Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensitivity Coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Parameterization-Induced Uncertainties and Impacts of Crop Management Harmonization in a Global Gridded Crop Model Ensemble

Global gridded crop models (GGCMs) combine agronomic or plant growth models with gridded spatial input data to estimate spatially explicit crop yields and agricultural externalities at the global scale. Differences in GGCM outputs arise from the use of different biophysical models, setups, and input data. GGCM ensembles are frequently employed to bracket uncertainties in impact studies without investigating the causes of divergence in outputs. This study explores differences in maize yield estimates from five GGCMs based on the public domain field-scale model Environmental Policy Integrated Climate (EPIC) that participate in the AgMIP Global Gridded Crop Model Intercomparison initiative. Albeit using the same crop model, the GGCMs differ in model version, input data, management assumptions, parameterization, and selection of subroutines affecting crop yield estimates via cultivar distributions, soil attributes, and hydrology among others. The analyses reveal inter-annual yield variability and absolute yield levels in the EPIC-based GGCMs to be highly sensitive to soil parameterization and crop management. All GGCMs show an intermediate performance in reproducing reported yields with a higher skill if a static soil profile is assumed or sufficient plant nutrients are supplied. An in-depth comparison of setup domains for two EPIC-based GGCMs shows that GGCM performance and plant stress responses depend substantially on soil parameters and soil process parameterization, i.e. hydrology and nutrient turnover, indicating that these often neglected domains deserve more scrutiny. For agricultural impact assessments, employing a GGCM ensemble with its widely varying assumptions in setups appears the best solution for coping with uncertainties from lack of comprehensive global data on crop management, cultivar distributions and coefficients for agro-environmental processes. However, the underlying assumptions require systematic specifications to cover representative agricultural systems and environmental conditions. Furthermore, the interlinkage of parameter sensitivity from various domains such as soil parameters, nutrient turnover coefficients, and cultivar specifications highlights that global sensitivity analyses and calibration need to be performed in an integrated manner to avoid bias resulting from disregarded core model domains. Finally, relating evaluations of the EPIC-based GGCMs to a wider ensemble based on individual core models shows that structural differences outweigh in general differences in configurations of GGCMs based on the same model, and that the ensemble mean gains higher skill from the inclusion of structurally different GGCMs. Although the members of the wider ensemble herein do not consider crop-soil-management interactions, their sensitivity to nutrient supply indicates that findings for the EPIC-based sub-ensemble will likely become relevant for other GGCMs with the progressing inclusion of such processes.

Folberth, Christian↗

Uncertain of uncertainties? A comparison of uncertainty quantification metrics for chemical data sets

Abstract With the increasingly more important role of machine learning (ML) models in chemical research, the need for putting a level of confidence to the model predictions naturally arises. Several methods for obtaining uncertainty estimates have been proposed in recent years but consensus on the evaluation of these have yet to be established and different studies on uncertainties generally uses different metrics to evaluate them. We compare three of the most popular validation metrics (Spearman’s rank correlation coefficient, the negative log likelihood (NLL) and the miscalibration area) to the error-based calibration introduced by Levi et al. ( Sensors 2022 , 22 , 5540). Importantly, metrics such as the negative log likelihood (NLL) and Spearman’s rank correlation coefficient bear little information in themselves. We therefore introduce reference values obtained through errors simulated directly from the uncertainty distribution. The different metrics target different properties and we show how to interpret them, but we generally find the best overall validation to be done based on the error-based calibration plot introduced by Levi et al. Finally, we illustrate the sensitivity of ranking-based methods (e.g. Spearman’s rank correlation coefficient) towards test set design by using the same toy model ferent test sets and obtaining vastly different metrics (0.05 vs. 0.65).

Rasmussen, Maria H.↗

A multi-prong approach towards the development of high performance Temperature sensor using MWCNTs/Al2O3 composite film

