Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Software assurance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Random Vibrations

Ares I Zonal Random vibration environments due to acoustic impingement and combustion processes are develop for liftoff, ascent and reentry. Random Vibration test criteria for Ares I Upper Stage pyrotechnic components are developed by enveloping the applicable zonal environments where each component is located. Random vibration tests will be conducted to assure that these components will survive and function appropriately after exposure to the expected vibration environments. Methodology: Random Vibration test criteria for Ares I Upper Stage pyrotechnic components were desired that would envelope all the applicable environments where each component was located. Applicable Ares I Vehicle drawings and design information needed to be assessed to determine the location(s) for each component on the Ares I Upper Stage. Design and test criteria needed to be developed by plotting and enveloping the applicable environments using Microsoft Excel Spreadsheet Software and documenting them in a report Using Microsoft Word Processing Software. Conclusion: Random vibration liftoff, ascent, and green run design & test criteria for the Upper Stage Pyrotechnic Components were developed by using Microsoft Excel to envelope zonal environments applicable to each component. Results were transferred from Excel into a report using Microsoft Word. After the report is reviewed and edited by my mentor it will be submitted for publication as an attachment to a memorandum. Pyrotechnic component designers will extract criteria from my report for incorporation into the design and test specifications for components. Eventually the hardware will be tested to the environments I developed to assure that the components will survive and function appropriately after exposure to the expected vibration environments.

Messaro. Semma↗

IBEX: An open infrastructure software platform to facilitate collaborative work in radiomics

Purpose: Radiomics, which is the high-throughput extraction and analysis of quantitative image features, has been shown to have considerable potential to quantify the tumor phenotype. However, at present, a lack of software infrastructure has impeded the development of radiomics and its applications. Therefore, the authors developed the imaging biomarker explorer (IBEX), an open infrastructure software platform that flexibly supports common radiomics workflow tasks such as multimodality image data import and review, development of feature extraction algorithms, model validation, and consistent data sharing among multiple institutions. Methods: The IBEX software package was developed using the MATLAB and C/C++ programming languages. The software architecture deploys the modern model-view-controller, unit testing, and function handle programming concepts to isolate each quantitative imaging analysis task, to validate if their relevant data and algorithms are fit for use, and to plug in new modules. On one hand, IBEX is self-contained and ready to use: it has implemented common data importers, common image filters, and common feature extraction algorithms. On the other hand, IBEX provides an integrated development environment on top of MATLAB and C/C++, so users are not limited to its built-in functions. In the IBEX developer studio, users can plug in, debug, and test new algorithms, extending IBEX’s functionality. IBEX also supports quality assurance for data and feature algorithms: image data, regions of interest, and feature algorithm-related data can be reviewed, validated, and/or modified. More importantly, two key elements in collaborative workflows, the consistency of data sharing and the reproducibility of calculation result, are embedded in the IBEX workflow: image data, feature algorithms, and model validation including newly developed ones from different users can be easily and consistently shared so that results can be more easily reproduced between institutions. Results: Researchers with a variety of technical skill levels, including radiation oncologists, physicists, and computer scientists, have found the IBEX software to be intuitive, powerful, and easy to use. IBEX can be run at any computer with the windows operating system and 1GB RAM. The authors fully validated the implementation of all importers, preprocessing algorithms, and feature extraction algorithms. Windows version 1.0 beta of stand-alone IBEX and IBEX’s source code can be downloaded. Conclusions: The authors successfully implemented IBEX, an open infrastructure software platform that streamlines common radiomics workflow tasks. Its transparency, flexibility, and portability can greatly accelerate the pace of radiomics research and pave the way toward successful clinical translation.

