the results of DST inspections conducted from the beginning of the inspection program through the end of CY2012. Hereafter, the report will be updated annually with summaries of the past year's DST inspection activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Contaminant Leach Testing of Hanford Tank 241-C-104 Residual Waste

Leach testing of Tank C-104 residual waste was completed using batch and column experiments. Tank C-104 residual waste contains exceptionally high concentrations of uranium (i.e., as high as 115 mg/g or 11.5 wt.%). This study was conducted to provide data to develop contaminant release models for Tank C-104 residual waste and Tank C-104 residual waste that has been treated with lime to transform uranium in the waste to a highly insoluble calcium uranate (CaUO4) or similar phase. Three column leaching cases were investigated. In the first case, C-104 residual waste was leached with deionized water. In the second case, crushed grout was added to the column so that deionized water contacted the grout prior to contacting the waste. In the third case, lime was mixed in with the grout. Results of the column experiments demonstrate that addition of lime dramatically reduces the leachability of uranium from Tank C-104 residual waste. Initial indications suggest that CaUO4 or a similar highly insoluble calcium rich uranium phase forms as a result of the lime addition. Additional work is needed to definitively identify the uranium phases that occur in the as received waste and the waste after the lime treatment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of thermolytic hydrogen generation rate of tank farm simulated and actual waste

To support resolution of Potential Inadequacies in the Safety Analysis for the Savannah River Site (SRS) Tank Farm, Savannah River National Laboratory conducted research to determine the thermolytic hydrogen generation rate (HGR) with simulated and actual waste. Gas chromatography methods were developed and used with air-purged flow systems to quantify hydrogen generation from heated simulated and actual waste at rates applicable to the Tank Farm Documented Safety Analysis (DSA). Initial simulant tests with a simple salt solution plus sodium glycolate demonstrated the behavior of the test apparatus by replicating known HGR kinetics. Additional simulant tests with the simple salt solution excluding organics apart from contaminants provided measurement of the detection and quantification limits for the apparatus with respect to hydrogen generation. Testing included a measurement of HGR on actual SRS tank waste from Tank 38. A final series of measurements examined HGR for a simulant with the most common SRS Tank Farm organics at temperatures up to 140 °C. The following conclusions result from this testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Removing Phosphate from Hanford High-Phosphate Tank Wastes: FY 2010 Results

The U.S. Department of Energy (DOE) is responsible for environmental remediation at the Hanford Site in Washington State, a former nuclear weapons production site. Retrieving, processing, immobilizing, and disposing of the 2.2 × 105 m3 of radioactive wastes stored in the Hanford underground storage tanks dominates the overall environmental remediation effort at Hanford. The cornerstone of the tank waste remediation effort is the Hanford Tank Waste Treatment and Immobilization Plant (WTP). As currently designed, the capability of the WTP to treat and immobilize the Hanford tank wastes in the expected lifetime of the plant is questionable. For this reason, DOE has been pursuing supplemental treatment options for selected wastes. If implemented, these supplemental treatments will route certain waste components to processing and disposition pathways outside of WTP and thus will accelerate the overall Hanford tank waste remediation mission.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Tank 241-S-112 Residual Waste Composition and Leach Test Data

This report presents the results of laboratory characterization and testing of two samples (designated 20406 and 20407) of residual waste collected from tank S-112 after final waste retrieval. These studies were completed to characterize the residual waste and assess the leachability of contami¬nants from the solids. This is the first report from this PNNL project to describe the composition and leach test data for residual waste from a salt cake tank. All previous PNNL reports (Cantrell et al. 2008; Deutsch et al. 2006, 2007a, 2007b, 2007c) describing contaminant release models, and characterization and testing results for residual waste in single-shell tanks were based on samples from sludge tanks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of the tank 6f final characterization samples-2012