Highlights: • MWCNTs/Al{sub 2}O{sub 3} composite based self-standing highly sensitive temperature sensor. • Optimization of film thickness to achieve best performance of the device. • Effect of carrier drift under strong electron-phonon coupling is examined. • Non-contact measurements reveal possibilities of ambient environment monitoring. • Highly stable and reproducible response bidding commercial scale production. - Abstract: We report fabrication of high-performance temperature sensor from free-standing MWCNTs/Al{sub 2}O{sub 3} composite film where a multi-prong approach was undertaken to enhance sensor performance. Film thickness was varied until a threshold value was reached by playing surface-area to volume-ratio factor leading to enormous improvements in crucial sensor parameters–temperature coefficient of resistance (TCR) and thermal hysteresis. Increased TCR resulted in high sensitivity, ultrafast response and negligible hysteresis loss. Besides, effect of carrier-drift transport under strong electron-phonon scattering is investigated by permutation of channel-length and external DC bias. Observed TCR value is −0.96%/°C for 16.53 μm thick film, at 2 V applied-bias voltage for 1 mm channel-length. Moreover, the sensor exhibited negligible hysteresis loss along-with response and recovery times of ∼40 s and ∼185 s respectively. Non-contact mode temperature measurements also demonstrated excellent performance. Fabricated sensors exhibited good stability and negligible drift for six-months. These studies are significant towards fabricating simple, highly-sensitive, economic heat sensor with high reproducibility.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exploring the impacts of physics and resolution on aqua-planet simulations from a nonhydrostatic global variable-resolution modeling framework

Advances in computing resources are gradually moving regional and global numerical forecasting simulations towards sub-10 km resolution, but global high resolution climate simulations remain a challenge. The non-hydrostatic Model for Prediction Across Scales (MPAS) provides a global framework to achieve very high resolution using regional mesh refinement. Previous studies using the hydrostatic version of MPAS (H-MPAS) with the physics parameterizations of Community Atmosphere Model version 4 (CAM4) found notable resolution dependent behaviors. This study revisits the resolution sensitivity using the non-hydrostatic version of MPAS (NH-MPAS) with both CAM4 and CAM5 physics. A series of aqua-planet simulations at global quasi-uniform resolutions ranging from 240 km to 30 km and global variable resolution simulations with a regional mesh refinement of 30 km resolution over the tropics are analyzed, with a primary focus on the distinct characteristics of NH-MPAS in simulating precipitation, clouds, and large-scale circulation features compared to H-MPAS-CAM4. The resolution sensitivity of total precipitation and column integrated moisture in NH-MPAS is smaller than that in H-MPAS-CAM4. This contributes importantly to the reduced resolution sensitivity of large-scale circulation features such as the inter-tropical convergence zone and Hadley circulation in NH-MPAS compared to H-MPAS. In addition, NH-MPAS shows almost no resolution sensitivity in the simulated westerly jet, in contrast to the obvious poleward shift in H-MPAS with increasing resolution, which is partly explained by differences in the hyperdiffusion coefficients used in the two models that influence wave activity. With the reduced resolution sensitivity, simulations in the refined region of the NH-MPAS global variable resolution configuration exhibit zonally symmetric features that are more comparable to the quasi-uniform high-resolution simulations than those from H-MPAS that displays zonal asymmetry in simulations inside the refined region. Overall, NH-MPAS with CAM5 physics shows less resolution sensitivity compared to CAM4. These results provide a reference for future studies to further explore the use of NH-MPAS for high-resolution climate simulations in idealized and realistic configurations.

54 ENVIRONMENTAL SCIENCES↗

Sensitivity of the integrating pulse magnetometer with a first-order gradiometer

Inductive magnetometers used for measurements in pulsed magnetic fields should have proper frequency characteristics. In the present work we describe the construction of an inductive magnetometer for measurements of the magnetic moment in pulsed magnetic fields, together with the calculation procedures for determination of its sensitivity. We present a method for determination of the effective coefficient of the coupling between the coils set (gradiometer) and cylindrical samples, as well as a method for calculation of the thermal noise in the measuring system. The determination of the effective coupling coefficient permits a straightforward connection of the value of the measured signal with the magnetic moment of the sample and calibration of the gradiometer in absolute units. In the work we also present, as examples, some experimental hysteresis loops of pulse magnetization measurements for some ferromagnetic samples and a single crystal of high temperature superconductor. The results were obtained using our homemade pulse magnet and magnetometer with a gradiometer designed and constructed on basis of presented here calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beta systems error analysis

The atmospheric backscatter coefficient, beta, measured with an airborne CO Laser Doppler Velocimeter (LDV) system operating in a continuous wave, focussed model is discussed. The Single Particle Mode (SPM) algorithm, was developed from concept through analysis of an extensive amount of data obtained with the system on board a NASA aircraft. The SPM algorithm is intended to be employed in situations where one particle at a time appears in the sensitive volume of the LDV. In addition to giving the backscatter coefficient, the SPM algorithm also produces as intermediate results the aerosol density and the aerosol backscatter cross section distribution. A second method, which measures only the atmospheric backscatter coefficient, is called the Volume Mode (VM) and was simultaneously employed. The results of these two methods differed by slightly less than an order of magnitude. The measurement uncertainties or other errors in the results of the two methods are examined.