60 APPLIED LIFE SCIENCES↗

CBP Toolbox Version 3.0 “Beta Testing” Performance Evaluation

One function of the Cementitious Barriers Partnership (CBP) is to assess available models of cement degradation and to assemble suitable models into a “Toolbox” that would be made available to members of the partnership, as well as the DOE Complex. To this end, SRNL and Vanderbilt University collaborated to develop an interface using the GoldSim software to the STADIUM @ code developed by SIMCO Technologies, Inc. and LeachXS/ORCHESTRA developed by Energy research Centre of the Netherlands (ECN). Release of Version 3.0 of the CBP Toolbox is planned in the near future. As a part of this release, an increased level of quality assurance for the partner codes and the GoldSim interface has been developed. This report documents results from evaluation testing of the ability of CBP Toolbox 3.0 to perform simulations of concrete degradation applicable to performance assessment of waste disposal facilities. Simulations of the behavior of Savannah River Saltstone Vault 2 and Vault 1/4 concrete subject to sulfate attack and carbonation over a 500- to 1000-year time period were run using a new and upgraded version of the STADIUM @ code and the version of LeachXS/ORCHESTRA released in Version 2.0 of the CBP Toolbox. Running both codes allowed comparison of results from two models which take very different approaches to simulating cement degradation. In addition, simulations of chloride attack on the two concretes were made using the STADIUM @ code. The evaluation sought to demonstrate that: 1) the codes are capable of running extended realistic simulations in a reasonable amount of time; 2) the codes produce “reasonable” results; the code developers have provided validation test results as part of their code QA documentation; and 3) the two codes produce results that are consistent with one another. Results of the evaluation testing showed that the three criteria listed above were met by the CBP partner codes. Therefore, it is concluded that the codes can be used to support performance assessment. This conclusion takes into account the QA documentation produced for the partner codes and for the CBP Toolbox.

97 MATHEMATICS AND COMPUTING↗

HDTS 2017.0 Testing and verification document

This report is a continuation of the series of Hunter Dose Tracking System (HDTS) Quality Assurance documents including (Foley and Powell, 2010; Dixon, 2012). In this report we have created a suite of automated test cases and a system to analyze the results of those tests as well as documented the methodology to ensure the field system performs within specifications. The software test cases cover all of the functions and interactions of functions that are practical to test. With the developed framework, if software defects are discovered, it will be easy to create one or more test cases to reproduce the defect and ensure that code changes correct the defect. These tests con rm HDTS version 2017.0 performs according to its specifications and documentation and that its performance meets the needs of its users at the Savannah River Site.

97 MATHEMATICS AND COMPUTING↗

Zero-Order Reaction Kinetics (Zero-RK): Enabling the Use of Detailed Chemical Kinetics in Combustion Simulations (CRADA Final Report)

This was a collaborative effort between Lawrence Livermore National Security, LLC (LLNS), as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Gamma Technologies, LLC (GT or Participante), to incorporate the ability to access LLNL chemical kinetics technologies while using GT-SUITE, GT’s market leading engine simulation software. At the end of the project, LLNL has released Zero-RK version 3.5 with zero- and one-dimensional (0-D and 1-D) solver functionality that interfaces with GT’s GT-SUITE v2023 and later releases. GT has tested its product to assure their customers that the interface can provide reduction in chemistry solution time for detailed chemistry simulations. The process has also positioned GT to easily benefit from future improvements of the Zero-RK suite of tools developed under the DOE Vehicle Technologies Office.

33 ADVANCED PROPULSION SYSTEMS↗

Zero Order Reactioin Kinetics: Enabling the use of Detailed Chemical Kinetics in Combustion Simulations (Final CRADA Report)

This was a collaborative effort between Lawrence Livermore National Security, LLC (LLNS), as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Gamma Technologies, LLC (GT or Participante), to incorporate the ability to access LLNL chemical kinetics technologies while using GT-SUITE, GT’s market leading engine simulation software. At the end of the project, LLNL has released Zero-RK version 3.5 with zero- and one-dimensional (0-D and 1-D) solver functionality that interfaces with GT’s GT-SUITE v2023 and later releases. GT has tested its product to assure their customers that the interface can provide reduction in chemistry solution time for detailed chemistry simulations. The process has also positioned GT to easily benefit from future improvements of the Zero-RK suite of tools developed under the DOE Vehicle Technologies Office.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Apollo Soyuz Test Project Weights and Mass Properties Operational Management System

The Apollo Soyuz Test Project (ASTP) Weights and Mass Properties Operational Management System was established to assure a timely and authoritative method of acquiring, controlling, generating, and disseminating an official set of vehicle weights and mass properties data. This paper provides an overview of the system and its interaction with the various aspects of vehicle and component design, mission planning, hardware and software simulations and verification, and real-time mission support activities. The effect of vehicle configuration, design maturity, and consumables updates is discussed in the context of weight control.

