Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Estimation of regional heat flux from scanning radiometer measurements

The paper presents a statistical method for extracting regional information on the radiative heat flux at the top of the atmosphere from a satellite-borne scanning radiometer. The radiative heat flux distribution is denoted by a double Fourier series with coefficients to be determined from measurements. The method determines, in the sense of minimum variance, the best linear estimator of the total flux over a region. The heat flux distribution is represented by a truncated series which is unbiased.

Bess, T. D.↗

Effects of radiation upon the light-sensing elements of the retina as characterized by scanning electron microscopy

A model system using Necturus maculosus, the common mudpuppy, was established for evaluating effects of radiation upon the light-sensing elements of the retina. Accelerated heavy ions of helium and neon from the Berkeley Bevalac were used. A number of criteria were chosen to characterize radiation damage by observing morphological changes with the scanning electron microscope. The studies indicated retina sensitivity to high-LET (neon) particles at radiation levels below 10 rads (7 particles per visual element) whereas no significant effects were seen from fast helium ions below 50 rads.

Malachowski, M. J.↗

Airline pilot scanning behavior during approaches and landing in a Boeing 737 simulator

A series of approaches using airline-rated Boeing 737 pilots in an FAA qualified simulator has been conducted. The test matrices include both manual and coupled approaches for VFR, Category I and Category II conditions. A nonintrusive oculometer system was used to track the pilot's eye-point-of-regard throughout the approach. The results indicate that, in general, the pilots use a different scan technique for the manual and coupled (auto-pilot with manual throttle) conditions. For the manual approach 73 percent of the time was spent on the Flight Director and 13 percent on airspeed as opposed to 50 percent on Flight Director and 23 percent on airspeed for the coupled approaches. For the visual portion of approach from less than 100 m (300 ft) to touchdown or when the touchdown point came into view, the pilots tend to fixate on their aim or touchdown area until the flare initiation, at which time they let their eye-point-of-regard move up the runway to use the centerline lights for rollout guidance.

Spady, A. A., Jr.↗

Applications of pilot scanning behavior to integrated display research

The oculometer is an electrooptical device designed to measure pilot scanning behavior during instrument approaches and landing operations. An overview of some results from a simulation study is presented to illustrate how information from the oculometer installed in a visual motion simulator, combined with measures of performance and control input data, can provide insight into the behavior and tactics of individual pilots during instrument approaches. Differences in measured behavior of the pilot subjects are pointed out; these differences become apparent in the way the pilots distribute their visual attention, in the amount of control activity, and in selected performance measures. Some of these measured differences have diagnostic implications, suggesting the use of the oculometer along with performance measures as a pilot training tool.

Waller, M. C.↗

Self-scanned photodiode array - High performance operation in high dispersion astronomical spectrophotometry

A multichannel spectrophotometric detector system has been developed using a 1024 element self-scanned silicon photodiode array, which is now in routine operation with the high-dispersion coude spectrograph of the University of Texas McDonald Observatory 2.7-m telescope. Operational considerations in the use of such arrays for high precision and low light level spectrophotometry are discussed. A detailed description of the system is presented. Performance of the detector as measured in the laboratory and on astronomical program objects is described, and it is shown that these arrays are highly effective detectors for high dispersion astronomical spectroscopy.

Vogt, S. S.↗

Typhoon June /1975/ viewed by a scanning microwave spectrometer

Data were collected by the scanning microwave spectrometer onboard Nimbus 6 during the June 1975 typhoon in the Philippine Sea. The spectrometer was equipped with channels centered on 22.23 GHz (a water vapor band), 31.65 GHz (a transmittance window), and 52.85, 53.85, and 55.45 GHz (an oxygen band). Temperature maps, derived from oxygen band measurements, showed that the typhoon eye had a single peak varying in amplitude with time. Water line and window measurements were used to develop a coordinate system having mutually orthogonal atmospheric variables of column water-vapor content and cloud liquid-water content. Vapor measurements showed a maximum around the intensifying typhoon with a more developed structure during typhoon development. Values were extrapolated for surface wind speed and cloud liquid water vapor content by assuming the troposphere to be saturated with respect to the water vapor in the typhoon. Comparisons with infrared cloud imagery and aircraft flight data show different time variations, attributed to poor typhoon-eye resolution in the microwave images.

Rosenkranz, P. W.↗

Interpretation of scanning electron microscope measurements of minority carrier diffusion lengths in semiconductors

In scanning electron microscope (SEM) injection measurements of minority carrier diffusion lengths some uncertainties of interpretation exist when the response current is nonlinear with distance. This is significant in epitaxial layers where the layer thickness is not large in relation to the diffusion length, and where there are large surface recombination velocities on the incident and contact surfaces. An image method of analysis is presented for such specimens. A method of using the results to correct the observed response in a simple convenient way is presented. The technique is illustrated with reference to measurements in epitaxial layers of GaAs. Average beam penetration depth may also be estimated from the curve shape.

Flat, A.↗

New technique for single-scan T1 measurements using solid echoes

A simple technique for single-scan T1 measurements in solids is proposed and analyzed for single exponential spin-lattice relaxation. In this technique, the direct spin heating caused by the sampling process is significantly reduced in comparison with conventional techniques by utilizing the 'solid echo' to refocus the magnetization. The applicability of this technique to both the solid and liquid phases is demonstrated.