Source record↗

Sensitivity of selected geomagnetic properties to truncation level of spherical harmonic expansions

The model dependence of Gauss coefficients associated with a lack of spherical harmonic orthogonality on a nonuniform Magsat data grid is shown to be minor, where the fitting level exceeds the harmonic order by a value of approximately four. The shape of the magnetic energy spectrum outside the core, and the sensitivity to truncation level of magnetic contour location and the number of their intersections on the core-mantle boundary, suggest that spherical harmonic expansions of the main geomagnetic field should be truncated at a truncation level value of not more than eight if they are to be extrapolated to the core.

Benton, E. R.↗

Application of Temperature Sensitivities During Iterative Strain-Gage Balance Calibration Analysis

A new method is discussed that may be used to correct wind tunnel strain-gage balance load predictions for the influence of residual temperature effects at the location of the strain-gages. The method was designed for the iterative analysis technique that is used in the aerospace testing community to predict balance loads from strain-gage outputs during a wind tunnel test. The new method implicitly applies temperature corrections to the gage outputs during the load iteration process. Therefore, it can use uncorrected gage outputs directly as input for the load calculations. The new method is applied in several steps. First, balance calibration data is analyzed in the usual manner assuming that the balance temperature was kept constant during the calibration. Then, the temperature difference relative to the calibration temperature is introduced as a new independent variable for each strain--gage output. Therefore, sensors must exist near the strain--gages so that the required temperature differences can be measured during the wind tunnel test. In addition, the format of the regression coefficient matrix needs to be extended so that it can support the new independent variables. In the next step, the extended regression coefficient matrix of the original calibration data is modified by using the manufacturer specified temperature sensitivity of each strain--gage as the regression coefficient of the corresponding temperature difference variable. Finally, the modified regression coefficient matrix is converted to a data reduction matrix that the iterative analysis technique needs for the calculation of balance loads. Original calibration data and modified check load data of NASA's MC60D balance are used to illustrate the new method.

Ulbrich, N.↗

Highly efficient dye-sensitized solar cells based on HfO{sub 2} modified TiO{sub 2} electrodes

Graphical abstract: Display Omitted Highlights: ► HfO{sub 2} has been used to modify TiO{sub 2} electrodes in dye sensitized solar cells. ► HfO{sub 2} layer increases the dye adsorption. ► Diffusion coefficient (D{sub e}) and lifetime (τ{sub e}) of the photoelectrons were increased. ► Solar cell efficiency (η) was greatly improved from 5.67 to 9.59%. -- Abstract: In this article, we describe the use of hafnium oxide (HfO{sub 2}) as a new and efficient blocking layer material to modify TiO{sub 2} electrodes in dye sensitized solar cells. Different thicknesses of HfO{sub 2} over-layers were prepared by simple dip coating from two different precursors and their effects on the performance of DSSCs were studied. The HfO{sub 2} modification remarkably increases dye adsorption, resulting from the fact that the surface of HfO{sub 2} is more basic than that of TiO{sub 2}. Furthermore, the HfO{sub 2} coating demonstrated increased diffusion coefficient (D{sub e}) and lifetime (τ{sub e}) of the photoelectrons, indicating the improved retardation of the back electron transfer, which increases short-circuit current (J{sub sc}) and open-circuit voltage (V{sub oc}). Thereby, the photo conversion efficiency (η) of the solar cell was greatly improved from 5.67 to 9.59% (an improvement of 69.02%) as the HfO{sub 2} layer was coated over TiO{sub 2} films.