Collins, M. A., Jr.↗

IR Spot Weld Inspect

In automotive industry, destructive inspection of spot welds is still the mandatory quality assurance method due to the lack of efficient non-destructive evaluation (NDE) tools. However, it is costly and time-consuming. Recently at ORNL, a new NDE prototype system for spot weld inspection using infrared (IR) thermography has been developed to address this problem. This software contains all the key functions that ensure the NDE system to work properly: system input/output control, image acquisition, data analysis, weld quality database generation and weld quality prediction, etc.

Chen, Jian↗

Evaluation of a new IR-guided system for mechanical QA of linear accelerators

The authors report the development of a new procedure for mechanical quality assurance of linear accelerators using an infrared-guided system. The system consists of an infrared (IR) camera and an IR-reflective marker that can be attached to a gantry, a collimator, or a treatment table. The trace of this marker can be obtained in three dimensions (3D) for a full or partial rotation of the mechanical devices. The software is written to localize rotational axes of the gantry, collimator, and the treatment table based on the marker traces. The separation of these axes characterizes the size of the sphere defining the mechanical isocenter. Additional information on anomalies in gantry movement such as degree of gantry sag and hysteresis can also be obtained. An intrinsic uncertainty of the system to localize rotational axis is 0.35 mm or less. Tests on a linear accelerator demonstrated the ability of this system to detect the separation between rotational axes of less than 1 mm and to confirm orthogonality of the planes of gantry, collimator, and table rotation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accuracy Enhancement of Nuclear Power Plant Simulators Utilizing High Accuracy Simulation Predictions

More recently, reactor core simulators for core designs associated with commercial nuclear power plants that utilize what is believed to be higher fidelity models have been developed. Features such as neutronics models that utilize transport equation solvers with fine spatial meshes and many energy-groups, thermal-hydraulic models that utilize sub-channel solvers with fine spatial mesh and capable of treating a wide range of fluid conditions, and fuel-coolant chemistry interaction models capable of treating CRUD deposition are to be found in these higher fidelity core simulators. These reactor core simulators require access to higher performance computers, characterized by many processors, cores and large memory. So associated with utilization of these simulators is access to high performance computers and ability to accommodate in one’s workflow longer execution times. By contrast, currently used core simulators by the nuclear industry can execute on engineering workstations and have execution times of seconds to minutes. The desirability for having short execution times is not only desired for support of time critical tasks but supports the mental process of decision making by engineers. The goal of the work reported upon here has the objective of retaining the fidelity of higher fidelity models while retaining the ability to utilize engineering workstations. Beyond the core simulator goal, additional goals of this work include incorporating the just described core simulator capability into a Nuclear Steam Supply System (NSSS) simulator, and to incorporate the resulting capability into an environment supportive of design and operational decision making associated with nuclear power stations. The model selected for the core neutronics model is the NESTLE code, for the core thermal-hydraulic model is the CTF code utilizing coarse mesh, and for the NSSS model is the RELAP5-3D code. WSC’s proprietary 3KEYMASTERTM platform is being used to provide software coupling, user interface, visualization, and reporting. The NESTLE core neutronics simulator was first integrated with the CTF core thermal-hydraulic simulator using CTF developed communication commands which are also used for CTF to communicate with RELAP5-3D under WSC’s proprietary 3KEYMASTERTM platform. To assure NESTLE prediction consistency with higher fidelity core neutronic simulators, buffer codes have been created to automatically generate from output files written by the VERA core simulator the NESTLE nodal neutronic parameter’ library, geometry, and pin-power reconstruction input files, thereby avoiding a number of challenges associated with utilizing lattice physics codes and providing consistency with VERA predictions. To treat absorber rod effects a multi-set library is utilized, where a set refers to a specific absorber rod fully inserted pattern. A coarse spatial mesh CTF model was developed with features added that support using CTF as envisioned in the engineering quality simulator. A hybrid meshing approach was implemented to allow for automated construction of models with mixed levels of refinement. Specifically, a core model could resolve some assemblies at a nodal level (4 subchannels per assembly) and others at a pin-resolution (one subchannel per coolant subchannel in the assembly). The intention is that this will allow for better resolution of limiting conditions such as DNBR and PCT, which are based on local rod and subchannel conditions. Further development was done of features that enhance the capabilities for the envisioned engineering quality simulator that has been developed, but now for RELAP-3D. The RELAP5-3D code development includes ability to model more than 999 components and the addition of the cross-channels turbulence mixing model and the void drift model that are implemented in CTF, aiming to achieve closer prediction agreement of the two codes for transient simulations, specifically, more accurate matches of the overall mass, momentum, and energy exchanges of both the liquid and gas phases between the neighboring core assemblies. Graphics were also developed for the Instructor Station for this project under WSC’s proprietary 3KEYMASTERTM platform to facilitate design and operational decision making.