The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to provide sample preparation and analysis of the Tank 6F final characterization samples to determine the residual tank inventory prior to grouting. Fourteen residual Tank 6F solid samples from three areas on the floor of the tank were collected and delivered to SRNL between May and August 2011.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Na Concentration on Cs Distribution with Crystalline Silicotitanate in Tank Waste Simulants

Crystalline silicotitanate (CST) ion exchange media is currently utilized in the tank side cesium removal (TSCR) system on the Hanford site to remove Cs-137 from the tank waste supernate. As the main dose contributor to the liquid supernate in Hanford tank waste, it is necessary to remove the Cs-137 to expedite low activity waste processing and immobilization. Ongoing batch contact experiments with CST have been done to tease out the impact of group II metals, anions, potassium, and temperature on Cs removal to better understand bounding conditions for operations as well as aid in development of a wholesome isotherm model to predict Cs behavior in the tank waste. This paper discusses the impact of Na concentration on Cs exchange and provides insight into the challenges associated with activity coefficient estimations for modeling Cs distribution in tank waste matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of public exposure resulted from the radioiodine delay tank facility of nuclear medicine department

The study is carried out to assess the exposure rate that could contribute to public exposure in a radioiodine ward delay tank facility of Radiotherapy, Oncology and Nuclear Medicine, Department, Hospital Universiti Sains Malaysia (HUSM). The exposure rate at several locations including the delay tank room, doorway and at the public walking route was measured using Victoreen 415P-RYR survey meter. The radioactive level of the {sup 131}I waste was measured using Captus 3000 well counting system. The results showed that exposure rate and total count of the delay tank sample increased when the radioiodine ward was fully occupied with patient and reduced when the ward was vacant. Occupancy of radioiodine ward for two consecutive weeks had dramatically increased the exposure rate around the delay tank and radioactive level of {sup 131}I waste. The highest exposure rate and radioactive level was recorded when the ward was occupied for two consecutive weeks with 177.00 µR/h and 58.36 kcpm respectively. The exposure rate decreased 15.76 % when the door of the delay tank room was closed. The exposure rate at public walking route decreased between 15.58 % and 36.92 % as the distance increased between 1 and 3 m.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cesium Ion Exchange Testing Using Crystalline Silicotitanate with Hanford Tank Waste 241-AP-107

Pacific Northwest National Laboratory has been tasked with demonstrating the unit operations for the Low Activity Waste Pretreatment System with actual Hanford tank waste. Crystalline silicotitanate (CST) ion exchange media is planned to be used to remove cesium (137Cs) from the aqueous phases of the tank wastes. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange), then vitrified. Removal of Cs from these wastes is an important processing step in preparing the waste for long-term safe storage. Bench-scale ion exchange testing with approximately 9 L of filtered AP-107 supernate was conducted using CST. Column testing was performed using prototypic LAWPS operations in a lead-lag column arrangement using 10-mL CST beds. Feed was processed until the lag column effluent reached the Hanford Tank Waste Treatment and Immobilization Plant waste acceptance criteria (WAC) for receiving supernatant waste for vitrification (a function of the Na and 137Cs concentrations), at which point, a new lag column was needed to continue processing and the original lag column was moved to the lead position. Greater than 99% of the Cs processed through the ion exchange system was collected on the CST in the columns. The AP-107 feed and column processing effluent underwent extensive characterization to better define waste characteristics and assess fractionation to the CST. Selected lead column samples were analyzed to assess particular metal analyte load characteristics. Results of these analyses will be discussed.

cesium exchange, Hanford tank waste, ion exchange↗

Rocking response of liquid-filled cylindrical tanks

The hydrodynamic response of liquid-filled storage tanks subjected to translational earthquake shaking has been the focus of studies for more than 75 years. In service, tanks experience six components of seismic input, with rocking due to support flexibility and/or rotational components of ground motion. Published theory for predicting hydrodynamic responses in rigid cylindrical tanks due to rotational seismic input is examined. Analytical solutions for pressure in the fluid and on the tank wall, and base moment are modified to account for the effects of angular displacements at the base. A finite element model of a water-filled cylindrical tank using the Arbitrary Lagrangian and Eulerian (ALE) solver in LS-DYNA is used to demonstrate the efficacy of the proposed expressions for three base rocking motions. Results from the modified analytical solutions and the finite element model are in excellent agreement.