36 MATERIALS SCIENCE↗

Sensitivity of a Single Water Cerenkov Detector to Monitor Forbush Decreases

We describe a simple experimental setup to measure the rate of arrival of muons at the surface of the Earth by using a single water Cerenkov detector and home-made electronics. We find a strong anti-correlation between the muon rates averaged over one-hour periods and the atmospheric pressure, with a measured correlation coefficient of -0.67% per hPa. After applying this correction we achieve sufficient sensitivity to observe long term (hours) variations in the averaged muon rates which are greater than 2%. Forbush decreases as big as 4% have been observed with muon detectors located at similar magnetic rigidities compared to Morelia, therefore our experimental setup will detect Forbush decreases as soon as the Sun enters into a more active phase.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Saturated fluorescence measurements of the hydroxyl radical in laminar high-pressure flames

The efficacy of laser saturated fluorescence (LSF) for OH concentration measurements in high pressure flames was studied theoretically and experimentally. Using a numerical model describing the interaction of hydroxyl with nonuniform laser excitation, the effect of pressure on the validity of the balanced cross-rate model was studied along with the sensitivity of the depopulation of the laser-coupled levels to the ratio of rate coefficients describing: (1) electronic quenching to (sup 2) Sigma (+) (v double prime greater than 0), and (2) vibrational relaxation from v double prime greater than 0 to v double prime = 0. At sufficiently high pressures and near-saturated conditions, the total population of the laser-coupled levels reaches an asymptotic value, which is insensitive to the degree of saturation. When the ratio of electronic quenching to vibrational relaxation is small and the rate of coefficients for rotational transfer in the ground and excited electronic states are nearly the same, the balanced cross-rate model remains a good approximation for all pressures. When the above ratio is large, depopulation of the laser-coupled levels becomes significant at high pressures, and thus the balanced cross-rate model no longer holds. Under these conditions, however, knowledge of the depletion of the laser-coupled levels can be used to correct the model. A combustion facility for operation up to 20 atm was developed to allow LSF measurements of OH in high pressure flames. Using this facility, partial saturation in laminar high pressure (less than or equal to 12.3 atm) C2H6/O2/N2 flames was achieved. To evaluate the limits of the balanced cross-rate model, absorption and calibrated LSF measurements at 3.1 and 6.1 atm were compared. The fluorescence voltages were calibrated with absorption measurements in an atmospheric flame and corrected for their finite sensitivity to quenching with: (1) estimated quenching rate coefficients, and (2) an in situ measurement from a technique employing two fluorescence detection geometries.

Carter, Campbell D.↗

A Quantitative Study of Oxygen as a Metabolic Regulator

An acute reduction in oxygen (O2) delivery to a tissue is generally associated with a decrease in phosphocreatine, increases in ADP, NADH/NAD, and inorganic phosphate, increased rates of glycolysis and lactate production, and reduced rates of pyruvate and fatty acid oxidation. However, given the complexity of the human bioenergetic system and its components, it is difficult to determine quantitatively how cellular metabolic processes interact to maintain ATP homeostasis during stress (e.g., hypoxia, ischemia, and exercise). Of special interest is the determination of mechanisms relating tissue oxygenation to observed metabolic responses at the tissue, organ, and whole body levels and the quantification of how changes in tissue O2 availability affect the pathways of ATP synthesis and the metabolites that control these pathways. In this study, we extend a previously developed mathematical model of human bioenergetics to provide a physicochemical framework that permits quantitative understanding of O2 as a metabolic regulator. Specifically, the enhancement permits studying the effects of variations in tissue oxygenation and in parameters controlling the rate of cellular respiration on glycolysis, lactate production, and pyruvate oxidation. The whole body is described as a bioenergetic system consisting of metabolically distinct tissue/organ subsystems that exchange materials with the blood. In order to study the dynamic response of each subsystem to stimuli, we solve the ordinary differential equations describing the temporal evolution of metabolite levels, given the initial concentrations. The solver used in the present study is the packaged code LSODE, as implemented in the NASA Lewis kinetics and sensitivity analysis code, LSENS. A major advantage of LSENS is the efficient procedures supporting systematic sensitivity analysis, which provides the basic methods for studying parameter sensitivities (i.e., changes in model behavior due to parameter variation). Sensitivity analysis establishes relationships between model predictions and problem parameters (i.e., initial concentrations, rate coefficients, etc). It helps determine the effects of uncertainties or changes in these input parameters on the predictions, which ultimately are compared with experimental observations in order to validate the model. Sensitivity analysis can identify parameters that must be determined accurately because of their large effect on the model predictions and parameters that need not be known with great precision because they have little or no effect on the solution. This capability may prove to be important in optimizing the design of experiments, thereby reducing the use of animals. This approach can be applied to study the metabolic effects of reduced oxygen delivery to cardiac muscle due to local myocardial ischemia and the effects of acute hypoxia on brain metabolism. Other important applications of sensitivity analysis include identification of quantitatively relevant pathways and biochemical species within an overall mechanism, when examining the effects of a genetic anomaly or pathological state on energetic system components and whole system behavior.