42 ENGINEERING↗

NASA's approach to flight confidence

NASA's confidence in the flight readiness of aerospace hardware and software is achieved by a thorough integration of safety activities into every program facet, from concept through the mission. This involves technical and administrative personnel, organizations that specify requirements, design, manufacturing, test and the operators. Reviews by inhouse and external specialists form an integral part of the assurance process. Examples of safety issues and their resolution for some power and propulsion functions are given (lithium cells, autoignition/fretting in high pressure oxygen environments, ignition sources from auxiliary power unit, and low thrust rocket engines). Finally, some comments on NASA's integrated safety activities and the Aerospace Safety Advisory Panel's role in the NASA review and assessment process all of which provides added confidence in achieving a high level of mission safety and success.

Roth, G. L.↗

TU-FG-BRB-12: Real-Time Visualization of Discrete Spot Scanning Proton Therapy Beam for Quality Assurance

Purpose: With the growing adoption of proton beam therapy there is an increasing need for effective and user-friendly tools for performing quality assurance (QA) measurements. The speed and versatility of spot-scanning proton beam (PB) therapy systems present unique challenges for traditional QA tools. To address these challenges a proof-of-concept system was developed to visualize, in real-time, the delivery of individual spots from a spot-scanning PB in order to perform QA measurements. Methods: The PB is directed toward a custom phantom with planar faces coated with a radioluminescent phosphor (Gd2O2s:Tb). As the proton beam passes through the phantom visible light is emitted from the coating and collected by a nearby CMOS camera. The images are processed to determine the locations at which the beam impinges on each face of the phantom. By so doing, the location of each beam can be determined relative to the phantom. The cameras are also used to capture images of the laser alignment system. The phantom contains x-ray fiducials so that it can be easily located with kV imagers. Using this data several quality assurance parameters can be evaluated. Results: The proof-of-concept system was able to visualize discrete PB spots with energies ranging from 70 MeV to 220 MeV. Images were obtained with integration times ranging from 20 to 0.019 milliseconds. If not limited by data transmission, this would correspond to a frame rate of 52,000 fps. Such frame rates enabled visualization of individual spots in real time. Spot locations were found to be highly correlated (R{sup 2}=0.99) with the nozzle-mounted spot position monitor indicating excellent spot positioning accuracy Conclusion: The system was shown to be capable of imaging individual spots for all clinical beam energies. Future development will focus on extending the image processing software to provide automated results for a variety of QA tests.

60 APPLIED LIFE SCIENCES↗

Underground Test Area Activity Quality Assurance Plan Nevada National Security Site, Nevada. Revision 2

This Quality Assurance Plan (QAP) provides the overall quality assurance (QA) requirements and general quality practices to be applied to the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) Underground Test Area (UGTA) activities. The requirements in this QAP are consistent with DOE Order 414.1D, Change 1, Quality Assurance (DOE, 2013a); U.S. Environmental Protection Agency (EPA) Guidance for Quality Assurance Project Plans for Modeling (EPA, 2002); and EPA Guidance on the Development, Evaluation, and Application of Environmental Models (EPA, 2009). If a participant’s requirement document differs from this QAP, the stricter requirement will take precedence. NNSA/NFO, or designee, must review this QAP every two years. Changes that do not affect the overall scope or requirements will not require an immediate QAP revision but will be incorporated into the next revision cycle after identification. Section 1.0 describes UGTA objectives, participant responsibilities, and administrative and management quality requirements (i.e., training, records, procurement). Section 1.0 also details data management and computer software requirements. Section 2.0 establishes the requirements to ensure newly collected data are valid, existing data uses are appropriate, and environmental-modeling methods are reliable. Section 3.0 provides feedback loops through assessments and reports to management. Section 4.0 provides the framework for corrective actions. Section 5.0 provides references for this document.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-407: Evaluation of Four Commercial Dosimetry Systems for Routine Patient-Specific Tomotherapy Delivery Quality Assurance