Burum, D. P.↗

Location of unidentified weak X-ray sources by the HEAO-1 scanning modulation collimator

Four weak sources for which precise positions have been obtained from the HEAO-1 Scanning Modulation Collimator (MC) experiment are discussed. One source (4U 0446+44) with the center of the cluster of galaxies containing 3C129 and 3C129.1 has been identified, and its angular size has been measured. One source with a galactic star is identified, although it is at galactic latitude b = 51 deg. The other two sources, 2A 0526-328 and 2A 0922-317, remain unidentified.

Schwartz, D. A.↗

Limited scan dual-band high-gain antenna

Dual band communication and tracking antenna concept combines S- and X-band high gain performance in near field cassagrainian configuration. Design incorporating subreflector in near field of feed permits limited electronic scanning with phased array feed of approximately subreflector size placed in region between subreflector and main reflector.

Cramer, P. W., Jr.↗

Improvement of CAT scanned images

Digital enhancement procedure improves definition of images. Tomogram is generated from large number of X-ray beams. Beams are collimated and small in diameter. Scanning device passes beams sequentially through human subject at many different angles. Battery of transducers opposite subject senses attenuated signals. Signals are transmitted to computer where they are used in construction of image on transverse plane through body.

Roberts, E., Jr.↗

Electronically scanned pressure sensor module with in SITU calibration capability

This high data rate pressure sensor module helps reduce energy consumption in wind tunnel facilities without loss of measurement accuracy. The sensor module allows for nearly a two order of magnitude increase in data rates over conventional electromechanically scanned pressure sampling techniques. The module consists of 16 solid state pressure sensor chips and signal multiplexing electronics integrally mounted to a four position pressure selector switch. One of the four positions of the pressure selector switch allows the in situ calibration of the 16 pressure sensors; the three other positions allow 48 channels (three sets of 16) pressure inputs to be measured by the sensors. The small size of the sensor module will allow mounting within many wind tunnel models, thus eliminating long tube lengths and their corresponding slow pressure response.

Gross, C.↗

Characterization of defect growth structure in ion plated films by scanning electron microscopy

Copper and gold films (0.2 to 2 microns) were ion plated onto polished 304-stainless-steel surfaces. These coatings were examined by scanning electron microscopy for coating growth defects. Three types of defects were distinguished: nodular growth, abnormal or runaway growth, and spits. The cause and origin for each type of defect was traced. Nodular growth is primarily due to inherent substrate microdefects, abnormal or runaway growth is due to external surface inclusions, and spits are due to nonuniform evaporation. All these defects have adverse effects on the coatings. They induce stresses and produce porosity in the coatings and thus weaken their mechanical properties. Friction and wear characteristics are affected by coating defects, since the large nodules are pulled out and additional wear debris is generated.

Spalvins, T.↗

Objective tropical cyclone analysis and forecasting technique using conventional and Nimbus-5 electrically scanning microwave radiometer measurements

The ADAPT empirical analysis programs, based on finding an optimal representation of the data in the Karhunen-Loeve sense, were applied to 120 observations of twenty-nine 1973 and 1974 Pacific tropical cyclones. Each observation consists of NIMBUS-5 electrically scanning microwave radiometer (ESMR) radiation measurements at 267 grid points covering and surrounding the tropical cyclone plus nine other non-satellite derived descriptors. Analysis and forecast algorithms to estimate storm motion and intensity were developed for times ranging from the observation time up to 72 hours later. The 24 hr wind speed forecasts with an accuracy of 11.7 knots and position forecasts with accuracies 15% better than persistence were demonstrated using independent tests.

Hunter, H. E.↗

Scanning and focusing mechanisms of METEOSAT radiometer

Two mechanisms, both of screw-jack type are described. The scanning mechanism, an oil lubricated and sealed unit drives and accurately positions the telescope of the METEOSAT radiometer. The dry lubricated focusing mechanism is used to adjust the focus of this telescope. The METEOSAT program is nearly completed, and the first flight model will be launched at the end of the year.

Jouan, J.↗

Torque-while-turnaround scan mirror assembly

Mechanical aspects in the development of an oscillating scan mirror mechanism were reviewed, that featured a remarkably low level of structural vibration for the impact energies involved in mirror oscillation. Another feature was that energy lost during impact was returned to the mirror by applying torque only during the instant of impact. Because the duration of impact was only about 0.010 second, it was critical that energy losses be minimal because there was not much time to restore them.

Starkus, C. J.↗

Evaluation and analysis of Seasat-A Scanning multichannel Microwave radiometer (SMMR) Antenna Pattern Correction (APC) algorithm. Sub-task 2: T sub B measured vs. T sub B calculated comparison results

Interim Antenna Pattern Correction (APC) brightness temperature measurements for all ten SMMR channels are compared with calculated values generated from surface truth data. Plots and associated statistics are presented for the available points of coincidence between SMMR and surface truth measurements acquired for the Gulf of Alaska SEASAT Experiment. The most important conclusions of the study deal with the apparent existence of different instrument biases for each SMMR channel, and their variation across the scan.

Kitzis, J. L.↗

Spatially resolved infrared observations of Saturn. I - Equatorial limb scans at 20 microns

Infrared drift scans of areas near the equator of Saturn are analyzed which were made through narrow-band filters with central wavelengths of 17.8, 19.7, and 22.7 microns. The results are compared with several different models of the atmosphere of Saturn based on the planet's thermal IR emission spectrum. It is found that the model of Tokunaga and Cess (1977) is the best of the published models as a representation of the equatorial atmosphere of Saturn and that a model developed by Gautier et al. (1977) is also quite acceptable in view of the experimental uncertainties.

Caldwell, J.↗