Radhakrishnan, Krishnan↗

Calculating Control Rod Differential Worth Using Adjoint-Weighted Method

Recently, there are more and more research on using Monte Carlo method to calculate reactor important parameters. Control rod worth is one of the important parameters as it can determine the critical control rod position. There are two presentations of the control rod worth for utilization purpose, integral and differential. The former is the total reactivity change, while the latter is the reactivity change caused by per unit movement. In Monte Carlo calculation, differential control rod worth of a particular position is estimated by finite difference of reactivity between a small gap divided by gap distance. Though easy to implemented, the problem of this approach lies in that too large gap will enlarge error between 'differential' and 'difference', while too small gap will be disturbed by error caused by random fluctuation. Monte Carlo perturbation theory has been used to calculate the k{sub eff} sensitivity to certain parameters for a long time. By calculating the differential coefficient along with the k{sub eff}, this method is quite time-consuming and relatively accurate compared to finite difference method. Nevertheless, most of perturbation research focus on the perturbation of nuclide density or nuclear data. For geometrical perturbation, limited research was done before. Takahashi estimated the k{sub eff} sensitivity to reflector movement of pulsed fast reactor. MCNP6 used adjoint-weighted method for Godiva, Zeus and uranium oxyfluoride solution container benchmarks. This paper tries to apply the perturbation method to the determination of control rod differential worth. In this paper, based on RMC, a continuous-energy Reactor Monte Carlo transport code, Iterated Fission Probability method (IFP) is researched to calculate control rod differential worth on assembly level. IFP was originally developed by Hurwitz, and has been adopted by most of Monte Carlo code to compute adjoint-weighted parameters. This paper is organized with four parts. The first is introduction. Adjoint-weighted method is introduced in the second part. Problem 4 of benchmark from CASL is built to verify the method. Conclusion is given in final part.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Friction and wear behavior of single-crystal silicon carbide in contact with titanium

Sliding friction experiments were conducted with single crystal silicon carbide in sliding contact with titanium. Results indicate that the friction coefficient is greater in vacuum than in argon and that this is due to the greater adhesion or adhesive transfer in vacuum. Thin films of silicon carbide transferred to titanium also adhered to silicon carbide both in argon at atmospheric pressure and in high vacuum. Cohesive bonds fractured on both the silicon carbide and titanium surfaces. The wear debris of silicon carbide created by fracture plowed the silicon carbide surface in a plastic manner. The friction characteristics of titanium in contact with silicon carbide were sensitive to the surface roughness of silicon carbide, and the friction coefficients were higher for a rough surface of silicon carbide than for a smooth one. The difference in friction results was due to plastic deformation (plowing of titanium).

Miyoshi, K.↗

Nanowell-patterned TiO{sub 2} microcantilevers for calorimetric chemical sensing

A sensitive calorimetric sensor using a TiO{sub 2} microcantilever with nanowells patterned on one of its sides is described. This single material cantilever is sensitive to temperature change without relying on the metal deposition-based bimetallic effect. The thermomechanical sensitivity originates from the structure dependent variations in both the elastic modulus and thermal expansion coefficient due to the presence of ordered nanowells. These cantilever beams offer an alternate and efficient chemical sensing route for vapor phase analytes using photothermal spectroscopy. Selective and sensitive detection of organophosphorus compounds, as well as their photocatalytic decomposition under ultraviolet light exposure are demonstrated.

36 MATERIALS SCIENCE↗

Model biases in high-burnup fast reactor simulations

A new code system called the Advanced Reactor Modeling Interface (ARMI) has been developed that loosely couples multiscale, multiphysics nuclear reactor simulations to provide rapid, user-friendly, high-fidelity full systems analysis. Incorporating neutronic, thermal-hydraulic, safety/transient, fuel performance, core mechanical, and economic analyses, ARMI provides 'one-click' assessments of many multi-disciplined performance metrics and constraints that historically require iterations between many diverse experts. The capabilities of ARMI are implemented in this study to quantify neutronic biases of various modeling approximations typically made in fast reactor analysis at an equilibrium condition, after many repetitive shuffles. Sensitivities at equilibrium that result in very high discharge burnup are considered ( and >20% FIMA), as motivated by the development of the Traveling Wave Reactor. Model approximations discussed include homogenization, neutronic and depletion mesh resolution, thermal-hydraulic coupling, explicit control rod insertion, burnup-dependent cross sections, fission product model, burn chain truncation, and dynamic fuel performance. The sensitivities of these approximations on equilibrium discharge burnup, k{sub eff}, power density, delayed neutron fraction, and coolant temperature coefficient are discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity Analysis of an Experimental Breeder Reactor II Fuel Assembly