Purpose: The purpose of this project was to evaluate the performance of four commercially available dosimetry systems for Tomotherapy delivery quality assurance (DQA). Methods: Eight clinical patient plans were chosen to represent a range of treatment sites and typical clinical plans. Four DQA plans for each patient plan were created using the TomoTherapy DQA Station (Hi-Art version 4.2.1) on CT images of the ScandiDose Delta4, IBA MatriXX Evolution, PTW Octavius 4D and Sun Nuclear ArcCHECK phantoms. Each detector was calibrated following the manufacture-provided procedure. No angular response correction was applied. All DQA plans for each detector were delivered on the Tomotherapy Hi-Art unit in a single measurement session but on different days. The measured results were loaded into the vendor supplied software for each QA system for comparison with the TPS-calculated dose. The Gamma index was calculated using 3%/3mm, 2%/2mm with 10% dose threshold of maximum TPS calculated dose. Results: Four detector systems showed comparable gamma pass rates for 3%/3m, which is recommended by AAPM TG119 and commonly used within the radiotherapy community. The averaged pass rates ± standard deviation for all DQA plans were (98.35±1.97)% for ArcCHECK, (99.9%±0.87)% for Matrix, (98.5%±5.09)% for Octavius 4D, (98.7%±1.27)% for Delata4. The rank of the gamma pass rate for individual plans was consistent between detectors. Using 2%/2mm Gamma criteria for analysis, the Gamma pass rate decreased on average by 9%, 8%, 6.6% and 5% respectively. Profile and Gamma failure map analysis using the software tools from each dosimetry system indicated that decreased passing rate is mainly due to the threading effect of Tomo plan. Conclusion: Despite the variation in detector type and resolution, phantom geometry and software implementation, the four systems demonstrated similar dosimetric performance, with the rank of the gamma pass rate consistent for the plans considered.

60 APPLIED LIFE SCIENCES↗

Automating linear accelerator quality assurance

Purpose: The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. Methods: The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. Results: For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The standard deviation in MLC position, as determined by EPID measurements, across the consortium was 0.33 mm for IMRT fields. With respect to the log files, the deviations between expected and actual positions for parameters were small (<0.12 mm) for all Linacs. Considering both log files and EPID measurements, all parameters were well within published tolerance values. Variations in collimator angle, MLC position, and gantry sag were also evaluated for all Linacs. Conclusions: The performance of the TrueBeam Linac model was shown to be consistent based on automated analysis of trajectory log files and EPID images acquired during delivery of a standardized test suite. The results can be compared directly to tolerance thresholds. In addition, sharing of results from standard tests across institutions can facilitate the identification of QA process and Linac changes. These reference values are presented along with the standard deviation for common tests so that the test suite can be used by other centers to evaluate their Linac performance against those in this consortium.

60 APPLIED LIFE SCIENCES↗

Pulse Code Modulation (PCM) encoder handbook for Aydin Vector MMP-600 series system

The hardware and software characteristics of a time division multiplex system are described. The system is used to sample analog and digital data. The data is merged with synchronization information to produce a serial pulse coded modulation (PCM) bit stream. Information presented herein is required by users to design compatible interfaces and assure effective utilization of this encoder system. GSFC/Wallops Flight Facility has flown approximately 50 of these systems through 1984 on sounding rockets with no inflight failures. Aydin Vector manufactures all of the components for these systems.

Currier, S. F.↗

The Role of Independent V&V in Upstream Software Development Processes

This paper describes the role of Verification and Validation (V&V) during the requirements and high level design processes, and in particular the role of Independent V&V (IV&V). The job of IV&V during these phases is to ensure that the requirements are complete, consistent and valid, and to ensure that the high level design meets the requirements. This contrasts with the role of Quality Assurance (QA), which ensures that appropriate standards and process models are defined and applied. This paper describes the current state of practice for IV&V, concentrating on the process model used in NASA projects. We describe a case study, showing the processes by which problem reporting and tracking takes place, and how IV&V feeds into decision making by the development team. We then describe the problems faced in implementing IV&V. We conclude that despite a well defined process model, and tools to support it, IV&V is still beset by communication and coordination problems.

Easterbrook, Steve↗