58 GEOSCIENCES↗

PROBABILITY BASED CORROSION CONTROL FOR LIQUID WASTE TANKS - PART III

The liquid waste chemistry control program is designed to reduce the pitting corrosion occurrence on tank walls. The chemistry control program has been implemented, in part, by applying engineering judgment safety factors to experimental data. However, the simple application of a general safety factor can result in use of excessive corrosion inhibiting agents. The required use of excess corrosion inhibitors can be costly for tank maintenance, waste processing, and in future tank closure. It is proposed that a probability-based approach can be used to quantify the risk associated with the chemistry control program. This approach can lead to the application of tank-specific chemistry control programs reducing overall costs associated with overly conservative use of inhibitor. Furthermore, when using nitrite as an inhibitor, the current chemistry control program is based on a linear model of increased aggressive species requiring increased protective species. This linear model was primarily supported by experimental data obtained from dilute solutions with nitrate concentrations less than 0.6 M, but is used to produce the current chemistry control program up to 1.0 M nitrate. Therefore, in the nitrate space between 0.6 and 1.0 M, the current control limit is based on assumptions that the linear model developed from data in the <0.6 M region is applicable in the 0.6-1.0 M region. Due to this assumption, further investigation of the nitrate region of 0.6 M to 1.0 M has potential for significant inhibitor reduction, while maintaining the same level of corrosion risk associated with the current chemistry control program. Ongoing studies have been conducted in FY07, FY08, FY09 and FY10 to evaluate the corrosion controls at the SRS tank farm and to assess the minimum nitrite concentrations to inhibit pitting in ASTM A537 carbon steel below 1.0 molar nitrate. The experimentation from FY08 suggested a non-linear model known as the mixture/amount model could be used to predict the probability of corrosion in ASTM A537 in varying solutions as shown in Figure 1. The mixture/amount model takes into account not only the ratio (or mixture) of inhibitors and aggressive species, but also the total concentration (or amount) of species in a solution. Historically, the ratio was the only factor taken into consideration in the development of the current chemistry control program. During FY09, an experimental program was undertaken to refine the mixture/amount model by further investigating the risk associated with reducing the minimum molar nitrite concentration required to confidently inhibit pitting in dilute solutions. The results of FY09, as shown in Figure 2, quantified the probability for a corrosion free outcome for combinations of nitrate and nitrite. The FY09 data predict probabilities up to 70%. Additional experimental data are needed to increase the probability to an acceptable percentage.

36 MATERIALS SCIENCE↗

RESULTS FOR THE THIRD QUARTER 2010 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

This report details the chemical and radionuclide contaminant results for the characterization of the 2010 Third Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (i) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section. (ii) The reported detection limits for {sup 94}Nb, {sup 247}Cm and {sup 249}Cf are above the requested limits from Reference 4. However, they are below the limits established in Reference 3. (iii) The reported detection limit for {sup 242m}Am is greater than the requested limit from Attachment 8.4 of the WAC. (iv) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC. (v) The reported concentration of Isopropanol is greater than the limit from Table 4 of the WAC. (vi) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of the analytes in Tank 50.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

HANFORD TANK CLEANUP UPDATE

Access to Hanford's single-shell radioactive waste storage tank C-107 was significantly improved when workers completed the cut of a 55-inch diameter hole in the top of the tank. The core and its associated cutting equipment were removed from the tank and encased in a plastic sleeve to prevent any potential spread of contamination. The larger tank opening allows use of a new more efficient robotic arm to complete tank retrieval.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