The Experimental Breeder Reactor II (EBR-II) was selected as a candidate for a reactor physics benchmark evaluation due to its unique features and capabilities. In connection with the benchmark evaluation, the goal of this work was to perform a sensitivity analysis. The EBR-II was a sodium cooled, pool type, metal fueled, fast spectrum reactor. EBR-II operated from 1964 through 1994. It had a maximum heat output of 62.5 MW which could produce 20 MW of electricity. The design of EBR-II consisted of 637 hexagonal shaped, removable assemblies. The assemblies were divided into three regions: the core, an inner blanket, and an outer blanket. The core region contained assemblies with 91 fuel rods in each. The fuel was enriched uranium metal and was clad within stainless steel. The core region also included two safety assemblies and eight control assemblies with the difference being that these assemblies only contained 61 fuel rods. Additional assemblies in the core region included stainless steel dummies, half worth drivers, and experimental/instrumentation assemblies. The inner blanket region initially consisted of depleted uranium for fuel breeding, but was replaced, after proving the concept of breeding, with stainless steel reflectors for the purpose of irradiation. The outer blanket region consisted of depleted uranium. Figure 1 shows a cross section view of the EBR-II core layout. Each assembly was approximately 234 cm long with the uranium fuel section being 33 cm long. Above and below the fuel were stainless steel neutron reflectors. Additionally, orifices at the bottom of the assembly allowed for sodium coolant to flow upward, with larger holes in the subassemblies at the center where the greatest heat was produced. The core of EBR-II was enclosed by a stainless steel reactor vessel which was comprised of a radial shell, a lower grid plenum structure, and an upper reactor vessel cover that served as a neutron shield. Surrounding the reactor vessel radially were layers of graphite and borated graphite shielding. The entire assembly is submerged 3 meters in a pool of sodium. The pool contained up to 337,000 liters of sodium which was forced through the core and blanket regions using two centrifugal pumps that were also submerged within the sodium pool. The design of EBR-II included many safety features. The compatibility between the sodium and stainless steel prevented corrosion and therefore the risk of a radioactive release due to corrosion. The sodium coolant was kept at near atmospheric pressure which made any leak more controllable. The metal fuel, cladding, and coolant allowed for heat to be removed easily. The large volume of sodium allowed for heat to be absorbed without problems occurring. Lastly, the reactor would expand as temperature increased which would result in greater neutron leakage. This extra leakage caused a large negative temperature reactivity feedback which automatically shut the reactor down in case of an accident. EBR-II had unique capabilities which were proven during the Integral Fast Reactor initiative. This program lasted from 1984 to 1994. The goal of this program was to solve many of the perceived problems with nuclear energy through scientific means. The safety features of EBR-II were put to the test in April 1986. The tests simulated loss of reactor coolant flow and loss of a heat sink. For both of these tests, the reactor was at 100% power and was not scrammed. During both tests, the reactor shut itself down and achieved a safe steady state temperature all due to the design of the reactor. It was because of these tests that EBR-II was chosen for a reactor physics benchmark evaluation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A data-independent acquisition-based global phosphoproteomics system enables deep profiling

Phosphoproteomics can provide insights into cellular signaling dynamics. To achieve deep and robust quantitative phosphoproteomics profiling for minute amounts of sample, we here develop a global phosphoproteomics strategy based on data-independent acquisition (DIA) mass spectrometry and hybrid spectral libraries derived from data-dependent acquisition (DDA) and DIA data. Benchmarking the method using 166 synthetic phosphopeptides shows high sensitivity (<0.1 ng), accurate site localization and reproducible quantification (~5% median coefficient of variation). As a proof-of-concept, we use lung cancer cell lines and patient-derived tissue to construct a hybrid phosphoproteome spectral library covering 159,524 phosphopeptides (88,107 phosphosites). Based on this library, our single-shot streamlined DIA workflow quantifies 36,350 phosphosites (19,755 class 1) in cell line samples within two hours. Application to drug-resistant cells and patient-derived lung cancer tissues delineates site-specific phosphorylation events associated with resistance and tumor progression, showing that our workflow enables the characterization of phosphorylation signaling with deep coverage, high sensitivity and low between-run missing values.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